Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

An integrated atom array-nanophotonic chip platform with background-free imaging

Arrays of neutral atoms trapped in optical tweezers have emerged as a leading platform for quantum information processing and quantum simulation due to their scalability, reconfigurable connectivity, and high-fidelity operations. Individual atoms are promising candidates for quantum networking due to their capability to emit indistinguishable photons that are entangled with their internal atomic states. Integrating atom arrays with photonic interfaces would enable distributed architectures in which nodes hosting many processing qubits could be efficiently linked together via the distribution of remote entanglement. However, many atom array techniques cease to work in close proximity to photonic interfaces, with atom detection via standard fluorescence imaging presenting a major challenge due to scattering from nearby photonic devices. Here, we demonstrate an architecture that combines atom arrays with up to 64 optical tweezers and a millimeter-scale photonic chip hosting more than 100 nanophotonic cavities. We achieve high-fidelity ( ~ 99.2%), background-free imaging in close proximity to nanofabricated cavities using a multichromatic excitation and detection scheme. The atoms can be imaged while trapped a few hundred nanometers above the dielectric surface, which we verify using Stark shift measurements of the modified trapping potential. Finally, we rearrange atoms into defect-free arrays and load them simultaneously onto the same or multiple devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Na Promotion of Pt/m-ZrO 2 Catalysts for the Steam Reforming of Formaldehyde

The decomposition selectivity of formaldehyde during steam reforming was explored using unpromoted and sodium promoted Pt/m-ZrO 2 catalysts, and the Na content was varied (0.5%Na, 1%Na, 1.8%Na, 2.5%Na, and 5%Na). In situ DRIFTS experiments during temperature programmed reaction in flowing H 2 O revealed that formaldehyde is adsorbed at reduced defect sites on zirconia, where it is converted to formate species through the addition of labile bridging OH species. Formate species achieve a maximum intensity in the range of 125–175 °C, where only slight changes in intensity are observed. Above this temperature, the formate decomposition reactivity strongly depends on the Na loading, with the optimum loadings being 1.8%Na and 2.5%Na. CO 2 temperature programmed desorption results, as well as a greater splitting observed between the formate ν asym (OCO) and ν sym (OCO) bands in infrared spectroscopy, indicate greater basicity is induced by the presence of Na. This strengthens the interaction between the formate -CO 2 functional group and the catalyst surface, weakening the formate C-H bond. A shift in the ν(CH) band of formate to lower wavenumbers was observed by addition of Na, especially at 1.8%Na and higher loadings. This results in enhanced decarboxylation and dehydrogenation of formate, as observed in in situ DRIFTS, temperature-programmed reaction/mass spectrometry experiments of the steam reforming of formaldehyde, and fixed bed reaction tests. For example, 2.5%Na addition of 2.5% increased the CO 2 selectivity from 83.5% to 99.5% and the catalysts achieved higher stable conversion at lower temperature than NiO catalysts reported in the open literature. At 5%Na loading, Pt sites were severely blocked, hindering H-transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adapting Grid Criticality for Data Centers

This presentation explores the evolving definition of “critical load” in the electric grid, emphasizing the growing importance of digital infrastructure—particularly data centers—in grid resilience, restoration, and modernization. As utilities increasingly rely on AI-driven analytics and software-defined control systems, data centers have shifted from passive electricity consumers to essential computational hubs that enable National Critical Functions (NCFs) and support real-time grid operations. The deck examines the scale and impact of digital loads, the need for grid modernization to manage rapid load growth, and the diverse computing paradigms required for AI deployment. It introduces a tiered taxonomy for classifying critical loads, highlights operational dependencies between the grid and digital infrastructure, and discusses policy implications for integrating data centers into emergency planning and restoration protocols. Through case studies and practical frameworks, the presentation provides actionable insights for utilities, regulators, and planners navigating the digital transformation of the power sector.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Precision Loading and Delivery of Molecular Cargo by Size-Controlled Coacervation of Gold Nanoparticles Functionalized with Elastin-like Peptides

Thermoresponsive elastin-like peptides (ELPs) have been extensively investigated in biotechnology and medicine, but little attention has been paid to the process by which coacervation causes ELP-decorated particles to aggregate. Here, using gold nanoparticles (AuNPs) functionalized with a cysteine-terminated 96-repeat of the VPGVG sequence (V96-Cys), we show that the size of the clusters that reversibly form above the ELP transition temperature can be finely controlled in the 250 to 930 nm range by specifying the concentration of free V96-Cys in solution and using AuNPs of different sizes. We further find that the localized surface plasmon resonance peak of the embedded AuNPs progressively red-shifts with cluster size, likely due to an increase in particle–particle contacts. We exploit this fine control over size to homogeneously load precise amounts of the dye Nile Red and the antibiotic Tetracycline into clusters of different hydrodynamic diameters and deliver cargos near-quantitatively by deconstructing the aggregates below the ELP transition temperature. Beyond establishing a key role for free ELPs in the agglomeration of ELP-functionalized particles, our results provide a path for the thermally controlled delivery of precise quantities of molecular cargo. This capability might prove useful in combination photothermal therapies and theranostic applications, and to trigger spatially and temporally uniform responses from biological, electronic, or optical systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlling Deformation in Al/Ti: How Interface Roughness and Orientation Drive Bimetal Mechanics

The microstructural characteristics and morphology of interfaces in metals can be crucial in governing the initiation of plasticity and early deformation mechanisms under extreme conditions. During high-strain-rate deformation, these interfaces significantly affect dislocation nucleation, twinning, and other mechanisms that directly impact material strength and failure. Despite their importance, a substantial knowledge gap remains between the observed macroscopic material behavior and the underlying role of bimetal interfaces in plasticity initiation. Here, to address this gap, large-scale molecular dynamics simulations are performed on Al/Ti bimetal structures to examine the effect of interface characteristics on the onset of plasticity under uniaxial compression. Specifically, this study investigates how interface roughness (flat vs waveform interfaces) modifies the initiation of plastic events in the microstructure. Atomistic simulations indicate that interface roughness (a microscopic behavior) reduces the stress required for dislocation nucleation, thereby reducing the peak stress relative to a flat interface. For the square interface, the step height strongly influences plasticity initiation by setting the separation of locally flat regions. Varying the interface rotation relative to the loading direction (macroscopic behavior) reveals that the peak stress for both flat and waveform interfaces initially decreases and then increases with rotation, accompanied by a shift in dominant mechanisms—from Al twinning (flat) to interface sliding and Ti-dominated phase transformation and twinning at lower angles. The change in the stress-strain slope during initial compression reflects how rotation alters the resolved shear stress and activates different slip systems. Overall, the study provides valuable insights into the role of bimetal interfaces in controlling plasticity initiation and early deformation pathways for Al/Ti under extreme loading conditions.

36 MATERIALS SCIENCE↗

Quadratic Zeeman effect in hydrogen at 2–3 MG magnetic fields

The Zeeman effect is used for measurement of magnetic fields in astrophysical and laboratory plasmas. Magnetic fields in atmospheres of magnetic white dwarf stars are in the range 40 kG–1 GG. The quadratic Zeeman effect results in the additional split and shift of lines for magnetic fields >2 MG. Hydrogen Balmer lines were studied in magnetic fields delivered by a 1 MA pulse power generator. The magnetic field was generated by rod loads 0.8–1 mm in diameter. A droplet of CH oil on the load center was the source of hydrogen. A low ionized oil layer was backlit by blackbody emission from the rod with a temperature of 0.5–0.6 eV. Zeeman splitting of H-alpha and H-beta absorption lines were with a grating spectrometer. A spectral shift of the central component of the triplet indicated the quadratic Zeeman effect in hydrogen lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

Active Site Dynamics in Molybdenum-Based Silica-Supported Olefin Metathesis Catalysts: Site Renewal and Decay Beyond the Chauvin Cycle

Heterogeneous olefin metathesis catalysts exhibit low active site densities and unpredictable kinetics due to dynamic active site formation and decay processes. Here, in this study, we establish a quantitative framework that captures active site generation, renewal, and decay in olefin metathesis over silica-supported molybdenum oxide catalysts, enabling a mechanistic explanation of catalytic behavior and strategies to achieve high, stable activity. Steady-state active site titrations reveal that 2,3-dimethyl-butene isomers (4MEs) cofeeding increases active site density by up to 4.3-fold, directly correlating with enhanced metathesis rates. Spectroscopic studies demonstrate that 4MEs facilitate Mo(VI) reduction to Mo(IV) and interact strongly with surface Si–OH groups, generating labile protons that promote active site formation via a 1,2-proton shift mechanism. Kinetic modeling indicates that ethylene acts as a decay promoter, shifting kinetic control away from the Chauvin cycle and suppressing metathesis activity. Comparative studies on catalysts with varying Mo loading reveal that promotion is most effective for dispersed molybdate species, with a decline at higher Mo loadings. These findings provide a unified mechanistic framework for heterogeneous olefin metathesis, offering new strategies to enhance active site accessibility, mitigate deactivation, and optimize catalyst design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Valuing Residential Energy Efficiency: Analysis for a Prototypical Southeastern Utility [Slides]

The increasing amount of variable renewable energy resources and shifts towards more end-use and vehicle electrification suggests profound changes to power system planning and operation. Specifically, renewable energy is expected to shift net peak demand from late afternoon to early evening and end-use electrification may significantly increase winter peak demand. Residential energy efficiency is likely to align well with these shifts as it tends to produce savings in the early evening (e.g., from lighting measures) and coincident with heating loads (e.g., from envelope and space conditioning measures). Despite the opportunity to decrease system costs and emissions, residential energy efficiency is often limited by static valuation methods and its economic potential is considerably less than its technical potential. Using hourly residential energy efficiency characterizations, utility program cost data, and a capacity expansion model, we estimate the benefits of residential energy efficiency for a prototypical, summer-peaking utility in the Southeastern region. We first establish the cost-effective residential energy efficiency portfolio through “competition” with supply-side resources in a forward-looking capacity expansion model. Importantly, we then evaluate several scenarios intended to drive an increasing amount of cost-effective residential energy efficiency through measure cost reductions, increased customer adoption, policy goals (e.g., carbon price), and delivery of an integrated package of measures. The results quantify total system cost and emissions reductions, fossil-fuel plant retirements, and peak demand reductions. Results suggest the design and prioritization of policies and programs to access the untapped amount of cost-effective residential energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shifting Layer Heights for Closed-Loop Contours in Additive Manufacturing

Traditional slicing for 3D printing involves a planar cross-sectioning process to create layers. These layers are stacked one on top of the next representing a butt-joint, which is typically the weakest direction for loading a 3D printed part. Because the layers are printed sequentially, no material or reinforcement connects from one layer to the next. This clean layer line between layers is easy to break or separate. To fix this, the authors have implemented a new approach to shift the height of every other closed-loop contour toolpath such that a clean layer line no longer exists. This bead shifting approach involves moving every other contour by half a layer height, after the cross-sectioning step, so that a straight line cannot be drawn between layers. To maintain the original object geometry, a half height layer is printed for the first and last layer to create a flat top and bottom surface. This functionality has been implemented and tested as part of ORNL Slicer 2, an open-source toolpathing software package.

Roschli, Alex↗

Creation of Self-Semi-Interpenetrating Network Structures in PIM-1 Membranes for Enhanced Physical Aging Resistance

A series of self-semi-interpenetrating network (ssIPN) thin films based on PIM-1 structure were developed by end-cross-linking telechelic PIM-1 oligomers end-capped with curable carboxylic acid groups to form model networks, which are penetrated by linear high-molecular-weight PIM-1 chains. ssIPN films with systematically varied network content ranging from 10 to 30 wt % were comprehensively examined on their microstructure and gas permeation properties. Fresh PIM-1 ssIPN films exhibited gas separation performances close to those of as-cast linear PIM-1, where the films closely followed the upper bound trade-off line, gaining as much selectivity as they lose gas permeability as the network content increases. This indicates that gas permeability is largely preserved despite cross-linking. Wide-angle X-ray scattering supported this observation, with peaks shifting toward lower d-spacing as oligomer content increased, suggesting tighter chain packing with higher cross-linkable oligomer loading. In physical aging studies over two months, all ssIPN films outperform linear PIM-1 for H 2 /CH 4 and O 2 /N 2 separations. Notably, the PIM-1 ssIPN with 10 wt % network content showed the best physical aging resistance, with negligible permeability loss even after one month. Finally, these findings highlight a promising macromolecular strategy for enhancing the physical aging resistance of microporous polymer membranes for gas separation.

PIM-1↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Interaction of Soil pH and Mineralogy Controls Soil Organic Matter Persistence through Changes in the Composition and Amount of Microbial Necromass

Microbial necromass–mineral associations are key to long-term soil organic matter (SOM) persistence. However, how soil pH and mineralogy interact to regulate SOM stability remains poorly understood. Here, we used artificial soils to test how three clay minerals (bentonite, kaolinite, and goethite), adjusted to four pH levels (5–8), affect microbial activity (respiration), microbial physiology (carbon use efficiency, CUE), microbial-derived residue material (necromass), and the formation and stability of mineral-associated organic matter (MAOM). Artificial soils were inoculated with a rhizosphere-derived microbial community cultured under the same pH conditions and on two representative simulated exudate types (organic acids and carbohydrates) and incubated for 6 weeks. In two complementary experiments, we added necromass from known microbial taxa to the same minerals across pH levels to isolate the role of necromass chemistry and loading. We found that soil pH shaped MAOM chemistry by altering microbial activity and necromass composition. In interaction with mineral type, pH also controlled MAOM thermal stability. Higher necromass loading weakened mineral-organic bonding, reducing MAOM stability, consistent with zonal mineral–organic interaction models. Our results demonstrate that microbial activity, rather than carbon use efficiency, better predicts MAOM formation and that pH-dependent necromass composition and loading govern MAOM persistence. These findings advance mechanistic understanding of SOM stabilization and have implications for predicting soil carbon dynamics under shifting environmental conditions.

carbon use efficiency↗

A Novel Modeling Framework for Computationally Efficient and Accurate Real-Time Ensemble Flood Forecasting With Uncertainty Quantification

A novel modeling framework that simultaneously improves accuracy, predictability, and computational efficiency is presented. It embraces the benefits of three modeling techniques integrated together for the first time: surrogate modeling, parameter inference, and data assimilation. The use of polynomial chaos expansion (PCE) surrogates significantly decreases computational time. Parameter inference allows for model faster convergence, reduced uncertainty, and superior accuracy of simulated results. Ensemble Kalman filters assimilate errors that occur during forecasting. To examine the applicability and effectiveness of the integrated framework, we developed 18 approaches according to how surrogate models are constructed, what type of parameter distributions are used as model inputs, and whether model parameters are updated during the data assimilation procedure. We conclude that (1) PCE must be built over various forcing and flow conditions, and in contrast to previous studies, it does not need to be rebuilt at each time step; (2) model parameter specification that relies on constrained, posterior information of parameters (so-called Selected specification) can significantly improve forecasting performance and reduce uncertainty bounds compared to Random specification using prior information of parameters; and (3) no substantial differences in results exist between single and dual ensemble Kalman filters, but the latter better simulates flood peaks. The use of PCE effectively compensates for the computational load added by the parameter inference and data assimilation (up to ~80 times faster). Therefore, the presented approach contributes to a shift in modeling paradigm arguing that complex, high-fidelity hydrologic and hydraulic models should be increasingly adopted for real-time and ensemble flood forecasting.

54 ENVIRONMENTAL SCIENCES↗

Multi-X-point radiation and its dynamics in up/down asymmetry in plasma detachment regimes in Wendelstein 7-X

In Wendelstein 7-X (W7-X), stable plasma detachment in ECRH hydrogen plasmas is routinely achieved with the standard magnetic configuration, containing five magnetic islands in the scrape-off layer (SOL). Plasma detachment induced by intrinsic carbon impurities is characterized by a high radiation fraction (ƒ rad ) with significantly reduced divertor heat load and particle flux. In this work, we present the radiation dynamics during the detached plasma (DP) phase, such as the shift of radiation zones in radial and poloidal directions towards the X-points as ƒ rad increases (∼0.6–0.9), as well as the penetration of the radiation layer into the confinement region in the deep DP phase with ƒ rad approaching unity. In particular, a structure of multi-X-point radiation (multi-XPR) with an up/down asymmetry in the DP phase is highlighted, which is revealed by bolometer tomography and is further confirmed by video diagnostics. The multi-XPR structure forms helical 3D bands aligned with W7-X field periodicity. Field reversal experiments show that the brightest XPR displaces between the upper and lower SOL regions, suggesting the E× B drift effects. This paper presents the multi-XPR structure observed in the W7-X plasma in detail for the first time. A simplified model considering the influence of the poloidal E× B drift ( V d ) on the impurity flow in the SOL shows that the downstream drift toward the target or target shadow region ( V d < 0) decreases the impurity content, while the upstream drift toward the LCFS ( V d > 0) increases the impurity content. On this basis, the poloidal drift potentially leads to an up/down asymmetry of impurity density in the SOL despite the symmetry magnetic topology. The dynamics of the up/down asymmetry in the multi-XPR structure is also related to the magnitude V d /D (normalized to the impurity diffusivity), with an additional effect owing to the radial inward shift of the emission zone. These results provide new insights into impurity-induced detachment dynamics and provide a basis for improving 3D modeling of impurity transport, which typically does not consider drifts.

E × B drift↗

Reducing Grid Costs while Abating Emissions: Opportunities for Flexible Building Loads

This study evaluates the value of technology-agnostic, shiftable flexible building loads in modeled 2030 and 2040 U.S. grids for four types of customers under three potential aggregated distributed energy resources programs. The value examined includes monetary value from providing grid services (e.g., energy, capacity, flexibility reserve, regulation reserve, contingency reserve) and from reducing greenhouse gas emissions. By comparing more than 845,164,800 simulated shifting opportunities, the study finds that the timing of consumption is critical for profit-driven customers. A program that is activated for 30 critical hours of system operation can result in to $73 per year in revenue for 1 kWh of shiftable load. Emission reduction, on the other hand, is best accumulated through a year-round program: 1 kWh of shiftable load can lead to up to 487.9 kg CO2e carbon reduction per year. The report also provides detailed insights on the trade-off between revenue and emissions, regional variation, short- versus medium- term value, and impacts from various building flexibility parameters, such as shifting window and dissipation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Synchronization as an Indicator of Controllability in a Fleet of Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grid and allow to defer investments in new capacity. However, the growing concern for customer privacy and comfort may impact the performance of load control for residential devices. Water heaters represent a convenient way of reducing peak due to their ability to store thermal energy for future use. In this paper, we developed a methodology to help utilities gain more insight with respect to the impact of load control efforts for shaving peak with no necessary information about the water heaters except the device status (on/off). To this end, we use a fleet of water heaters in a controlled residential neighborhood in Atlanta, GA. Our findings show that convergence in device status can serve as a proxy for peak shifting during hours of the evening peak.

demand response↗