Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Short-term electricity load forecasting: Application-driven evaluation of machine learning models across spatial and temporal scales

As we transition towards a decarbonized economy, the integration of variable renewable energy resources and new demands (e.g., electric vehicles, heat pumps) into the electricity grid places unprecedented pressure on grid operators to effectively anticipate and manage peak load. In this context, machine learning algorithms are proving to be indispensable for accurate short-term load forecasting, a crucial task to address these challenges. This study benchmarks 6 machine learning algorithms, including three neural networks and three tree-based algorithms, across various levels of spatial aggregation and time horizons (1, 4, 8, 24, and 48 h). The central contribution of this work is the comparison and analysis of load forecasting models not only based on statistical metrics, but also based on a novel error metric, which evaluates the cost implications of forecast errors for power system stakeholders. Results show that tree-based models outperform neural networks, based on statistical metrics, and yield less skewed error distributions for most spatial scales. However, through the lens of the novel error metric, neural networks are the more competitive choice, especially for forecast horizons that exceed 8 h. The study concludes with actionable recommendations to grid operators and highlights the need for the development of error metrics that link forecasting accuracy to operational costs. To promote transparency and open science, the datasets and Python code are open-sourced via a supplementary repository.

Houben, Nikolaus↗

Thermal Analysis of a Superconducting Undulator Cryostat for the APS Upgrade

The Advanced Photon Source Upgrade includes four 4.8-m-long superconducting undulator (SCU) cryostats, each containing two planar undulator NbTi magnets up to 1.9 m long. The cooling is provided by six cryocoolers arranged in three thermal circuits. The magnets are indirectly cooled with LHe penetrating through channels in the magnet cores. This 4 K circuit, which also includes a LHe tank, is cooled by five 4 K cryocooler 2nd stages. A beam vacuum, which is thermally isolated from the magnets, is cooled by one 10 K cryocooler 2nd stage. A thermal shield and warm parts of current leads are cooled by the 1st stages of all six cryocoolers. This paper presents an ANSYS-based thermal analysis of the new SCU cryostat including all thermal circuits. The benchmarked thermal conductance between the cryocooler cold heads and the LHe tank are used in the calculations as well as the measured cryocooler load lines. The model predicts temperatures in the system, total 4 K heat loads, and excess cooling power for various operational modes of the undulator.

Shiroyanagi, Y.↗

Voltage Restoration in Microgrids using Temporal Logic Specifications

This paper proposes an energy storage controller synthesis method for voltage restoration in microgrids with respect to temporal logic specifications (TLSs). TLSs is introduced in this paper as a formalism to control the voltage variation of a critical bus against an operational bounds over time. The power system with synchronous generator (SG) connected to a critical load bus is modeled as a set of differential-algebraic equations and a simplified analytical model is derived to describe the voltage variation of this critical bus. The control objective is to schedule an optimal control input signal from a supportive energy storage system (ESS) connected to the critical bus, such that the voltage variation of the latter satisfies the TLSs, such as a finite-time restoration. The proposed control is verified on a lumped distribution system model. With this control diagram, supportive controllers can be designed to make voltage behaviors comply with grid codes and avoid unnecessary relay actions.

Taousser, Fatima Zohra↗

Limits on the Range and Rate of Change in Power Take-Off Load in Ocean Wave Energy Conversion: A Study Using Model Predictive Control

Previous work comparing power take-off (PTO) architectures for ocean wave-powered reverse osmosis suggests that variable displacement in the wave energy converter (WEC)-driven pump does not offer a significant performance advantage. A limitation of that study is that the WEC was subject to a constant load within a given sea state (“Coulomb damping”) and did not account for controlled, moment-to-moment variation of the PTO load enabled by a variable displacement pump. This study explores the potential performance advantage of a variable PTO load over Coulomb damping. Model predictive control is used to provide optimal load control with constraints on the PTO load. The constraints include minimum and maximum loads and a limit on the rate of load adjustment. Parameter studies on these constraints enable conclusions about PTO design requirements in addition to providing an estimated performance advantage over Coulomb damping. Numerical simulation of the Oyster 1 WEC is carried out with performance weighted by historical sea state data from Humboldt Bay, CA. The results show a performance advantage of up to 20% higher yearly-average power absorption over Coulomb damping. Additionally, the parameter studies suggest that the PTO load should be adjustable down to at least 25% of the maximum load and should be adjustable between the minimum and maximum loads within a few seconds.

16 TIDAL AND WAVE POWER↗

Short-Term Forecasting of Thermostatic and Residential Loads Using Long Short-Term Memory Recurrent Neural Networks

Internet of Things (IoT) devices in smart grids enable intelligent energy management for grid managers and personalized energy services for consumers. Investigating a smart grid with IoT devices requires a simulation framework with IoT devices modeling. However, there lack comprehensive study on the modeling of IoT devices in smart grids. This paper investigates the IoT device modeling of a thermostatic load and implements the recurrent neural networks model for short-term load forecasting in this IoT-based thermostatic load. The recurrent neural network structure is leveraged to build a load forecasting model on temporal correlation. The temporal recurrent neural network layers including long short-term memory cells are employed to learn the data from both the simulation platform and New South Wales residential datasets. The simulation results are provided for demonstration.

electric load forecasting↗

AlphaBuilding - Synthetic Buildings Operation Dataset

This is a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years' historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants' diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

AlphaBuilding↗

Integrated Transmission-Distribution Multi-Period Switching for Wildfire Risk Mitigation: Improving Speed and Scalability with Distributed Optimization: Preprint

With increasingly severe wildfire conditions driven by climate change, utilities must manage the risk of wildfire ignitions from electric power lines. During "public safety power shutoff'" events, utilities de-energize power lines to reduce wildfire ignition risk, which may result in load shedding. Distributed energy resources provide flexibility that can help support the system to reduce load shedding when lines are de-energized. We investigate a coordinated transmission-distribution optimization problem that balances wildfire risk mitigation and load shedding. We model distribution systems that include battery energy storage systems which may support loads when transmission lines are de-energized. This multi-period integrated transmission-distribution optimal switching problem jointly optimizes line switching decisions, the generators' setpoints, load shedding, and the batteries' states of charge, resulting in significant computational challenges. To improve scalability, we decompose the problem over both space and time and apply a distributed optimization algorithm. Using a large-scale synthetic California test case with realistic distribution models and real wildfire risk data, we show that distributed optimization can solve large-scale multi-period switching problems that are otherwise intractable for centralized solvers. We also discuss challenges and future directions for improving the distributed algorithm's convergence performance as the number of time periods increases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A synthetic building operation dataset

Abstract This paper presents a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years’ historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants’ diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multi-Phase Modeling Framework Suitable for Dynamic Applications

Under dynamic loading conditions and the associated extreme conditions many metals will undergo phase transformations. The change in crystal structure associated with solid–solid phase transformations can significantly alter the subsequent mechanical response of the material. For the interpretation of experiments involving dynamic loading it is beneficial to have a modeling framework that captures key features of the material response while remaining relatively simple. We introduce a candidate framework and apply it to the metal tin to highlight a range of behaviors that are captured by the model. We also discuss potential extensions to capture additional behaviors that could be important for certain materials and loading scenarios. The model is useful for analysis of results from dynamic experiments and offers a point of departure for more complex model formulations.

36 MATERIALS SCIENCE↗

Net Load Forecasting With Disaggregated Behind-the-Meter PV Generation

As worldwide use of residential photovoltaic (PV) systems grows, system operators and utilities will need to transition from forecasting pure demand to forecasting net load with behind-the-meter (BTM) PV generation. However, PV generation can be difficult to predict and the measurements of PV generation from BTM residential systems are often invisible behind a measurement of the net load, making net load forecasting challenging. This paper proposes a novel two-stage framework for net load forecasting in areas with limited observability and high BTM PV generation. First, the profiles of observable customers are used to disaggregate the net load measurements into the pure load and PV generation. Then, separate models are used to forecast the PV generation and pure load individually, and the results are combined for a net load forecast. Further, this paper also proposes a compensator for correcting the error of the net load forecast, using historical forecast errors of the PV generation, pure load, and net load. The proposed framework is tested through two case studies for areas with high BTM PV penetration and less than 10% observable customers. The two-stage forecasting model is compared to two benchmark methods - a time series forecasting model, and a model that forecasts the net load directly using historical net load measurements. Results show that the proposed disaggregation-forecasting framework reduces the error of the net load forecast compared to both benchmark models. In addition, when the net load forecast error is periodic, the compensator can correct the error to improve the forecast accuracy.

14 SOLAR ENERGY↗

Modeling and control of cascaded bridgeless multilevel rectifier under unbalanced load conditions

The goal of this project is to model and control a novel unidirectional cascaded multilevel bridgeless rectifier as an active front end in medium and high voltage applications. This topology has many advantages over a conventional cascaded H-bridge rectifier, such as lower implementation cost, higher reliability, and greater flexibility with similar power quality. The complete design process of the proposed converter is developed step by step in order to meet all the desired objectives. The steady-state mathematical model is used to develop a method for the voltage balancing of dc cells. Power factor analysis is discussed to mathematically derive requirements for the number of partially controlled and fully controlled H-bridges in the proposed H-bridge converter. Power loss, efficiency, and cost comparison studies between the traditional cascaded H-Bridge converter and the proposed bridgeless converter demonstrate the advantages. After exploring various well-established control methods, a novel control strategy is proposed to achieve dc voltage balancing, fast and robust grid synchronization, power factor correction, and elimination of zero crossing current distortion under both balanced and unbalanced load conditions. The converter can also be used for reactive power compensation in a grid tied power system if a sufficient number of fully controlled H-bridge modules are included. Processor-In-the-Loop (PIL) simulation has been the utilized to validate the performance of discrete control structure. Simulation and experimental results validate the models and control method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of lithium as a tritium storage medium for betavoltaics

Lithium foils were demonstrated to absorb surrogate protium for tritium-powered betavoltaics. 20μm thick lithium foils were hole-punched from a ribbon of electrodeposited lithium on copper foil. The lithium foils were loaded with hydrogen in a custom Sievert apparatus where the pressure drop showed full hydriding at a hydrogen pressure of 2 bar and at all loading temperatures above the lithium melting point at 190, 200, 225, 250, and 300. Lithium hydride formation was confirmed with Raman spectroscopy after hydrogen loading. The kinetics of experimental hydride formation was compared to the diffusion-limited Mintz–Bloch model. While the Mintz–Bloch model showed good fit with the experimental loadings, the model overpredicted the loading kinetics starting at 250 °C and at higher temperatures. In conclusion, The overprediction was either caused by lithium hydride outgassing due to some reduction with some residual lithium hydroxide created from brief air exposure when sealing the lithium in the reactor or a transition from diffusion-limited hydride growth to surface or metal–hydride interface-limited hydride growth.

25 ENERGY STORAGE↗

Understanding early HIV-1 rebound dynamics following antiretroviral therapy interruption: The importance of effector cell expansion

Most people living with HIV-1 experience rapid viral rebound once antiretroviral therapy is interrupted; however, a small fraction remain in viral remission for an extended duration. Understanding the factors that determine whether viral rebound is likely after treatment interruption can enable the development of optimal treatment regimens and therapeutic interventions to potentially achieve a functional cure for HIV-1. We built upon the theoretical framework proposed by Conway and Perelson to construct dynamic models of virus-immune interactions to study factors that influence viral rebound dynamics. We evaluated these models using viral load data from 24 individuals following antiretroviral therapy interruption. The best-performing model accurately captures the heterogeneity of viral dynamics and highlights the importance of the effector cell expansion rate. Our results show that post-treatment controllers and non-controllers can be distinguished based on the effector cell expansion rate in our models. Furthermore, these results demonstrate the potential of using dynamic models incorporating an effector cell response to understand early viral rebound dynamics post-antiretroviral therapy interruption.

60 APPLIED LIFE SCIENCES↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Thermal Overloading Risk Mitigation With a Semi-Analytical Probabilistic Model on Branch Current

A semi-analytical formulation is presented in this paper for the probability computation of branch current in multiphase systems. The developed formula is derived based on the linear power flow model in rectangular coordinates. The system uncertainty injections can be renewable energy resources or loads and are modeled using a Gaussian mixture model (GMM). The developed formula can be used to compute the line current violation probability as well as integrate into optimal power flow problem as chance-constraint relaxation. Here, the proposed formula is first compared with the Matlab embedded numerical integration function to show its performance. Besides, the semi-analytical formula is validated and compared with the Monte Carlo simulation method using the IEEE 123-bus system, EPRI Ckt5, and Ckt7 systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗