Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Validation of Local Structural Loads Computed by OpenFAST Against Measurements From the Focal Experimental Campaign: Preprint

This work presents the validation of the local structural load modeling capability in OpenFAST for floating substructures based on data from the FOCAL experimental campaign. Previously, OpenFAST could only represent the floating substructure as a rigid body, and though this approach can model the global response of the floater in most cases, it is not able to capture the structural loads within its individual members. Consideration of local substructure loads is important for some floating designs, as the pursuit of cost reduction often results in lighter and more flexible structures. To address this limitation, the HydroDyn (hydrodynamics) and SubDyn (substructure dynamics) modules of OpenFAST have been recently extended to account for the flexibility of floating substructures. To validate this new capability, we compare the results obtained by OpenFAST with data measured during the FOCAL experimental campaign, which analyzed a 1:70 scale performance-matched model of the IEA 15-MW reference turbine atop a modified University of Maine VolturnUS-S semisubmersible in a wave basin under the action of both wind and waves. For the purposes of the present work, the most important feature of the experiment is the presence of load cells at the root of each pontoon, and our objective is to assess how well those loads are reproduced by OpenFAST. To model the distributed hydrodynamic and hydrostatic loads along the floating substructure, we adopt a strip-theory approach based on the Morison equation, and we discuss the impact of different hydrodynamic modeling options (wave stretching, MacCamy-Fuchs correction, and second-order wave kinematics) on both motions and loads. For simplicity, we focus on wave-only conditions, both regular and irregular. The results demonstrate good overall agreement for the loads at the root of the pontoons for the waves analyzed in this work, especially given the assumptions and simplifications inherent to a simple strip-theory model.

floating offshore wind turbine↗

Potential Impacts of Dynamic Electricity Pricing in California: Load Shape and Customer Bill Impacts Under Elastic Customer Response

The increasing penetration of renewable energy in California has intensified grid management challenges, exemplified by the “duck curve” and the resulting need for steep ramping and curtailment of renewables. To address these issues, dynamic electricity tariffs that vary in near-real time are being considered to incentivize customers to shift demand and support the grid. This study extends previous work on the bill impacts of such tariffs in the absence of load response by quantifying the system-level and customer impacts of load response based on customer price elasticity. Customer-level load response modeling was conducted using meter data from 411,000 customers across residential, commercial, and industrial sectors. Customer demand elasticity was estimated using literature-based values, with scenarios ranging from low to high elasticity, including an automation-enhanced scenario. Results indicate that universal adoption of, and response to, dynamic tariffs can significantly reduce peak net load (by 15%) and maximum ramping requirements (by 20%) with moderate elasticity, delivering demand response resources comparable to or exceeding current programs at all elasticity levels. Bill analysis shows that, when responding elastically to dynamic prices, most non-PV customers experience modest savings, while PV customers may see higher effective rates due to lower compensation for exports during low-price periods. Emissions analysis reveals a reduction in per-kWh emissions system-wide, with a total absolute load increase of 2% accompanied by a negligible absolute emissions increase. The study concludes that while dynamic tariffs offer substantial grid benefits, customer bill savings under modeled response behaviors may be too modest to drive widespread adoption without additional incentives or enabling technologies. Future research should model flexible loads and advanced control technologies with greater fidelity to better represent the potential opportunities of dynamic tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying the Impact of Metal Population Distribution in MFI-Supported Mo Catalysts for Methane Dehydroaromatization

Precise evaluation of intrinsic kinetic behavior in Mo/MFI catalysts for methane dehydroaromatization (MDA) is confounded by variations in Mo dispersion and speciation, which are influenced by metal loading and zeolite acidity. This work advances the utility of H 2 -temperature programmed reduction (H 2 -TPR) for characterizing Mo/MFI catalysts by enabling quantitative comparison of MoO x populations distinguished by reduction behavior and linked to initial catalytic performance. A comprehensive H 2 reduction pathway is established through systematic H 2 - TPR studies varying catalyst composition (1–10 wt % Mo, Si/Al = 15, 40, ∞), supplemented by UV-Raman spectroscopy, X-ray powder diffraction, N 2 physisorption, NH 3 -TPD, and advanced spectroscopic analysis (in situ XAS with principal component analysis/multivariate curve resolution—alternating least squares). Two low-temperature H 2 -TPR regions capture distinct Mo populations undergoing initial Mo(VI)→Mo(IV) reduction: a lower-temperature population (Mo-RI) associated primarily with highly dispersed, anchored MoO x species expected to predominantly reside within MFI channels, and a higher-temperature population (Mo-RII) corresponding to a broader set of MoO x species that becomes increasingly bulk-like/extrazeolitic at higher Mo loading. Quantification of these populations provides practical, kinetically relevant descriptors for comparing initial MDA rates across catalysts with varying Mo loading, Si/Al ratio, and MoO x heterogeneity. Application of lower-temperature Mo-RI estimates to kinetic measurements reveals a minimum threshold of ∼0.12 × 10 –3 mol Mo-RI/g cat , above which initial forward benzene rates normalized to this population converge despite differences in metal loading and zeolite Brønsted acidity. This threshold coincides with a transition toward a common C 2 -mediated benzene-forming regime, as indicated by approach-to-equilibrium analysis of methane-to-ethane, ethane-to-ethylene, and ethylene-to-benzene reaction steps. Above this threshold, normalized initial benzene rates are nearly invariant with increasing Mo-RII/Mo-RI population ratio, indicating that excess Mo-RII populations, including bulk-like/extrazeolitic MoO x domains present at higher loading, do not measurably suppress benzene formation associated with anchored and mostly channel-confined Mo population under the initial-rate conditions examined.

Mo/MFI↗

Reducing the computational burden of a microgrid energy management system

As renewable technology advances and decreases in cost, microgrids are becoming an appealing means of distributed generation both for isolated communities and integrated with existing electrical grid systems. Due to their small size, however, microgrids may have financial limitations which preclude them from using commercial software to optimize control of their assets. Open-source optimization solvers are a viable alternative, but increase computation time. This work expands on a rolling horizon optimization framework for economic dispatch within an existing residential microgrid located in Hoover, Alabama. The microgrid has an open-source solver requirement and a need for quick solution time on a rolling horizon as opposed to a day-ahead commitment. We present a method of reducing integer variables by relaxation which completes two goals: reduction in computation time for real-time operations, and reduction in daily operational cost for the microgrid. Seasonal data for load and photovoltaic (PV) power was also collected from the microgrid to facilitate simulation testing. Computation time was successfully reduced using multiple variations of the relaxation method, while obtaining solution quality with operational cost similar to or better than the original model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Constraining the release of Sn to the ambient melting point following shock loading using time-resolved x-ray diffraction

The formation of liquid following release from a shocked state governs the transition from spall to cavitation and the formation of ejecta in metals. In order to build physics-based models of these processes, it is necessary to critically evaluate the relative importance of kinetics and entropy generation during the release along with the accuracy of multiphase equations of state. Tin (Sn) has served as a testbed for a variety of experiments examining strength and ejecta due to its accessible melt boundary and solid–solid phase transitions. This work presents experiments examining the phase evolution of high purity Sn following the shock and release to ambient stress near the melting point. Sn is found to release to states between its ambient solidus and liquidus from approximately 19 to 33 GPa under uniaxial loading, with the two-phase region being characterized by a reduction in the intensity of the (220), (211) β -Sn doublet. Jetting experiments performed at 27–28 GPa exhibit comparable diffraction patterns with what is observed following the uniaxial release. The solid fractions of β-Sn in the ambient mixed phase region are found to decrease linearly with increasing shock stress as increasing liquid Sn is formed. Here, the results provide much needed information for interpreting measurements of dynamic strength at a high strain rate and experiments examining cavitation and shallow bubble collapse in Sn.

, spall↗

A Novel Miniaturized MIMO Microstrip Patch Antenna Array with EBG- and Slot-Loading

A compact four-element multiple-input multiple-output (MIMO) antenna array based on the miniaturized mi-crostrip patch is presented. The reduction in array form factor is realized by partially populating the ground plane with elec-tromagnetic band gap (EBG) cells constructed from cross slots, in combination with reactively loading each patch with a slot. The resultant 2 × 2 array system demonstrates excellent inter-element isolation and can be easily fabricated using traditional milling and printing techniques, as it exploits a 2D layout that can be conveniently implemented on two sides of a single-layer substrate, without the need for any via structures. The operation of the array near the 2.5 GHz band is verified with full-wave simulations. The size of the new design is approximately 42% of that employing conventional patch elements.

Liao, DaHan↗

Efficient Data Management in Neutron Scattering Data Reduction Workflows at ORNL

Oak Ridge National Laboratory (ORNL) experimental neutron science facilities produce 1.2 TB a day of raw event-based data that is stored using the standard metadata-rich NeXus schema built on top of the HDF5 file format. Performance of several data reduction workflows is largely determined by the amount of time spent on the loading and processing algorithms in Mantid, an open-source data analysis framework used across several neutron sciences facilities around the world. The present work introduces new data management algorithms to address identified input output (I/O) bottlenecks on Mantid. First, we introduce an in-memory binary-tree metadata index that resemble NeXus data access patterns to provide a scalable search and extraction mechanism. Second, data encapsulation in Mantid algorithms is optimally redesigned to reduce the total compute and memory runtime footprint associated with metadata I/O reconstruction tasks. Results from this work show speed ups in wall-clock time on ORNL data reduction workflows, ranging from 11% to 30% depending on the complexity of the targeted instrument-specific data. Nevertheless, we highlight the need for more research to address reduction challenges as experimental data volumes increase.

Godoy, William↗

Numerical characterization of quasi-steady thermal load for thin crystal at cryogenic temperature with nondiffusive heat transfer

With dramatically improved brightness and repetition rate, the thermal load for crystal optics in x-ray free-electron laser applications has also significantly increased. To mitigate the thermal load, one effective method is cryogenic cooling. However, the emerging nondiffusive heat transfer phenomenon at cryogenic temperature may cause design failure if overlooked. To evaluate the optical performance of thin crystal optics under thermal load at cryogenic temperature, an integrated numerical tool is presented and applied to characterize the thermal load on thin crystals with nondiffusive phenomena accounted. Significant thermally induced distortion of the rocking curve is observed from numerical simulation, leading to potential seed power reduction in hard x-ray self-seeding application. Cryogenic cooling is confirmed necessary by simulation to handle the thermal load at high repetition rate operation.

42 ENGINEERING↗

Managing Power Systems-Induced Wildfire Risks Using Optimal Scheduled Shutoffs

The increasing demands for electricity and the increase in extreme weather conditions are putting unprecedented pressure on our electric grids. Often, this pressure leads to electrical component failures, which might ignite wildfires. This work develops a novel model to balance the reliability of power network operations and the risk of wildfire ignition by opti- mizing the operational schedule of power transmission networks considering time-varying risk measures that include exogenous and operational factors. Energy storage systems are considered to deliver power during peak wildfire hours and enable temporal load shifting. The problem is formulated as a mixed-integer linear program that maximizes a weighted sum of the served power demand and the reduction in grid-induced wildfire risk. The results demonstrate the ability of the model to significantly reduce wildfire risk without considerable load shedding.

power systems operations↗

Managing Power Systems-Induced Wildfire Risks Using Optimal Scheduled Shutoffs: Preprint

The growing demands for electricity and the increase in extreme weather conditions are putting unprecedented pressure on our electrical grids. Oftentimes, this pressure leads to electrical components failures which might ignite wildfires. This work develops a novel model to balance the reliability of power networks operations and risks of wildfires ignition by optimizing the operational schedule of power transmission networks considering time-varying risk measures that consider exogenous and operational factors. Energy storage systems are considered to deliver power during peak wildfire hours and enable temporal load shifting. The problem is formulated as a mixed-integer linear program that maximizes a weighted sum of the served power demand and the reduction in grid-induced wildfires risk. The results demonstrate the ability of the model to reduce wildfires risks significantly without considerable load shedding.

energy scheduling↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential-Controlled Deposition of Multilayer CO 2 Reduction Catalyst Films onto Silicon Photoelectrodes Demonstrates Thickness-Dependent Catalytic Rates

Covalently attaching molecular catalysts to semiconductor surfaces yields promising hybrid photoelectrode architectures for reducing CO 2 to higher-value carbon products. Polymeric molecular catalyst films have higher loading densities than their monolayer counterparts, promising greater rates of solar fuel production. Using photoassisted diazonium electrografting, multilayered films of a Re(apbpy)(CO) 3 Cl CO 2 -reduction catalyst were attached to low-doped p-type Si (pSi). Parallel characterization of the newly formed films with ellipsometry, XPS, and ICP-MS revealed that catalyst loading increased with increasingly negative applied grafting potentials (Vgraft), providing us an experimental test bed to study the effects of film thickness on photocatalytic performance. Controlled-potential electrolysis experiments showed enhanced CO evolution rates on all photoelectrodes with increasingly negative applied potentials (V app ), with thicker films exhibiting the greatest rates of enhancement. Competitive proton reduction reactions at the Si surface were not strongly linked to V app but dependent on film thickness, with thicker films showing increased CO-to-H 2 production ratios.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Effects of the method of active site characterization for determining structure-sensitivity in Ag-catalyzed ethylene epoxidation

We report catalysts have been prepared on a low surface area α-Al 2 O 3 support used commercially for previous generation olefin epoxidation catalysts. Prescreening of the low surface area alumina (0.73 m 2 /g) indicated the absence of acid catalyzed isomerization of EO at an evaluation temperature of 210 °C. A 0.1 wt% Ag base material synthesized by incipient wetness impregnation of AgNO 3 was used as a base material for electroless deposition (ED) of additional Ag to increase particle sizes by controlled reduction of Ag + directly onto the preexisting Ag surface to form weight loadings between 0.3 and 5.0 wt% metal. A 12 wt% Ag/α-Al 2 O 3 using Ag 2 C 2 O 4 as the Ag precursor was also prepared to compare performance of the ED samples with a catalyst more typical of industrial formulations. Characterization by SEM, STEM, and hydrogen titration of oxygen precovered Ag characterized before and after catalytic evaluation indicated that microscopy is required to accurately represent distributions of Ag particle sizes, but H 2 titration of O-precovered Ag gives the best representation of active sites since it directly counts the number of Ag surface sites. Larger particles >100 nm are resistant to both Ag sintering and carbon foulant; TOF values were relatively insensitive to particle size with only a 2.2 × difference between the best and worst performing samples. Selectivity, which is not a function of TOF, shows the most significant structure sensitivity effect where particle sizes follow the trend 67 nm ≈ 92 nm (58% EO) < 157 nm (67% EO) < 211–542 nm (73% EO). The lower EO selectivities were also correlated with increased fouling for the smaller Ag sizes, suggesting that more strongly bound EO precursor(s) leads to combustion and CO 2 /H 2 O formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trace level of atomic copper in N-doped graphene quantum dots switching the selectivity from C 1 to C 2 products in CO electroreduction

To unravel the relationship between trace Cu on the metal-free catalysts toward CO/CO 2 reduction reaction (CO/CO 2 RR), we investigated the effect of trace Cu loading in N-doped graphene quantum dots (NGQDs) on CO/CO 2 RR. A general trend is that increasing the Cu loading in NGQDs switches the selectivity from C 1 (CH 4 ) to C 2 products in CORR. When 2.5 μg/cm 2 Cu with the atomic size is loaded on NGQDs, the selectivity shifts from 62% Faradaic efficiency (FE) of CH 4 to 52% FE of C 2 products in CORR. Further increasing the atomic Cu loading to 3.8 μg/cm 2 promotes the FE of C 2 products to 78%. CO 2 RR requires one order of magnitude higher Cu loading than CORR to switch the selectivity from C 1 to C 2 products due to the low partial pressure of CO. Finally, this study clarifies the distinct impact of trace (ppm level) Cu on the activity/selectivity between CORR and CO 2 RR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hierarchical Transactive Control of Flexible Building Loads Under Distribution LMP

With grid modernization efforts, future distribution networks, which consist of various distributed generators and flexible loads, will be more flexible and active. All new network components of distributed energy resources (DERs) drive and enable the transition towards a market-based distribution net-work that seeks the optimal allocation of all DERs. To address challenges associated with DERs, one promising solution is to utilize demand-side flexibility of building loads facilitated by demand response (DR) programs and provide ancillary grid services through distribution-level markets. Under this new paradigm, this paper proposes an efficient DR management strategy incorporating emerging price signals of distribution markets, i.e., distribution locational marginal price (DLMP), based on a hierarchical transactive control approach. The proposed approach establishes a two-layer decision-making framework; the upper layer formulates a bilevel model to obtain an optimal demand response (ODR) under DLMP, and the lower layer employs model-free control to dispatch the (aggregated) ODR to individual end users. Numerical case studies using a modified IEEE 33 test network are performed to verify the effectiveness of the proposed approach; load shifting and peak shaving for the distribution system operator and payments’ reduction for end users while maintaining their comfort.

Park, Byungkwon↗

DC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer

This article proposes a fast predictive control method and a small DC-link inductor to minimize the DC-link current in current-source converter (CSC)-based solid-state transformer. The DC-link current minimization can significantly reduce power loss and improve efficiency. The challenge of this problem is on improving both steady-state and dynamic performance. PI control methods and large DC-link inductors are conventionally used in the CSC but have limited dynamic performance. A model predictive control (MPC) method is proposed to achieve switching-cycle-level settling time, and the DC-link inductor is sized for 40% ripple to enable fast current change. Importantly, this article also proposes to minimize the DC-link current by varying the current even within a line cycle under single-phase load to improve the steady-state performance, in contrast with the reduction to a constant value in the literature. The proposed MPC features a constant switching frequency without weighting factors. The MPC does not have a high computational burden and is implemented in a regular digital controller for a prototype of soft-switching solid-state transformer (S4T) with reduced conduction loss. The effectiveness of the proposed method has been experimentally verified on the SiC S4T prototype during steady-state and dynamics under different multiport power flow conditions up to 2 kV peak. Here, the DC-link current in the experiments is close to the minimum current with a short zero-vector duration, which further verifies the performance of the proposed method.

14 SOLAR ENERGY↗