Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A Centrifugal Microfluidic Platform That Separates Whole Blood Samples into Multiple Removable Fractions Due to Several Discrete but Continuous Density Gradient Sections

We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. Ultimately, this platform has great potential in both medical diagnostics and research applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing.

47 OTHER INSTRUMENTATION↗

Accessing Fungal Contributions to the Birch Effect: Real-Time Respiration from Pore-Scale Microfluidics

Drying and rewetting of soil stimulates soil carbon emission. The Birch effect, driven by these cycles, leads to CO2 efflux, which can be monitored using real-time mass spectrometry (RTMS). Although soil fungi retain water during droughts, their contribution to CO2 release during drying–rewetting cycles remains unclear. In this study, we present the first demonstration of integrating micromodels with RTMS to monitor the Birch effect by simulating drought and rewetting. Micromodels were inoculated with axenic fungal culture and dried to assess moisture retention. After drying, RTMS quantified CO2 release upon rewetting with H218O mixtures. Our results showed that soil fungi released CO2 upon rehydration and immediately utilized the external water source at the pore scale by generating subsequent 46CO2. This work is the first to integrate RTMS with microsystems to investigate pore-scale biogeochemistry and the involvement of fungi in the Birch effect.

54 ENVIRONMENTAL SCIENCES↗

Beyond BioSentinel: Iterative Development of Automated Microfluidics

NASA Ames has flown a series of Bio-CubeSats that performed biology experiments supported by automated fluidic systems. Since Genesat-1 in 2006, these payloads have increased in complexity and functionality, building upon previous successes, and applying lessons learned. BioSentinel was the most recent of this series, launched into heliocentric orbit onboard Artemis-1 in 2022. This presentation will discuss how the fluidic technology developed for these Bio-CubeSat missions, including the multi-layer polycarbonate manifolds at the heart of the BioSentinel BioSensor, have spurred the development of several additional projects. Most directly is the modified BioSensor that will be a part of LEIA, which will perform its Lunar biology experiment onboard a Commercial Lunar Payload Services lander. Several search-for-life manifolds have been designed to prepare samples from icy moons for downstream analyses. Two early career Polaris projects are developing fluidics to perform genetic sequencing on samples from multigenerational cell culture and to extract and quantify target miRNAs to support astronaut radiation health assessment. Improving the readiness of these systems has been accelerated by adopting the established flight heritage and microgravity-compatibility of the Bio-CubeSat fluidic hardware and designs, while focusing development efforts on the integration of novel functionalities and components.

microfluidics↗

PREPARATION OF CLAY-COATED GLASS SURFACES FOR MICROFLUIDICS-BASED STUDY ON CLAY-FLUID INTERACTIONS

Unique characteristics of clay, even though make any clay abundant shales a good source of adsorbed gas, make them equally difficult to produce. The clay-water interaction can cause significant swelling and fines migration in the shale formation, both of which can significantly impair the overall hydrocarbon recovery from shale. Geomaterial micromodels, developed by functionalizing traditional glass or PDMS surface with geomaterials (e.g., calcite, quartz, clay) can represent the physico-chemical properties of the natural porous media and have been used during the last few years to understand and evaluate the solid-fluid physicochemical interactions. This study focuses on developing a clay-coated geomaterial surface and investigates the effect of base fluid's salinity on clay adsorption to the glass surface. Glass capillary tubes and straight channel borosilicate glass micromodels are coated with Illite clay minerals to represent the pore-scale clay chemistry of Caney Shale, a Mississippian unconventional play in Southern Oklahoma, USA. 10 wt.% of Illite clay slurries made with brines of four different salinities are used to coat the glass-capillary tubes to understand the effect of salinity in clay adsorption on the glass surface and overall coating quality. To achieve a stable coating and evaluate the impact of heat treatment on coating's stability, straight channel glass flow cells coated with Illite clay are heat-treated at low (25 °C) and high temperature (125 °C). Dynamic flooding tests were carried out with brines on the coated surface to evaluate the stability of the coating. The experiments' outcome indicated a strong relationship between the brine's salinity and the adsorption of clay particles on the glass surface. An increase in brine concentration resulted in improved adsorption of clay particles on the glass surface. Experiments involving heat treating the glass surface following the coating demonstrated significant improvement in the stability of the coating.

02 PETROLEUM↗

Proteomic Analysis of Single Mammalian Cells Enabled by Microfluidic Nanodroplet Sample Preparation and Ultrasensitive NanoLC-MS

We report on the quantitative proteomic analysis of single mammalian cells. Fluorescence-activated cell sorting was used to deposit cells into a nanodroplet system for proteomic sample preparation. After processing, samples were analysed by ultrasensitive nanoLC-MS. Using this platform, an average of ~670 protein groups were identified from single HeLa cells and ~330 proteins were quantifiable. We demonstrated the single cell proteomics platform can be used to differentiate cell types from enzyme-dissociated primary cells from human lung and identify specific protein marker among them.

Zhu, Ying↗

Design and optimization of a fused-silica microfluidic device for separation of trivalent lanthanides by isotachophoresis

Abstract Elemental analysis of rare earths is essential in a variety of fields including environmental monitoring and nuclear safeguards; however, current techniques are often labor intensive, time consuming and/or costly to perform. The difficulty arises in preparing samples, which requires separating the very chemically and physically similar lanthanides. However, by transitioning these separations to the microscale, the speed, cost, and simplicity of sample preparation can be drastically reduced. Here, all fourteen non radioactive lanthanides (lanthanum through lutetium minus promethium) are separated by ITP in a serpentine fused silica microchannel in < 10 minutes with limits of detection on the order of picomoles. Electrophoretic electrodes are embedded in the microchip reservoirs so that voltage can be quickly applied and switched during operation. The limits of detection are quantified using a commercial C4D to calculate ITP zone lengths in combination with ITP theory. Optimization of experimental procedures and reproducibility based on statistical analysis of subsequent experimental results are addressed.

Bottenus, Daniel R.↗