Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Search for nonvirialized axions with 3.3 − 4.2 μ ⁢eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth’s motion. Here, we report an exclusion on the local axion dark matter density in narrow flows of ρ a ≳ 0.03 GeV/cm 3 and ρ a ≳ 0.004 GeV/cm 3 for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range 3.3−4.2 μeV. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Metagenome-assembled genomes from Slate River floodplain sediments near Crested Butte, CO, USA (June 2018)

Microorganisms play a key role in cycling nutrients and contaminants in the terrestrial environment depending on their genetic potential. Here, we present metagenome-assembled genomes (MAGs) for the bacterial and archaeal community in floodplain sediment samples taken June 2018 at two locations (OBJ1 and OBJ2) near the confluence of the Oh-Be-Joyful Creek and Slate River. The site is one of the field sites in focus for the SLAC National Accelerator Laboratory Groundwater Quality Science Focus Area (SFA) program. Sediment samples from a deep soil pit were collected from 50 to 150 cm depth below surface at discrete depths every 20 cm for microbial analyses. A total of 12 metagenomes were sequenced through the Joint Genome Institute (JGI) and can be found under Genomes Online Database (GOLD) sequencing project: Gs0142591. Metagenomes were assembled, binned, and refined using metawrap to generate MAGs (>50% complete and < 10% contamination based on checkM scores). This dataset includes a zip file of 1233 MAG fasta files and a csv file with quality, taxonomic classification (Genome Taxonomy Database Release RS220), and metagenome accessions for MAGs. This dataset also includes a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata and a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.Part of this work was performed at SLAC Accelerator Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-76SF00515.

54 ENVIRONMENTAL SCIENCES↗

Metagenome-assembled genomes from East River floodplain sediments near Crested Butte, CO, USA (June to September 2017)

Microorganisms play a key role in cycling nutrients and contaminants in the terrestrial environment depending on their genetic potential. Here, we present metagenome-assembled genomes (MAGs) for the bacterial and archaeal community in floodplain sediment samples taken in 2017 in June (flooded conditions) and September (drained conditions) at two locations (MCB1 and MCB3) in an active meander (Meander C) of the East River. Sediment cores were collected from 2 depths, a near-surface, generally unsaturated depth (15-40 centimeter (cm) depth below surface) and a deeper depth influenced by flooding with redoximorphic features (50-88 cm depth below surface). Sediments were homogenized from the ~10 cm cores for microbial analyses. A total of 24 metagenomes were sequenced through the Joint genome institute (JGI) corresponding to 8 samples sequenced in triplicate. These metagenomes can be found under Genomes Online Database (GOLD) sequencing project: Gs0151851. Metagenomes were assembled, binned, and refined using metawrap to generate MAGs (>50% complete and < 10% contamination based on checkM scores). This dataset includes a zip file of 405 MAG fasta files and a csv file with quality, taxonomic classification (Genome Taxonomy Database Release RS220), and metagenome accessions for MAGs. This dataset also includes a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata and a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. Part of this work was performed at SLAC Accelerator Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-76SF00515.

54 ENVIRONMENTAL SCIENCES↗

Towards Efficient Alternating Current Optimal Power Flow Analysis on Graphical Processing Units

We present a solution of sparse ACOPF analysis on GPU. In particular, we discuss the performance bottlenecks and detail our efforts to accelerate the linear solver, a core component of ACOPF that dominates the computational time. ACOPF solutions of two large-scale systems, synthetic Northeast (25,000 buses) and Eastern (70,000 buses) \cite{birchfield2017tamu-cases} on GPU show promising speed-up compared to CPU based solution using a state-of-the-art solver. To our knowledge, this is the first result demonstrating acceleration of sparse ACOPF on GPUs.

Power grid analysis, GPU↗

Beam power scale-up in micro-electromechanical systems based multi-beam ion accelerators

We report on the development of multi-beam RF linear ion accelerators that are formed from stacks of low cost wafers and describe the status of beam power scale-up using an array of 120 beams. The total argon ion current extracted from the 120-beamlet extraction column was 0.5 mA. The measured energy gain in each RF gap reached as high as 7.25 keV. We present a path of using this technology to achieve ion currents >1 mA and ion energies >100 keV for applications in materials processing.

47 OTHER INSTRUMENTATION↗

Numerical modeling of a proton spin-flipping system in the spin transparency mode at an integer spin resonance in JINR's Nuclotron

In this paper we propose a lattice insertion for the Nuclotron ring called a “spin navigator” that can adjust any direction of the proton polarization in the orbital plane using weak solenoids. The polarization control is realized in the spin transparency mode at the energy of 108 MeV, which corresponds to the integer spin resonance γ G = 2. The requirements on the navigator solenoid fields are specified considering the criteria for stability of the spin motion during any manipulation of the polarization direction in an experiment. Additionally, this paper presents the results of numerical modeling of the proton spin dynamics in the Nuclotron ring operated in the spin transparency mode. The verified spin navigator is aimed at an experimental study of a spin-flipping system using the Nuclotron ring. The results are relevant to the NICA (JINR), EIC (BNL) and COSY (FZJ) facilities where the spin transparency mode can be applied for polarization control.

47 OTHER INSTRUMENTATION↗

Energy Characterization of the UMD Electron Accelerator

Multiple different groups at Los Alamos National Laboratory have a cited interest in understanding the effects of ionizing radiation in materials. Of especial interest to the ISR division is understanding the effects in materials that are used in the space environment, where radiation is omnipresent and impossible to fully shield from. Development is under way to simulate the effects of radiation damage in detectors and electronics, primarily with particle transport codes such as Geant4 and RAMPART, a code that provides a user friendly interface to Geant4. However, these simulations need benchmarking to experimental tests, some of which have been performed at a variety of small electron accelerator facilities. One of these facilities is the Linear Electron Accelerator at the University of Maryland Radiation Facilities. This facility can provide electron beams on the order of 100 mA delivered in tight macropulse bunches, which allows for experiments where the behavior of electronics is monitored as a function of pulse number. While the beam rates per macropulse of this accelerator is monitored during an experiment via a current pick-off connected to a large graphite beamstop, the energy distribution of this electron beam is not measured during the experiment and has not been well characterized. The energy distribution of the beam is pertinent for these types of experiments, since dose is directly related to energy deposited in a medium. Further, these experiments are performed in open air and sample placement in the room can dictate what dose rate they receive per macropulse. We have created simulated dosemaps for the UMD vault room, but these simulations assume a given energy of the beam, both for calculating the dose and to simulate how much the beam diverges in the air. There have been two attempts now to characterize this accelerator beam energy with a plate type spectrometer, including the most recent experiment earlier this year to quantify the beam energy distribution. These results will also be compared to a dosimetry experiment performed by collaborators at the UMD facility, the details of which are described in Reference. Understanding the electron beam energy is important for future experiments, because the energy directly impacts the dose and radiation damage given to a sample and is important for properly simulating the electron beam when comparing simulation to experiment.

43 PARTICLE ACCELERATORS↗

Commissioning Status of the Linac for the Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams will be completed in late 2021. Here, we report here on the current efforts to commission the first stages of the 200-MeV/u superconducting, continuous wave heavy-ion linac. The statuses of the cryogenic plant and its distribution system, the accelerator cryomodule commissioning and operations, the ion source and front end transport development, the radio-frequency quadrupole commissioning, and then beam dynamics development to support high-power operation are reviewed. Plans for commissioning the remainder of the linac systems are presented.

43 PARTICLE ACCELERATORS↗

Historical Pattern Analysis of Global Geothermal Power Capacity Development: Preprint

Between 1913 and 1958, Italy was the only country with an operational geothermal power plant until New Zealand installed its first plant in 1958. At present, 24 countries are involved in the geothermal power market, and they have a combined installed capacity of 16,127 GW. This study analyzes the historical patterns of geothermal power capacity in the world and in individual countries to investigate the ideal global geothermal development pattern by examining the annual cumulative capacity (ACC) and the annual capacity addition (ACA) graphs of the historical development of geothermal power capacity in 24 countries. First, the global patterns are analyzed using these graphs in five periods (1945-1957, 1958-1976, 1977-1991, 1992-2002, and 2003-2020) that are marked by a series of characteristics of ACA peaks separated by two major troughs. Then, five characteristic patterns are developed in five periods globally. These patterns correspond to the early-stage linear, the first acceleration, the first steady-state linear, the second acceleration, and the second steady-state linear developments. A positive relationship exists between global patterns and the 5-year shifted oil-price curve: two major factors influenced global development: 1) increasing oil prices and increasing awareness of global climate change, and 2) global development of geothermal power. Last, we investigate these patterns in each country. The top ten countries, which comprise 93.3% of the world's total installed capacity are separated into five groups based on the availability and characteristics of patterns globally developed in five periods. Group-1 (the United States) has an installed capacity of 3,794 MW, Group-2 (Mexico and Philippines) 963-1935 MW, Group-3 (New Zealand, Italy, Iceland, and Japan) 601-1,037 MW, and Group-4 (Indonesia, Kenya, and Turkiye) 944-2,356 MW. The remaining 14 countries (6.7%), which are called Group 5, are still in an immature stage and have installed capacities of 7-262 MW and are not involved in pattern analysis. Overall, geothermal power in the world is in its third stage of development, which had its peak development after 1977. A fourth development peak may be expected to occur after this through business-as-usual cases. The biggest barrier to the development of the global geothermal power market is the risk associated with exploration and drilling. If risk mitigation systems and funds are employed, the growth of geothermal power production projects could accelerate.

GEOTHERMAL ENERGY↗

Historical Pattern Analysis of Global Geothermal Power Capacity Development

Between 1913 and 1958, Italy was the only country with an operational geothermal power plant until New Zealand installed its first plant in 1958. At present, 24 countries are involved in the geothermal power market, and they have a combined installed capacity of 16,127 GW. This study analyzes the historical patterns of geothermal power capacity in the world and in individual countries to investigate the ideal global geothermal development pattern by examining the annual cumulative capacity (ACC) and the annual capacity addition (ACA) graphs of the historical development of geothermal power capacity in 24 countries. First, the global patterns are analyzed using these graphs in five periods (1945-1957, 1958-1976, 1977-1991, 1992-2002, and 2003-2020) that are marked by a series of characteristics of ACA peaks separated by two major troughs. Then, five characteristic patterns are developed in five periods globally. These patterns correspond to the early-stage linear, the first acceleration, the first steady-state linear, the second acceleration, and the second steady-state linear developments. A positive relationship exists between global patterns and the 5-year shifted oil-price curve: two major factors influenced global development: 1) increasing oil prices and increasing awareness of global climate change, and 2) global development of geothermal power. Last, we investigate these patterns in each country. The top ten countries, which comprise 93.3% of the world's total installed capacity are separated into five groups based on the availability and characteristics of patterns globally developed in five periods. Group-1 (the United States) has an installed capacity of 3,794 MW, Group-2 (Mexico and Philippines) 963-1935 MW, Group-3 (New Zealand, Italy, Iceland, and Japan) 601-1,037 MW, and Group-4 (Indonesia, Kenya, and Turkiye) 944-2,356 MW. The remaining 14 countries (6.7%), which are called Group 5, are still in an immature stage and have installed capacities of 7-262 MW and are not involved in pattern analysis. Overall, geothermal power in the world is in its third stage of development, which had its peak development after 1977. A fourth development peak may be expected to occur after this through business-as-usual cases. The biggest barrier to the development of the global geothermal power market is the risk associated with exploration and drilling. If risk mitigation systems and funds are employed, the growth of geothermal power production projects could accelerate.

GEOTHERMAL ENERGY↗

Correcting Magnetic-Field Diffusion Effects in Beam Position Monitors

Beam position monitors (BPMs) provide timeresolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). The data from some types of BPMs can be influenced by magnetic field diffusion into the surrounding metal. We derive an estimate of the correction factor from first principles, and show how it is applied in practice to nearly eliminate the effect from the data.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors III: Application to DARHT-II Beam Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors II: Application to Calibration Single-Pulse Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. From first principles, we have derived the perturbation to BPM measurements due to this effect. The theoretical framework was used to design an algorithm for signal correction that does not require knowledge of the time history of the magnetic flux being measured. Corrected signals based on that process compared favorably with the know reference signals in a laboratory calibration test sequence.

43 PARTICLE ACCELERATORS↗

Linear colliders based on laser-plasma accelerators

Laser-plasma accelerators are capable of sustaining accelerating fields of 10–100 GeV/m, 100–1000 times that of conventional technology and the highest fields produced by any of the widely researched advanced accelerator concepts. Laser-plasma accelerators also intrinsically accelerate short particle bunches, several orders of magnitude shorter than that of conventional technology, which leads to reductions in beamstrahlung and, hence, savings in the overall power consumption to reach a desired luminosity. These properties make laser-plasma accelerators a promising accelerator technology for a more compact, less expensive high-energy linear collider providing multi-TeV polarized leptons. In this submission to the Snowmass 2021 Accelerator Frontier, we discuss the motivation for a laser-plasma-accelerator-based linear collider, the status of the field, and potential linear collider concepts up to 15 TeV. Herein, we outline the research and development path toward a collider based on laser-plasma accelerator technology, and highlight near-term and mid-term applications of this technology on the collider development path. The required experimental facilities to carry out this research are described. We conclude with community recommendations developed during Snowmass.

43 PARTICLE ACCELERATORS↗

An Improved Beam Position Monitor for Scorpius and the DARHT Multi-Pulse Test Line

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). A frequently used BPM detector is the B-dot loop, which generates a signal from the EMF generated by the time varying magnetic flux through the loop. We have developed a second generation BPM that avoids previously observed diffusion effects in earlier stainless steel through the use of exceptionally high conductivity copper alloy for its construction.

43 PARTICLE ACCELERATORS↗

Prospects for Machine Learning and Pulse Shaping on the Scorpius Accelerator [Poster]

The Advanced Sources and Detectors (ASD) project aims to build Scorpius, a multi pulse linear induction accelerator capable of delivering a 1.4 kA electron beam at energies up to 24 MeV. One of the primary advancements of Scorpius is the use of solid state pulsed power (SSPP) to provide flexibility in pulse shaping by independently triggering 45 individual stages stacked in each of 984 line replaceable units (LRU), with 168 LRUs dedicated to the injector. By leveraging circuit modeling of each LRU stage, a machine learning model of the SSPP will be developed to allow for optimization of the pulse shape, including pulse flattening and reflection mitigation. Particle-in-cell simulations of Scorpius have, for example, demonstrated that reducing reflections during multi-pulse operation mitigates beam spill by preventing the production of off-energy electrons between pulses, thereby abating stimulated ion desorption from the wall and beam charge neutralization. This machine learning model will be validated and tuned with experimental data collected from the Scorpius injector and Integrated Test Stand

43 PARTICLE ACCELERATORS↗

High-accuracy absolute magnetometry with application to the Fermilab Muon g-2 experiment

We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The B-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification as an absolute scalar magnetometer are described. The device was tested at B = 1.45 T but can be modified for a range exceeding 1–3 T. The magnetometer was used to calibrate other NMR magnetometers and measure absolute magnetic field magnitudes to an accuracy of 19 parts per billion as part of a measurement of the muon magnetic moment anomaly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗