Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictive and Cooperative Voltage Control with Probabilistic Load and Solar Generation Forecasting

This paper proposes predictive cooperative voltage control method in a power system with high penetration of photovoltaic (PV) units. Cooperative distributed control of the reactive power output of PV inverters is coordinated with operation of voltage regulators (VRs) to maintain system voltages within an appropriate bandwidth. Probabilistic forecasting of the solar power generation and the loads is applied to estimate voltage changes which, in turn, are used to set the VR tap positions for preventing large voltage fluctuations with the lowest risk considering the voltage distribution estimation. The fine tuning of voltage adjustment is achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on the modified IEEE 123-node test feeder with high PV penetration using real insolation data and with constant loads replaced by several different load profiles. Simulation results demonstrate the effectiveness of the coordinated approach for voltage control with cooperative PV and predictive VR controls taking into account probabilistic load and solar power forecasts.

Cooperative Control↗

Loads Response That is Due to Wake Steering on a Pair of Utility-Scale Wind Turbines

The goal of this report is to present the resulting turbine loads of a full-scale wind turbine wake steering field campaign. In this experiment, wake steering controls were applied to an upwind turbine (T2) and the downwind turbine (T3) was instrumented to measure mechanical loads. The test subjects (T2 & T3) were GE 1.5SLE CWE turbines located on a wind farm with a prevailing wind direction coming from the northwest. The data collection strategy involved toggling the wake steering controls of T2 between on and off. This resulted in two databases (baseline and wake steered) with similar turbulence intensities. Valid data was extracted and processed. The analysis involved scaling data to engineering units, applying coordinate transformations where applicable, calculating 10-minutes statistics, and calculating damage equivalent loads (DELs) to assess fatigue. Figures are shown as statistics and DELs binned by wind speed with supplemental scatter plots provided in the appendices. Results between the baseline and wake steered databases were compared. Overall, the binned statistics showed minimal differences in loading between the two cases. However, the DELs of the wake steered case were observed to be consistently smaller than the baseline for most of the turbine components. A potential for future work was recognized based on the findings of this report. Some areas of further study include an analysis for more granular loads sensitivity to different yaw offset angles and rotor wake overlap, an in-depth comparison of loads between the upwind and downwind turbines, and further fatigue analysis to quantify differences observed in this experiment.

17 WIND ENERGY↗

Performing k eff Validation of As-Loaded Criticality Safety Calculations Using UNF-ST&DARDS: Sensitivity Calculations

The general method for performing validation of as loaded criticality safety calculations using UNF ST&DARDS is presented in a paper by Clarity, which includes a description of the UNF-ST&DARDS system. Proof-of-principle analyses were performed in the summer of 2019 for MPC-32 dual purpose canisters (DPCs) containing pressurized water reactor (PWR) fuel assemblies. Summaries of these results are presented in this and a companion paper for this conference. The current paper describes the TSUNAMI-3D calculations performed to generate sensitivity data, and the companion paper discusses the selection of critical experiments applicable for validation of the 11 MPC-32 DPCs considered. The generation of sensitivity data for as-loaded spent nuclear fuel (SNF) DPCs is a challenge given the detailed model of the fuel compositions generated by UNF ST&DARDS. Each fuel assembly is modeled with its own irradiation history in 18 axial nodes, unless the fuel assembly is damaged and thus considered as fresh by design basis. This results in a set of 576 fuel compositions, each of which must be processed separately in a multigroup (MG) calculation. Therefore, a continuous-energy (CE) TSUNAMI-3D method was chosen to alleviate this challenge. Two CE TSUNAMI-3D methods are available in SCALE 6.2.3: the iterated fission probability (IFP) and contribution-linked eigenvalue sensitivity/uncertainty estimation via track-length importance characterization (CLUTCH). Since the IFP method is not feasible because of memory requirements associated with its implementation in SCALE, the CLUTCH method was selected for these calculations. CLUTCH has been implemented in SCALE in parallel, allowing long calculations to be performed in reasonable timeframes. The two primary user inputs necessary for CLUTCH calculations are the F*(r) mesh and the number of latent generations used in determining the F*(r) function. This F*(r) function is used as the importance function for fission chains originating in a given volume element (voxel), and it is calculated using the IFP method in the skipped generations. A large number of skipped generations is thus required to ensure accurate calculation of this importance function. In these calculations, 500 generations were used to calculate the F*(r) function. For more information regarding the calculation of F*(r), see Jones [4]. The remainder of this paper is focused on the selection of the F*(r) mesh and the number of latent generations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bilevel Nodal Behind-the-meter Solar Disaggregation Under Unexpected Extreme Weather Conditions

As the power grid undergoes significant paradigm shift due to the increasing penetration of renewable generation, the ever-growing installation of behind-the-meter (BTM) solar generation in the power grid also has a significant impact on nodal loads, posing challenges on transmission operators. Furthermore, increasing frequent and severe extreme weather events intertwine with ubiquitous BTM solar generations and have amplified the challenges of accurately model nodal load profiles, especially under the lack of ground-truth information for verification. To tackle these challenges, this paper introduces a bilevel model that utilizes year-long data (e.g., proxy solar, zonal load, and individual node load profiles) to disaggregate metered profiles into actual demand and BTM solar generation at each transmission node. The proxy solar not only scales the BTM solar generation of individual nodes but also create a compensation term for enhancing performance on days with unexpected extreme weather events. The proposed algorithm is validated with real-world PJM Interconnection data during unexpected events like the recent Winter Storm Elliott. For quantitative evaluations, a novel Score error is introduced, which is based on mean percentages and load scales and offers a universal assessment method suitable for all nodes and different data formats (e.g., normalized or raw values).

behind-the-meter solar, load disaggregations, load↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Electrical Load Forecasting Over Multihop Smart Metering Networks With Federated Learning

Electric load forecasting is essential for power management and stability in smart grids. This is mainly achieved via advanced metering infrastructure, where smart meters (SMs) record household energy data. Traditional machine learning (ML) methods are often employed for load forecasting, but require data sharing, which raises data privacy concerns. Federated learning (FL) can address this issue by running distributed ML models at local SMs without data exchange. However, current FL-based approaches struggle to achieve efficient load forecasting due to imbalanced data distribution across heterogeneous SMs. Here, this article presents a novel personalized FL (PFL) method for high-quality load forecasting in metering networks. A meta-learning-based strategy is developed to address data heterogeneity at local SMs in the collaborative training of local load forecasting models. Moreover, to minimize the load forecasting delays in our PFL model, we study a new latency optimization problem based on optimal resource allocation at SMs. A theoretical convergence analysis is also conducted to provide insights into FL design for federated load forecasting. Extensive simulations from real-world datasets show that our method outperforms existing approaches regarding better load forecasting and reduced operational latency costs.

Rahman, Ratun [Univ. of Alabama, Huntsville, AL (U↗

Challenges and Solutions for Real-Time Phasor Modeling of Large-scale Distribution Network with High PV Penetration

The conversion process of a practical large-scale feeder data from a quasi-static time series (OpenDSS) model into a real-time phasor model (ePHASORSIM in Opal-RT) is discussed in the paper. The process is implemented using an open source Python software. Previous reported implementations for the conversion process lead to several errors when applied to a larger-scale system such as the one considered here. Hence in this work, we describe the common issues in this conversion and propose a customized solution to enhance the efficiency of the conversion and reduce the complexity in the process. A quantitative validation of the enhanced conversion process is presented in this work using an actual high PV penetration feeder model that consists of 2230 buses, and using actual load and PV profile data. After a detailed analysis, this customized conversion software will be made available as an open source tool and is expected to be helpful for researchers who want to pursue a similar conversion. Solutions to various observed issues such as identifying the lines due to islanded network, representation of full impedance model of transformer/lines as sequential models, complexity in the representation of single phase buses/lines as three phase buses/lines to make it compatible with the simulator platform are discussed. Comparison of power flow and time series simulation results obtained from both OpenDSS and ePHASORsim models show very low errors, validating the accuracy of the proposed conversion process.

14 SOLAR ENERGY↗

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

This report describes example applications and considerations for using the National Renewable Energy Lab’s ResStock and ComStock end use load profiles (EULP). The report begins with an introduction to the three year project, and then provides instructions on accessing the EULP data and considerations for using the EULP and limitations of the data. The remainder of the report is on EULP use cases, including a variety of electricity planning use cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Finalizing Transition to the New Data Center at BNL

Computational science, data management and analysis have been key factors in the success of Brookhaven National Laboratory's scientific programs at the Relativistic Heavy Ion Collider (RHIC), the National Synchrotron Light Source (NSLS-II), the Center for Functional Nanomaterials (CFN), and in biological, atmospheric, and energy systems science, Lattice Quantum Chromodynamics (LQCD) and Materials Science, as well as our participation in international research collaborations, such as the ATLAS Experiment at Europe's Large Hadron Collider (LHC) at CERN (Switzerland) and the Belle II Experiment at KEK (Japan). The construction of a new data center is an acknowledgement of the increasing demand for computing and storage services at BNL in the near term and enable the Lab to address the needs of the future experiments at the High-Luminosity LHC at CERN and the Electron-Ion Collider (EIC) at BNL in the long term. The Computing Facility Revitalization (CFR) project is aimed at repurposing the former National Synchrotron Light Source (NSLS-I) building as the new data center for BNL. The construction of the new data center was finished in 2021Q3, and it was delivered for production in early FY2022 for all collaborations supported by the Scientific Data and Computing Center (SDCC), including STAR, PHENIX and sPHENIX experiments at RHIC collider at BNL, the Belle II Experiment at KEK (Japan), and the Computational Science Initiative at BNL (CSI). This paper highlights the key mechanical, electrical, and networking components of the new data center in its final configuration as used in production since 2021Q4 and gives an overview for the extension of the central network systems into the new data center and the migration of a significant portion of IT load and services from the old data center to the new data center carried out in 20212023, with expected completion of the main phase of the gradual IT equipment replacement and migration from the old data center into the new one set to the end of FY2023 (Sep 30, 2023).

99 GENERAL AND MISCELLANEOUS↗

Advanced Data Center Energy Opportunities: Cloud and Infrastructure CoP - Data Center Energy and Efficiency with AI Adoption

The NLR portion of the "Cloud & Infrastructure CoP - Data Center Energy and Efficiency with AI Adoption" web meeting will cover data center locations, energy use and load growth, best practices, performance metrics, transition to direct liquid cooled data center equipment, and NLR's approach to optimizing data center.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decay Curve Correction Analysis Report

The decay curve analysis that is done on the short-lived radionuclide gas samples is used to differentiate between gaseous radionuclides that have the same characteristic gamma decay energy, 511 kiloelectron-volts (keV). A sample of stack gas is isolated and the total counts in the 511 keV peak are counted repeatedly in 10-second intervals to evaluate the decay rate of the sample over time. Analysis of this decay data required a series of steps. First, a raw data report is generated by the gamma acquisition system, based on an analysis template within the acquisition software. The data report file was then loaded into Microsoft Word, and a macro was used to perform minor formatting (remove colons and insert tabs between data columns) to allow analysis within Excel. The file is then saved as a text file at this point. The text file is then uploaded into Excel and a series of macros are used to add labels, calculate radioactive decay constants, and analyze the gamma decay data using linear regression techniques. The analysis template has been used since 1998 for stack 53000303 (TA-53, building 0003, exhaust stack 03) and 2000 for stack 53000702. The overall process, including the gamma report format and the macros used in Word and Excel for processing the report, had remained unchanged until 2015. In October of 2015, staff made a change to the report template in the gamma acquisition software which resulted in an error in the calculations later performed by the Excel macro. This error was not caught until a more in-depth review of the analysis took place regarding 2020 data. This report covers a much more complete review of the issue that occurred regarding the decay curve analysis, a review of the calculations completed to correct the issue, a review of the updated decay curve analysis process, and recommendations for moving forward.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FOCAL Campaign I: Advanced Wind Turbine Control Strategies

Campaign I of the Floating Offshore-wind Controls Advanced Laboratory Experimental Program (FOCAL) aims to generate a dataset enabling the validation of aerodynamic performance of a scaled turbine mounted on a rigid tower in a fixed condition. The turbine considered in the FOCAL testing campaigns is the IEA-Wind 15MW Reference Wind Turbine. This scaled model is capable of simulating advanced blade-pitch control strategies in a high-quality wind field. The turbine is fully instrumented to record a variety of parameters in real time such as structural loads and dynamics. The test data considered was generated at the University of Maine's Harold Alfond Wind and Wave (W2) testing facility. The Load Cases (LC) considered in this testing campaign are as follows: LC 1.X - Constant wind and blade-pitch with varying rotor speeds LC 2.X - Constant wind and rotor speed with varying blade-pitch LC 3.X - Varying wind with active closed-loop control Detailed properties on the modeled system are found in the following reference: Lenfest E., Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental Program - Campaign I: 1:70 Model-scale Testing of the IEA-Wind 15MW Reference Turbine. UMaine ASCC Report Number 23-40-1183. Details on the results of the verification and validation are found in the following reference: Mendoza, Nicole et al., "Verification and Validation of Model-Scale Turbine Performance and Control for the IEA Wind 15 MW Reference Wind Turbine," Energies, vol. 15, no. 20, 2022, https://doi.org/10.3390/en15207649.

17 WIND ENERGY↗

Uptake and speciation of trace metal inputs to Wetland Soils from Illinois and South Carolina and Stream Sediments from Tennessee

Metals occur in all ecosystems, although their concentrations vary depending on their natural geologic conditions and surrounding human activities. In addition to metals intrinsically present from the geology of a particular system, metals can enter environmental systems from a wide variety of natural and anthropogenic sources, such as sediment re-suspension, mining operations, industrial processes, agricultural activities, and atmospheric deposition. While metals can be toxic at high concentrations, some metals serve as essential micronutrients for biogeochemical processes. Metal transport and availability in engineered and natural water systems depend on processes of adsorption/desorption, oxidation/reduction, dissolution/precipitation, and ligand complexation. Insights into the speciation of metals and their bioavailability will also help advance understanding of the roles of metals in the biogeochemical cycling of nutrients. We conducted batch experiments under anoxic conditions on soils and sediments collected from three different natural aquatic systems to understand their response to influxes of dissolved Cu, Ni and Zn. While soils and sediments from all sites could strongly bind added trace metals, there were substantial differences in trace metal uptake trends between different sites, especially for Cu. There was no distinct correlation between trace metal uptake and the total organic matter, iron, and sulfur content present in the samples. X-ray absorption spectroscopy indicated that the speciation of the freshly added metals taken up by the solids differs substantially from the speciation of the metals originally present in unamended samples. Cu sulfides dominated speciation at low loadings (1 µmol/g), whereas complexation to thiol groups and formation of metallic Cu governed speciation at high loadings (10 µmol/g). For Ni and Zn, adsorption to mineral surfaces and organic matter governed their speciation in materials from most sites. This study suggests that the background speciation of metals in natural aquatic systems is a poor predictor of the speciation and lability of metals introduced to terrestrial aquatic systems from anthropogenic or natural processes. Our findings imply that geochemical processes controlling trace metal speciation may vary considerably with metal loading in different natural systems. Data are provided for marsh wetland soils at Argonne National Laboratory (Marsh 1 and Marsh 2), riparian wetland soils (Riparian 1 and Riparian 2) in the Tims Branch watershed at Savannah River National Laboratory, and stream bed sediments (Stream 1 and Stream 2) from East Fork Poplar Creek near Oak Ridge National Laboratory. Data package includes the results of trace metal uptake experiments conducted on the selected sites for determining their capacity to immobilize metals under different loadings. XANES spectra for Cu, Ni, ad Zn at different loadings are included in the package. The abundance of different trace metal species obtained using linear combination fitting in ATHENA are also included in the data.

54 ENVIRONMENTAL SCIENCES↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗