Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Design of high-performance guns for the HL-LHC HEL

The High Luminosity LHC project (HL-LHC) foresees the construction and installation of important new equipment to increase the performance of the LHC machine. The Hollow Electron Lens (HEL) is a promising system to control the beam halo. It improves the beam collimation system of the HL-LHC and mitigates possible equipment damage in case of failure scenarios from halo losses. The halo can store up to 30 MJ energy. The specifications for this new device are quite demanding. The source, an electron gun with an annular shaped cathode, must deliver a current up to 5 A. Additionally, this is five times higher than the current in the existing electron lenses in Fermi and Brookhaven national laboratories. This note describes the programme carried out to design and test high-perveance guns equipped with two types of high-performance scandate cathodes. The size of the final gun for the HL-LHC lenses is now considerably smaller than the one of the first prototype, allowing a reduction of diameter and cost of the superconducting magnet system used to steer the electron beam. The tests carried out at FNAL, BVERI and BJUT demonstrated that the developed cathodes fulfil the specifications and can supply a 5 A fully Space Charge Limited (SCL) current.

43 PARTICLE ACCELERATORS↗

Quasisymmetric Optimization of Nonaxisymmetry in Tokamaks

Predictive 3D optimization reveals a novel approach to modify a nonaxisymmetric magnetic perturbation to be entirely harmless for tokamaks, by essentially restoring quasisymmetry in perturbed particle orbits as much as possible. Such a quasisymmetric magnetic perturbation (QSMP) has been designed and successfully tested in the KSTAR and DIII-D tokamaks, demonstrating no performance degradation despite the large overall amplitudes of nonaxisymmetric fields and strong response otherwise expected in the tested plasmas. The results indicate that a quasisymmetric optimization is a robust path of error field correction across the resonant and nonresonant field spectrum in a tokamak, leveraging the prevailing concept of quasisymmetry for general 3D plasma confinement systems such as stellarators. Finally, the optimization becomes, in fact, a simple eigenvalue problem to the so-called torque response matrices if a perturbed equilibrium is calculated consistent with nonaxisymmetric neoclassical transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental, numerical and analytical evaluation of j × B -thrust for fast-liquid-metal-flow divertor systems of nuclear fusion devices

Abstract Divertor systems of fusion devices are exposed to intense heat loads from plasmas, which degrade solid plasma-facing components. Fast liquid metal (LM) flow divertors may be more advantageous for this purpose but have risk of piling due to intense magnetohydrodynamic (MHD) drag. However, severe deceleration of the flow could be countered with the injection of currents that are transverse to external magnetic fields, allowing to thrust the flow with j × B (Lorentz) forces. Given that the injection of currents as an approach to propel LM-divertor flows has remained experimentally understudied, this article focuses on the evaluation of j × B -thrust and finding its drawbacks. j × B -thrust was experimentally tested with free-surface-LM flows, a vertical magnetic field and an externally applied current. Experiments were reviewed with a theoretical model, showing agreement in the trends of theory and experiments. Full 3D-MHD-free-surface-flow simulations were also performed with FreeMHD and confirmed the sensitivity to unstable flow behavior in LM systems when applying external currents. Furthermore, excessive power requirements are expected for the implementation of j × B -thrust at the reactor scale, making these systems inefficient for commercial devices. This paper evidences that the simple operation of a LM-flow divertor with j × B -thrust, without any of the instabilities caused from reactor plasmas or parasitic currents, already presents intrinsic challenges.

Magnetohydrodynamics↗

U.S. HL-LHC Accelerator Upgrade Project: Q1/Q3 Cryostat Assembly and Horizontal Test (Final Design Report)

The Inner Triplet (IT) quadrupoles are the magnetic system for reaching low beta functions around the Interaction Point (IP). The triplet is made of three optical elements: Q1, Q2, and Q3. The upgrade of the Inner Triplets in the high luminosity insertions is the cornerstone of the LHC upgrade. The decision for HL-LHC heavily relies on the success of the advanced Nb 3 Sn technology that provides access to magnetic fields well beyond 9 T, allowing the maximization of the aperture of the IT quadrupoles. A 15-year-long study led by the DOE in the US under the auspices of the U.S. LARP program, and lately by other EU programs, has shown the feasibility of Nb 3 Sn accelerator magnets. The HL-LHC is expected to be the first application of accelerator-quality Nb 3 Sn magnet technology in an operating particle accelerator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of hydrogen on tensile properties of 304L stainless steel at cryogenic temperatures

Safe and efficient hydrogen storage and distribution are key attributes to realizing hydrogen as an alternative energy carrier. To this end, cryogenic liquid and cryo-compressed gaseous hydrogen are considered high energy density alternatives to ambient temperature gas. However, these alternatives have significant material demands to overcome extreme temperature (20 K) and pressure (700 bar) as well as hydrogen effects. Austenitic stainless steels are widely used for cryogenic pressure vessels owing to relatively high ductility even at 4 K. However, the influence of hydrogen on mechanical properties at cryogenic temperatures has rarely been studied. In this study, the tensile properties of 304L austenitic stainless steel with internal hydrogen were evaluated at 20 K, 77 K, and 113 K. Test specimens were saturated with internal hydrogen to concentration of 140 wtppm in a high pressure environment at elevated temperature, a process called thermal precharging. While lower temperature in known to increase strength properties and reduced elongation at fracture, the presence of internal hydrogen increased both strength and elongation at fracture, but reduced ductility. Magnetic evaluation of the uniformly strained region of the test specimens suggest that hydrogen mitigates the strain-induced transformation to a’-martensite. Brittle fracture features and secondary cracking indicative of hydrogen embrittlement were observed on the fracture surfaces of hydrogen-precharged specimens, which is consistent with the loss of ductility.

Merkel, Daniel R.↗

The Low-Beta Quadrupoles for the High-Luminosity Large Hadron Collider: enabling higher luminosity by using Nb_3Sn conductor

The large-aperture, high-gradient Low Beta Quadrupoles for the High Luminosity Large Hadron Collider at CERN are the cornerstones of this collider. They are first-of-the-kind accelerator magnets bringing Nb_3Sn conductor to High Energy Physics colliders. In the US they are being fabricated and tested by the HL-LHC Accelerator Upgrade Project (AUP), and in Europe by CERN. The design was developed by AUP and CERN in close collaboration. The Q1/Q3 cryo-assemblies contain two 4.2 m long magnets (MQXFA) fabricated and by AUP. They are tested vertically before use in a cry-assembly. In this paper we are going to present the main features of the MQXFA design, results of vertical tests, and main lessons learned. We will also discuss lessons learned for future use of Nb_3Sn magnets in HEP colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of self-magnetic pinch radiographic diode performance on RITS-6 at Sandia National Laboratories. II. Coupling between the inductive voltage adder and the SMP load

The self-magnetic pinch (SMP) diode is a type of radiographic diode used to generate an intense electron beam for radiographic applications. At Sandia National Laboratories, SMP was the diode load for the six-cavity radiographic integrated test stand inductive voltage adder (IVA) driver operated in a magnetically insulated transmission line (MITL). The MITL contributes a flow current in addition to the current generated within the diode itself. Extensive experiments with a MITL of 40Ω load impedance [T. J. Renk et al., Phys. Plasmas 29, 023105 (2022)] indicate that the additional flow current leads to results similar to what might be expected from a conventional high-voltage interface driver, where flow current is not present. However, when the MITL flow impedance was increased to 80 Ω, qualitatively different diode behavior was observed. This includes large retrapping waves suggestive of an initial coupling to low impedance as well as diode current decreasing with time even as the total current does not. A key observation is that the driver generates total current (flow + diode) consistent with the flow impedance of the MITL used. The case is made in this paper that the 80Ω MITL experiments detailed here can only be understood when the IVA-MITL-SMP diode is considered as a total system. Additionally, the constraint of fixed total current plus the relatively high flow impedance limits the ability of the diode (whether SMP or other type) to act as an independent load. An unexpected new result is that in tracking the behavior of the electron strike angle on the converter as a function of time, we observed that the conventional cIV x “Radiographic” radiation scaling (where x~2.2) begins to break down for voltages above 8 MV, and cubic scaling is required to recover accurate angle tracking.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring Critical Synthetic Parameters for Nanoscale ε-Fe 2 O 3 and Their Influence on Magnetic Behaviors

An intermediate polymorph of iron oxide, ε-Fe 2 O 3 , has attracted significant attention due to its giant coercive field ( H c ) and potential applications in high-frequency millimeter-wave absorption and high-density magnetic recording. However, the fabrication of ε-Fe 2 O 3 with high phase purity is still a challenge due to complicated synthetic procedures and a large variety of reaction parameters. In this study, we have identified critical reaction parameters to improve the phase purity of ε-Fe 2 O 3 , and the effects of all possible reaction parameters have been tested through systematic studies. A combination of structural and magnetic characterization techniques provides us with an accurate and reliable phase purity analysis of the ε-Fe 2 O 3 phase. Specifically, we observed that (1) the reaction temperature and time and (2) the addition of Ba are critical parameters to improve the phase purity. We identified the optimal conditions that maximize the coercivity and phase purity, giving insight into the effects of each parameter on the γ- to ε- to α-phase-transition pathway. We obtained nearly single-phase ε-Fe 2 O 3 (~87 wt % with ~13 wt % α-phase) with a large coercivity of H c = 20.6 kOe, enabling us to obtain pure ε-Fe 2 O 3 by a simple magnetic separation protocol, and tuned the H c of the ε-Fe 2 O 3 nanoparticles in the range of 4.0–20.6 kOe by controlling the reaction parameters. Furthermore, the structural properties of the resulting ε-Fe 2 O 3 nanoparticles are confirmed by characterizing their chemical and magnetic properties using X-ray absorption spectroscopy and X-ray magnetic circular dichroism measurements.

36 MATERIALS SCIENCE↗

Test Results of the LQXFA/B02 and LQXFA/B03 Cryo-Assemblies for the High Luminosity LHC Upgrade

Here, the US High-Luminosity LHC Accelerator Upgrade Project (AUP) is responsible for delivering cryo-assemblies for the Q1/Q3 quadrupole optical components of the High Luminosity LHC upgrade at CERN. Total of 10 cryo-assemblies containing two Nb3Sn quadrupole magnets per cold mass will be delivered within this program. After the successful test of the first pre-series cryo-assembly in 2023, two more cryo-assemblies were tested at Fermilab's horizontal test facility. Production overview and the test results of the LQXFA/B02 and LQXFA/B03 cryo-assemblies are summarized in this paper. After the first test, to increase the capability of the horizontal test facility, various improvements have been made. These improvements are also described in this paper.

Chlachidze, Guram [Fermi National Accelerator Labo↗

Aging mechanisms of filled cross-linked polyethylene (XLPE) cable insulation material exposed to simultaneous thermal and gamma radiation

Thermal and simultaneous thermal and gamma radiation aging experiments were conducted on an industry grade cross-linked polyethylene (XLPE) cable insulation material, which is a composite material with XLPE as polymer matrix and various additives and fillers. Reverse engineering was conducted to identify and quantify the material composition given that this information was not revealed by the cable manufacture. Samples were then aged at temperatures of 60, 90, and 115 °C, exposed to gamma radiation for total doses of 0 to 324 kGy, and at dose rates of 0 to 540 Gy/h. Aging mechanisms were studied using various materials characterization techniques including pyrolysis gas chromatography mass spectrometry (Py-GCMS), differential scanning calorimetry (DSC), nuclear magnetic resonance spectroscopy (NMR), and gel-fraction tests. Results show that the flame-retardant components were decomposed into smaller molecules when the material was exposed to gamma radiation, while no changes were observed when the samples were aged thermally without gamma radiation. With exposure to gamma radiation, the crystalline phase of the XLPE were damaged by gamma radiation introducing defects in the crystals, resulting in smaller and less perfect crystals. The dominance of chain scission or chain reformation process largely depends on the chain mobility, which is decided by the aging temperature. Chain scission was seen to dominate when the material was exposed to gamma radiation at 60 °C. Chain cross-linking slightly dominated when the material was exposed to gamma radiation at 90 °C and became more dominant with exposure to gamma radiation at 115 °C. No significant change to the XLPE polymer matrix was observed when the samples were exposed to thermal aging without gamma radiation. Finally, antioxidant is more effective in protecting the XLPE polymer matrix under thermal aging, but less effective with sample exposure to gamma radiation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The fluctuation–dissipation measurement instrument at the Linac Coherent Light Source

The development of new modes at x-ray free electron lasers has inspired novel methods for studying fluctuations at different energies and timescales. For closely spaced x-ray pulses that can be varied on ultrafast time scales, we have constructed a pair of advanced instruments to conduct studies targeting quantum materials. We first describe a prototype instrument built to test the proof-of-principle of resonant magnetic scattering using ultrafast pulse pairs. This is followed by a description of a new endstation, the so-called fluctuation–dissipation measurement instrument, which was used to carry out studies with a fast area detector. In addition, we describe various types of diagnostics for single-shot contrast measurements, which can be used to normalize data on a pulse-by-pulse basis and calibrate pulse amplitude ratios, both of which are important for the study of fluctuations in materials. Furthermore, we present some new results using the instrument that demonstrates access to higher momentum resolution.

Assefa, T. A.↗

NDT System for Metal Components in Concrete Structures

The goal of this SBIR program is to develop new NDT technology based on the innovative use of magnetic sensors designed specifically for ECT (Eddy Current Testing) of steel reinforcements in concrete structures. The Phase IIA goal is to expand the R&D accomplished in Phase II, such that the probe system is more capable, and the inspection system is more flexible.

42 ENGINEERING↗

HFTS-1 Natural Joint Data and Engineering Summary

This report provides an analysis of engineering and geologic data collected from the Hydraulic Fracturing Test Site #1 (HTSF-1) project in the southern Midland Basin, Reagan County, Texas. The site is being studied as part of the Science-informed Machine Learning for Accelerating Real-Time Decisions in Subsurface Applications (SMART) Initiative at the National Energy Technology Laboratory (NETL). The data collected is intended to provide a basis of understanding of the site and to construct simulation models. This report provides a summary analysis of the engineering and geologic data collected from the project to provide a basis of understanding of the site and to construct simulation models. The report examines various possible correlations in engineering properties based on natural fracture data from the program, which consisted of 11 horizontal wells, one vertical well, and one slant well. The horizontal wells are in two horizons: 1) Upper and 2) Middle Wolfcamp formations. Program data include: fracture frequency and fracture orientation data from four core runs in a slant well; fracture spacing and orientation from a vertical pilot well; laboratory triaxial testing and mineralogical determinations; and porosity results from magnetic resonance analyses from various wells, together with observations based on the data collection. In addition, available references were reviewed on the site for additional insights. As the focus of the report is on the natural system, hydraulic fracture data from the site were not examined in detail in this report. Data variability is the chief observation in examination of the database. Fracture frequency in the slant well can range from sections with values as high as five fractures per ft to sections up to 100+ ft in length with no natural observed fractures. Fracture spacing across is typically less than 10 ft, but can range up to hundreds of feet. Apparent fracturing shows the trends in two predominate orientations, E-SW and WNW-ESE, but minor variations exist. The rock units vary across the site from siliceous mudstones to calcareous mudstones, showing a general layering with depth. The laboratory properties such as strength and modulus show no apparent trend with depth, but appear to correlate with rock mineralogy with high strength and modulus values where calcium content is high. In addition, an attempt to examine variability and mineralogy on a larger scale was made using a color-coded system based on gamma ray measurements. A staged colored approach was adopted, presuming that lower gamma ray values indicate higher value of calcium content (blue scale) and that higher gamma ray values indicate higher clay mineral content (orange scale). As provided in report appendices, the system correlated well with visual examination of the slant core and the petrofabric analyses of the vertical pilot well. The results showed large variability in mineral content along the horizontal plane across the site. The change in mineral content was also rapid, on a scale less than that of the average hydraulic fracture stage length of about 180 ft.

42 ENGINEERING↗

Improved melt model for power flow

Accelerators that drive z-pinch experiments transport current densities in excess of 1 MA/cm 2 in order to melt or ionize the target and implode it on axis. These high current densities stress the transmission lines upstream from the target, where rapid electrode heating causes plasma formation, melt, and possibly vaporization. These plasmas negatively impact accelerator efficiency by diverting some portion of the current away from the target, referred to as “current loss”. Simulations that are able to reproduce this behavior may be applied to improving the efficiency of existing accelerators and to designing systems operating at ever higher current densities. The relativistic particle-in-cell code CHICAGO ® is the primary code for modeling power flow on Sandia National Laboratories’ Z accelerator. We report here on new algorithms that incorporate vaporization and melt into the standard power-flow simulation framework. Taking a hybrid approach, the CHICAGO® kinetic/multi-fluid treatment has been expanded to include vaporization while the quasi-neutral equation-of-motion has been updated for melt at high current-densities. For vaporization, a new one-dimensional substrate model provides a more accurate calculation of electrode thermal, mass, and magnetic field diffusion as well as a means of emitting absorbed contaminants and vaporized metal ions. A quasi-fluid model has been implemented expressly to mimic the motion of imploding liners for accurate inductance histories. For melt, a multi-ion Hall-MHD option has been implemented and benchmarked against Alegra MHD. This new model is described with sufficient detail to reproduce these algorithms in any hybrid kinetic code. Physics results from the new code are also presented. A CHICAGO ® Hall-MHD simulation of a radial transmission line demonstrates that Hall physics, not included in Alegra, has no significant impact on the diffusion of electrode material. When surface contaminant desorption is mocked in as a hydrogen surface plasma, both the surface and bulk-material plasmas largely compress under the influence of the j × B force. Similar results are seen in Alegra, which also shows magnetic and material diffusion scaling with peak current. Test vaporization simulations using MagLIF and a power-flow experimental geometry show Fe + ions diffuse only a few hundred µm from the electrodes, so present models of Z power flow remain valid.

43 PARTICLE ACCELERATORS↗

Fluid Behavior in Nanoporous Silica

We investigate dynamics of water (H 2 O) and methanol (CH 3 OH and CH 3 OD) inside mesoporous silica materials with pore diameters of 4.0, 2.5, and 1.5 nm using low-field (LF) nuclear magnetic resonance (NMR) relaxometry. Experiments were conducted to test the effects of pore size, pore volume, type of fluid, fluid/solid ratio, and temperature on fluid dynamics. Longitudinal relaxation times (T 1 ) and transverse relaxation times (T 2 ) were obtained for the above systems. We observe an increasing deviation in confined fluid behavior compared to that of bulk fluid with decreasing fluid-to-solid ratio. Our results show that the surface area-to-volume ratio is a critical parameter compared to pore diameter in the relaxation dynamics of confined water. An increase in temperature for the range between 25 and 50°C studied did not influence T 2 times of confined water significantly. However, when the temperature was increased, T 1 times of water confined in both silica-2.5 nm and silica-1.5 nm increased, while those of water in silica-4.0 nm did not change. Reductions in both T 1 and T 2 values as a function of fluid-to-solid ratio were independent of confined fluid species studied here. The parameter T 1 /T 2 indicates that H 2 O interacts more strongly with the pore walls of silica-4.0 nm than CH 3 OH and CH 3 OD.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dilute Paramagnetism and Non-Trivial Topology in Quasicrystal Approximant Fe4Al13

A very fundamental property of both weakly and strongly interacting materials is the nature of their magnetic response. In this work, we detail the growth of crystals of the quasicrystal approximant Fe4Al13 with an Al flux solvent method. We characterize our samples using electrical transport and heat capacity, yielding results consistent with a simple non-magnetic metal. However, magnetization measurements portray an extremely unusual response for a dilute paramagnet and do not exhibit the characteristic Curie behavior expected for a weakly interacting material at high temperature. Electronic structure calculations confirm metallic behavior but also indicate that each isolated band near the Fermi energy hosts non-trivial topologies, including strong, weak, and nodal components, with resultant topological surface states distinguishable from bulk states on the (001) surface. With half-filled flat bands apparent in the calculation, but an absence of long-range magnetic order, the unusual quasi-paramagnetic response suggests the dilute paramagnetic behavior in this quasicrystal approximant is surprising and may serve as a test of the fundamental assumptions that are taken for granted for the magnetic response of weakly interacting systems.

Avers, Keenan E. (ORCID:0000000223441939)↗

Design and Analysis of an Advanced Three-Point Bend Test Approach for Miniature Irradiated Disk Specimens

Candidate tungsten armor materials in a magnetic confinement fusion device must be able to withstand thermal variation that leads to internal stresses caused by the impinging heat load. In addition, the thermomechanical properties of these materials are degraded by irradiation-induced defect accumulation. Fission reactor–based irradiation data are used to predict the fusion neutron damage and property change. This study examines the motivation and design of a custom-designed three-point bend test for neutron-irradiated disk specimens that are 3 mm in diameter to be able to define the flexural strength of advanced tungsten materials, alloys, and composites—and to the extent that embrittlement occurs after neutron irradiation. The theory provided shows a calculation for the flexural deflection and shear deflection due to the small-geometry constraints. A finite element deformation analysis is performed to evaluate the mechanical stress field of disk bend specimens. The stress values above 80% of the maximum stress are concentrated in 2.4 mm of the 3.0-mm length of the centerline across the tungsten disk diameter. A bend test fixture has been designed and fabricated to enable testing of these specimens with precisely engineered tolerance and minimal machine compliance. This fixture will be able to be placed inside a universal testing frame at elevated temperatures for the mechanical property evaluation of future neutron-irradiated disk specimens.

36 MATERIALS SCIENCE↗