Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mixed precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Development of Gas Analysis Capabilities

Project Description: The project objective was to develop gas analysis methodology and processes to identify and quantify contaminants specific to KSC, primarily volatile organic compounds (VOCs), utilizing the recently purchased gas chromatograph-mass spectrometer (GCMS) coupled with a sample pre-concentrator. This work established a standing, quick-turnaround quantitative GCMS methodology for KSC-specific VOCs associated with launching and landing spacecraft at trace-levels far below previous detection limits. Closeout Summary: This project established a standing methodology for rapid turnaround identification and quantification of 119 targeted VOCs considered most likely to be encountered at KSC. Of these, 111 of the calibration files are based on manufacturer-certified gas standard mixes. The other eight were generated using standards generated in-house from neat, certified reference materials using procedures for standard generation that were developed under this project. Additionally, the spectral signatures of two hydrofluorocarbon precision cleaning solvents, that are widely used in flight hardware processing, have been added to the mass spectral library for rapid qualitative identification.

Cristina Oropeza↗

Spatially Resolved Top-Down Proteomics of Tissue Sections Based on a Microfluidic Nanodroplet Sample Preparation Platform

Conventional proteomics measures the averaged signal from mixed cell populations or bulk tissues, leading to the dilution of significant changes in subpopulations of cells that might serve as important biomarkers. Recent developments in bottom-up proteomics have enabled spatial mapping of cellular heterogeneity in tissue microenvironments. However, bottom-up proteomics cannot precisely infer the abundance changes of intact proteins, which are presented as proteoforms. Herein, we described a spatially resolved top-down proteomics (TDP) platform for proteoform identification and quantification directly on thin tissue sections. The spatial TDP platform consisted of a nanoPOTS (nanodroplet Processing in One pot for Trace Samples)-based sample preparation system and an LCM (laser capture microdissection)-based cell isolation system. We improved the nanoPOTS sample preparation by adding benzonase in the extraction buffer to enhance the coverage of nucleus proteins. Using ~200 cultured cells as model samples, the improved approach increased proteoform identifications from 493 to 700; newly identified proteoforms primarily corresponded to nuclear proteins. To demonstrate the spatial TDP platform in tissue samples, we analyzed LCM-isolated tissue voxels from rat brain cortex and hypothalamus regions. We quantified 426 proteoforms by combining identifications from TopPIC and TDPortal with the quantitation from ProMex. Several proteoforms corresponding to the same gene exhibited mixed abundance profiles between two tissue regions, suggesting potential PTM-specific spatial distributions. The spatial TDP workflow has prospects for biomarker discovery at proteoform level from small tissue sections.

59 BASIC BIOLOGICAL SCIENCES↗

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space

Measurements of tropospheric CO2 abundance with global-coverage, a few hundred km spatial and monthly temporal resolution are needed to quantify processes that regulate CO2 storage by the land and oceans. The Orbiting Carbon Observatory (OCO) is the first space mission focused on atmospheric CO2 for measuring total column CO, and O2 by detecting the spectral absorption in reflected sunlight. The OCO mission is an essential step, and will yield important new information about atmospheric CO2 distributions. However there are unavoidable limitations imposed by its measurement approach. These include best accuracy only during daytime at moderate to high sun angles, interference by cloud and aerosol scattering, and limited signal from CO2 variability in the lower tropospheric CO2 column. We have been developing a new laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our initial goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft. Our final goal is to develop a space instrument and mission approach for active measurements of the CO2 mixing ratio at the 1-2 ppmv level. Our technique is much less sensitive to cloud and atmospheric scattering conditions and would allow continuous measurements of CO2 mixing ratio in the lower troposphere from orbit over land and ocean surfaces during day and night. Our approach is to use the 1570nm CO2 band and a 3-channel laser absorption spectrometer (i.e. lidar used an altimeter mode), which continuously measures at nadir from a near polar circular orbit. The approach directs the narrow co-aligned laser beams from the instrument's lasers toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. It uses several tunable fiber laser transmitters which allowing measurement of the extinction from a single selected CO2 absorption line in the 1570 nm band. This band is free from interference from other gases and has temperature insensitive absorption lines. During the measurement the lasers are tuned on- and off- a selected CO2 line near 1572 nm and a selected O2 line near 768 nm in the Oxygen A band at kHz rates. The lasers use tunable diode seed lasers followed by fiber amplifiers, and have spectral widths much narrower than the gas absorption lines. The receiver uses a 1-m diameter telescope and photon counting detectors and measures the background light and energies of the laser echoes from the surface. The extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and offline surface echo via the differential optical absorption technique. Our technique rapidly alternates between several on-line wavelengths set to the sides of the selected gas absorption lines. It exploits the atmospheric pressure broadening of the lines to weight the measurement sensitivity to the atmospheric column below 5 km. This maximizes sensitivity to CO2 in the boundary layer, where variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column will use an identical approach with an O2 line. Thee laser frequencies are tunable and have narrow (MHz) line widths. In combination with sensitive photon counting detectors these enables much higher spectral resolution and precision than is possible with passive spectrometer. 1aser backscatter profiles are also measured, which permits identifying measurements made to cloud tops and through aerosol layers. The measurement approach using lasers in common-nadir-zenith path allows retrieving CO2 column mixing ratios in the lower troposphere irrespective of sun angle. Pulsed laser signals, time gated receiver and a narrow receiver field-of-view are used to isolate the surface laser echo signals and to exclude photons scattered from clouds and aerosols. Nonetheless, the optical absorption change due to a change of a few ppO2 is small, <1 % which makes achieving the needed measurement sensitivities and stabilities quite challenging. Measurement SNRs and stabilities of >600:1 are needed to estimate CO2 mixing ratio at the 1-2 ppm level. We have calculated characteristics of the technique and have demonstrated aspects of the laser, detector and receiver approaches in th e laboratory We have also measured O2 in an absorption cell, and made C02 measurements over a 400 m long (one way) horizontal path using a sensor breadboard. We will describe these and more details of our approach in the paper.

Abshire, James B.↗

The impact of different parameterizations on the interpretation of CP violation in neutrino oscillations

CP violation in the lepton mass matrix will be probed with good precision in upcoming experiments. The amount of CP violation present in oscillations can be quantified in numerous ways and is typically parameterized by the complex phase δ PDG in the standard PDG definition of the lepton mixing matrix. There are additional parameterizations of the lepton mixing matrix as well. Through various examples, we explore how, given the current data, different parameterizations can lead to different conclusions when working with parameterization dependent variables, such as δ. We demonstrate how the smallness of |U e3 | governs the scale of these results. We then demonstrate how δ can be misleading and argue that the Jarlskog is the cleanest means of presenting the amount of CP violation in the lepton sector. We also confirm that, among the different parameterizations considered, the standard PDG parameterization has a number of convenient features.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High resolution chronology of late Cretaceous-early Tertiary events determined from 21,000 yr orbital-climatic cycles in marine sediments

A number of South Atlantic sites cored by the Deep Sea Drilling Project (DSDP) recovered late Cretaceous and early Tertiary sediments with alternating light-dark, high-low carbonate content. The sedimentary oscillations were turned into time series by digitizing color photographs of core segments at a resolution of about 5 points/cm. Spectral analysis of these records indicates prominent periodicity at 25 to 35 cm in the Cretaceous intervals, and about 15 cm in the early Tertiary sediments. The absolute period of the cycles that is determined from paleomagnetic calibration at two sites is 20,000 to 25,000 yr, and almost certainly corresponds to the period of the earth's precessional cycle. These sequences therefore contain an internal chronometer to measure events across the K/T extinction boundary at this scale of resolution. The orbital metronome was used to address several related questions: the position of the K/T boundary within magnetic chron 29R, the fluxes of biogenic and detrital material to the deep sea immediately before and after the K/T event, the duration of the Sr anomaly, and the level of background climatic variability in the latest Cretaceous time. The carbonate/color cycles that were analyzed contain primary records of ocean carbonate productivity and chemistry, as evidenced by bioturbational mixing of adjacent beds and the weak lithification of the rhythmic sequences. It was concluded that sedimentary sequences that contain orbital cyclicity are capable of providing resolution of dramatic events in earth history with much greater precision than obtainable through radiometric methods. The data show no evidence for a gradual climatic deterioration prior to the K/T extinction event, and argue for a geologically rapid revolution at this horizon.

Herbert, Timothy D.↗

Flavor as an Incomplete Structure: Conceptual Questions and the Role of DUNE

Flavor remains one of the most successful yet least understood structures of the Standard Model. The discovery of the Higgs boson completed the electroweak account of mass generation, but did not explain the origin of fermion families, mass hierarchies, or mixing patterns. In this sense, flavor can be regarded as an empirically successful but conceptually incomplete structure. Neutrinos occupy a particularly sensitive place within this problem: their masses are tiny, their mixing is large, and their mass-generation mechanism may differ from that of charged fermions. In this article, we discuss flavor as an open conceptual problem and argue that DUNE, as a phased program spanning precision oscillation measurements and sensitivity to BSM and dark-sector phenomena, provides a powerful framework for testing the self-consistency and possible limits of the present three-flavor description. In particular, the complementarity between the long-baseline program and the Phase I near-detector complex, together with the DUNE-PRISM strategy for controlling interaction-model systematics and enabling data-driven near-to-far predictions, makes DUNE especially well-suited to search for small, correlated departures from the minimal flavor framework.

Montanari, Claudio S. [Fermilab; INFN, Pavia] (ORC↗

Environmental Stress Testing of the Single Sample Cylinder: A Proven Consensus Standard for Internal Gas Analysis (IGA) or Residual Gas Analysis (RGA)

In August 2008, Schuessler Consulting was contracted by NASA GSFC in support of the NASA Electronic Parts and Packaging (NEPP) program to perform two separate studies on moisture laden air in a stainless steel cylinder that had been designed to become a consensus standard for Test Method 1018. This Test Method was originally released for hybrids under Mil. Std. 883 but was quickly utilized on other microelectronic devices under the auspice of Mil. Std. 750. The cylinder had subsequently been fabricated for the 750 community. It was back-filled with moist air and subsequently analyzed over a period of time under a previous NASA contract. It had been shown that moisture in the 4000 - 5000 ppm range could be analyzed rather precisely with a mass spectrometer, commonly referred to as a Residual Gas Analyzer (RGA). The scope of this study was to ascertain if the composition and precision varied as a function of thermal shock at sub-zero temperatures and whether there was consensus when the standard was submitted to other RGA units. It was demonstrated and published that the consensus standard would yield precise RGA data for moisture within +/- 1% when optimized for a given RGA unit. It has been subsequently shown in this study at Oneida Research Services, that sub-zero storage did not affect that precision when a well-defined protocol for the analysis was followed. The consensus standard was taken to a second facility for analysis where it was found that moisture adsorption on the transfer lines caused precision to drop to +/- 12%. The Single Sample Cylinder (SSC) is a one liter stainless steel cylinder with associated sampling valves and has considerable weight and volume. But this considerable size allows for approximately 300 gas samples of the same composition to be delivered to any RGA unit. Lastly, a smaller cylinder, approximately 75 cc, of a second consensus standard was fabricated and tested with a different mix of fixed gases where moisture was kept in the 100 ppm range. This second standard has the potential of providing 30 gaseous samples and can be readily shipped to any analytical facility that desires to generate comparison RGA data. A series of comparison residual gas analyses was performed at the Honeywell Federal Manufacturing & Technologies facility in the National Nuclear Facility Administration s plant in Kansas City to complete this project. It was shown that improvements in the precision of a given RGA unit can be done by controlling the cycle time for each analysis and increasing analysis temperatures to minimize moisture adsorption. It was also found that a "one time event" in the subzero storage of the large SSC did not effect the units ability to continuously supply precise samples of the same chemistry, however the "event" caused a permanent +8% shift in the reported value of the moisture content. Lastly, a set of SSC RGA results was plotted on a common graph with DSCC "correlation study" RGA data. The result demonstrates the ability of the SSC to remove many of the individual variances that single, individual samples introduce. The consensus standards are now in storage at Oneida Research Services, one of the DSCC certified houses that does RGA to Military Standards, where they await future studies. The analytical data and the operational parameters of the instruments used are provided in the following discussion. Limitations and suggested means for improvement of both precision and accuracy are provided.

Schuessler, Philipp WH↗

The Uranian satellites and Hyperion - New spectrophotometry and compositional implications

New reflectance spectra at 3.5 percent resolution have been obtained for Ariel, Titania, Oberon, and Hyperion in the 0.8 to 1.6-micron spectrum region. The new spectra show no absorptions other than the 1.5 micron water-ice feature (within the precision of the data), and demonstrate extension into the 0.8- to 1.6 micron region of the 1.5- to 2.5 micron spectral similarity ofo Ariel to Hyperion (Brown and Cruikshank, 1983). The new data confirm the presence of a dark, spectrally bland component on/in the water-ice surfaces of the Uranian satellites, which, with some reservations, has spectral similarities to the dark substance on the leading side of lapetus and the dark material on/in the surface of Hyperion, as well as other dark, spectrally neutral substances such as charcoal. Attempts were made to match the spectra of Ariel, Titania, and Oberon with additive reflectance mixes (aeral coverage) of fine-grained water frost and various dark components such as charcoal, lampblack, and charcoal-water-ice mixtures. The results were broad limits on the amounts of possible areal coverage of a charcoal-like spectral component on the surfaces of the Uranian satellites, but the data are not of sufficient precision to conclusively determine whether the dominant mode of contaminant dispersal is areal or voluminal. The effect of highly variegated albedos on the diameters derived by Brown, Cruikshank, and Morrison (1982) is found to be small.

Brown, R. H.↗

Dark showers from Z-dark Z′ mixing

Abstract We discuss dark shower signals at the LHC from a dark QCD sector, containing GeV-scale dark pions. The portal with the Standard Model is given by the mixing of theZboson with a darkZ′ coupled to the dark quarks. Both mass and kinetic mixings are included, but the mass mixing is the essential ingredient, as it is the one mediating visible decays of the long-lived dark pions. We focus especially on the possibility that the darkZ′ islighterthan theZ. Indirect constraints are dominated by electroweak precision tests, which we thoroughly discuss, showing that bothZ-pole and low-energy observables are important. We then recast CMS and LHCb searches for displaced dimuon resonances to dark shower signals initiated by the production of on-shellZorZ′, where the visible signature is left by a dark pion decaying toμ + μ − . We demonstrate how dark shower topologies have already tested new parameter space in Run 2, reaching better sensitivity on a light darkZ′ compared to the flavor-changing decays ofBmesons, which can produce a single dark pion at a time, and the electroweak precision tests.

Physics↗

Superallowed 0 + → 0 + nuclear β decays: 2020 critical survey, with implications for V ud and CKM unitarity

A new critical survey of all half-life, decay-energy and branching-ratio measurements related to 23 superallowed 0 + → 0 + β decays is presented. Included are 222 individual measurements of comparable precision obtained from 174 published references. Compared with our last survey in 2015, we have added results from 28 new publications and eliminated an approximately equal number whose results have been superseded by much more precise modern data. We obtain world-average ft values for each of the 21 transitions that have a complete set of data, then apply radiative and isospin-symmetry-breaking corrections to extract “corrected” Ft values. Fifteen of these Ft values now have a precision of 0.3% or better and all take the same value within statistics, as expected from conservation of the vector current. Their average, Ft¯, when combined with the muon lifetime, yields the up-down quark-mixing element of the Cabibbo-Kobayashi-Maskawa matrix, V ud = 0.97373 ± 0.00031. This is lower than our 2015 result by one standard deviation and its uncertainty is increased by 50%. This is a consequence, not of any shifts in the experimental data, but of new calculations for the radiative corrections. The lower V ud value now leads to greater tension in the top-row test of unitarity in the CKM matrix. Updates in experimental data have independently led to a factor-of-two tighter limit being set on the possible existence of a scalar interaction. In conclusion, the new limit on Fierz interference is b F ≤ 0.0033 at the 90% confidence level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FNAS: The magnetic configuration leading to solar flares

We present a method for solving plasma magnetohydrodynamic (MHD) problems arising from the interaction of plasmas with magnetic fields in stellar atmospheres. Our approach, in contrast to previous methods, is not based on solving equations for the magnetic field and plasma velocity but rather studies the evolution of the electric current and density (and the related gas pressure). We have applied the method to several studies involving linearized departures from static, current-free equilibria. The applications show explicit solutions for cases found in astrophysics and to problems encountered with earlier studies where the gas pressure was neglected. The method is particularly well suited for studying situations which involve a transition between high and low plasma-beta regions. It shows precisely how electric currents, and magnetic free-energy, build up in the plasma as a result of the slow stressing of a potential magnetic field configuration. The method also demonstrates how transverse-current waves, a mix of Alfven and magneto-acoustic modes, propagate in a low-beta plasma for any density stratification and background field geometry.

Fontenla, Juan M.↗

Evaluating turbulence models at high energy densities

The RESHOCK campaign at Lawrence Livermore National Laboratory has been working on increasing our understanding of the evolution of turbulent, unstable plasma interfaces which are applicable in various HED applications including ICF implosions. A common approach to model such interfaces involves the use of Renolds-Averaged-Navier-Stokes (RANS) models whose parameters have been constrained by theory and experiments. These parameter sets are not unique and the applicability of one set of tuned model parameters to systems with differing shock strengths or material densities has not been well tested. Our new NIF experiments, along with related studies of turbulent shear flows, provide data and model validation for plasma interfaces in the HED regime. Our experiments measure mixing-layer width at an unstable interface in the plasma regime and are specifically designed to challenge mix models of the Reynolds-Averaged-Navier-Stokes (RANS) type where turbulence is assumed to be fully developed, i.e. the flow exhibits a broad spectrum of length scales without memory of the initial condition.4 We utilize precise control of the initial interface conditions (densities on both sides of the interface, an initial rippled perturbation pattern consisting of equally weighted wavelengths between 10 and 20 microns, and initial material compositions) along with a repeatable drive history

36 MATERIALS SCIENCE↗

Mixed Element Microparticle Characterization by Electron Probe Microanalysis

Abstract Microparticle compositional characterization for nuclear forensics has traditionally been achieved by “gold-standard” destructive analytical techniques such as large geometry-secondary ion mass spectrometry and fission track-thermal ionization mass spectrometry, but long processing times and total sample consumption eliminate the option of subsequent analysis by other methods. Electron probe microanalysis has long been widely employed for rapid, nondestructive, micrometer-scale compositional measurements and imaging in fields such as material science and geology and may therefore need to be reevaluated as an alternative tool for microparticle analysis for the nuclear forensics community. This study presents the use of electron probe microanalysis for imaging and quantitative characterization of homogeneous microparticles utilizing a calibration curve based on high-precision quadrupole-inductively coupled plasma-mass spectrometry analyses. Samples of opportunity synthesized at Savannah River National Laboratory, nickel-doped cerium oxide microparticles, were selected as analogs for plutonium-doped uranium oxide microparticles. Positive detection and accurate quantification of variable amounts of nickel dopant down to trace levels (10s of parts per million) suggest applicability of this technique to other mixed element systems (e.g., actinides). Quantitative single-particle characterization via electron probe microanalyzer may thus provide a high fidelity, nondestructive complement to techniques currently in use.

Riche, Alexis T. (ORCID:0009000121978126)↗

Hole Trapping in Halide Perovskites Induces Phase Segregation

Metal halide perovskites have garnered a great deal of attention for their applications in photovoltaics, LEDs, and radiation detection. The ease of solution processing high-quality perovskite semiconductors with large absorption coefficients and tolerance to native defects is decidedly attractive. Additionally, the ability to precisely tune the band gap of halide perovskites through compositional alloying of the halide ion is of particular interest for a range of applications, especially for tandem solar cells. However, under steady state light irradiation, an initially homogeneous mixed halide perovskite (MHP) will form local domains that are rich in one halide ion (e.g., Br or I). This light-induced phase segregation in MHPs forms iodide-rich domains that act as charge carrier traps and lowers the efficiency of perovskite-based devices. Thus, phase segregation poses a serious challenge to the implementation of MHPs in real-world device settings. Interestingly, when a phase segregated MHP film is placed in the dark, entropic driving forces become dominant and the segregated perovskite remixes and returns to its initially homogeneous state. Several key mechanistic details of phase segregation have been elucidated over the years. However, there are still aspects of halide segregation that are not clear, and there is ongoing debate in the literature as to what are the key factors that contribute to the mechanism. This Account discusses recent results that point to the specific role of hole trapping in phase segregation. Interestingly, generation of holes through above-band-gap excitation or through electrochemical injection increases ion migration and leads to phase segregation. The thermodynamic and redox properties of halide perovskites provide a strong driving force for hole trapping and oxidation of iodide species in MHPs. However, mobile halide species within the perovskite lattice take time to migrate and generate halide-rich domains. When in contact with a nonpolar solvent, the migration of iodine species is further extended to expulsion of iodine from the perovskite film. Thus, the mobility of halides and their susceptibility to hole-induced oxidation play a crucial role in determining the long-term stability of metal halide perovskites. Strategies to gain kinetic control over ion migration to slow phase segregation are needed to overcome these hurdles and achieve stable mixed halide perovskites. Modification of the perovskite composition through introduction of different cations or halide ions, or introduction of low-dimensional perovskite phases may suppress phase segregation. Furthermore, in achieving stability and improving the efficiency of perovskite solar cells and light emitting devices with minimal impacts, suppression of segregation remains the key factor.

36 MATERIALS SCIENCE↗

Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS

This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm 2 ), and delivers solvent (2% HNO 3 ) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition ( 240 Pu/ 239 Pu and 242 Pu/ 239 Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240 Pu/ 239 Pu ratio on all three CRMs and <10% for the 242 Pu/ 239 Pu ratio on CRM 136 and 138. Here, the percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240 Pu/ 239 Pu and <15% for the 242 Pu/ 239 Pu. Method limits of detection were determined, based on measurements of an enriched 244 Pu material, to be ~7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vertical column dual-comb spectroscopy to a TBS

Open-path dual-frequency-comb spectroscopy (DCS) is a broadband, high spectral resolution, and high precision method for measuring gas concentrations over kilometer-scale paths. It has been used for detection and quantification of emissions of pollutants, hazardous gasses, and greenhouse gasses (GHGs). DCS has been shown to measure trace-gas mixing ratios with 0.14%-0.4% agreement between instruments. To achieve high signal-to-noise ratios (SNRs) with DCS, comb light is targeted onto a retroreflector at the end of the measurement path, which returns the signal to a detector co-located with the launch signal. Installing the retroreflector on a mobile platform such as a balloon or unmanned aerial vehicle (UAV) extends the capabilities of DCS by enabling variable path lengths, greater mobility, and access to higher altitudes. Mobile-target DCS has many uses in plume and leak detection, emissions modeling, and planetary boundary layer (PBL) studies. It is a promising method for observing vertical distributions of GHGs and mixing processes in the PBL, which are difficult to measure but important for pollution and climate monitoring as well as for understanding transport of gasses through the atmosphere. Tethered balloons are an intriguing platform because they enable longer flight durations and higher altitudes than easily obtainable with a UAV and thus allow for column measurements up to and above the PBL. New measurements completed in October/November 2024 reach the highest altitudes above ground level yet achieved by mobile-target DCS. For these measurements, the retroreflector was mounted on a 7 m diameter tethered helium balloon. An actively tracking gimbal on the ground holds the DCS launch telescope and keeps the 5 cm beam pointed onto the retroreflector while the balloon is lifted, lowered, and moved by wind and turbulence.

atmosphere↗

Measurements to determine the location of the phase center of geoceiver antennas - Unofficial summary of results

In Doppler positioning systems, the basic method of point positioning involves a stable transmitted satellite signal received by a ground based antenna and receiver. This received frequency is mixed with a locally generated reference frequency, resulting in a beat frequency. A Doppler equation has been developed which includes all known contributions to this Doppler count. Upon measuring this count at the receiver and by using the precise orbital position of the transmitting satellite, the position of a receiver antenna can be calculated. However, for geodetic accuracy, it is assumed that the receiver antenna is stationary and has a predictable constant phase reference point. Thus, if a phase variation does exist, it may be misinterpreted as an added Doppler shift due to range change.

Larsen, R. K.↗

The Energetic Trans-Iron Composition Experiment (ENTICE) on the Heavy Nuclei Explorer (HNX) Mission

The ENTICE experiment is one of two instruments that make up the HNX mission. The experimental goal of ENTICE is to measure with high precision the elemental abundances of all nuclei with Z between 10 and 82. This will enable us to determine if the injection mechanism for the cosmic ray accelerator is controlled by FIP or Volatility and to study the mix of nucleosynthetic processes that contribute to the galactic cosmic ray source. The ENTICE experiment utilizes the dE/dx-C method of charge determination and consists of silicon dE/dx detectors, Cherenkov detectors with two different refractive indices, and a fiber hodoscope. We will describe the instrument and its performance based on beam tests of a prototype instrument.

Israel, M. H.↗