Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear spectral function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Study of Short-Range nuclear Correlations in light nuclei using the BeAGLE event generator

Nuclear dynamics at short distances among nucleons is one of the most outstanding phenomena in nuclear physics. Understanding the role of QCD in generating nuclear forces is important for uncovering the underlying physics of Short-Range Correlations (SRCs). In recent years, SRCs has been observed from light to heavy nuclei using fixed target experiments at Jefferson lab via high energy electron-nucleus scattering. In this talk, I will talk about the opportunity of studying SRCs using light nuclei with collider experiments, e.g., the Electron-Ion Collider (EIC). The experimental technique of studying the light nuclei can be based on exclusive processes with tagging final-state particles, in order to fully control the initial state of the target wavefunction. In particular, incoherent diffractive production of J/\psi J / ψ particle off deuteron will be presented. In addition, the spectral function in light nuclei has been recently modeled in the BeAGLE event generator, where the decay kinematics of the light nuclei and their influence on the very forward detector design at the EIC will be discussed.

Tu, Zhoudunming↗

Remote quantification of Cm(III) and HNO 3 by fluorescence spectroscopy and chemometrics

A unique approach to remotely quantify Cm(III) (0–100 µg mL −1 ) in HNO 3 (1–12 M) using steady-state laser fluorescence spectroscopy and multivariate regression models was developed. Photoluminescence is amenable to remote measurements using fiber-optic cables and is sensitive to numerous lanthanide and actinide species. In-line measurements can provide feedback to support complex processing in harsh environments (e.g., hot cells) to help guide and optimize radiochemical separations. In this work, Cm(III) spectra were acquired remotely in a glove box as a function of HNO 3 concentration to better understand spectral characteristics and evaluate the utility of multivariate regression models in this system. Furthermore, the Cm(III) fluorescence peak shape, width, position, and intensity changed significantly as a function of HNO 3 concentration, likely because of the displacement of emission quenching inner-sphere water molecules and complexation with nitrate ions. Despite significant covariance and nonlinearity in the data, a D-optimal design strategy successfully minimized training set sample size and was used to build effective partial least squares regression models for Cm(III) and HNO 3 concentrations without a priori knowledge of solution conditions. Chemometrics for modeling complex fluorescence spectra are promising and may find widespread applicability for online analysis in numerous chemical systems found in the nuclear field.

Actinide↗

Measuring the diffraction properties of an imaging quartz(211) crystal

A dual goniometer X-ray system was used to measure the reflectivity curve for a spherically bent quartz(211) crystal. An analysis of the dual goniometer instrument response function for the rocking curve width measurement was developed and tested against the actual measurements. The rocking curve was measured at 4510.8 eV using the Ti Kα1 characteristic spectral line. The crystal is the dispersion element for a high resolution spectrometer used for plasma studies. It was expected to have a very narrow rocking curve width. The analysis showed that we could measure the upper bound for the rocking curve width of the Qz(211) crystal. The upper bound was 58 μrad giving a lower bound for the instrument resolving power E/ΔE = 34 000. Greatly improved insight into the dual goniometer operation and its limitations was achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct solution of Minkowski-space Bethe-Salpeter equation in the massive Wick-Cutkosky model

Here in order to solve the Bethe-Salpeter equation (BSE) in the Minkowski space, we first introduce the Nakanishi integral representations of the Bethe-Salpeter amplitude and the Bethe-Salpeter wave function. We then derive the explicit integral equations for the corresponding spectral functions from the BSE for states of two scalar particles bound by a scalar-particle exchange interaction, where the propagators of constituents are allowed to be fully dressed. These integral equations are subsequently solved numerically in the variation of the Wick-Cutkosky model with massive exchange particles, where an algorithm of adaptive mash grid is proposed. The equations and algorithm we develop here serve as the foundation of Minkowski-space formulation of BSE for bound states of fermions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation detector device for rejecting and excluding incomplete charge collection events

A radiation detector device is provided that is capable of distinguishing between full charge collection (FCC) events and incomplete charge collection (ICC) events based upon a correlation value comparison algorithm that compares correlation values calculated for individually sensed radiation detection events with a calibrated FCC event correlation function. The calibrated FCC event correlation function serves as a reference curve utilized by a correlation value comparison algorithm to determine whether a sensed radiation detection event fits the profile of the FCC event correlation function within the noise tolerances of the radiation detector device. If the radiation detection event is determined to be an ICC event, then the spectrum for the ICC event is rejected and excluded from inclusion in the radiation detector device spectral analyses. The radiation detector device also can calculate a performance factor to determine the efficacy of distinguishing between FCC and ICC events.

36 MATERIALS SCIENCE↗

ENDF/B-VII.1 Neutron Cross Section Data Testing with Critical Assembly Benchmarks and Reactor Experiments

The ENDF/B-VII.1 library is the latest revision to the United States' Evaluated Nuclear Data File (ENDF). The ENDF library is currently in its seventh generation, with ENDF/B-VII.0 being released in 2006. This revision expands upon that library, including the addition of new evaluated files (was 393 neutron files previously, now 418 including replacement of elemental vanadium and zinc evaluations with isotopic evaluations) and extension or updating of many existing neutron data files. Complete details are provided in the companion paper [1]. This paper focuses on how accurately application libraries may be expected to perform in criticality calculations with these data. Continuous energy cross section libraries, suitable for use with the MCNP Monte Carlo transport code, have been generated and applied to a suite of nearly one thousand critical benchmark assemblies defined in the International Criticality Safety Benchmark Evaluation Project's International Handbook of Evaluated Criticality Safety Benchmark Experiments. This suite covers uranium and plutonium fuel systems in a variety of forms such as metallic, oxide or solution, and under a variety of spectral conditions, including unmoderated (i.e., bare), metal reflected and water or other light element reflected. Assembly eigenvalues that were accurately predicted with ENDF/B-VII.0 cross sections such as unmoderated and uranium reflected 235U and 239Pu assemblies, HEU solution systems and LEU oxide lattice systems that mimic commercial PWR configurations continue to be accurately calculated with ENDF/B-VII.1 cross sections, and deficiencies in predicted eigenvalues for assemblies containing selected materials, including titanium, manganese, cadmium and tungsten are greatly reduced. Improvements are also confirmed for selected actinide reaction rates such as 236U capture. Other deficiencies, such as the overprediction of Pu solution system critical eigenvalues and a decreasing trend in calculated eigenvalue for 233U fueled systems as a function of Above-Thermal Fission Fraction remain. The comprehensive nature of this critical benchmark suite and the generally accurate calculated eigenvalues obtained with ENDF/B-VII.1 neutron cross sections support the conclusion that this is the most accurate general purpose ENDF/B cross section library yet released to the technical community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Online monitoring of solutions within microfluidic chips: simultaneous Raman and UV-Vis absorption spectroscopies

Microfluidics is an appealing analytical tool in the global effort to close the nuclear fuel cycle. Using a microfluidic chip permits analysis of greatly reduced sample volumes compared to what is necessary for traditional analytical methods. There is a commensurate reduction in disposal volume and cost. Development of spectroscopic methods practicable on the microscale are necessary to take advantage of the microchip configuration. This study uses simultaneously applied UV-vis and micro-Raman spectroscopies adapted to function on the microscale to analyze in situ both the Nd3+ (UV-vis active) and HNO3 (Raman active) concentrations in the same sample. An adjustable translation platform was designed to hold the micro-Raman probe above and perpendicular to the chip face, and the UV-vis probe in the plane of the chip. These complimentary spectral techniques when processed through multivariate PLS (Partial Least Squares) models gave an accurate picture of the widely varying solution concentrations as a function of time for each solution component. Solution matrix effects can drastically alter analyte signatures as measured by both UV-vis absorbance and Raman spectroscopy. PLS methods successfully modeled these spectral changes and accurately measured concentrations of components of interest within the microfluidic chip.

on-line monitoring, microfluidics, Raman, UV-vis↗

Band-to-band transitions and critical points in the near-infrared to vacuum ultraviolet dielectric functions of single crystal urania and thoria

Band-to-band transition energy parameters for single-crystal actinide samples of uranium oxide and thorium oxide were determined and compared using spectroscopic ellipsometry and critical-point dielectric function analyses. Spectroscopic ellipsometry measurements from the near-infrared to the vacuum ultraviolet spectral region were used to determine the dielectric functions of uranium oxide and thorium oxide. Furthermore, the critical-point structure is similar between UO 2 and ThO 2 but strongly blue shifted for ThO 2 . We find bandgap energies of 2.1 eV and 5.4 eV for UO2 and ThO2, respectively.

42 ENGINEERING↗

DFT modeling of Spectral and Redox Properties of Di-and Tetranuclear Ruthenium Transition Metal Complexes with Bridging Ligands

The electronic structures of di-and tetranuclear transition metal complexes with bridging ligands (tetracyanoethene, tetracyano-p-quinodimethane, divinylphenylene and tetrakis(4-styryl)ethene) were calculated by density functional (DFT) method. DFT method was used for calculations of IR frequencies in different oxidation states and EPR parameters of radical ions. The observed electronic transitions of closed shell systems were assigned by TD DFT. The different aspects of bridge mediated metal-metal interaction are discussed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inelastic neutron scattering and molecular simulation of the dynamics of interlayer water in smectite clay minerals

The study of mineral–water interfaces is of great importance to a variety of applications including oil and gas extraction, gas subsurface storage, environmental contaminant treatment, and nuclear waste repositories. Understanding the fundamentals of that interface is key to the success of those applications. Confinement of water in the interlayer of smectite clay minerals provides a unique environment to examine the interactions among water molecules, interlayer cations, and clay mineral surfaces. Smectite minerals are characterized by a relatively low layer charge that allows the clay to swell with increasing water content. Montmorillonite and beidellite varieties of smectite were investigated to compare the impact of the location of layer charge on the interlayer structure and dynamics. Inelastic neutron scattering of hydrated and dehydrated cation-exchanged smectites was used to probe the dynamics of the interlayer water (200–900 cm –1 spectral region) and identify the shift in the librational edge as a function of the interlayer cation. Molecular dynamics simulations of equivalent phases and power spectra, derived from the resulting molecular trajectories, indicate a general shift in the librational behavior with interlayer cation that is generally consistent with the neutron scattering results for the monolayer hydrates. Both neutron scattering and power spectra exhibit librational structures affected by the location of layer charge and by the charge of the interlayer cation. Furthermore, divalent cations (Ba 2+ and Mg 2+ ) characterized by large hydration enthalpies typically exhibit multiple broad librational peaks compared to monovalent cations (Cs + and Na + ), which have relatively small hydration enthalpies.

36 MATERIALS SCIENCE↗

Geophysical borehole logging data of wells ER-GLS1, ER-GUM1, ER-PLM7, and ER-PLM8 at the East River Watershed, Colorado

The purpose of this data set is to provide a means of characterizing the bedrock variability both within a single borehole location and across the East River Watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States, and all boreholes are located within Mancos shale bedrock. The data set contains geophysical borehole logging data acquired in October 2018 in boreholes ER-GUM1 (East River- Gothic Upper Montane Borehole #1) and ER-GLS1 (East River- Gothic Lower Subalpine Borehole #1), and acquired in October 2019 in boreholes ER-PLM7 (East River- Pumphouse Lower Montane Borehole #7) and ER-PLM8 (East River- Pumphouse Lower Montane Borehole #8). It contains depth, natural gamma ray emission, spectral gamma ray emission(Th, K, U), magnetic susceptibility, fluid temperature and electrical conductivity, electromagnetic (EM) induction derived rock electrical resistivity, heat pulse and spinner flow measurements to estimate groundwater flow, and Nuclear Magnetic Resonance (NMR) derived water content and hydraulic conductivity. Data for each borehole are provided as comma delimited text files. For each borehole accurate location information is provided (based on RTK GPS (Real Time Kinematic Global Positioning System) surveying). Borehole logging data were acquired using Mount Sopris borehole tools, and Vista Clara Javelin for NMR data.

54 ENVIRONMENTAL SCIENCES↗

Orbits and Masses of Binaries from Speckle Interferometry at SOAR

We present results from Speckle inteferometric observations of 15 visual binaries and one double-line spectroscopic binary, carried out with the HRCam Speckle camera of the SOAR 4.1 m telescope. These systems were observed as a part of an on-going survey to characterize the binary population in the solar vicinity, out to a distance of 250 pc. We obtained orbital elements and mass sums for our sample of visual binaries. The orbits were computed using a Markov Chain Monte Carlo algorithm that delivers maximum likelihood estimates of the parameters, as well as posterior probability density functions that allow us to evaluate their uncertainty. Their periods cover a range from 5 yr to more than 500 yr; and their spectral types go from early A to mid M, implying total system masses from slightly more than 4M{sub ⊙} down to 0.2M {sub ⊙}. They are located at distances between approximately 12 and 200 pc, mostly at low Galactic latitude. For the double-line spectroscopic binary YSC8, we present the first combined astrometric/radial-velocity orbit resulting from a self-consistent fit, leading to individual component masses of 0.897 ± 0.027 M {sub ⊙} and 0.857 ± 0.026 M {sub ⊙}; and an orbital parallax of 26.61 ± 0.29 mas, which compares very well with the Gaia DR2 trigonometric parallax (26.55 ± 0.27 mas). In combination with published photometry and trigonometric parallaxes, we place our objects on an H-R diagram and discuss their evolutionary status. We also present a thorough analysis of the precision and consistency of the photometry available for them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deconvolution of Thomson scattering temperature profiles

Deconvolution of Thomson scattering (TS) profiles is required when the gradient length of the electron temperature (T{sub e}) or density (n{sub e}) are comparable to the instrument function length ({Delta}{sub R}). The most correct method for deconvolution to obtain underlying T{sub e} and n{sub e} profiles is by consideration of scattered signals. However, deconvolution at the scattered signal level is complex since it requires knowledge of all spectral and absolute calibration data. In this paper a simple technique is presented where only knowledge of the instrument function I(r) and the measured profiles, T{sub e,observed}(r) and n{sub e,observed}(r), are required to obtain underlying T{sub e}(r) and n{sub e}(r). This method is appropriate for most TS systems and is particularly important where high spatial sampling is obtained relative to {Delta}{sub R}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Series Evaluation of Radiation Portal Monitor Data for Point Source Discrimination.

A novel algorithm approach to evaluating data from PVT-based Radiation Portal Monitor (RPM) systems is established. Time series of data from RPMs are evaluated for the presence of sources of interest by comparing the background to the vehicle spectrum at each successive time step, isolating the contribution of anomalous radiation. At each time in the data sequence, a “spectral distance” index is calculated using this method. This method may dramatically reduce systematic fluctuations due to background attenuation by a vehicle (the so-called “shadow shielding” effect), and allow for time-series matched filtering for discrimination of compact anomalous sources. This is attempted by using a wavelet filter function of similar size to the expected source profile on the output of the spectral distance method. Performance of this method is shown by analysis (injection studies) of a number of real drive-through data sets taken at a U.S. port of entry. Spectra from isotopes of interest are injected into the data set, and the resultant “benign” and “injected” data sets are analyzed with gross-counting, spectral distance, and spatial algorithms. The combination of spectral and spatial analysis methods showed a significant increase to detection performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing dynamics in colloidal crystals with pump-probe experiments at LCLS: Methodology and analysis

We present results of the studies of dynamics in colloidal crystals performed by pump-probe experiments using an X-ray free-electron laser (XFEL). Colloidal crystals were pumped with an infrared laser at a wavelength of 800 nm with varying power and probed by XFEL pulses at an energy of 8 keV with a time delay up to 1000 ps. The positions of the Bragg peaks, and their radial and azimuthal widths were analyzed as a function of the time delay. The spectral analysis of the data did not reveal significant enhancement of frequencies expected in this experiment. As a result, this allowed us to conclude that the amplitude of vibrational modes excited in colloidal crystals was less than the systematic error caused by the noise level.

36 MATERIALS SCIENCE↗

Rod internal pressure quantification and distribution analysis using Frapcon

This report documents work performed supporting the Department of Energy (DOE) Office of Nuclear Energy (NE) Fuel Cycle Technologies Used Fuel Disposition Campaign (UFDC) under work breakdown structure element 1.02.08.10, ST Analysis. In particular, this report fulfills the M4 milestone M4FT- 15OR0810036, Quantify effects of power uncertainty on fuel assembly characteristics, within work package FT-15OR081003 ST Analysis-ORNL. This research was also supported by the Consortium for Advanced Simulation of Light Water Reactors (http://www.casl.gov), an Energy Innovation Hub (http://www.energy.gov/hubs) for Modeling and Simulation of Nuclear Reactors under U.S. Department of Energy Contract No. DE-AC05-00OR22725. The discharge rod internal pressure (RIP) and cladding hoop stress (CHS) distributions are quantified for Watts Bar Nuclear Unit 1 (WBN1) fuel rods by modeling core cycle design data, operation data (including modeling significant trips and downpowers), and as-built fuel enrichments and densities of each fuel rod in FRAPCON-3.5. A methodology is developed which tracks inter-cycle assembly movements and assembly batch fabrication information to build individual FRAPCON inputs for each evaluated WBN1 fuel rod. An alternate model for the amount of helium released from the zirconium diboride (ZrB2) integral fuel burnable absorber (IFBA) layer is derived and applied to FRAPCON output data to quantify the RIP and CHS for these types of fuel rods. SCALE/Polaris is used to quantify fuel rodspecific spectral quantities and the amount of gaseous fission products produced in the fuel for use in FRAPCON inputs. Fuel rods with ZrB2 IFBA layers (i.e., IFBA rods) are determined to have RIP predictions that are elevated when compared to fuel rod without IFBA layers (i.e., standard rods) despite the fact that IFBA rods often have reduced fill pressures and annular fuel pellets. The primary contributor to elevated RIP predictions at burnups less than and greater than 30 GWd/MTU is determined to be the total fuel rod void volume and the amount of released fission gas in the fuel rod, respectively. Cumulative distribution functions (CDFs) are prepared from the distribution of RIP and CHS predictions for all standard and IFBA rods. The provided CDFs allow for the determination of the portion of WBN1 fuel rods that exceed a specified RIP or CHS limit. Results are separated into IFBA and standard rods so that the two groups may be analyzed individually. FRAPCON results are provided in sufficient detail to enable the recalculation of the RIP while considering any desired plenum gas temperature, total void volume, or total amount of gas present in the void volume. A method to predict the CHS from a determined or assumed RIP is also proposed, which is based on the approximately linear relationship between the CHS and the RIP. Finally, improvements to the computational methodology of FRAPCON are proposed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Atomic data and spectral line intensities for Ni XIV

Electron impact collision strengths, energy levels, oscillator strengths, and spontaneous radiative decay rates are calculated for Ni XIV. We include in the calculations all the configurations belonging to the n=3 complex, and provide data for the lowest 143 fine-structure levels, belonging to the configurations 3s{sup 2}3p{sup 3}, 3s3p{sup 4}, 3s{sup 2}3p{sup 2}3d, 3p{sup 5}, 3s3p{sup 3}3d, and 3s{sup 2}3p3d{sup 2}. Collision strengths are calculated at six incident energies for all transitions: 0.112, 8.07, 21.3, 43.4, 80.3, and 141.8 Ry above the threshold of each transition. Calculations have been carried out using the Flexible Atomic Code. Excitation rate coefficients are calculated as a function of electron temperature by assuming a Maxwellian electron velocity distribution. Using the excitation rate coefficients and the radiative transition rates of the present work, statistical equilibrium equations for level populations are solved at electron densities covering the range of 10{sup 8}-10{sup 14} cm{sup -3} and at an electron temperature of logT{sub e}(K)=6.3, corresponding to the maximum abundance of Ni XIV. Spectral line intensities are calculated, and their diagnostic relevance is discussed. This data set is available in version 6.0 of the CHIANTI database.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗