Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mirror assembly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Improvements in Reflected Target Non-intrusive Assessment (ReTNA)

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. In 2022, NREL presented a new indoor optical measurement system to measure fully assembled heliostats during development and on the assembly line for quality assurance purposes, which has undergone significant development in the last year, including the installation of a new, larger laboratory setup. This system, called ReTNA (Reflected Target Non-intrusive Assessment), uses a printed pattern as a deflectometry target. Using printed pattern features as deflectometry targets instead of fringes allows the software to measure the surface slope in two dimensions, eliminating the need to for changing, projected targets. In the last year, NREL's ReTNA tool has been adapted to use a tall, thin target, that only spans one dimension of the mirror, and a camera moving on an automatic track system. We will present these new developments, including the new setup, target patterns, software methodology for fast, automatic optical analysis, and important lessons learned throughout the process. ReTNA results will be compared to established tools, to establish the uncertainty of this new method. ReTNA leverages recent improvements in computer vision and photogrammetry to remove as much careful calibration from the setup process as possible, making the tool low cost, simple, and portable. While it will not achieve the resolution of a fringe deflectometry system, its advantages make it well suited for CSP evaluation, and allow it to fill a different industry need.

concentrating solar power↗

Performance of the Center-Of-Curvature Optical Assembly During Cryogenic Testing of the James Webb Space Telescope

Cryogenic testing of the James Webb Space Telescope (JWST) included center-of-curvature metrology of the 18-segment primary mirror (PM). The Center-of-Curvature Optical Assembly (COCOA) consisted of a multiple-wavelength interferometer, a reflective null, coarse and fine alignment systems, and two displacement measuring interferometer systems. The COCOA enabled alignment and phasing of the segments from millimeter-level errors down to the nanometer level. This paper describes the COCOA, the test setup, the testing performed, and the performance of the COCOA in aligning the PM segments and measuring the final PM wavefront error.

Hadaway, James↗

Development and Test of a Large Aperture $Nb_3Sn$ Cos-Theta Dipole Coil with Stress Management

An innovative stress-management (SM) concept for cos-theta (CT) coils (SMCT coil concept) has been proposed at Fermilab. A large-aperture two-layer Nb3Sn SMCT dipole coil was designed and manufactured to validate and test the SM concept including coil design, fabrication technology, and performance. The first large-aperture SMCT coil (SMCT1) was fabricated and assembled with a small-aperture Nb3Sn coil inside a dipole mirror magnet. SMCT1 coil tests in a dipole mirror structure was performed in two configurations - SMCTM1a with only powered two-layer SMCT1 coil and SMCTM1b with the SMCT coil connected in series with an inner two-layer dipole coil. The test goals are to prove the SMCT coil concept in two-layer and four-layer mirror configurations; demonstrate that the magnet can reach the targeted quench current at the established preload; study magnet training, training memory after thermal cycle, ramp rate and temperature dependences of the magnet quench current; and test the SMCT1 coil quench protection parameters. This paper summarizes the SMCT1 coil design and parameters, the coil main fabrication steps, its assembly in the dipole mirror structure. The results of the SMCTM1a/b mirror test are presented and discussed.

43 PARTICLE ACCELERATORS↗

Actuation of Deformable Mirrors Using Laser Controlled Pistons

Current deformable mirrors used for adaptive optics employ many actuators to adjust the mirror in order to compensate for optical irregularities. These mechanical actuators, which can number in the hundreds for a given mirror, require a significant amount of electrical wires in order to be controlled. The objective of this research is to implement a different type of actuator that can be controlled without the use of wires. The actuator developed employs a laser to quickly heat and expand the air in a closed 'cell'. When the air expands, it pushes a membrane that causes the mirror to move. Creating an array of these cells, and scanning them with a laser can control a deformable mirror. Testing showed that a single cell with a 5 mm diameter and 10 mm in length can deflect a membrane of aluminized Mylar in excess of our minimum requirement of 20 microns. These cells can now be assembled in a 5 x 5 matrix and attached to many small mirrors. An electro-mechanical scanning assembly can be used to aim the laser directly onto individual cells causing the mirror at that location to move.

deformable mirrors↗

Optimization and test of a 120mm LARP Nb3Sn quadrupole coil using magnetic mirror structure

The US-LARP collaboration is developing a new generation of large-aperture high-field quadrupoles based on Nb{sub 3}Sn superconductor for the LHC upgrades. The development and implementation of this new technology involves the fabrication and testing of series of model magnets, coils and other components with various design and processing features. New 120-mm HQ coils made of Rutherford cable, one with an interlayer resistive core, and both with optimized reaction processes, were fabricated and tested using a quadrupole mirror structure under operating conditions similar to those in a real magnet. The coils were instrumented with voltage taps and strain gauges to study the mechanical and quench performance. Quench antenna and temperature gauges were installed in the mirror structure to measure the coil temperature and locate quench origins. This paper presents details of the coil design and fabrication procedures, coil assembly and pre-stress in the quadrupole mirror structure, and coil test results.

43 PARTICLE ACCELERATORS↗

Metrology Mount and Optics Mandrels

This document is the Final Report for NASA Grant NAG8-1198 from NASA Marshall Space Flight Center (MSFC) to the Smithsonian Astrophysical Observatory (SAO). The Grant is entitled "Metrology Mount and Optics Materials." This final report is required by the terms of the Grant. The period of performance was from September 15, 1995 through January 14, 1999. Total funding received by SAO from MSFC for this effort was, $254,000. Mr. Lester Cohen carried out most of the work at SAO, but received limited support from other engineers, technicians, and designers. Dr. Harvey Tananbaum, the Principal Investigator for the grant provided overall direction and work- assessment. The Grant has had two funding augmentations to its basic amount and has, over time, emphasized three different research areas - each of which has been an extension of earlier research. The research activity was in 2 areas: (1) Expert opto-structural studies related to separation mechanics and effects of electro formed nickel X-ray mirrors. and (2) Design, fabrication and evaluation of a low force metrology and assembly station for light weight full shell electroformed X-ray mirrors.

Tananbaum, H.↗

SU-F-T-11: Scintillator Based Quality Assurance Device for HDR Brachytherapy

Purpose: To build a test device for HDR afterloaders capable of checking source positions, times at positions and estimate the activity of the source. Methods: A catheter is taped on a plastic scintillation sheet. When a source travels through the catheter, the scintillator sheet lights up around the source. The sheet is monitored with a video camera, and records the movement of the light spot. The center of the spot on each image on the video provides the source location, and the time stamps of the images can provide the dwell time the source spend in each location. Finally, the brightness of the light spot is related to the activity of the source. A code was developed for noise removal, calibrate the scale of the image to centimeters, eliminate the distortion caused by the oblique view angle, identifying the boundaries of the light spot, transforming the image into binary and detect and calculate the source motion, positions and times. The images are much less noisy if the camera is shielded. That requires that the light spot is monitored in a mirror, rather than directly. The whole assembly is covered from external light and has a size of approximately 17×35×25cm (H×L×W) Results: A cheap camera in BW mode proved to be sufficient with a plastic scintillator sheet. The best images were resulted by a 3mm thick sheet with ZnS:Ag surface coating. The shielding of the camera decreased the noise, but could not eliminate it. A test run even in noisy condition resulted in approximately 1 mm and 1 sec difference from the planned positions and dwell times. Activity tests are in progress. Conclusion: The proposed method is feasible. It might simplify the monthly QA process of HDR Brachytherapy units.

07 ISOTOPE AND RADIATION SOURCES↗

POLARIS-II - An acousto-optic imaging spectropolarimeter for ground-based astronomy

A compact, acousto-optic tunable filter (AOTF) imaging spectropolarimeter for ground based astronomy from 400-1100 nm has been constructed at NASA/GSFC. The key components of this instrument are a TeO2 non-collinear AOTF, CCD camera, and an all-reflective optical relay assembly which uses a single elliptical mirror to produce side-by-side orthogonally polarized spectral images. The instrument was used at the Lowell Observatory 42-inch telescope for 'first light' planetary imaging and measurements of photometric standard stars. Narrow-band images of Saturn near 700 nm appear to show polarization effects which result from multiple scattering by aerosols. The instrument has recently been upgraded in order to integrate the RF drive electronics and eliminate contamination by scattered light. Design of the instrument and some initial results are presented.

Glenar, D. A.↗

Design of a support and foundation for a large lunar optical telescope

Design analysis and considerations are presented for the support structure and the foundation of the 16-m large lunar telescope (LTT). The proposed graphite/magnesium composite hexapod structure will support the 16-m mirror through a gimbal and trunnion assembly, with each hexapod leg consisting of seven 51-mm diameter 2-mm thick tubes bundled together. The foundation consists of three 152-cm diameter spud-can type footings. Results of the finite element analysis of the load-displacement characteristics of the support structure and the foundation are reported.

Chua, Koon M.↗

Corrective Optics For Camera On Telescope

Assembly of tilted, aspherical circularly symmetric mirrors used as corrective optical subsystem for camera mounted on telescope exhibiting both large spherical wave-front error and inherent off-axis astigmatism. Subsystem provides unobscured camera aperture and diffraction-limited camera performance, despite large telescope aberrations. Generic configuration applied in other optical systems in which aberations deliberately introduced into telescopes and corrected in associated cameras. Concept of corrective optical subsystem provides designer with additional degrees of freedom used to optimize optical system.

Macenka, Steven A.↗

Large-Scale Hollow Retroreflectors for Lunar Laser Ranging at Goddard Space Flight Center

Laser ranging to the retroreflector arrays placed on the lunar surface by the Apollo astronauts and the Soviet Luna missions have dramatically increased our understanding of gravitational physics along with Earth and Moon geophysics, geodesy, and dynamics. Although the precision of the range measurements has historically been limited by the ground station capabilities, advances in the APOLLO instrument at the Apache Point facility in New Mexico is beginning to be limited by errors associated with the lunar arrays. We report here on efforts at Goddard Space Flight Center to develop the next generation of lunar retroreflectors. We will describe a new facility that is being used to design, assemble, and test large-scale hollow retroreflectors. We will also describe results from investigations into various bonding techniques used to assemble the open comer cubes and mirror coatings that have dust mitigation properties.

Preston, Alix↗

A Parametric Finite-Element Model for Evaluating Segmented Mirrors with Discrete, Edgewise Connectivity

Since future astrophysics missions require space telescopes with apertures of at least 10 meters, there is a need for on-orbit assembly methods that decouple the size of the primary mirror from the choice of launch vehicle. One option is to connect the segments edgewise using mechanisms analogous to damped springs. To evaluate the feasibility of this approach, a parametric ANSYS model that calculates the mode shapes, natural frequencies, and disturbance response of such a mirror, as well as of the equivalent monolithic mirror, has been developed. This model constructs a mirror using rings of hexagonal segments that are either connected continuously along the edges (to form a monolith) or at discrete locations corresponding to the mechanism locations (to form a segmented mirror). As an example, this paper presents the case of a mirror whose segments are connected edgewise by mechanisms analogous to a set of four collocated single-degree-of-freedom damped springs. The results of a set of parameter studies suggest that such mechanisms can be used to create a 15-m segmented mirror that behaves similarly to a monolith, although fully predicting the segmented mirror performance would require incorporating measured mechanism properties into the model. Keywords: segmented mirror, edgewise connectivity, space telescope

Gersh-Range, Jessica A.↗

SHARPI/PICTURE Sounding Rocket Telescope

The Solar High Angular Resolution Photometric Imager (SHARPI)/Planet Imaging Concept Testbed Using a Rocket Experiment (PICTURE) Sounding Rocket Telescope is described. The topics include: 1) Lightweight precision mirror development; 2) Two sounding rocket concepts sharing a telescope; 3) Optical Telescope Assembly (OTA) overview; 4) PM development program; 5) PM figure testing; 6) Mirror coatings; 7) PM mount and verification; 8) Secondary Mirror (SM); and 9) OTA.

Content, D.↗

Coherent phasing of segmented mirrors

The technical issues associated with a coherently phased segmented mirror can be divided into two types. The first involves the issues of manufacturing the surface quality of the mirror segments themselves (coherent phasing of individual segments). The second involves assembly issues of initializing in 1 G and retaining in 0 G an aggregate segmented mirror (coherent phasing between individual segments). Using a rectangular coordinate system at the vertex of a mirror segment, the rigid body motions are the six translational and rotational degrees of freedom. A first cut primary mirror wavefront error budget is presented. For a minimum operational wavelength of 30 micrometers, the derived values from the budget are: segment surface quality (0.45 micrometers RMS), radius mismatch (50 PPM), segment piston error (1.3 micrometers, segment tip/tilt error (0.6 microrad). Either active or passive segmented mirrors can be addressed, but if the surface quality of the off-axis segment and the radius matching requirements can be passively met, then only segment alignment need be sensed and controlled during operation in orbit. For the active mirror case, dimensional stability of the mirror material during operation is a key factor in establishing the degree of active figure control required.

Jones, Peter A.↗

Concept Study Report: Extreme-Ultraviolet Imaging Spectrometer Solar-B

We propose a next generation Extreme-ultraviolet Imaging Spectrometer (EIS) that for the first time combines high spectral, spatial, and temporal resolution in a single solar spectroscopic instrument. The instrument consists of a multilayer-coated off-axis telescope mirror and a multilayer-coated grating spectrometer. The telescope mirror forms solar images on the spectrometer entrance slit assembly. The spectrometer forms stigmatic spectra of the solar region located at the slit. This region is selected by the articulated telescope mirror. Monochromatic images are obtained either by rastering the solar region across a narrow entrance slit, or by using a very wide slit (called a slot) in place of the slit. Monochromatic images of the region centered on the slot are obtained in a single exposure. Half of each optic is coated to maximize reflectance at 195 Angstroms; the other half to maximize reflectance at 270 Angstroms. The two Extreme Ultraviolet (EUV) wavelength bands have been selected to maximize spectral and dynamical and plasma diagnostic capabilities. Spectral lines are observed that are formed over a temperature range from about 0.1 MK to about 20 MK. The main EIS instrument characteristics are: wavelength bands - 180 to 204 Angstroms; 250 to 290 Angstroms; spectral resolution - 0.0223 Angstroms/pixel (34.3km/s at 195 Angstroms and 23.6 km/s at 284 Angstroms); slit dimensions - 4 slits, two currently specified dimensions are 1" x 1024" and 50" x 1024" (the slot); largest spatial field of view in a single exposure - 50" x 1024"; highest time resolution for active region velocity studies - 4.4 s.

Doschek, George, A.↗

Laser tuners using circular piezoelectric benders

The paper presents the results of an experimental evaluation of a new type of piezoelectric ceramic device designed for use as a laser mirror tuner. Thin plates made from various materials were assembled into a circular bimorph configuration and tested for linearity of movement, maximum travel, and resonant frequency for varying conditions of clamping torque and mirror loading values. Most of the devices tested could accept mirror diameters up to approximately 1.3 cm and maintain a resonant frequency above 2 kHz. Typical mirror translation without measurable tilt was plus or minus 20 micrometers or greater for applied voltages of less than plus or minus 300 V.

Mcelroy, J. H.↗

Using the ISS as a Testbed to Prepare for the Next Generation of Space-Based Telescopes

The ISS provides a unique opportunity to develop the technologies and operational capabilities necessary to assemble future large space telescopes that may be used to investigate planetary systems around neighboring stars. Assembling telescopes in space is a paradigm-shifting approach to space astronomy. Using the ISS as a testbed will reduce the technical risks of implementing this major scientific facility, such as laser metrology and wavefront sensing and control (WFSC). The Optical Testbed and Integration on ISS eXperiment (OpTIIX) will demonstrate the robotic assembly of major components, including the primary and secondary mirrors, to mechanical tolerances using existing ISS infrastructure, and the alignment of the optical elements to a diffraction-limited optical system in space. Assembling the optical system and removing and replacing components via existing ISS capabilities, such as the Special Purpose Dexterous Manipulator (SPDM) or the ISS flight crew, allows for future experimentation and repair, if necessary. First flight on ISS for OpTIIX, a small 1.5 meter optical telescope, is planned for 2015. In addition to demonstration of key risk-retiring technologies, the OpTIIX program includes a public outreach program to show the broad value of ISS utilization.

Ess, Kim↗

Time-resolved spectra of dense plasma focus using spectrometer, streak camera, and CCD combination

A time-resolving spectrographic instrument has been assembled with the primary components of a spectrometer, image-converting streak camera, and CCD recording camera, for the primary purpose of diagnosing highly dynamic plasmas. A collection lens defines the sampled region and couples light from the plasma into a step index, multimode fiber which leads to the spectrometer. The output spectrum is focused onto the photocathode of the streak camera, the output of which is proximity-coupled to the CCD. The spectrometer configuration is essentially Czerny-Turner, but off-the-shelf Nikon refraction lenses, rather than mirrors, are used for practicality and flexibility. Only recently assembled, the instrument requires significant refinement, but has now taken data on both bridge wire and dense plasma focus experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗