Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “neutron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Detectability of Martian carbonates from orbit using thermal neutrons

Numerical simulations of Martian neutron leakage flux spectra are made in order to explore the detectability of magnesium and calcium carbonate deposits using neutron spectroscopic techniques from orbit. The primary signature of such deposits is found to be an enhanced thermal amplitude. Although this enhancement is weakened by: (1) partial burial beneath an aeolian regolith blanket; (2) admixture with regolith on a microscopic (centimeter) or macroscopic (tens of centimeters) scale; and (3) reduction in the areal size of the deposit, near-surface stratigraphies of carbonates hypothesized by some authors as possible on Mars are still detectable by simple neutron sensors from orbit. However, the large variations in the magnitude of the thermal neutron enhancements caused by different carbonate deposit configurations found in this study require a combined gamma ray and neutron analysis for their unique specification.

Feldman, W. C.↗

Generalized method for the optimization of pulse shape discrimination parameters

Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and discriminated. In neutron measurements for nuclear security and non proliferation effective PSD is crucial, because a weak neutron signature needs to be detected in the presence of a strong gamma-ray background. Here, the most commonly used deterministic PSD technique is charge integration (CI). This method requires the optimization of specific parameters to obtain the best gamma-neutron separation. These parameters depend on the scintillating material and light readout device and typically require a lengthy optimization process and a calibration reference measurement with a mixed source. In this paper, we propose a new method based on the scintillation fluorescence physics that enables to find the optimum PSD integration gates using only a gamma-ray emitter. We demonstrate our method using three organic scintillation detectors: deuterated trans-stilbene, small-molecule organic glass, and EJ-309. In all the investigated cases, our method allowed finding the optimum PSD CI parameters without the need of iterative optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automating Anomaly Detection for Target systems at Spallation Neutron Source

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, produces the world’s most intense pulse neutrons beams. An accelerated proton beam is directed into a mercury target to generate neutrons via spallation. The target system accounted for over 40% of the overall downtime of the facility in 2022. Thus, early detection in anomalies in the target systems can enable taking corrective actions to avoid failures and reduce downtime. Fault prognostics and anomaly detection in accelerators, both at SNS and outside, has largely focused on the beam side. This paper presents one the first studies exploring leveraging machine learning to automate the detection of anomalies in the target system. The target system consists of over 30 different interconnected subsystems, and the present work focuses on the mercury process system as a use case. Analyzing data from 28 process variables from 2022 and 2023, tree-based and reconstruction-based algorithms are employed to detect anomalies in archived data. The algorithms detected previously unreported anomalies, several of which were deemed alert worthy by human experts, particularly those found by reconstruction-based algorithms. Using data from each production run in the accelerator increased the generalizability of the models in time. Efforts are now underway to implement a workflow for incorporating human feedback to update the models and evaluating performance on unseen data. The models will eventually be integrated into the existing System Tracking and Reliability system with a web interface for automated anomaly detection and reporting along with a pathway for incorporating human feedback for model updates.

Raj, Anant [ORNL] (ORCID:0000000306711244)↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

Reconstruction of fast neutron direction in segmented organic detectors using deep learning

A method for reconstructing the direction of a fast neutron source using a segmented organic scintillator-based detector and deep learning model is proposed and analyzed. Here, the model is based on recurrent neural network, which can be trained by a sequence of data obtained from an event recorded in the detector and suitably pre-processed. The performance of deep learning-based model is compared with the conventional double-scatter detection algorithm in reconstructing the direction of a fast neutron source. With the deep learning model, the uncertainty in source direction of 0.301 rad is achieved with 100 neutron detection events in a segmented cubic organic scintillator detector with a side length of 46 mm. To reconstruct the source direction with the same angular resolution as the double-scatter algorithm, the deep learning method requires 75% fewer events. Application of this method could augment the operation of segmented detectors operated in the neutron scatter camera configuration for applications such as special nuclear material detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Neutron Leakage Spectra Sensitivities for ICSBEP Benchmarks

Neutron leakage spectra have been measured, simulated, and investigated by many groups. These spectra have many uses, including determining shielding requirements and calculating dose for radiation protection purposes, validating nuclear data, and determining material composition. It has even been proposed to use measurements of neutron leakage spectra to determine the soil composition of Mars. As part of the Los Alamos National Laboratory (LANL) Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) Laboratory Directed Research Development (LDRD) project, the authors are working on developing methods to calculate sensitivities to neutron leakage spectra. This may allow nuclear data evaluators to better use neutron leakage spectra data to constrain or adjust nuclear data. This may also be particularly useful as many neutron leakage spectra measurements do not require fissile material and can be performed with well characterized neutron sources. Neutron leakage spectra measurements are usually performed by placing a detector at the outside of a nuclear system. This may be a reactor, a neutron generator, or a neutron source. Certain detection systems can use pulse height data to infer neutron energies, other detector systems rely on other ways of determining neutron energy (for example, a Bonner sphere with multiple moderator thicknesses can be used to measure neutron spectrum). These measurements typically rely on some unfolding of the measured results. For pulsed systems like the "Livermore Pulsed Spheres," time-of-flight information can also help to constrain the neutron energy spectra data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of Reflection Features in the Neutron Star Low-mass X-Ray Binary Serpens X-1 with NICER

We present Neutron Star Interior Composition Explorer (NICER) observations of the neutron star (NS) low-mass X-ray binary Serpens X-1 during the early mission phase in 2017. With the high spectral sensitivity and low-energy X-ray passband of NICER, we are able to detect the Fe L line complex in addition to the signature broad, asymmetric Fe K line. We confirm the presence of these lines by comparing the NICER data to archival observations with XMM-Newton/Reflection Grating Spectrometer (RGS) and NuSTAR. Both features originate close to the innermost stable circular orbit (ISCO). When modeling the lines with the relativistic line model RELLINE, we find that the Fe L blend requires an inner disk radius of 1.4(sup 0.2, sub -0.1)R(sub ISCO) and Fe K is at 1.03(sup 0.13, sub -0.03)R(sub ISCO) (errors quoted at 90%). This corresponds to a position of 17(sup 2.5, sub -1.2)km and 12(sup 1.6, sub -0.4)km for a canonical NS mass (M(sub NS)=1.4 solar mass) and dimensionless spin value of a = 0. Additionally, we employ a new version of the RELXILL model tailored for NS(sub s) and determine that these features arise from a dense disk and supersolar Fe abundance.

Ludlam, R. M.↗

Optimizing the spatial resolution and gamma discrimination of SiPM-based Anger cameras

SiPM Anger cameras have been designed for use as 2-dimensional thermal neutron detectors for scientific applications such as at single crystal diffraction instruments. These cameras utilize a neutron sensitive scintillator and an array of SiPM photosensors, separated by a light spreading glass. While this optics package is very effective at detecting and positioning neutrons, it is also sensitive to gamma rays, which are a source of unwanted noise. In this work, we underwent a search of scintillator and spreader glass thicknesses to determine the optimal combination for maximizing spatial resolution. Both experimental results and GEANT4 simulations are presented. Further, to address the issue of gamma ray detection, we have also designed and presented a multi-layer scintillator that reduces the amount of scintillation light produced via gamma-ray energy deposition, allowing for easier pulse-height discrimination. A sample of this geometry has been produced that results in a factor of 2 improvement over an equivalent thickness monolithic scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement in the spatial resolution for imaging with fast neutrons

In this paper, we report on the realization of an improved concept for the detection of fast neutrons using a specific setup of scintillators with the aim to overcome limitations in spatial resolution. While fast neutron imaging (FNI) is a technique to investigate very thick material layers in transmission mode, currently there is a limit in the spatial resolution at ~1 mm, which hinders the performance for the detection of features like cracks, material damage or pores in large objects ($\gg$1 cm 3 ). The improved concept presented here is based on the separation of the converter material from the scintillation layer in a suitable way, which was successfully tested and referenced to the standard devices at the NECTAR facility (FRM-2, MLZ, Garching) under realistic beamline conditions. The results imply a break-through in enabling detection of structures on the order of 0.2 to 0.5 mm (a more precise estimation is not possible due to other resolution determing factors in a realistic setup). Potential additional improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation light detection in polycrystalline diamond using single photon detectors

Here, this study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive 6 LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.

47 OTHER INSTRUMENTATION↗

EUV/soft x-ray spectra for low B neutron stars

Recent ROSAT and EUVE detections of spin-powered neutron stars suggest that many emit 'thermal' radiation, peaking in the EUV/soft X-ray band. These data constrain the neutron stars' thermal history, but interpretation requires comparison with model atmosphere computations, since emergent spectra depend strongly on the surface composition and magnetic field. As recent opacity computations show substantial change to absorption cross sections at neutron star photospheric conditions, we report here on new model atmosphere computations employing such data. The results are compared with magnetic atmosphere models and applied to PSR J0437-4715, a low field neutron star.

Romani, Roger W.↗

Astrometric microlensing probes of the isolated neutron star population with Roman

Notoriously hard to detect and study, isolated neutron stars (NSs) might provide valuable answers to fundamental questions about stellar evolution and explosion physics. With the upcoming Roman Space Telescope, scheduled for launch in 2026, a new and powerful channel for their detection will become available: astrometric microlensing. We set out to create a realistic sample of simulated gravitational microlensing events as observed by Roman with the Galactic Bulge Time Domain Survey. We focus in particular on the population of NS lenses, which has until now been largely understudied. We used dedicated Galactic models tailored for application to microlensing by compact objects. In addition to populations of stars, white dwarfs, and black holes, we simulated four different NS populations with Maxwellian natal kick distributions: v = (150, 250, 350, 450) km/s. For each simulation, we applied projected Roman precision, cadence, and detectability criteria. We found that the parameter space log10 t E –log 10 θ E , which will be accessible to Roman observations, is efficient for the classification of stellar remnants. We found a feature in this space that is characteristic of NSs; using this feature, optimal samples of NS candidates can be constructed from Roman -like datasets. We describe the dependence of the observable parameter distributions on the assumed mean kick velocities. As the effects of natal kicks are very complex and mutually counteracting, we suggest that more detailed studies focused on the dynamics of NSs are needed in anticipation of Roman and future surveys. We estimate that Roman will observe approximately 11 000 microlensing events, including ~100 with NS lenses, whose photometric and astrometric signals are detectable; the event yield decreases by 38% when gap-filling low-cadence observations are not included. We make all simulated microlensing event datasets publicly available in preparation for Roman data.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing the Experiment for Calibration with Uranium (Excalibur) neutron source for use in warhead verification

Neutron sources can play a variety of roles in warhead verification. For transmission radiography, a source of directed high energy neutrons is required, while for applications to detect fissile isotopes, sub-MeV neutrons are preferred. The Excalibur (Experiment for Calibration with Uranium) neutron source has been built and used in a variety of verification-related experiments. Excalibur is based on a commercial deuterium-tritium neutron generator specified and measured to be capable of producing 14 MeV neutrons at rates of up to 8.2 × 10 8 neutrons/s. Here, the generator is enclosed in a carbon-steel 32" diameter, 23.62" high carbon-steel cylinder that moderates the mean neutron energy to under 500 keV. This, in turn, is encased in 5%-borated polyethylene such that the entire assembly is a 48" x 48" box that is 30" tall. For radiographic applications, a narrow, tapered channel in the steel and polyethylene allows 14 MeV neutrons to stream directly from the generator to a test object. Its collimating capability is demonstrated by measuring the neutron flux profile. In the moderated mode of operation, the generator is fully enclosed in the steel, but a large section of the polyethylene is removed, providing a flux of sub-MeV neutrons from a wide range of angles. Neutron angular and spectral measurements using both a nested neutron spectrometer and a commercial liquid scintillator coupled with a 3 He detector show the expected softer neutron spectrum in moderated mode in good agreement with MCNP6 calculations. The gamma-ray spectrum from Excalibur is also in good agreement with MCNP modeling. Based on these findings, the future application of Excalibur in its two configurations is discussed.

Fissile material detection↗

A comparison of machine learning methods to classify radioactive elements using prompt-gamma-ray neutron activation data

The detection of illicit radiological materials is critical to establishing a robust second line of defence in nuclear security. Neutron-capture prompt-gamma activation analysis (PGAA) can be used to detect multiple radioactive materials across the entire Periodic Table. However, long detection times and a high rate of false positives pose a significant hindrance in the deployment of PGAA-based systems to identify the presence of illicit substances in nuclear forensics. In the present work, six different machine-learning algorithms were developed to classify radioactive elements based on the PGAA energy spectra. The model performance was evaluated using standard classification metrics and trend curves with an emphasis on comparing the effectiveness of algorithms that are best suited for classifying imbalanced datasets. We analyse the classification performance based on Precision, Recall, F1-score, Specificity, Confusion matrix, ROC-AUC curves, and Geometric Mean Score (GMS) measures. The tree-based algorithms (Decision Trees, Random Forest and AdaBoost) have consistently outperformed Support Vector Machine and K-Nearest Neighbours. Based on the results presented, AdaBoost is the preferred classifier to analyse data containing PGAA spectral information due to the high recall and minimal false negatives reported in the minority class.

97 MATHEMATICS AND COMPUTING↗

First Detection of X-Ray Polarization from the Accreting Neutron Star 4U 1820−303

This paper reports the first detection of polarization in the X-rays for atoll-source 4U 1820−303, obtained with the Imaging X-ray Polarimetry Explorer (IXPE) at 99.999% confidence level (CL). Simultaneous polarimetric measurements were also performed in the radio with the Australia Telescope Compact Array. The IXPE observations of 4U 1820−303 were coordinated with Swift X-ray Telescope, Neutron Star Interior Composition Explorer, and Nuclear Spectroscopic Telescope Array aiming to obtain an accurate X-ray spectral model covering a broad energy interval. The source shows a significant polarization above 4 keV, with a polarization degree of 2.0% ± 0.5% and a polarization angle of −55° ± 7° in the 4–7 keV energy range, and a polarization degree of 10% ± 2% and a polarization angle of −67° ± 7° in the 7–8 keV energy bin. This polarization also shows a clear energy trend with polarization degree increasing with energy and a hint for a position-angle change of ≃90° at 96% CL around 4 keV. The spectro-polarimetric fit indicates that the accretion disk is polarized orthogonally to the hard spectral component, which is presumably produced in the boundary/spreading layer. We do not detect linear polarization from the radio counterpart, with a 3σ upper limit of 50% at 7.25 GHz.

4U1820-303↗

Evidence for Harmonic Content and Frequency Evolution of Oscillations During the Rising Phase of X-ray Bursts From 4U 1636-536

We report on a study of the evolution of burst oscillation properties during the rising phase of X-ray bursts from 4U 1636-536 observed with the proportional counter array (PCA) on board the Rossi X-Ray Timing Explorer (RXTE) . We present evidence for significant harmonic structure of burst oscillation pulses during the early rising phases of bursts. This is the first such detection in burst rise oscillations, and is very important for constraining neutron star structure parameters and the equation of state models of matter at the core of a neutron star. The detection of harmonic content only during the initial portions of the burst rise is consistent with the theoretical expectation that with time the thermonuclear burning region becomes larger, and hence the fundamental and harmonic amplitudes both diminish. We also find, for the first time from this source, strong evidence of oscillation frequency increase during the burst rise. The timing behavior of harmonic content, amplitude, and frequency of burst rise oscillations may be important in understanding the spreading of thermonuclear flames under the extreme physical conditions on neutron star surfaces.

Bgattacharyya, Sudip↗