Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

One-way Doppler extractor

This paper presents a feasibility analysis, tradeoffs, and implementation for a one-way Doppler extractor system. A Doppler error analysis is discussed which shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared, and a 'Vernier' technique is presented which obtains high Doppler resolution with low-speed logic. Parameter tradeoffs and sensitivities for this Vernier technique are discussed, leading to a hardware design configuration. Also presented is a performance evaluation of the resulting breadboard model that verifies the theoretical performance predictions. The breadboard model contains the circuitry to interface with an S-band transponder, to extract the Doppler and time-interval counts, to compute navigational parameters by means of a microprocessor, and to display the results. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of better than 0.02 hertz for a one-second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.

Nossen, E. J.↗

Water vapor measurement system in global atmospheric sampling program, appendix

The water vapor measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available dew/frostpoint hygrometer with a thermoelectrically cooled mirror sensor. The modifications extended the range of the hygrometer to enable air sample measurements with frostpoint temperatures down to -80 C at altitudes of 6 to 13 km. Other modifications were made to permit automatic, unattended operation in an aircraft environment. This report described the hygrometer, its integration with the GASP system, its calibration, and operational aspects including measurement errors. The estimated uncertainty of the dew/frostpoint measurements was + or - 1.7 Celsius.

Englund, D. R.↗

Psychophysical rating of image compression techniques

Image compression schemes abound with little work which compares their bit-rate performance based on subjective fidelity measures. Statistical measures of image fidelity, such as squared error measures, do not necessarily correspond to subjective measures of image fidelity. Most previous comparisons of compression techniques have been based on these statistical measures. A psychophysical method has been used to estimate, for a number of compression techniques, a threshold bit-rate yielding a criterion level of performance in discriminating original and compressed images. The compression techniques studied include block truncation, Laplacian pyramid, block discrete cosine transform, with and without a human visual system scaling, and cortex transform coders.

Stein, Charles S.↗

Parallel computers - Estimate errors caused by imprecise data

A new approach to the problem of estimating errors caused by imprecise data is proposed in the context of software engineering. A software device is used to produce an ideal solution to the problem, when the computer is capable of computing errors of arbitrary programs. The software engineering aspect of this problem is to describe a device for computing the error estimates in software terms and then to provide precise numbers with error estimates to the user. The feasibility of the program capable of computing both some quantity and its error estimate in the range of possible measurement errors is demonstrated.

Kreinovich, Vladik↗

The effect of sensor sheltering and averaging techniques on wind measurements at the Shuttle Landing Facility

This document presents results of a field study of the effect of sheltering of wind sensors by nearby foliage on the validity of wind measurements at the Space Shuttle Landing Facility (SLF). Standard measurements are made at one second intervals from 30-feet (9.1-m) towers located 500 feet (152 m) from the SLF centerline. The centerline winds are not exactly the same as those measured by the towers. A companion study, Merceret (1995), quantifies the differences as a function of statistics of the observed winds and distance between the measurements and points of interest. This work examines the effect of nearby foliage on the accuracy of the measurements made by any one sensor, and the effects of averaging on interpretation of the measurements. The field program used logarithmically spaced portable wind towers to measure wind speed and direction over a range of conditions as a function of distance from the obstructing foliage. Appropriate statistics were computed. The results suggest that accurate measurements require foliage be cut back to OFCM standards. Analysis of averaging techniques showed that there is no significant difference between vector and scalar averages. Longer averaging periods reduce measurement error but do not otherwise change the measurement in reasonably steady flow regimes. In rapidly changing conditions, shorter averaging periods may be required to capture trends.

Merceret, Francis J.↗

Uncertainty quantification and error analysis

UQ studies all sources of error and uncertainty, including: systematic and stochastic measurement error; ignorance; limitations of theoretical models; limitations of numerical representations of those models; limitations on the accuracy and reliability of computations, approximations, and algorithms; and human error. A more precise definition for UQ is suggested below.

99 GENERAL AND MISCELLANEOUS↗

Infusing Statistical Thinking into the NASA Quesst Community Test Campaign

Statistical thinking permeates many important decisions as NASA plans its Quesst mission, which will culminate in a series of community overflights using the X-59 aircraft to demonstrate low-noise supersonic flight. Month-long longitudinal surveys will be deployed to assess human perception and annoyance to this new acoustic phenomenon. NASA works with a large contractor team to develop systems and methodologies to estimate noise doses, to test and field socio-acoustic surveys, and to study the relationship between the two quantities, dose and response, through appropriate choices of statistical models. This latter dose-response relationship will serve as an important tool as national and international noise regulators debate whether overland supersonic flights could be permitted once again within permissible noise limits. In this presentation we highlight several areas where statistical thinking has come into play, including issues of sampling, classification and data fusion, and analysis of longitudinal survey data that are subject to rare events and the consequences of measurement error. We note several operational constraints that shape the appeal or feasibility of some decisions on statistical approaches, and we identify several important remaining questions to be addressed.

Bayesian model↗

Uncertainty Analysis of Seebeck Coefficient and Electrical Resistivity Characterization

In order to provide a complete description of a materials thermoelectric power factor, in addition to the measured nominal value, an uncertainty interval is required. The uncertainty may contain sources of measurement error including systematic bias error and precision error of a statistical nature. The work focuses specifically on the popular ZEM-3 (Ulvac Technologies) measurement system, but the methods apply to any measurement system. The analysis accounts for sources of systematic error including sample preparation tolerance, measurement probe placement, thermocouple cold-finger effect, and measurement parameters; in addition to including uncertainty of a statistical nature. Complete uncertainty analysis of a measurement system allows for more reliable comparison of measurement data between laboratories.

Seebeck effect↗

Bias Reduction and Filter Convergence for Long Range Stereo

We are concerned here with improving long range stereo by filtering image sequences. Traditionally, measurement errors from stereo camera systems have been approximated as 3-D Gaussians, where the mean is derived by triangulation and the covariance by linearized error propagation. However, there are two problems that arise when filtering such 3-D measurements. First, stereo triangulation suffers from a range dependent statistical bias; when filtering this leads to over-estimating the true range. Second, filtering 3-D measurements derived via linearized error propagation leads to apparent filter divergence; the estimator is biased to under-estimate range. To address the first issue, we examine the statistical behavior of stereo triangulation and show how to remove the bias by series expansion. The solution to the second problem is to filter with image coordinates as measurements instead of triangulated 3-D coordinates.

robotics↗

A source of experimental underestimation of aerosol bolus deposition

We examined the measurement error in inhaled and exhaled aerosol concentration resulting from the bolus delivery system when small volumes of monodisperse aerosols are inspired to different lung depths. A laser photometer that illuminated approximately 75% of the breathing path cross section recorded low inhaled bolus half-widths (42 ml) and negative deposition values for shallow bolus inhalation when the inhalation path of a 60-ml aerosol was straight and unobstructed. We attributed these results to incomplete mixing of the inhaled aerosol bolus over the breathing path cross section, on the basis of simultaneous recordings of the photometer with a particle-counter sampling from either the center or the edge of the breathing path. Inserting a 90 degrees bend into the inhaled bolus path increased the photometer measurement of inhaled bolus half-width to 57 ml and yielded positive deposition values. Dispersion, which is predominantly affected by exhaled bolus half-width, was not significantly altered by the 90 degrees bend. We conclude that aerosol bolus-delivery systems should ensure adequate mixing of the inhaled bolus to avoid error in measurement of bolus deposition.

Non-NASA Center↗

Contextual subspace variational quantum eigensolver calculation of the dissociation curve of molecular nitrogen on a superconducting quantum computer

Abstract We present an experimental demonstration of the Contextual Subspace Variational Quantum Eigensolver on superconducting hardware. Calculating the potential energy curve of molecular nitrogen proves challenging for many conventional quantum chemistry techniques, since static correlation dominates in the dissociation limit. Our quantum simulations retain good agreement with the Full Configuration Interaction energy, outperforming all benchmarked single-reference wavefunction techniques in capturing the bond-breaking appropriately. Moreover, our methodology is competitive with multiconfigurational approaches but at a saving of quantum resource, meaning larger active spaces can be treated for a fixed qubit allowance. To achieve this result, we deploy an error mitigation/suppression strategy comprised of Dynamical Decoupling, Measurement-Error Mitigation and Zero-Noise Extrapolation. Circuit parallelization also provides passive noise-averaging and improves the effective shot yield to reduce the measurement overhead. Furthermore, we introduce a modified adaptive ansatz construction algorithm that incorporates hardware awareness into our variational circuits, minimizing the transpilation cost for the target qubit topology.

Physics↗

Accuracy of earth albedo estimates from wide-angle radiation measurements

The instantaneous resolution and accuracy that can be expected from two inversion techniques to be used in the Earth Radiation Budget Experiment (ERBE) are examined. It is shown that measurement errors are magnified by the numerical filter and that this magnification is a function of the magnitude of the inversion factor. By using singular value decomposition, these magnitudes can be reduced to improve the estimates. A simulation of the estimation process using an albedo field derived from scanning radiometer data shows that retaining 6 of the 13 singular values gives the best results. If there are no bidirectional model errors the medium-field-of-view data give the best estimates. However, when bidirectional model errors are considered, the wide-field-of-view measurements give better estimates since they are less sensitive to these errors.

Green, R. N.↗

Dual-axis hole-drilling ESPI residual stress measurements

A novel dual-axis ESPI hole-drilling residual stress measurement method is presented. The method enables the evaluation of all the in-plane normal stress components with similar response to measurement errors, significantly lower than with single-axis measurements. A numerical method is described that takes advantage of, and compactly handles, the additional optical data that are available from the second measurement axis. Experimental tests were conducted on a calibrated specimen to demonstrate the proposed method, and the results supported theoretical expectations.

42 ENGINEERING↗

A curved edge diffraction-utilized displacement sensor for spindle metrology

This paper presents a new dimensional metrological sensing principle for a curved surface based on curved edge diffraction. Spindle error measurement technology utilizes a cylindrical or spherical target artifact attached to the spindle with non-contact sensors, typically a capacitive sensor (CS) or an eddy current sensor, pointed at the artifact. However, these sensors are designed for flat surface measurement. Therefore, measuring a target with a curved surface causes error. This is due to electric fields behaving differently between a flat and curved surface than between two flat surfaces. In this study, a laser is positioned incident to the cylindrical surface of the spindle, and a photodetector collects the total field produced by the diffraction around the target surface. The proposed sensor was compared with a CS within a range of 500 μm. The discrepancy between the proposed sensor and CS was 0.017% of the full range. Its sensing performance showed a resolution of 14 nm and a drift of less than 10 nm for 7 min of operation. This sensor was also used to measure dynamic characteristics of the spindle system (natural frequency 181.8 Hz, damping ratio 0.042) and spindle runout (22.0 μm at 2000 rpm). The combined standard uncertainty was estimated as 85.9 nm under current experiment conditions. It is anticipated that this measurement technique allows for in situ health monitoring of a precision spindle system in an accurate, convenient, and low cost manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving multiwell petrophysical interpretation from well logs via machine learning and statistical models

Well-log interpretation estimates in situ rock properties along well trajectory, such as porosity, water saturation, and permeability, to support reserve-volume estimation, production forecasts, and decision making in reservoir development. However, due to measurement errors, variability of well logs caused by multiple measurement vendors, different borehole tools, and nonuniform drilling/borehole conditions, estimations of rock properties with original well logs without proper preprocessing may not be accurate, especially in the context of multiwell estimation. Well-log normalization techniques such as two-point scaling and mean-variance normalization are commonly used to improve the robustness of multiwell rock-property estimation. However, these techniques do not consider the correlation between well logs and require subjective knowledge for their effective implementation. To reduce uncertainties and processing time associated with multiwell rock-property estimation from well logs, we develop discriminative adversarial (DA) and linear constraint models for well-log normalization and rock-property estimation. The DA neural network model developed for well-log normalization and interpretation can perform linear and nonlinear well-log normalization while considering the joint distribution of each well log and rock properties. However, the linear constraint model uses an ensemble of predictions from linear models to constrain well-log normalization and rock-property estimation. We also develop a divergence-based type well identification method to select type (training) wells for a test well based on the statistical similarity of associated well-log distributions instead of the interwell distance. We apply the DA model to perform well-log normalization and prediction of permeability for the Seminole San Andres Unit carbonate reservoir. Compared with the permeability predicted with the classical machine learning model without well-log normalization and models with two-point scaling normalization, the DA model yields the most accurate permeability prediction by decreasing the mean-squared error of permeability prediction by 20%–50%.

Geochemistry & Geophysics↗

Single-Shot Decoding of Good Quantum LDPC Codes

Abstract Quantum Tanner codes constitute a family of quantum low-density parity-check codes with good parameters, i.e., constant encoding rate and relative distance. In this article, we prove that quantum Tanner codes also facilitate single-shot quantum error correction (QEC) of adversarial noise, where one measurement round (consisting of constant-weight parity checks) suffices to perform reliable QEC even in the presence of measurement errors. We establish this result for both the sequential and parallel decoding algorithms introduced by Leverrier and Zémor. Furthermore, we show that in order to suppress errors over multiple repeated rounds of QEC, it suffices to run the parallel decoding algorithm for constant time in each round. Combined with good code parameters, the resulting constant-time overhead of QEC and robustness to (possibly time-correlated) adversarial noise make quantum Tanner codes alluring from the perspective of quantum fault-tolerant protocols.

97 MATHEMATICS AND COMPUTING↗

Off-line tracking of series parameters in distribution systems using AMI data

Electric distribution systems have historically lacked measurement points, and equipment is often operated to its failure point, resulting in customer outages. The widespread deployment of sensors at the distribution level is enabling observability. This paper presents an off-line parameter value tracking procedure that takes advantage of the increasing number of measurement devices being deployed at the distribution level to estimate changes in series impedance parameter values over time. The tracking of parameter values enables non-diurnal and non-seasonal change to be flagged for investigation. The presented method uses an unbalanced Distribution System State Estimation (DSSE) and a measurement residual-based parameter estimation procedure. Measurement residuals from multiple measurement snapshots are combined in order to increase the effective local redundancy and improve the robustness of the calculations in the presence of measurement noise. Data from devices on the primary distribution system and from customer meters, via an AMI system, form the input data set. Results of simulations on the IEEE 13-Node Test Feeder are presented to illustrate the proposed approach applied to changes in series impedance parameters. A 5% change in series resistance elements can be detected in the presence of 2% measurement error when combining less than 1 day of measurement snapshots into a single estimate.

Williams, Tess L.↗