Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Processing iridium foil targets for the production of radioplatinum isotopes

Dissolving noble metals remains challenging because of their high reduction potentials and tendency to passivate as oxides. This barrier is acute for iridium metal targets used to produce platinum radioisotopes, where post-irradiation processing is costly and hazardous with conventional routes. Here, we report a rapid alkali-fusion method that converts Ir metal directly into chloride media compatible with downstream separations. In the process, an Ir foil is fused with Na 2 O 2 and KCl at temperatures above the KCl melting point; the molten salt enhances heat transfer and facilitates O 2− /Na + transport to the Ir surface, overcoming Ir's oxidation resistance. The fused cake is then cooled and leached in 10 M HCl, yielding Ir in solution without specialized microwave digestion or HF. Pt separation from bulk Ir was evaluated using extraction-chromatography resins. A newly formulated ionic-liquid resin containing Cyphos IL 104 (E104) was compared with two commercial resins (TrisKem TK200 and TK201). All resins achieved >90 % Ir recovery. Pt co-recovery depended on resin chemistry: TK200 recovered 85.9 % Pt, TK201 recovered 54.1 % Pt, and E104 recovered 72.9 % Pt. This study introduces a fast, scalable dissolution route for solid Ir targets and demonstrates resin choices that tune Ir/Pt separation, lowering the barrier to routine production and purification of Pt radioisotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Co-processing catalytic fast pyrolysis oil in an FCC reactor

Here, studies of co-processing catalytic fast pyrolysis (CFP) oil with vacuum gas oil (VGO) are conducted in a Davison Circulating Riser (DCR). The CFP oil (CFPO) for this study was produced by upgrading fast-pyrolysis vapors from pine in an ex-situ fixed-bed reactor. CFPOs were co-processed at up to a volume fraction of 0.05 with VGO at 521 degrees C and 257 kPa. The yields of oil, aqueous phase, tail gas, and coke were measured. The amount of coke was determined from the carbon containing components in the regenerator flue gas. A compositional analysis was conducted with gas chromatography and elemental analyzers. The organic liquids were distilled into gasoline, jet-fuel, diesel, and resid fractions. A biocarbon analysis was conducted on the organic phase and its individual boiling-point fractions. The results show a small decrease in liquid yield and a generally increased gas yield when co-processing CFPO with VGO. The experiments showed that 75%-100% of biocarbon is incorporated into liquid fuels relative to fossil carbon, depending on catalyst and CFPO. The measurements indicate that cracked CFPO components are predominantly included in the jet-fuel and diesel fractions. A techno-economic analysis (TEA) estimated the minimum fuel selling price (MSFP) for fuel-range products derived from FCC co-processing of CFPO at 24 to 29 $\$$/GJ ($\$$2.90 to $\$$3.50 per gasoline-gallon equivalent; GGE) at a yield of 4.87-7.14 GJ/t(biomass) or 40-58 GGE/t.

09 BIOMASS FUELS↗

Co-Processing Catalytic Fast Pyrolysis Oil in an FCC Reactor

Studies of co-processing catalytic fast pyrolysis (CFP) oil with vacuum gas oil (VGO) are conducted in a Davison Circulating Riser (DCR). The CFP oil (CFPO) for this study was produced by upgrading fast-pyrolysis vapors from pine in an ex-situ fixed-bed reactor. CFPOs were co-processed at up to 5 vol% with VGO at 521°C and 2.57 bar. The yields of oil, aqueous phase, tail gas, and coke were measured. The amount of coke was determined from the carbon containing components in the regenerator flue gas. A compositional analysis was conducted with gas chromatography and elemental analyzers. The organic liquids were distilled into gasoline, jet-fuel, diesel, and resid fractions. A biocarbon analysis was conducted on the organic phase and its individual boiling-point fractions. The results show a small decrease in liquid yield and a generally increased gas yield when co-processing CFPO with VGO. For experiments with E-Cat as catalyst, approximately 70% of biocarbon is incorporated into liquid fuels relative to fossil carbon, while more of the biocarbon is contained in tail gas (as carbon dioxide or olefins) and/or coke. The measurements indicate that cracked CFPO components are predominantly included in the jet-fuel and diesel fractions. A techno-economic analysis (TEA) estimated the minimum fuel selling price (MSFP) for fuel-range products derived from FCC co-processing of CFPO at $3 to $4 per gasoline-gallon equivalent (GGE) at a yield of 51 GGE per ton of biomass.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of silver($\mathrm{I}$) ion reduction on the selectivity of olefins, paraffins, and aromatic compounds by gas chromatographic stationary phases consisting of silver($\mathrm{I}$) salts in ionic liquids

We report the olefin/paraffin selectivity offered by ionic liquid (IL) stationary phases can be enhanced through the addition of silver(I) ion, which is well-known to undergo selective complexation with unsaturated compounds. However, such stationary phases often suffer from the loss of chromatographic selectivity as silver(I) ion can be reduced to elemental silver. To maintain the separation performance of silver(I) ion/IL stationary phases, an understanding of factors and conditions that promote the reduction of silver(I) ion is needed. In this study, capillary gas chromatography columns featuring a stationary phase consisting of the 1-decyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([C 10 MIM + ][NTf 2 - ]) IL impregnated with [Ag + ][NTf 2 - ] were examined to investigate the effects of temperature, hydrogen content in exposure gas stream, and time of heating/exposure events on olefin selectivity. Retention factors of representative analytes, such as C 6 olefins and paraffins as well as aromatic compounds, were measured after subjecting the columns to the aforementioned conditions, followed by an evaluation of selectivity factors over time. Selectivity factors of olefins and aromatic compounds were observed to decrease significantly when the stationary phases were heated to temperatures higher than 110°C as well as being subjected to mixed gas streams containing greater than 50 mol% of hydrogen. As constant column heating temperatures were applied under exposure gas mixtures containing hydrogen and nitrogen, a gradual decrease in analyte selectivity factors was observed under prolonged periods of time. However, application of a ternary gas mixture comprised of 25/50/25 mol% hydrogen/nitrogen/methane resulted in an increase in the 3-hexyne/cis-2-hexene selectivity when measured at 120°C for 60 h, due to a smaller decrease in the retention factor of 3-hexyne compared to cis-2-hexene.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sustainable H 2 -Rich Syngas Production via Microwave-Assisted vs Conventional Catalysis of Pinewood

Catalytic gasification of biomass is a promising method for producing hydrogen-rich syngas, which is a valuable resource for cleanenergy applications. In this study, microwave-assisted biomass gasification was compared with conventional thermally driven biomass gasification using pinewood as the biomass without the use of external gasifying agents (such as air, steam, and CO 2 ), under non-catalytic and catalytic conditions. The catalysts consisted of either an iron or a nickel catalyst, and the pinewood used as biomass contained 42% oxygen. This comparative analysis explores the differences in reaction chemistry, product yields, and the role of key reactions such as the water gas shift (WGS) reaction, Boudouard reaction, etc. The gas-phase and liquid-phase products were analyzed using online gas chromatography, and the fresh and spent catalysts were analyzed using X-ray diffraction (XRD) techniques. It was found that microwave-assisted gasification offers advantages in terms of enhanced reaction efficiency, catalyst stability, and hydrogen yield. For the microwave-assisted reaction, the gas yield reached 87%, the char yield was 12.1%, and the tar yield was less than 1% (0.793%) at 550 °C. In contrast, thermal-assisted gasification using the same catalyst produced a gas yield of 85.796%, char yield of 11.438%, and higher tar yield of 2.8% at 900 °C. The higher microwave-assisted performance was attributed to faster heating and better control over reaction conditions, higher reaction rates, and more favorable conditions for hydrogen production.

biomass↗

Suppressing Chemical Corrosions of Lithium Metal Anodes

In this study, the lithium metal anode is essential for next-generation high-energy-density rechargeable Li-metal batteries. Although extensive studies have been performed to prolong the cycle life of Li-metal batteries, the calendar life, which associates with the chemical corrosion of Li metal in liquid electrolytes, has not been quantitatively understood. Here, by combing the titration gas chromatography method and cryogenic focused ion beam, a quantitative relationship between the chemical corrosion rate and electrochemically deposited Li morphology in various liquid electrolyte systems is established. It has been identified that the corrosion rate is dominated by the porosity of the deposited Li. The larger the porosity of deposited Li has, the faster the corrosion rate will be. Strategies to mitigate the chemical corrosion on Li thus to extend the calendar life of Li-metal batteries are further proposed. By strictly controlling the stacking pressure during Li plating, Li deposits with ultra-low porosity can be achieved, suppressing the corrosion rate to 0.08 ± 0.16%/day compared with 1.71 ± 0.19%/day of the high-porosity Li.

25 ENERGY STORAGE↗

A New Process for Small-Batch Purification of the Medical Isotope Molybdenum-99: Non-Technical Overview

The U.S. medical community depends on a reliable supply of the radioisotope molybdenum-99 (Mo-99) for nuclear medical diagnostic procedures. Mo-99's decay product, technetium-99m (Tc-99m), is used in over 40,000 medical procedures in the United States each day to diagnose heart disease and cancer, to study organ structure and function, and to perform other important medical applications. For example, patients undergoing a common procedure—the cardiac “stress test”—likely have benefited from Tc-99m. Historically, Mo-99 was primarily produced through the fission of uranium-235, in the form of highly enriched uranium (HEU) targets irradiated in research and test reactors. HEU is a proliferation-sensitive material that, if diverted or stolen, could be used as a component of a nuclear weapon. NNSA’s Office of Material Management and Minimization (M3) manages the Molybdenum-99 (Mo-99) Program as part of its mission to minimize the use of HEU in civilian applications. The Mo-99 Program assists global Mo-99 production facilities in converting to non-HEU processes and supports the establishment of domestic supplies of Mo-99 without the use of proliferation-sensitive HEU. As part of this program, M3 funds U.S. national laboratories to provide non-proprietary technical support to U.S. companies working to establish non-HEU-based Mo-99 production capabilities. The results of this research are published on OSTI.gov for the benefit of the Mo-99 community and the public. However, it can be difficult for readers without a scientific background to understand and interpret these publications. In order to increase public understanding of the work being done in M3’s Mo-99 Program, this paper aims to provide an overview of a key, recent national laboratory technical publication in terms that can be understood by readers without a technical background. To accomplish this, the paper first explains key scientific concepts—primarily related to chemistry—that provide a foundation for understanding research in this area. This includes chromatography, absorption vs. adsorption, dissolution and precipitation, and liquid-liquid extraction. Drawing on these concepts, the paper then provides an explanation for non-technical audiences of the Argonne National Laboratory publication entitled Recovery of High Specific Activity Molybdenum-99 from Accelerator-Induced Fission on Low-Enriched Uranium for Technetium-99m Generators (Brown, M.A. et al., 2021) and related article Separation and Purification of Mo-99 Produced from Natural U3O8 Targets via Photo-Fission (Brown, M.A. et al., 2021).

Stamler, Bradley↗

Detailed Compositional Comparison of Hydrogenated Vegetable Oil with Several Diesel Fuels and Their Effects on Engine-Out Emissions

The Coordinating Research Council (CRC) is actively involved in developing and applying advanced analytical techniques to the chemical characterization of transportation fuels. Here, this article complements a 2017 CRC project to quantify and compare the effects of a commercially available renewable diesel fuel (hydrotreated vegetable oil [HVO]) and an ultralow sulfur diesel (ULSD) fuel on engine-out gaseous and particulate matter (PM) emissions from a light-duty vehicle. Results showed that the combustion of HVO fuel had an advantage over ULSD in terms of lowering engine-out emissions (THC, CO, NO x , etc.). Furthermore, this advantage is strongly related to the fuel composition. This article summarizes the results of advanced and comprehensive analytical tests on the same ULSD and HVO fuels and attempts to connect some of the engine-out emissions results to fuel composition and specific chemical structures. A variety of test methods, generally unavailable in combination, were employed, such as one-dimensional (1D) and two-dimensional (2D) gas chromatography (GC), nuclear magnetic resonance spectroscopy (NMR), and high-pressure solid-liquid phase transition experiments. In summary, the ULSD sample was found to have representation across the expected set of hydrocarbon classes typical for the sample type. Interestingly, a high content of cycloparaffins (>50 wt%) and a very low content of diaromatics (~2 wt%) were present. While not without precedent, these are higher and lower, respectively, than typically found for commercial ULSD compositions. In contrast, HVO was found to consist of only two hydrocarbon classes: n-paraffins (~10 wt%) and iso-paraffins (~90 wt%), both predominantly in a narrow carbon atom number range (i.e., C14–C18). HVO engine-out emissions results for the LA-92 and steady-state testing can be tracked to the narrow carbon atom number range of the n-paraffins and iso-paraffins, which result in a high cetane number fuel having a narrow distillation range. Previously, the low-temperature operability of HVO has been a concern, but that appears not be the case for this particular HVO. HVO and ULSD were evaluated at pressures up to ~275 MPa and found to have comparable solid-liquid equilibria despite significant compositional differences.

09 BIOMASS FUELS↗

Online collection of LC effluent as droplets for automatic injection into ICP-MS

A sample introduction technique was developed to allow for online, dropwise injection of effluent into a mass spectrometer (MS). This allowed for the coupling of chromatography systems that were not driven by pumps without altering the set-up or separation performance. This capability combined the benefits of coupling separation and measurement while also enabling accurate chromatographic evaluation that would generally be performed offline. The incorporation of a flowing rinse into the system made dropwise resolution possible for any liquid capable of forming drops under ambient conditions. The technique was demonstrated utilizing gas pressurized extraction chromatography (GPEC) and inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS) to illustrate the qualitative applications for rapid separation development and procedure evaluation. This method's quantitative applications were evaluated using single and double isotope dilution mass spectrometry (IDMS) with an external mass bias correction to measure analytes across entire elutions including volumes as small as single drops. In conclusion, the total neodymium values afforded by both single and double IDMS were within the uncertainty of the calculated value for evaluation of full elution peaks and for most of the single drops analyzed that reached above 10k cps Nd-144.

GPEC↗

Fluorinated ionic liquids as gas chromatographic stationary phases for the separation of volatile per- and polyfluoroalkyl substances

Background Here, the production of fluorinated organic compounds in the manufacturing, semiconductor, and pharmaceutical industries has increased exponentially over the past decade. This rapid growth has created an urgent need for efficient chromatographic platforms capable of selectively separating these compounds from complex mixtures, not only to support industrial quality control and waste management practices, but also to enable reliable environmental monitoring of volatile fluorinated contaminants. Conventional GC stationary phases lack the fluorophilic interactions needed for highly fluorinated analytes. Consequently, there is a clear demand for specialized stationary phases designed to improve chromatographic retention and selectivity for these compounds. Results Three stationary phases composed of fluorinated ionic liquids (ILs) with varied extent of fluorination were prepared to study fluorophilic interactions with fluorinated/non-fluorinated probe molecules by gas chromatography (GC). IL stationary phases featuring linear and branched perfluoroalkyl moieties, as well as a branched alkyl moiety, were systematically investigated. Chromatographic performance was examined using fluorinated compounds and their hydrocarbon analogs, including CF 3 -substituted aromatics, aliphatic alcohols, fluorotelomer alcohols (FTOHs), and perfluoroalkenes. Measurements on 5 m and 20 m columns revealed that the IL possessing branched alkyl provided stronger dispersive and hydrogen bonding interactions toward non-fluorinated aromatic and long-chain alcohols, whereas the fluorinated ILs enhanced retention of highly fluorinated FTOHs and perfluorodecene. Comprehensive two-dimensional GC (GC × GC), using a nonpolar primary column coupled with secondary columns featuring cross-bonded poly(trifluoropropylmethyl siloxane) (Rtx-200 ms), the branched fluorinated IL, or the branched non-fluorinated IL, highlighted complementary selectivity with the branched fluorinated IL providing the strongest interactions with fluorinated analytes. Significance These results demonstrate that fluorinated IL stationary phases are promising alternatives to conventional polysiloxane stationary phases for improving the separation of per- and polyfluoroalkyl substances and related fluorinated compounds. By correlating IL structure with fluorophilic interactions, this work establishes design principles for GC stationary phases that enable enhanced selectivity for highly fluorinated analytes while maintaining complementary interactions with non-fluorinated compounds.

Comprehensive two-dimensional GC↗

Analysis of Glycolate in Radioactive Waste by Ion Chromatography (IC) and Proton Nuclear Magnetic Resonance (H NMR)

Here, in preparation for implementing the Nitric-Glycolic (NG) acid flowsheet for the Savannah River Site (SRS) Liquid Waste System (LWS), analytical methods for determining glycolate at low concentration, below 20 mg/L in radioactive samples, were developed to support system management and safety. To accommodate the wide range of LWS matrix conditions, two alternative methods were developed, refined, and demonstrated for glycolate analysis in radioactive waste samples: ion chromatography (IC) and a proton nuclear magnetic resonance (H NMR). Investigators validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. The deployed IC method is applicable in low to moderate ionic strength samples and requires sample pretreatment using a Dionex OnGuard II H + cartridge. The deployed H NMR method is more labor intensive but provides options for a broader range of matrices. Based on the results, high quality glycolate analysis of the Defense Waste Processing Facility (DWPF) condensate in Tank 22 is feasible by IC down to approximately 12 mg/L. Using H NMR, glycolate may be determined to 8 mg/L or lower depending on the run time with the potential for broader applicability of the method to higher ionic strength conditions in other tanks of the SRS LWS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Identifying Green Solvent Mixtures for Bioproduct Separation Using Bayesian Experimental Design

Liquid–liquid extraction (LLE) is a widely used technique for the separation and purification of liquid-phase products with applications in various industries, including pharmaceuticals, petrochemicals, and renewable chemistry. A critical step in the design of an LLE process is the selection of appropriate solvents. This study presents a new methodology for identifying solvent mixtures for bioproduct separation using Bayesian experimental design (BED). Motivated by the need for environmentally friendly and effective separation methods, we address the challenge of selecting solvent systems that balance separation efficiency, selectivity, and environmental impact while also tackling the difficulty of separating multiple bioproducts using complex solvent systems. Our approach specifically seeks to predict product partition coefficients (log10 Kp values) as thermodynamic parameters underlying solvent selection. The iterative approach integrates Bayesian optimization with experimental measurements to guide solvent selection and leverages COSMO-RS simulations to enhance high-throughput experimentation. Using the design of solvent systems for the separation of lignin-derived aromatic products via centrifugal partition chromatography (CPC) as a case study, we show that within seven iterations/cycles of the methodology, we can identify new mixtures of green solvents that align with CPC design principles. Furthermore, these results demonstrate the efficacy of the BED framework in optimizing green solvent systems for complex separations, highlighting the potential of this method to advance the field of green chemistry and contribute to the development of sustainable industrial processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid separation of radiopure yttrium-91 for tracer studies from mixed fission products and uranium

A novel, single step method for isolating 91 Y from irradiated uranium and mixed fission products has been developed based on the commercially available Eichrom LN resin. The separation procedure allows for loading an LN resin column with an irradiated uranium solution, containing mixed fission products, in dilute HCl where both uranium and yttrium are retained on the resin. Eluting dilute (0.5–1 M) HCl will strip the majority of fission products. Furthermore, increasing the concentration to 3 M HCl will elute 91 Y without the presence of any other fission products. Finally, uranium can be recovered by passing concentrated HCl through the column.

Chromatography↗

Glycolate Analysis in Tank 22: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

Researchers developed and tested a range of techniques to support a low mg/L Limit of Quantitation (LOQ) of glycolate in radioactive Tank 22 waste solution by Ion Chromatography (IC) and by proton NMR. For the IC method, Dionex OnGuard II cartridges were tested as a means of removing alkali earth and transition metals that can interfere during ion chromatography applications especially when analyzing for low-concentration, chelating analytes. Additionally, concentrations of nitrate in the raw Tank 22 sample (5,000 to 10,000 mg/L) were managed by using reasonable levels of sample dilution. The resulting IC performance quality was enhanced by improving the baseline, increasing sensitivity [Limit of Quantitation (LOQ) of 12 mg/L and Limit of Detection (LOD) of 4.0 mg/L], and resolving analytes into well-defined Gaussian peaks when using the Dionex OnGuard II H⁺ cartridges to remove matrix interferences. High concentrations of nitrate limited the performance of the IC method. To achieve an acceptable baseline, samples with high nitrate content require more dilution, resulting in higher detection limits. Tests on samples with higher concentrations of nitrate (Tank 30 and 32 supernate with approximately 150000 mg/L nitrate) suggested that IC detection limits for glycolate in these samples would be > 500 mg/L. Thus, an LOQ of 12 mg/L is not feasible by this IC method on evaporator feed samples. An alternative method of glycolate analysis, using proton nuclear magnetic resonance (H NMR), was developed by the research team. In initial tests, the H NMR technique provided reasonable quantitation of glycolate in Tank 22 conditions by direct observation of the liquid. The H NMR method may provide improved detection limits for solutions with higher nitrate concentrations. We recommend further development of this analysis for high nitrate LWS samples such as evaporator feed and evaporator drop tank content. A method for pretreatment of samples using crystalline silicotitanate (CST) was developed and tested. The objective of the pretreatment was to facilitate analysis of samples with higher levels of radioactivity. The pretreatment did not influence the glycolate concentration in solution, and the pretreatment is projected to reduce Cs 137 activity in a sample by a factor of 16,200. The double strike CST pretreatment was demonstrated and would allow milliliters of higher activity samples to be transferred from the Shielded Cells and handled in a containment unit for glycolate analysis. The various studies validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. Based on the results, high quality glycolate analysis of Tank 22 is feasible down to approximately 12 mg/L, with the potential for broader applicability of the methods to other conditions in the Savannah River Site Liquid Waste System (LWS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Extraction Chromatography Resins for Metal Ion Separations in Analytical Radiochemistry

Extraction chromatography resins are widely used in pretreatment for such as the analysis of radionuclides and metal ions, as well as the quantification of isotopes. These resins have been developed for the purpose of improving selectivity, reducing the generation amount of waste liquid, and performing simpler and faster separation compared with other separation methods such as solvent extraction, ion exchange, and coprecipitation. This paper explains, in an easy-to-understand manner, this extraction chromatography, including extractants, diluents, solid supports, etc. (A.O.)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗