Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

The electronics, trigger and data acquisition system for the liquid argon time projection chamber of the DarkSide-50 search for dark matter

The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.

Agnes, P.↗

The Phase-2 electronics upgrade of the ATLAS liquid argon calorimeter system

The LHC high-luminosity upgrade in 2024–2026 requires the associated detectors to operate at luminosities about 5–7 times larger than assumed in their original design. The pile-up is expected to increase to up to 200 events per proton bunch-crossing. The current readout of the ATLAS liquid argon calorimeters does not provide sufficient buffering and bandwidth capabilities to accommodate the hardware triggers requirements imposed by these harsh conditions. Furthermore, the expected total radiation doses are beyond the qualification range of the current front-end electronics. For these reasons an almost complete replacement of the front-end and off-detector readout system is foreseen for the 182,468 readout channels. Here, the new readout system will be based on a free-running architecture, where calorimeter signals are amplified, shaped and digitized by on-detector electronics, then sent at 40 MHz to the off-detector electronics for further processing. Results from the design studies on the performance of the components of the readout system are presented, as well as the results of the tests of the first prototypes.

47 OTHER INSTRUMENTATION↗

Electronic energy gap closure and metal-insulator transition in dense liquid hydrogen

Here, using quantum Monte Carlo (QMC) calculations, we investigate the insulator-metal transition observed in liquid hydrogen at high pressure. Below the critical temperature of the transition from the molecular to the atomic liquid, the fundamental electronic gap closure occurs abruptly, with a small discontinuity reflecting the weak first-order transition in the thermodynamic equation of state. Above the critical temperature, molecular dissociation sets in while the gap is still open. When the gap closes, the decay of the off-diagonal reduced density matrix shows that the liquid enters a gapless, but localized, phase: there is a crossover between the insulating and the metallic liquids. Compared to different density functional theory (DFT) functionals, our QMC calculations provide larger values for the fundamental gap and the electronic density of states close to the band edges, indicating that optical properties from DFT potentially benefit from error cancellations.

36 MATERIALS SCIENCE↗

Transmission electron microscope cells for use with liquid samples

This disclosure provides systems, methods, and devices related to transmission electron microscopy cells for use with liquids. In one aspect a device includes a substrate, a first graphene layer, and a second graphene layer. The substrate has a first surface and a second surface. The first surface defines a first channel, a second channel, and an outlet channel. The first channel and the second channel are joined to the outlet channel. The outlet channel defines a viewport region forming a though hole in the substrate. The first graphene layer overlays the first surface of the substrate, including an interior area of the first channel, the second channel, and the outlet channel. The second graphene layer overlays the first surface of the substrate, including open regions defined by the first channel, the second channel, and the outlet channel.

36 MATERIALS SCIENCE↗

Condensed-matter ab initio approach for strongly correlated electrons: Application to a quantum spin liquid candidate

Recently, condensed-matter ab initio approaches to strongly correlated electrons confined in crystalline solids have been developed and applied to transition-metal oxides and molecular conductors. In this paper, an ab initio scheme based on constrained random phase approximations and localized Wannier orbitals is applied to a spin liquid candidate Na{sub 2}IrO{sub 3} and is shown to reproduce experimentally observed specific heat.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron inelastic mean free path in water

Liquid phase transmission electron microscopy (LPTEM) is rapidly developing as a powerful tool for probing processes in liquid environments with close to atomic resolution. Knowledge of the water thickness is needed for reliable interpretation and modelling of analytical studies in LPTEM, and is particularly essential when using thin liquid layers, required for achieving the highest spatial resolutions. Furthermore, the log-ratio method in electron energy-loss spectroscopy (EELS) is often applied in TEM to quantify the sample thickness, which is measured relative to the inelastic mean free path ( λ IMFP ). However, λ IMFP itself is dependent on sample material, the electron energy, and the convergence and divergence angles of the microscope electronoptics. Here, we present a detailed quantitative analysis of the λ IMFP of water as functions of the EELS collection angle ( β ) at 120 keV and 300 keV in a novel nanochannel liquid cell. We observe good agreement with earlier studies conducted on ice, but find that the most widely used theoretical models significantly underestimate λ IMFP of water. We determine an adjusted average energy-loss term E m, water , and characteristic scattering angle θ E, water that improve the accuracy. The results provide a comprehensive knowledge of the λ IMFP of water (or ice) for reliable interpretation and quantification of observations in LPTEM and cryo-TEM studies.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Investigations on a fuzzy process: effect of diffusion on calibration and particle identification in Liquid Argon Time Projection Chambers

Ionization electron diffusion in Liquid Argon Time Projection Chambers (LArTPCs) has typically been considered at the detector design stage, but little attention has been given to its effects on calibration and particle identification. We use a GEANT4-based simulation to study how diffusion impacts these techniques, and give consideration to how this effect is simulated. We find that diffusion can cause a drift-dependent bias to both the median and Most Probable Value (MPV) of dQ/dx distributions. The bias is estimated to be ~2.5% (median) and ~5.0% (MPV) for typical maximum drift times in currently running LArTPCs before adding detector specific considerations such as electric field non-uniformities. This information indicates that these metrics should not be used for calibration without care, contrary to the conventional wisdom. The impact of diffusion on the ability of LArTPCs to separate muons and protons is small, and not expected to pose any problems in future detectors. Diffusion may however be a significant source of systematic uncertainty when separating particles of more similar masses (muons and pions, kaons and protons). Separation of such populations may be improved by implementation of a drift-time dependent particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale imaging of whole cells using a liquid enclosure and a scanning transmission electron microscopy

Nanoscale imaging techniques are needed to investigate cellular function at the level of individual proteins and to study the interaction of nanomaterials with biological systems. We imaged whole fixed cells in liquid state with a scanning transmission electron microscope (STEM) using a micrometer-sized liquid enclosure with electron transparent windows providing a wet specimen environment. Wet-STEM images were obtained of fixed E. coli bacteria labeled with gold nanoparticles attached to surface membrane proteins. Mammalian cells (COS7) were incubated with gold-tagged epidermal growth factor and fixed. STEM imaging of these cells resulted in a resolution of 3 nm for the gold nanoparticles. The wet-STEM method has several advantages over conventional imaging techniques. Most important is the capability to image whole fixed cells in a wet environment with nanometer resolution, which can be used, e.g., to map individual protein distributions in/on whole cells. The sample preparation is compatible with that used for fluorescent microscopy on fixed cells for experiments involving nanoparticles. Thirdly, the system is rather simple and involves only minimal new equipment in an electron microscopy (EM) laboratory.

59 BASIC BIOLOGICAL SCIENCES↗

Electron mobility on the surface of liquid Helium: influence of surface level atoms and depopulation of lowest subbands

The temperature dependence of electron mobility is examined. We calculate the contribution to the electron scattering rate from the surface level atoms (SLAs), proposed in [10]. This contribution is substantial at low temperatures T < 0.5, when the He vapor concentration is exponentially small. We also study the effect of depopulation of the lowest energy subband, which leads to an increase in the electron mobility at high temperature. The results explain certain long-standing discrepancies between the existing theory and experiment on electron mobility on the surface of liquid helium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resonant x-ray emission spectroscopy of liquid water: novel instrumentation, high resolution, and the"map" approach

Techniques to study the electronic structure of liquids are rare. Most recently, resonant x-ray emission spectroscopy (XES) has been shown to be an extremely versatile spectroscopy to study both occupied and unoccupied electronic states for liquids in thermodynamic equilibrium. However, XES requires high-brilliance soft x-ray synchrotron radiation and poses significant technical challenges to maintain a liquid sample in an ultra-high vacuum environment. Our group has therefore developed and constructed a novel experimental setup for the study of liquids, with the long-term goal of investigating the electronic structure of biological systems in aqueous environments. We have developed a flow-through liquid cell in which the liquid is separated from vacuum by a thin Si3N4 or SiC window and which allows a precise control of temperature. This approach has significant advantages compared to static liquids cells used in the past. Furthermore, we have designed a dedicated high-transmission, high-resolution soft x-ray spectrometer. The high transmission makes it possible to measure complete resonant XES"maps" in less than an hour, giving unprecedented detailed insight into the electronic structure of the investigated sample. Using this new equipment we have investigated the electronic structure of liquid water. Furthermore, our XES spectra and maps give information about ultra-fast dissociation on the timescale of the O 1s core hole lifetime, which is strongly affected by the initial state hydrogen bonding configuration.

36 MATERIALS SCIENCE↗

Structural, electronic, and dynamical properties of liquid water by ab initio molecular dynamics based on SCAN functional within the canonical ensemble

We perform ab initio molecular dynamics (AIMD) simulation of liquid water in the canonical ensemble at ambient conditions using the strongly constrained and appropriately normed (SCAN) meta-generalized-gradient approximation (GGA) functional approximation and carry out systematic comparisons with the results obtained from the GGA-level Perdew-Burke-Ernzerhof (PBE) functional and Tkatchenko-Scheffler van der Waals (vdW) dispersion correction inclusive PBE functional. We analyze various properties of liquid water including radial distribution functions, oxygen-oxygen-oxygen triplet angular distribution, tetrahedrality, hydrogen bonds, diffusion coefficients, ring statistics, density of states, band gaps, and dipole moments. We find that the SCAN functional is generally more accurate than the other two functionals for liquid water by not only capturing the intermediate-range vdW interactions but also mitigating the overly strong hydrogen bonds prescribed in PBE simulations. We also compare the results of SCAN-based AIMD simulations in the canonical and isothermal-isobaric ensembles. Our results suggest that SCAN provides a reliable description for most structural, electronic, and dynamical properties in liquid water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Scintillator Materials for Compact Electron Antineutrino Detectors

Developments in the fields of chemistry and materials science provide new components that hold the potential to improve the performance of liquid scintillation electron antineutrino detectors used for the monitoring of nuclear reactors. New compounds can provide for more efficient, stable, and safer operation of these detectors. Current detectors and their detector materials raise issues regarding size, quantum efficiency, stability, and spatial resolution for the vertex detection. For compact detectors (1 m{sup 3} active volume) improvement of these issues with existing liquid scintillation cocktails can be obtained by means of developing stable and efficient neutron capture agents. These agents comprise of boron or lithium containing coordination compounds, in addition advances in fluorescence detection technologies and optimization of solvent characteristics can improve the overall efficiency. Focus points of the new detector material design are to enable a compact, robust, and direction sensitive electron antineutrino detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of frequency and pulse width on electron density, hydrogen peroxide generation, and perfluorooctanoic acid mineralization in a nanosecond pulsed discharge gas-liquid plasma reactor

Plasma electron density and temperature were characterized in a continuous flowing gas-liquid film reactor with argon carrier gas by time-resolved optical emission spectroscopy. The plasma parameters were studied as a function of time for varying pulse widths and frequencies. Pulse frequency was varied between 1 and 10 kHz at 16 kV (input voltage) and 40 ns (pulse width) using an Eagle Harbor Technologies, Inc. (EHT) power supply and 5–100 kHz using an Airity Technologies, LLC (AT) power supply. The pulse width was varied between 40 and 200 ns at 16 kV, 2 kHz with the EHT power supply. Optimal frequencies of 5 and 20 kHz were observed for peak electron density with EHT and AT power supplies, respectively. The peak electron density increased with increasing pulse width between 40 and 200 ns using the EHT power supply. Hydrogen peroxide exiting the reactor in the liquid phase increased with discharge power irrespective of the power supply or pulse parameters. Mineralization of 12.5, 50, and 200 ppm perfluorooctanoic acid (PFOA) dissolved in DI water to fluoride (F - ) correlated to the peak electron density. Glycerol, a liquid-phase hydroxyl radical scavenger, depleted hydrogen peroxide but did not affect PFOA mineralization. CO, a gas-phase hydroxyl radical scavenger, led to a reduction in the formation of F - production, suggesting hydroxyl radicals in the gas-liquid film play a necessary, but not singular, role in mineralization of PFOA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermoelectric-enhanced, liquid-based cooling of a multi-component electronic system

Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled structure, a thermal conduction path coupling the electronic component and the liquid-cooled structure, a coolant loop in fluid communication with a coolant-carrying channel of the liquid-cooled structure, and an outdoor-air-cooled heat exchange unit coupled to facilitate heat transfer from the liquid-cooled structure via, at least in part, the coolant loop. The thermoelectric array facilitates transfer of heat from the electronic component to the liquid-cooled structure, and the heat exchange unit cools coolant passing through the coolant loop by dissipating heat from the coolant to outdoor ambient air. In one implementation, temperature of coolant entering the liquid-cooled structure is greater than temperature of the outdoor ambient air to which heat is dissipated.

42 ENGINEERING↗

Electron Solvation Dynamics and Reactivity in Ionic Liquids Observed by Picosecond RadiolysisTechniques

On time scales of a nanosecond or less, radiolytically-generated excess electrons in ionic liquids undergo solvation processes and reactions that determine all subsequent chemistry and the accumulation of radiolytic damage. Using picosecond pulse radiolysis detection methods, we observed and quantified the solvation response of the electron in 1-methyl-1-butyl-pyrrolidinium bis(trifluoromethylsulfonyl)amide and used it to understand electron scavenging by a typical solute, duroquinone.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron doping a kagome spin liquid

Herbertsmithite, ZnCu 3 (OH) 6 Cl 2 , is a two-dimensional kagome lattice realization of a spin liquid, with evidence for fractionalized excitations and a gapped ground state. Such a quantum spin liquid has been proposed to underlie high-temperature superconductivity and is predicted to produce a wealth of new states, including a Dirac metal at 1/3 electron doping. Here, we report the topochemical synthesis of electron-doped ZnLi x Cu 3 (OH) 6 Cl 2 from x=0 to x=1.8 (3/5 per Cu 2+ ). Contrary to expectations, no metallicity or superconductivity is induced. Instead, we find a systematic suppression of magnetic behavior across the phase diagram. Lastly, our results demonstrate that significant theoretical work is needed to understand and predict the role of doping in magnetically frustrated narrow band insulators, particularly the interplay between local structural disorder and tendency toward electron localization, and pave the way for future studies of doped spin liquids.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-time observation of dynamic structure of liquid-vapor interface at nanometer resolution in electron irradiated sodium chloride crystals

The dynamics and structure of the liquid and vapor interface has remained elusive for decades due to the lack of an effective tool for directly visualization beyond micrometer resolution. Here, we designed a simple liquid-cell for encapsulating the liquid state of sodium for transmission electron microscopic (TEM) observation. The real-time dynamic structure of the liquid-vapor interface was imaged and videoed by TEM on the sample of electron irradiated sodium chloride (NaCl) crystals, a well-studied sample with low melting temperature and quantum super-shells of clusters. The nanometer resolution images exhibit the fine structures of the capillary waves, composed of first-time observed three zones of structures and features, i.e. flexible nanoscale fibers, nanoparticles/clusters, and a low-pressure area that sucks the nanoparticles from the liquid to the interface. Although the phenomenons were observed based on irradiated NaCl crystals, the similarities of the phenomenons to predictions suggest our real-time ovserved dynamic structure might be useful in validating long-debated theoretical models of the liquid-vapor interface, and enhancing our knowledge in understanding the non-equilibrium thermodynamics of the liquid-vapor interface to benefit future engineering designs in microfluidics.

36 MATERIALS SCIENCE↗

Conductivity of metal vapors at the critical point

The conductivity of metal vapors at the critical point and near it has been considered. The liquid-metal conductivity originates in this region. The thermodynamic parameters of the critical point, the density of conduction electrons, and the conductivities of various metal vapors have been calculated within the unified approach. It has been proposed to consider the conductivity at the critical point—critical conductivity—as the fourth critical parameter in addition to the density, temperature, and pressure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗