Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OpenSAMPL: An Open Source Library for Timing and Synchronization Measurements and Analytics

Today's power grid operators are implementing timing and synchronization solutions that provide resilience to Global Navigation Satellite System (GNSS) vulnerabilities. These vendor-specific solutions often come with additional software applications that are designed to monitor that vendor's synchronization performance data. However, resilient timing architectures often resulting in multi-vendor solutions, including approaches that blend terrestrial clocks with space-based subscription services. In such an environment, collecting, analyzing, and visualizing data from a variety of sources within a single platform was heretofore not possible. To address this need, the US Department of Energy's Center for Alternative Synchronization and Timing (CAST) developed OpenSAMPL, the Open Synchronized Analytics and Monitoring Platform, an open-source Python framework for processing, loading, and observing clock measurement data from distributed devices. OpenSAMPL enables the ingestion of diverse clock-probe sources into a scalable time-series database and applies robust analytics. OpenSAMPL currently supports two vendor data pipelines, and will be extended to more in the near future, enabling seamless monitoring of a variety of timing and synchronization devices in a common environment.

Grant, Josh [ORNL] (ORCID:0000000163475060)↗

Frequency and load ratio effects on critical strain energy release rate Gc thresholds of graphite/epoxy composites

Graphite/epoxy composite laminates of T300/BP907 and AS6/HST-7 were axial-tension fatigue tested. Tests were conducted at 5 and 10 Hz, and at loading ratios of R = 0.1 and R = 0.5. Edge delamination was monitored as a function of number of fatigue cycles by monitoring stiffness reduction during fatigue testing. Delamination was confirmed and documented using dye-enhanced X-ray and optical photography. Critical strain energy release rates were then calculated. The composites delaminated readily, with loading ratio having a significant influence. Frequency effects were negligible.

Adams, Donald F.↗

Summary of Activities for Health Monitoring of Composite Overwrapped Pressure Vessels

This three-year project (FY12-14) will design and demonstrate the ability of new Magnetic Stress Gages for the measurement of stresses on the inner diameter of a Composite Overwrapped Pressure Vessel overwrap. The sensors are being tested at White Sands Testing Facility (WSTF) where the results will be correlated with a known nondestructive technique acoustic emission. The gages will be produced utilizing Meandering Winding Magnetometer (MWM) and/or MWM array eddy current technology. The ultimate goal is to utilize this technology for the health monitoring of Composite Overwrapped Pressure Vessels for all future flight programs. The first full-scale pressurization test was performed at WSTF in June 2012. The goals of this test were to determine adaptations of the magnetic stress gauge instrumentation that would be necessary to allow multiple sensors to monitor the vessel's condition simultaneously and to determine how the sensor response changes with sensor selection and orientation. The second full scale pressurization test was performed at WSTF in August 2012. The goals of this test were to monitor the vessel's condition with multiple sensors simultaneously, to determine the viability of the multiplexing units (MUX) for the application, and to determine if the sensor responses in different orientations are repeatable. For both sets of tests the vessel was pressured up to 6,000 psi to simulate maximum operating pressure. Acoustic events were observed during the first pressurization cycle. This suggested that the extended storage period prior to use of this bottle led to a relaxation of the residual stresses imparted during auto-frettage. The pressurization tests successfully demonstrated the use of multiplexers with multiple MWM arrays to monitor a vessel. It was discovered that depending upon the sensor orientation, the frequencies, and the sense element, the MWM arrays can provide a variety of complementary information about the composite overwrapped pressure vessel load conditions. For example, low frequency measurements can be used to monitor the overwrap thickness and changes associated with pressure level. High frequency data is dominated by the properties of the overwrap, including the fiber orientations and lay-up of the layers.

Russell, Rick↗

Tapered Roller Bearing Damage Detection Using Decision Fusion Analysis

A diagnostic tool was developed for detecting fatigue damage of tapered roller bearings. Tapered roller bearings are used in helicopter transmissions and have potential for use in high bypass advanced gas turbine aircraft engines. A diagnostic tool was developed and evaluated experimentally by collecting oil debris data from failure progression tests conducted using health monitoring hardware. Failure progression tests were performed with tapered roller bearings under simulated engine load conditions. Tests were performed on one healthy bearing and three pre-damaged bearings. During each test, data from an on-line, in-line, inductance type oil debris sensor and three accelerometers were monitored and recorded for the occurrence of bearing failure. The bearing was removed and inspected periodically for damage progression throughout testing. Using data fusion techniques, two different monitoring technologies, oil debris analysis and vibration, were integrated into a health monitoring system for detecting bearing surface fatigue pitting damage. The data fusion diagnostic tool was evaluated during bearing failure progression tests under simulated engine load conditions. This integrated system showed improved detection of fatigue damage and health assessment of the tapered roller bearings as compared to using individual health monitoring technologies.

Dempsey, Paula J.↗

Neutron Dosimetry for the SAM-2 Irradiation in ATR

PNNL project 79550 provides for the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00269673 and Statement of Work No. 19704, Rev. 0, PNNL Analysis of NSUF Flux Capsules. This report is for the SAM-2 irradiation which was conducted in position B8 of the ATR. Other experiments included in the statement of work for this project will be reported separately. The neutron fluence monitors were prepared by PNNL and sent to INL for loading into the SAM-2 assembly prior to irradiation. The SAM-2 experiment has 8 capsules labelled A through H designed for different exposures in successive irradiation cycles. This report is for the first three capsules, A, B and C, co-irradiated for 1 cycle. The remaining capsules and fluence monitors will be removed and analyzed after additional irradiation. Following irradiation, the fluence monitors from capsules A, B, and C were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma or x-ray analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of heat treatment and build orientation on the evolution of $ϵ$ and $α'$ martensite and strength during compressive loading of additively manufactured 304L stainless steel

In this paper, the effect of heat-treatment and build orientation on martensitic phase transformation in additively manufactured (AM) 304L stainless steel is studied and compared with conventionally produced wrought material. The relationships between observed martensitic transformations and material microstructures and their effects on mechanical strength are established through experimental observations. In situ high-energy X-ray powder diffraction measurements were performed to monitor the evolution of $ϵ$ and $α'$ martensite during compressive loading of stainless steel. Electron backscatter diffraction (EBSD) was used to provide insight on initial grain morphology, crystallographic misorientation within grains, and crystallographic texture. Heat treatment alters the microstructure of AM samples creating different initial conditions. This difference in starting microstructure resulted in variability in martensitic transformation during compressive deformation. The rate of martensitic transformation decreased for AM samples treated with temperatures up to 1100°C, after which the AM microstructures recrystallized, resulting in increased rate of martensitic transformation for those samples treated at higher temperatures. It was also observed that aligning the axis of compression with the AM build direction resulted in a lower rate of strain-induced martensite formation as opposed to aligning the compression axis perpendicular to it. More favorable distribution of crystal orientations in the latter loading orientation promoted martensitic transformation. These and additional experimental observations from EBSD in terms of kernel average misorientation, mean grain orientation spread, and mean crystallite size reveal strong microstructural effects on strength of additively manufactured metallic materials.

304L stainless steel↗

A potential means of using acoustic emission for crack detection under cyclic-load conditions

A preliminary investigation was conducted to assess the feasibility of monitoring acoustic emission signals from fatigue cracks during cyclic bend tests. Plate specimens of 6A1-4V titanium, 2219-T87 aluminum, and 18-Ni maraging steel were tested with and without crack starter notches. It was found that significant acoustic emission signals could be detected in the frequency range from 100 kHz to 400 kHz. Cracks emanating from starter notches were monitored by the ultrasonic pulse-echo technique and periodically measured by micro-optical examination. Methods used to reduce the effects of extraneous noises (i.e., machine noises, fretting) are described. A frequency spectrum analyzer was used to characterize the emissions and to evaluate methods used to acquire the signals (i.e., transducer location, bandwidth selection). The investigation indicated that it was possible to extract meaningful acoustic emission signals in a cyclic bend machine environment.

Vary, A.↗

A potential means of using acoustic emission for crack detection under cyclic-load conditions.

A preliminary investigation was conducted to assess the feasibility of monitoring acoustic emission signals from fatigue cracks during cyclic bend tests. Plate specimens of 6Al-4V titanium, 2219-T87 aluminum, and 18-Ni maraging steel were tested with and without crack starter notches. It was found that significant acoustic emission signals could be detected in the frequency range from 100 to 400 kHz. Cracks emanating from starter notches were monitored by the ultrasonic pulse-echo technique and periodically measured by micro-optical examination. The investigation indicated that it was possible to extract meaningful acoustic emission signals in a cyclic bend machine environment.

Vary, A.↗

Surface Deformation and Gravity Changes from Surface and Internal Loads

Air and space borne remote sensing have made it possible to monitor the mass and energy transport at various scales within the cryosphere-hydrosphere-atmosphere system. The recent surface mass balance (the rate of net gain of snow and ice at a geographic point) map for the Antarctic ice sheet is constructed by interpolating sparse in situ observations (about 1,800 points) with empirically calibrated satellite data of passive back emission of microwaves. The digital elevation model obtained from satellite radar altimetry is used to improve the delineation of the ice flow drainage basins. As important as these results are, the uncertainty remains up to about 2 mm/yr of eustatic sea level change with the net imbalance. In other words, we are still unable to determine even the sign of the contribution of the Antarctic ice sheet to contemporary sea level change. The problem is more likely with the discharge rather than accumulation.

Hager, Bradford H.↗

Response of thick, notched laminates subjected to tension-compression cyclic loads

The fatigue response of a (0/24/90/-45)s4 T300-5208 graphite-epoxy laminate with a drilled centerhole subjected to fully reversed tension-compression (R=-1, T-C) constant amplitude loading was investigated. Damage evaluation techniques such as stiffness monitoring, penetrant-enchanced X-ray radiography, C-scan, laminate deeply and residual strength were used to establish the mechanisms of damage development as well as the relations between this damage and the stiffness, strength and life of the laminate. Damage initiated at the hole as matrix cracking parallel to the fibers in all plies. Matrix cracks had a significant effect on delamination initiation and growth. Delaminations initiated near the surface in the densely cracked region at the hole and grew along major matrix cracks. Compressive properties degraded more rapidly than tensile properties. At the stress levels used, residual tensile strength increased early in the fatigue life and remained approximately constant to near the end of life, when failure was precipitated by excessive laminate instability during the compressive portion of the loading.

Bakis, C. E.↗

Response of thick, notched laminates subjected to tension-compression cyclic loads

The fatigue response of a (0/24/90/-45)s4 T300-5208 graphite-epoxy laminate with a drilled centerhole subjected to fully reversed tension-compression (R=-1, T-C) constant amplitude loading was investigated. Damage evaluation techniques such as stiffness monitoring, penetrant-enhanced X-ray radiography, C-scan, laminate deply and residual strength were used to establish the mechanisms of damage development as well as the relations between this damage and the stiffness, strength and life of the laminate. Damage initiated at the hole as matrix cracking parallel to the fibers in all plies. Matrix cracks had a significant effect on delamination initiation and growth. Delaminations initiated near the surface in the densely cracked region at the hole and grew along major matrix cracks. Compressive properties degraded more rapidly than tensile properties. At the stress levels used, residual tensile strength increased early in the fatigue life and remained approximately constant to near the end of life, when failure was precipitated by excessive laminate instability during the compressive portion of the loading.

Bakis, C. E.↗

Lightweight ZERODUR: Validation of Mirror Performance and Mirror Modeling Predictions

Upcoming spaceborne missions, both moderate and large in scale, require extreme dimensional stability while relying both upon established lightweight mirror materials, and also upon accurate modeling methods to predict performance under varying boundary conditions. We describe tests, recently performed at NASA's XRCF chambers and laboratories in Huntsville Alabama, during which a 1.2 m diameter, f/1.2988% lightweighted SCHOTT lightweighted ZERODUR(TradeMark) mirror was tested for thermal stability under static loads in steps down to 230K. Test results are compared to model predictions, based upon recently published data on ZERODUR(TradeMark). In addition to monitoring the mirror surface for thermal perturbations in XRCF Thermal Vacuum tests, static load gravity deformations have been measured and compared to model predictions. Also the Modal Response(dynamic disturbance) was measured and compared to model. We will discuss the fabrication approach and optomechanical design of the ZERODUR(TradeMark) mirror substrate by SCHOTT, its optical preparation for test by Arizona Optical Systems (AOS). Summarize the outcome of NASA's XRCF tests and model validations

technology↗

Adaptive Load Control of Flexible Aircraft Wings Using Fiber Optic Sensing

Over the past century aircraft wing design has transformed from the morphing wing used on the Wright Flyer to rigid wings with little to no shape-tailoring abilities. Modern day wings are designed to fly at a single trim condition and optimized to have a maximum aerodynamic efficiency at only this condition. Shape morphing wings on the other hand have the potential to undergo geometric changes allowing them to adapt to their mission profiles. Several flight demonstrations have been conducted over the decades using morphing-wing technologies. Active wing-twist control was demonstrated on the X-53 Active Aeroelastic Wing (AAW) research project by utilizing multiple leading- and trailing-edge control surfaces. Passive morphing technology has been demonstrated on the Rockwell RPRV-870 Highly Maneuverable Aircraft Technology (HiMAT) aircraft. In the current study, the wings of a small unmanned aerial system (sUAS) were modified to have segmented control surfaces (SCS). The modifications include segmenting the original wing control surfaces (one flap and one aileron per wing) into 44 individual sections, each section having its own independent servo control motor. The wings were also instrumented with a network of over 1800 fiber-optic strain sensors (on four sensing fibers distributed over the top and bottom surfaces of the wing) monitoring the strain response of the wing to aerodynamic loading. The SCS positions were manipulated in real time to modify the spanwise lift distribution of the wings on the sUAS. The change in the structural response of the wings caused by load redistribution was quantified by measuring the bending strains on the upper and lower wing surfaces using an on-board compact fiber-optic strain sensing (cFOSS) system. A feedback controller was developed to control the SCS positions using strain-based shape estimations from the Displacement Transfer Function (DTF). Post-processing of the strain data allowed for the transverse displacement distributions and load distributions to be compared for the conventional and segmented control surface cases using displacements and loads algorithms developed by Richards and Ko at AFRC (refs. 5-10). While the current study focused on the shifting of the spanwise aerodynamic loads as quantified by displacements, future applications for loads or displacement control might include active gust alleviation and flutter suppression.

Pena, Francisco↗

X ray attenuation measurements for high-temperature materials characterization and in-situ monitoring of damage accumulation

The scope of this dissertation is to develop and apply x ray attenuation measurement systems that are capable of: (1) characterizing density variations in high-temperature materials, e.g., monolithic ceramics, ceramic and intermetallic matrix composites, and (2) noninvasively monitoring damage accumulation and failure sequences in ceramic matrix composites under room temperature tensile testing. This dissertation results in the development of: (1) a point scan digital radiography system, and (2) an in-situ x ray material testing system. Radiographic evaluation before, during, and after loading shows the effect of preexisting volume flaws on the fracture behavior of composites. Results show that x ray film radiography can monitor damage accumulation during tensile loading. Matrix cracking, fiber matrix debonding, fiber bridging, and fiber pullout are imaged throughout the tensile loading of the specimens. Further in-situ radiography is found to be a practical technique for estimating interfacial shear strength between the silicon carbide fibers and the reaction bonded silicon nitride matrix. It is concluded that pretest, in-situ, and post test x ray imaging can provide for greater understanding of ceramic matrix composite mechanical behavior.

Baaklini, George Y.↗

Command Interface ASIC - Analog Interface ASIC Chip Set

A command interface application-specific integrated circuit (ASIC) and an analog interface ASIC have been developed as a chip set for remote actuation and monitoring of a collection of switches, which can be used to control generic loads, pyrotechnic devices, and valves in a high-radiation environment. The command interface ASIC (CIA) can be used alone or in combination with the analog interface ASIC (AIA). Designed primarily for incorporation into spacecraft control systems, they are also suitable for use in high-radiation terrestrial environments (e.g., in nuclear power plants and facilities that process radioactive materials). The primary role of the CIA within a spacecraft or other power system is to provide a reconfigurable means of regulating the power bus, actuating all valves, firing all pyrotechnic devices, and controlling the switching of power to all switchable loads. The CIA is a mixed-signal (analog and digital) ASIC that includes an embedded microcontroller with supporting fault-tolerant switch control and monitoring circuitry that is capable of connecting to a redundant set of interintegrated circuit (I(sup 2)C) buses. Commands and telemetry requests are communicated to the CIA. Adherence to the I(sup 2)C bus standard helps to reduce development costs by facilitating the use of previously developed, commercially available components. The AIA is a mixed-signal ASIC that includes the analog circuitry needed to connect the CIA to a custom higher powered version of the I(sup 2)C bus. The higher-powered version is designed to enable operation with bus cables longer than those contemplated in the I(sup 2)C standard. If there are multiple higher-power I(sup 2)C-like buses, then there must an AIA between the CIA and each such bus. The AIA includes two identical interface blocks: one for the side-A I(sup 2)C clock and data buses and the other for the side B buses. All the AIAs on each side are powered from a common power converter module (PCM). Sides A and B of the I(sup 2)C buses are electrically isolated from each other (see figure). They are also isolated from the CIA by use of transformer coupling of signals between the AIA blocks and the CIA.

Ruiz, Baldes↗

A low-cost centralized HVAC control system solution for energy savings, load shedding, and improved maintenance

University campuses rely on centralized controls for managing and optimizing complex HVAC systems in larger buildings. However, most campuses also have many smaller buildings with packaged HVAC systems controlled by a stand-alone thermostat. Even when these distributed and often overlooked systems have modern programmable thermostats, they cannot be centrally monitored or controlled, and they are typically not programmed adequately. This paper describes the implementation of a low-cost centralized control solution for these systems serving smaller campus buildings, mostly under 5,000 sf and representative of light commercial spaces. Thanks to advances in technology spurred by residential and commercial IoT developments, simple networked thermostat solutions exist that can easily replace original thermostats, and, connect these systems to a web-based portal for monitoring and control. We show that, with small customizations, these platforms can be integrated into facility management workflows. Beyond the energy savings potential from improved scheduling and closer management of these systems, there are significant advantages for maintenance crews since these systems can now be monitored on smart phones or tablets. A grid-responsive load-shedding program has also been implemented for additional cost savings. The networked thermostats can also be connected to additional systems such as economizer controls for improved ventilation management and energy savings. With data from these systems integrated centrally, it can also be used for improved analytics and fault detection. A toolkit has been developed to share the program with other campuses, whether for energy savings, improved management of ventilation, or a more proactive maintenance approach.

Fauchier-Magnan, Nicolas↗

Stress-Dependent Matrix Cracking in 2D Woven SiC-Fiber Reinforced Melt-Infiltrated SiC Matrix Composites

The matrix cracking of a variety of SiC/SiC composites has been characterized for a wide range of constituent variation. These composites were fabricated by the 2-dimensional lay-up of 0/90 five-harness satin fabric consisting of Sylramic fiber tows that were then chemical vapor infiltrated (CVI) with BN, CVI with SiC, slurry infiltrated with SiC particles followed by molten infiltration of Si. The composites varied in number of plies, the number of tows per length, thickness, and the size of the tows. This resulted in composites with a fiber volume fraction in the loading direction that ranged from 0.12 to 0.20. Matrix cracking was monitored with modal acoustic emission in order to estimate the stress-dependent distribution of matrix cracks. It was found that the general matrix crack properties of this system could be fairly well characterized by assuming that no matrix cracks originated in the load-bearing fiber, interphase, chemical vapor infiltrated Sic tow-minicomposites, i.e., all matrix cracks originate in the 90 degree tow-minicomposites or the large unreinforced Sic-Si matrix regions. Also, it was determined that the larger tow size composites had a much narrower stress range for matrix cracking compared to the standard tow size composites.

Morscher, Gregory N.↗