Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “millimeter wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Laboratory and astronomical measurement of the millimeter wave spectrum of the ethynyl radical CCH

The N = 0 yields 1 and 1 yields 2 rotational transitions of CCH at 87 and 174 GHz, respectively, have been detected in a laboratory glow discharge in a mixture of He and C2H2. The spectroscopic constants of CCH derived from measurements of the hfs of the transitions agree well with those derived from astronomical observations, confirming the astronomical detection of CCH. As the CCH lines in the Orion Nebula are narrower than the laboratory lines but less certain in rest frequency owing to uncertainty in the radial velocity, the most accurate values for the spectroscopic constants of CCH are obtained from a simultaneous fit of both the laboratory and astronomical data. For the rotation, centrifugal distortion, spin-rotation, and hyperfine constants, respectively, the values found are within 0.006 of 43674.534 MHz, within 0.0008 of 0.1071 MHz, within 0.004 of -62.606 MHz, b = within 0.019 MHz of 40.426, and c is within 0.026 of 12.254 MHz.

Gottlieb, C. A.↗

Tracking antenna arrays for near-millimeter waves

A two-dimensional monolithic array has been developed that gives the elevation and azimuth of point source targets. The array is an arrangement of rows and columns of antennas and bismuth bolometer detectors on a fused quartz substrate. Energy is focused onto the array through a lens placed on the back side of the substrate. At 1.38 mm with a 50 mm diameter objective lens, the array has demonstrated a positioning accuracy of 26 arcmin. In a differential mode this precision improves to 9 arcsec, limited by the mechanics of the rotating stage. This tracking could be automated to a fast two-step procedure where a source is first located to the nearest row and column, and then precisely located by scanning. With signal processing the array should be able to track multiple sources.

Tong, P. P.↗

Image-optimized, frequency-scalable mixers for millimeter-wave applications

A unique IF measurement procedure for evaluating mixer performance and identifying optimum circuit boundary conditions is presented. The technique is applied to a scalable mm-wave single-sideband (image-sum enhanced) mixer design which provides 3.5 to 5 dB typical conversion loss from conventional, packaged devices.

Peterson, D. F.↗

The nature of AFGL 2591 and its associated molecular outflow: Infrared and millimeter-wave observations

The results of infrared photometry from 2 to 160 microns of AFGL and CO(12) observations of its associated molecular cloud and high velocity molecular outflow are presented and discussed. The observed solar luminosity is 6.7 x 10(4) at a distance of 2 kpc. The spectrum of AFGL 2591 is interpreted in the context of a model in which a single embedded object is the dominant source of the infrared luminosity. This object is determined to be surrounded by a compact, optically thick dust shell with a temperature in excess of several hundred degrees kelvin. The extinction to this source is estimated to be between 26 and 50 visual magnitudes. The absolute position of the infrared sources at 10 microns was determined to an accuracy of + or in. This indicates for the first time that the IR source and H2O source are not coincident. The CO(12) observations show the high-velocity molecular flow near AFGL 2591 to be extended, bipolar and roughly centered on the infrared emission. The observations suggest that the red-shifted flow component extends beyond the boundary of the ambient cloud within which AFGL 2591 is embedded. The CO(12) observations also show that AFGL 2591 is embedded in a molecular cloud with an LSR velocity of -5 km/s.

Lada, C. J.↗

Research in millimeter wave techniques

Work on the development of an improved 183 GHz subharmonic mixer was concentrated in two areas. First, there was an improved performance from current mixer body designs by testing different diodes and varying the whisker lengths. Second, there is the design of a new body structure. The whisker and diode pinsare in the same piece of the mixer that holds the substrate, reducing any motion of the parts that form the ohmic contacts of the diodes circuit. The broadband, low loss, quasi-optical diplexer, which is designed for use with a single ended mixer, has been developed. It uses a Gaussian beam waveguide as its transmission medium. The difference between the diplexer and other diplexers is the use of a Fabry Perot parallel plate filter. One is a multichannel radiometer system. Another approach is a quasi-optical RF polarization diplexer and another receiver. Some of the receivers developed were flown in aircraft and degraded considerably because of an LO failure. A technique for adding a 118 GHz channel to the existing Atmospheric Moisture Microwave Scanner radiometer system, using the RF diplexing scheme, is presented.

Forsythe, R. E.↗

A measurement of stratospheric HO2 by ground-based millimeter-wave spectroscopy

Stratospheric perhydroxyl (HO2) was measured by using a sensitive mm-wave receiver to obtain spectroscopic line profiles of three rotational emission lines in the vicinity of 265.8 GHz. The observations were carried out over four days in September-October 1982 at Mauna Kea, Hawaii and yield good agreement with the column density and vertical distribution predicted above 35 km by three representative two-dimensional photochemical models employing JPL 82-57 reaction rates and chemistry. Contrasts between current theoretical predictions and previous observations by Anderson et al. (1981) are pointed out for HO2 in the 28 to 37-km range, along with the difficulty of joining the latter with the present measurements through a monotonically varying vertical profile for HO2. A possible explanation involving strong temporal and spatial variation in stratospheric water vapor content is suggested.

De Zafra, R. L.↗

Communications and logic systems at millimeter wave frequencies

Activities in materials development, lithography, FET experiments, and mixer diode fabrication are reported. In addition, articles are presented which address leakage effects in n-GaAs MESFET's and lateral nonuniform doping in GaAs MESFET's.

Source record↗

Communications and logic systems at millimeter wave frequencies, summary

During the contract period an AsCl3 epitaxial system used to provide buffer layers for FET structures was constructed. A submicron lithographic processes using deep U.V. techniques was developed and, employing these techniques, a working .5 micron gate device was produced. In addition, the development of submicron mixer diodes continued. The gettering of substrates of a technique to improve the mobility of ionimplantated layers was investigated. The result of this experiment showed a correlation between improved hall mobilities and gettered substrates. Finally, several theoretical studies are reported.

Source record↗

Infrared and millimeter-wave observations of the Sharpless 156 molecular cloud

Comprehensive near-infrared, far-infrared, and CO measurements of the Sharpless 156 region reveal five distinct sources embedded in a giant molecular cloud. These embedded sources, which appear to have formed independently within the cloud, form a diverse collection of objects; these include a prestellar condensation, massive stars with associated reflection and emission nebulosity, a bright compact H II region, and possibly even a luminous, post-main-sequence M star. The majority of the cloud has been mapped in (C-12)O and (C-13)O and has been surveyed at 2.2 microns. Also presented are 40-160 micron far-infrared maps and 1-20 micron near-infrared photometry of the active regions along with 6 arcsec resolution 10 micron and 20 micron maps of the central nebula. Inquiry is made into the nature of each source and into the process of star formation for the complex as a whole.

Joy, M.↗

The nature of AFGL 2591 and its associated molecular outflow Infrared and millimeter-wave observations

The results of infrared photometry from 2 to 160 microns of AFGL and CO(12) observations of its associated molecular cloud and high velocity molecular outflow are presented and discussed. The observed solar luminosity is 6.7 x 10(4) at a distance of 2 kpc. The spectrum of AFGL 2591 is interpreted in the context of a model in which a single embedded object is the dominant source of the infrared luminosity. This object is determined to be surrounded by a compact, optically thick dust shell with a temperature in excess of several hundred degrees kelvin. The extinction to this source is estimated to be between 26 and 50 visual magnitudes. The absolute position of the infrared sources at 10 microns was determined to an accuracy of + or - 1 in. This indicates for the first time that the IR source and H2O source are not coincident. The CO(12) observations show the high-velocity molecular flow near AFGL 2591 to be extended, bipolar and roughly centered on the infrared emission. The observations suggest that the red-shifted flow component extends beyond the boundary of the ambient cloud within which AFGL 2591 is embedded. The CO(12) observations also show that AFGL 2591 is embedded in a molecular cloud with an LSR velocity of -5 km/s.

Lada, C. J.↗

Near millimeter wave imaging/multi-beam integrated antennas

This report describes the most recent work on the theory of single element Linearly Tapered Slot Antennas (LTSAs) and Constant Width Slot Antennas (CWSAs). The radiation mechanism for these is presently well understood and allows quantitative calculation of beamwidths and sidelobe levels, provided that the antennas have a sufficiently wide conducting region on either side of the tapered slot. Appendices 4 to 7 represent earlier work on the grant. This work further elucidates the properties of arrays of CWSA elements, and the effects of coupling on the beam-shape. It should be noted that typical beam-efficiencies of 65% have been estimated, and that element spacings of about one Rayleigh unit are possible. Further, two-point resolution at the Rayleigh spacing has been demonstrated for a CWSA array in a 30.4 cm paraboloid at 31 GHz. These results underscore that interest in further studies of the radiation mechanism of tapered slot arrays. Appendix 7 constitutes a final, detailed report on the work leading to a 94 GHz seven element LTSA array imaging system, which has been reported previously in less detail. Experimental results are presented.

Yngvesson, K. S.↗

A class of optically controlled millimeter wave devices

Three specific devices were investigated: the sheet resistance device, the Schottky-barrier diode and the PIN diode. Several sheet resistance devices were fabricated and tested. Based on the encouraging results from these devices, a mask was designed and sent to a vendor and is expected to be received very soon. A set of masks for fabricating transparent cathode Schottky-barrier diodes was designed. These masks were given to NASA Goddard Space Flight Center for fabrication of the diodes. A mask set was designed to fabricate PIN diodes with transparent electrodes. With slight modifications, the same mask set also can be used to fabricate other devices, such as MESFET and the IMPATT diode.

Chowdhary, R.↗

Submillimeter and millimeter wave characterization of absorbing materials

Several microwave absorbers have been characterized in terms of transmittance and reflectance at frequencies between 35 GHz and 3 THz. The materials studied were a series of iron-loaded cast epoxy absorbers known as Eccosorb. Measurements show that reflectance and absorption coefficient increase with the iron density. A dramatic decrease, by as much as a factor of 2, in absorption coefficient was observed when the samples were cooled from ambient to cryogenic temperatures. A blackbody calibrator to be operated at liquid helium temperature was constructed using the measured optical constants for these absorbers. The measured absorption coefficient for cold Eccosorb CR-110 is within 20 percent of that reported recently by Peterson and Richards.

Hemmati, H.↗

An upward looking airborne millimeter wave radiometer for atmospheric water vapor sounding and rain detection

A 90/180 GHz multichannel radiometer is currently under development for NASA's 1985 Hurricane Mission onboard the Convair 990 research aircraft. The radiometer will be a fixed beam instrument with dual corrugated horns and a common lens antenna designed to operate simultaneously at 90 and 180 GHz. The all solid state front-end will contain three double side band data channels at 90 + or - 3 GHz, 180 + or - 3 GHz, and 180 + or - 7 GHz. The airborne radiometer will mount in a window port on the CV-990 and will maintain a fixed beam view approximately 14 degrees off zenith. The radiometer design is a Dicke chopper arrangement selected to achieve maximum absolute temperature accuracy and minimum brightness temperature sensitivity. Analog outputs of the three data channels will be calibrated dc voltages representing the observed radiometric brightness temperatures over the selected integration time.

Gagliano, J. A.↗

Millimeter-wave imaging sensor data evaluation

A passive 3-mm radiometer system with a mechanically scanned antenna was built for use on a small aircraft or an Unmanned Aerial Vehicle to produce real near-real-time, moderate-resolution (0.5) images of the ground. One of the main advantages of this passive imaging sensor is that it is able to provide surveillance information through dust, smoke, fog and clouds when visual and IR systems are unusable. It can also be used for a variety of remote sensing applications, such as measurements of surface moisture, surface temperature, vegetation extent and snow cover. It is also possible to detect reflective objects under vegetation cover.

Wilson, William J.↗

Complex dielectric constants for selected near-millimeter-wave materials at 245 GHz

A double-beam instrument developed in this laboratory has been used to measure the complex dielectric constant of selected materials at 245 GHz. It is reported here the results for crystalline quartz, fused silica (Spectrosil WF and Dynasil 4000), beryllia (iso-pressed), boron nitride (hot-pressed), and a nickel ferrite (Trans-Tech 2-111). Results are compared with the data obtained by other researchers.

Dutta, J. M.↗

A search for the millimeter-wave transitions of CO(+) in Comet P/Halley

Although no detection was obtained in the present search for the N = 2-1, J = 5/2-3/2, and J = 3/2-1/2 mm-wave transitions of CO(+) in Comet P/Halley, a 2-sigma upper limit of 8 x 10 to the 11th/sq cm was determined for the beam-averaged column density of this specie. Upon comparison of this upper limit estimate with model predictions involving the variation of such parameters as the chemical composition and ionization mechanisms, it appears that H2O may be the main nucleus constituent of the comet. If, in addition, photodissociation ionization is active in the coma, then the origin of the CO(+) is more likely to be in CO2 than in CO.

Baum, S.↗