Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗

Development of an Electrochemical Hydrogen Contaminant Detector

Hydrogen refueling stations (HRSs) that dispense hydrogen to fuel cell vehicles need to ensure the quality of hydrogen to avoid contamination of the vehicle’s expensive fuel cell stacks. Currently, stations verify their fuel quality only periodically to ensure that they meet the strict fuel quality standards specified by either International Organization for Standards (ISO) or Society for Automotive Engineers (SAE). The development of hydrogen contaminant detectors (HCDs) that can provide low cost continuous monitoring at the HRS can be an invaluable asset in protecting fuel cell vehicles from any fuel contamination in-between infrequent expensive analysis of hydrogen fuel quality. An HCD capable of detecting < 200 ppb of CO in hydrogen is presented in this paper. The HCD is based on an electrochemical hydrogen pumping cell whose ultra-low loaded working electrode is poisoned by the contaminant, thus reducing its hydrogen oxidation reaction rate. The hydrogen pumping cell consists of a Nafion® membrane, a sputtered Pt working electrode, a Pt/Ru counter/pseudo-reference electrode and an internal water wicking system that provides humidification to the membrane and electrodes. When this HCD is operated in a pulsed voltammetry mode, it can provide stable CO response for thousands of hours in a HRS.

47 OTHER INSTRUMENTATION↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhanced Control, Optimization, and Integration of Distributed Energy Applications (ECO-IDEA)

With support from the U.S. Department of Energy Solar Energy Technologies Office, the National Renewable Energy Laboratory (NREL) partnered with Xcel Energy, Schneider Electric, Varentec, and Electric Power Research Institute (EPRI) to meet the goals of the Enabling Extreme Real-Time Grid Integration of Solar Energy (ENERGISE) program. This project developed and validated an innovative data-enhanced hierarchical control architecture that enables the efficient, reliable, resilient, and secure operation of future distribution systems with a high penetration of distributed energy resources like solar energy. The architecture enables a hybrid control approach where a centralized control layer is complemented by distributed control algorithms for solar inverters and autonomous control of grid edge devices. It is fully interoperable and includes all the cybersecurity aspects necessary for reliable and secure system operation. The hybrid approach can seamlessly integrate multiple voltage-regulation technologies, both at central and grid-edge levels, which enables reliable and efficient system operation in the face of unpredictable conditions. The overarching goal of the Eco-Idea project is to develop, validate, and deploy a unique and innovative Data-Enhanced Hierarchical Control (DEHC) architecture that comprehensively addresses the formidable challenges associated with proliferation of high penetration of distributed PV such as reverse power flows, transients from variability of PV systems, feeder load balancing, and voltage stability. These issues are exposing the weaknesses of existing grid operations and controls - including, but not limited to, lack of grid situational awareness, heuristic and slow-acting control actions, latency of control for emergency situations, and points of failure in communications. The proposed architecture will comprehensively resolve the deficiencies of current operational settings - where monitoring and control solutions proposed across industry and academia may not be interoperable and may not coexist in the same system - and will enable an efficient, reliable, resilient, and secure operation of future distribution systems with penetration of solar energy well beyond current limits. The DEHC architecture was developed and validated rigorously through hardware-in-loop simulations in the laboratory environment and deployed on the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical Studies of the On-Line Reactivity Monitoring Techniques in Subcritical Systems: Revisit of the Area-Ratio Method, the Neutron Source-Modulation Method, and the Flux-to-Current Ratio Method

In the subcritical systems, the subcriticality level must be monitored continuously to ensure the safe operation of the systems. Techniques such as the neutron source-modulation method and the flux-to-current ratio method have been proposed for on-line reactivity measurements of the subcritical systems. However, the accuracy of these methods is unknown in the actual applications. In this report, the fundamental concepts of these techniques are visited, with numerical simulation techniques developed to validate these on-line reactivity monitoring methodologies. Specifically, the Monte Carlo numerical simulation results show that the neutron source-modulation method is not accurate in determining the reactivity of the subcritical systems. The flux-to-current ratio method can provide on-line reactivity measurements, and its spatial effects have been studied and well understood through the numerical simulations of the fuel loading of the neutron source facility of Ukraine. In addition, a modified version of the area-ratio method is proposed for the on-line measurements of the absolute reactivity of the subcritical systems. Monte Carlo numerical simulations showed that this method can provide the absolute reactivity of the subcritical systems within ~5% error, if the neutron detectors are placed close to the fuel assembly interface with the reflector zone or in the reflector zones away from the neutron source.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Flow-Enhanced Sensors for Actinide Quantification in MSRs

This report serves as the deliverable for Milestone M2RS-22AN0401062 that is part of Work Package RS-22AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone is to assess the capabilities of flow-enhanced electrochemical sensors (FEES) to quantify actinides in molten salt reactors. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits in order to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. To support this work, Argonne constructed a molten salt flow system to serve as a testbed for the development of safeguards and process monitoring-relevant sensors in challenging molten salt flow conditions. Through extensive flow testing using UCl3-bearing salts, Argonne has been able to show that the FEES are able to make good measurements of salt composition. Concentration measurements with a mean absolute error of 0.09 wt% have been achieved for representative fuel salt mixtures across a range of UCl3 loadings. Repeatability was also good, with the relative standard deviation from repeated measurements being less than 1.0%. These sensors have also been shown to be able to measure the flow rate of the salt within the flow system’s transfer line. Although the accuracy of the sensors has been good, the sensors have thus far not been able to achieve performance good enough to satisfy the nuclear material accountancy requirements in 10 CFR 74. To do so, accuracy levels of 0.1% must be achieved; the FEES when operated in Argonne’s flow system have so far only been able to achieve relative errors of approximately 5.0%. Much of the error that has been observed at this stage is due to challenges in maintaining a stable salt composition in the molten salt flow system, and it is not believed that there are any inherent flaws in the sensor design. Nonetheless, the high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will likely be needed to push the measurement accuracy to the needed level.

Moore, Colin E.↗

Complete Performance Comparison Between the Optimized Image Construction Algorithm (U-MBIR) and the Existing Reconstruction Algorithm for Detecting Defects and Damage in Concrete

Reinforced concrete (RC) is a composite material subjected to mechanical, thermal, and chemical loads throughout its service life. Because of these external stressors and the susceptibility of RC structural members to shrinkage and microcracking, the material degrades throughout its life cycle. This deterioration can lead to a decrease in member capacity and, ultimately, poses a threat to the structural integrity. Thus, it is crucial that the damage caused by aging and degradation be monitored and assessed at regular intervals throughout the material’s service life. Since coring of the material is typically not feasible for in-service structural systems, non-destructive evaluation (NDE) methodologies are used to assess remaining structural capacity. NDE methods enable surface and subsurface examination without damaging or degrading the medium. Moreover, RC is a critical component of nuclear power plants; thus, its safety and reliability must be thoroughly examined throughout the life cycle of the structural system. Ultrasonic measurements have been an industry standard for both surface and subsurface inspections. To this end, Oak Ridge National Laboratory (ORNL) has researched and developed advanced image reconstruction algorithms to capture internal damage. The results and discussion presented herein summarize the current state of the ultrasonic model–based iterative reconstruction (U-MBIR) algorithm developed at ORNL. More specifically, this report presents a comparison between reconstruction images produced via a widely employed ultrasonic NDE technique—the synthetic aperture focusing technique (SAFT)—and the ORNL-developed U-MBIR algorithm. These NDE methodologies are demonstrated using ultrasonic data collected from four concrete specimens. Overall, the U-MBIR algorithm eliminates artifacts and noise that are typically present within the SAFT reconstructions, and it shows defects and anomalies more clearly than the SAFT images. In conclusion, this algorithm is suitable for identifying concrete defects, although more improvements and optimization could be done to better define internal defects.

36 MATERIALS SCIENCE↗

Design, Construction, and Field Validation of a Blown-In Fiberglass Wall System in a Cold, Wet, and Windy Climate

In the Native Village of Tununak, located on Nelson Island in Southwest Alaska,buildings are exposed to wind-driven rain and snow throughout the year. The Cold Climate Housing Research Center (CCHRC) and Knauf Insulation partnered with the community in 2018 to design a residence for a public safety officer. Construction began in fall 2021 and is scheduled to conclude in summer 2022. The house will use integrated trusses with floor, attic, and wall cavities filled with blown-in fiberglass insulation. Hygrothermal models of the building envelope system demonstrate that the high ambient moisture load will wet the outer edges of the insulation annually regardless of the extent and integrity of exterior weather sealing measures; blown-in fiberglass is expected to be more resilient to this wetting than blown-in cellulose. To verify this, researchers will embed temperature, relative humidity, and moisture sensors in the two windward walls of the house to monitor the ability of the blown-in fiberglass insulation to dry out after wetting events that may have occurred during the transport of the insulation to the building site, storage of the insulation on site, construction process, or after installation in the wall. Sensors will remain in place for two years,documenting the wall's performance over time and verifying the design's potential for use in buildings located in climates where the chance for moisture damage is high. Here, we describe the wall system , design criteria, and the results from the hygrothermal modeling. We share details on the monitoring system's components and the planned management and analysis of data. Finally, we explain how the experiences and data from this project will inform future builds in similar locations.

building design↗

Generalizability analysis of tool condition monitoring ensemble machine learning models

Tool condition monitoring (TCM) is an essential research area for the optimization and automation of metal machining processes, and could help manufacturers reduce costs, production time, machine downtime, energy use, and part scrappage. However, TCM systems developed in prior studies have struggled to reach the high level of generalizability which is necessary for industrial applications. This study addresses TCM system generalizability to new machining conditions, how variations in machining and environmental conditions may be used to improve model generalizability, and ensemble machine learning techniques for TCM. Further, milling tool life experiments were conducted using various machining conditions, and the processes' sound, spindle power, and axial load signals were collected. Different machine learning models were evaluated for the prediction of tool wear levels, including four individual models and five ensemble models. Changes in cutting speed were found to display a large effect on model performance, while the chip load showed some effect, and the feed rate had little effect. A simulated noise data augmentation technique for model improvement is applied within TCM for the first time, and resulted in increased model generalizability and reduced overfitting. Across several performance metrics the extremely randomized trees ensemble machine learning model generally performed the best for this application, achieving a leave-one-group-out cross validation accuracy score of 92.4 %, a 10-fold cross validation score of 98.9 %, and an averaged accuracy across 11 generalizability tests of 87.3 %.

42 ENGINEERING↗

Effects of fiber dosage, loading orientation and stress on frequency response of enhanced Carbon Nano-Fiber Aggregates

Nanomaterial additives have been broadly used in cement and concrete-based sensors to measure the stress and strain in the structure. Most of the studies focused on measuring the resistivity of sensors with Direct Current (DC) or relatively low-frequency. Here in this work, the impedance responses of enhanced Carbon Nano-Fiber Aggregates (CNFAs) at different frequencies are rigorously studied and utilized as a tool for real-time structural health monitoring (SHM). The CNFA impedance measurements at different measurement frequencies provide an extra dimension (frequency dimension) to allow the characterization of different phenomena and multimodal measurements simultaneously. First, a comprehensive physical model is established to understand the frequency responses of the CNFA impedance. Second, COMSOL Multiphysics is used to simulate the frequency responses of the CNFA impedance, which provides more insights into the electric field and current density distribution. The impedance of CNFAs decreased with the increased dosage of carbon nanofibers (CNFs). Third, experimental studies are reported in detail. The electrical impedance variation (EZV) of the CNFA in parallel orientation is 151% higher than that of perpendicular orientation at the frequency of 2612 Hz and uniaxial compression stress of 4.65 MPa. The strain-EZV curve obtained from the response spectrum is linear for frequencies ranging from 98 Hz to 463.9 kHz. The strain-EZV curve for 5625 Hz has a linear fit with the gauge factor of 147.78. At 1000 Hz, the CNFA exhibited a repeatable behavior up to 9.35 MPa and detection limit up to the stress of 18.62 MPa.

36 MATERIALS SCIENCE↗

High spatial resolution temperature profile measurements of solid-oxide fuel cells

Temperature gradients resulting from local electrochemical reactions, current distribution and geometry of gas flow channels in solid oxide fuel cells (SOFCs) create thermal stresses, localized thermophysical property gradients and uneven property evolution, contributing to SOFC degradation. This paper presents a new method to perform temperature measurements (up to 800°C) at high spatial resolutions to monitor the operation of SOFCs. Using femtosecond laser irradiation, distributed fiber sensors were hardened for high temperature environment applications. Distributed fiber sensors were embedded in interconnected plates using an additive manufacturing method to perform temperature measurements with 4-mm spatial resolution during the operation of a planar fuel cell. The measurement revealed the impact of various H 2 fuel concentrations and current loads have on temperature profiles of the SOFC tested. Temperature variation on the anode side was found to be less than 5°C, and 3°C on the cathode side. The measurements were compared to results from a multiphysics fuel cell performance model simulating similar conditions. These simulations predicted similar temperature gradients, indicating the experimental data obtained is reasonable. The model also predicts that the effect of the embedded sensor has on the local temperature will be minimal and that the gradient of temperature in the gas channels will be captured despite the separation between the sensor and the gas flow. Finally, the high spatial resolution data harnessed by these distributed fiber sensors provides experimental support for model-based design and optimization to improve the operational efficiency and longevity of solid oxide fuel cells and fuel cell assemblies.

25 ENERGY STORAGE↗

Experimental Tests of Lateral Bedload Transport Induced by a Yawed Submerged Vane Array in Open-Channel Flows

This work proposes the use of an array of yawed porous vanes to control the lateral bedload transport by locally steering bedform migration and maximize the amount of sediments redirected toward a potential sediment extraction system or bypass channel. A laboratory experiment was conducted in a quasifield-scale channel with an array of permeable vanes installed on one side, in live-bed conditions under bedload dominant regime, i.e., negligible suspended load. A baseline experiment without vanes was also performed for comparison. The evolution of migrating bedforms of different scales was tracked in space and time using a high-resolution, state-of-the-art laser scanning device. The bedload transport rate in the streamwise direction was first calculated using bedforms’ geometry and migration velocity, and then spatially distributed over the entire monitored area using a new Eulerian-averaged grid-mapping method. This allowed us to introduce a new methodology to estimate the lateral bedload transport using control volume theory and applying mass conservation. Quantitative assessments of lateral bedload transport along the channel yield consistent results, suggesting that the vanes effectively move sediments laterally as intended. Under the investigated setup, the maximum lateral sediment transport rate ranges from 9% to 18% of the whole domain-averaged streamwise transport rate. The developed methodology also allowed to identify the location where sediment capture could be maximized for the given vane spatial distribution.

42 ENGINEERING↗

A simplified approach for creep damage and remaining life calculation for materials surveillance in advanced reactors

High temperature reactor materials will experience a combination of mechanical degradation caused by creep and fatigue and environmental degradation caused by neutron irradiation and, in some cases, exposure to corrosive coolants. A materials surveillance program is one option for ensuring the safe, reliable operation of key reactor components under these conditions. Such a program would monitor the degradation in key material properties over time, using this data to predict how changes in the material properties affect components performance. This could then be used to make plant operational decisions and support eventual plant license extensions. Past work de-scribes such a material surveillance program based on passively actuated mechanical test articles that impose creep-fatigue type loading on test materials driven only by changes in temperature, for example those experienced by components under standard operating cycles. This report focuses on two aspects of the proposed material surveillance program: how to design the test articles to mimic the mechanical response of the corresponding component and how to use ex-situ test data to deter-mine the amount of damaged experienced by the test article (and hence the corresponding compo-nent) in service. Specifically, this report derives and validated simplified methods for both tasks, replacing earlier, more complicated approaches based on simulating the test article response and finding the best specimen design or current damage via complex numerical optimization. The sim-plified methods for each task developed here can be implemented in spreadsheet software and are simple enough for practical use in future operating plants. This report derives the methods (one for sizing and two options for damage inference), verifies the simplified approaches versus more so-phisticated methods, and compares the results of applying the simplified methods to previous re-sults using the complex numerical optimization approach. The report also provides a worked sam-pled problem applying the simplified techniques to a realistic high temperature reactor component.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Acoustoelastic characterization of plates using zero group velocity Lamb modes

Acoustoelasticity, a characteristic of material anharmonicity, gives rise to a link between wave propagation velocity and the stress state in materials. Ultrasonic techniques to monitor this coupling, particularly with high sensitivity and in a noncontact manner, can have widespread application both in the quantification of applied and residual stress and in the characterization of nonlinear material behavior through measurement of higher order elastic constants. Here, we use a laser ultrasonic technique to excite and detect zero group velocity (ZGV) Lamb wave resonances in aluminum plates under uniaxial loading. A laser line source is used to excite these resonances at different orientations with respect to the applied load, and the signals are detected using an interferometer. The effects of stress and source orientation on ZGV resonance frequencies are validated using the theory of acoustoelastic Lamb wave propagation. In addition, a model-based inversion technique is used to extract Murnaghan's third-order elastic constants from measurements of the stress dependence of the first two ZGV modes generated parallel and perpendicular to the applied load. Laser generation and detection of ZGV resonances is shown to be an effective and powerful approach for the noncontact and nondestructive acoustoelastic characterization of elastic waveguides.

36 MATERIALS SCIENCE↗

The JSNS 2 data acquisition system

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate γ-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with flash analog-to-digital converters. Here, we present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Best Basis Inventory Data to Direct Strategies for Real-Time Monitoring of Hanford High Level Waste

The proposed Direct Feed High Level Waste (DFHLW) approach for processing high-level tank waste at Hanford is intended to reduce processing time by bypassing the Pretreatment Facility and transferring waste directly from the tank farm to the WTP HLW vitrification facility. This processing strategy could reduce or eliminate the washing and leaching steps that would have occurred in the Pretreatment facility. Operation of the vitrification facility is subject to chemical and radiological limits protecting safety (e.g. Waste Acceptance Criteria, or WACs) and process quality (e.g. Process Control Limits, or PCLs). Without washing and leaching, there is a greater risk of exceeding the WACs and PCLs. Hanford process engineers have devised blending strategies based on known chemical and radiological composition, volumes, and solids loadings of individual layers within each waste tank. These blending campaigns succeed in predicting a processing strategy that does not exceed the WACs and PCLs. However, the calculations do not ascribe uncertainties to the tank analysis data, quantities of material taken from the tanks to make the blend, or potential for mixing of layers within tanks. In order to confirm that a process strategy is working, it would be advantageous to have inline or at-line analytical instrumentation installed in the processing facilities that deliver measurement results in real time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗