Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light emitting diode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

LED Lighting and Plant Growth: Supplemental LED Effects on Development

The growth of plants aboard the International Space Station (ISS) will play a pivotal role in advancing human space exploration to further uncharted destinations. Not only will plants be useful for oxygen production and carbon dioxide reduction, they will also serve as a supplemental food source for the astronaut diet. Research indicates that the most efficient way for these crops to be grown is by using electric lighting – specifically light-emitting diodes (LED) due to their several unique advantages. One of these advantages includes the potential for selecting certain wavelengths. By isolating certain lights, the effects of specific wavelengths on plant growth can be made clearer. This research project examined plant morphology, chlorophyll, biomass production, and nutrient synthesis in ‘Outredgeous’ red romaine lettuce grown under six LED light treatments of white (W), W + blue (B), W + green (G), W + red (R), W + far red (FR), and a Heliospectra lamp (Helio) (-composed of B+G+R+FR LEDs without W LEDS-). It was consistently found that the lettuce grown under the Helio, W + FR, W + R, and W + G treatments all showed improved physiology in terms of shoot length, shoot diameter, fresh mass, and dry mass relative to the W control. The Helio, W + FR, and W + G treatments exhibited significantly larger leaf areas while the Helio and W + FR treatments also produced more leaves on average at 28 days after planting (DAP). The W (control) and W + B treatments showed the highest accumulation of chlorophyll at 28 DAP. In conclusion, lettuce grown under the Helio treatment may be the overall most beneficial for supplementing the astronaut diet in terms of total edible biomass produced in a 28 day crop cycle.

LED↗

Optical device for in-line and real-time monitoring of microorganisms

A multi-wavelength laser diode based optical sensor system capable of monitoring the dynamics and physiological changes of a microorganism culture in real-time. The microorganism culture from a microorganism production chamber is pumped to a flow chamber. Laser diodes emit light at certain wavelengths through the flow chamber, which is sensed by photodiodes. A laser control circuitry is operatively connected to the laser diodes and a signal conditioning circuitry is operatively connected to the photodiodes. A microprocessor reads and records voltage signals corresponding to the wavelengths. A data acquisition system converts said voltage signals into measurements of biological parameters, which are displayed on a graphical user interface and allow a user to monitor the measurements in real time.

47 OTHER INSTRUMENTATION↗

Ground Facility for Vicarious Calibration of Skyborne Sensors

An automated ground facility, for vicarious radiometric calibration of airborne and spaceborne sensors of visible and infrared light has been established. In the term "vicarious calibration," "vicarious" is used in the sense of "in place of another," signifying "in place of laboratory calibration." Vicarious calibration involves the use of ground truth in the form of measurements by ground-viewing radiometers, a Sun-viewing photometer, and meteorological instruments positioned in a ground target area. The instrumentation at the facility includes a light-emitting-diode spectrometer (LSpec), which consists of eight tripod-mounted, ground-viewing radiometer units containing LEDs biased to operate as photodetectors (instead of light emitters) at their respective wavelengths. The LSpec provides an essentially continuous stream of measurements at eight discrete wavelengths. These are merged with spectral surface-reflectance measurements made on occasional site visits to obtain temporally continuous coverage with high spectral resolution.

Bruegge, Carol↗

Using Light to Treat Mucositis and Help Wounds Heal

A continuing program of research and development is focusing on the use of controlled illumination by light-emitting diodes (LEDs) to treat mucositis and to accelerate healing of wounds. The basic idea is to illuminate the affected area of a patient with light of an intensity, duration, and wavelength (or combination of wavelengths) chosen to produce a therapeutic effect while generating only a minimal amount of heat. This method of treatment was originally intended for treating the mucositis that is a common complication of chemotherapy and radiation therapy for cancer. It is now also under consideration as a means to accelerate the healing of wounds and possibly also to treat exposure to chemical and radioactive warfare agents. Radiation therapy and many chemotherapeutic drugs often damage the mucosal linings of the mouth and gastrointestinal tract, leading to mouth ulcers (oral mucositis), nausea, and diarrhea. Hyperbaric-oxygen therapy is currently the standard of care for ischemic, hypoxic, infected, and otherwise slowlyhealing problem wounds, including those of oral mucositis. Hyperbaric-oxygen therapy increases such cellular activities as collagen production and angiogenesis, leading to an increased rate of healing. Biostimulation by use of laser light has also been found to be effective in treating mucositis. For hyperbaricoxygen treatment, a patient must remain inside a hyperbaric chamber for an extended time. Laser treatment is limited by laser-wavelength capabilities and by narrowness of laser beams, and usually entails the generation of significant amounts of heat.

Ignatius, Robert W.↗

Modular, Microprocessor-Controlled Flash Lighting System

A microprocessor-controlled lighting system generates brief, precisely timed, high-intensity flashes of light for scientific imaging at frame rates up to about 1 kHz. The system includes an array of light-emitting diodes (LEDs) that are driven in synchronism with an externally generated timing signal (for example, a timing signal generated by a video camera). The light output can be varied in peak intensity, pulse duration, pulse delay, and pulse rate, all depending on the timing signal and associated externally generated control signals. The array of LEDs comprises as many as 16 LED panels that can be attached together. Each LED panel is a module consisting of a rectangular subarray of 10 by 20 LEDs of advanced design on a printed-circuit board in a mounting frame with a power/control connector. The LED panels are controlled by an LED control module that contains an AC-to-DC power supply, a control board, and 8 LED-panel driver boards. In prior LED panels, the LEDs are packaged at less than maximum areal densities in bulky metal housings that reduce effective active areas. In contrast, in the present LED panels, the LEDs are packed at maximum areal density so as to afford 100-percent active area and so that when panels are joined side by side to form the array, there are no visible seams between them and the proportion of active area is still 100 percent. Each panel produces an illuminance of .5 x 10( exp 4) lux at a distance of 5.8 in. (approx.1.6 cm). The LEDs are driven according to a pulse-width-modulation control scheme that makes it safe to drive the LEDs beyond their rated steady-state currents in order to generate additional light during short periods. The drive current and the pulse-width modulation for each LED panel can be controlled independently of those of the other 15 panels. The maximum allowable duration of each pulse of drive current is a function of the amount of overdrive, the total time to be spent in overdrive operation, and the limitations of the LEDs. The system is configured to limit the overdrive according to values specific to each type of LED in the array. These values are coded into firmware to prevent inadvertent damage to the LED panels.

Kiefer, Dwayne↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (.50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Laboratory Evaluation of Tunable White LEDs for Circadian Lighting in Commercial Offices

Tunable white Light-Emitting Diode (LED) systems that allow users to control Correlated Color Temperature (CCT) are often marketed for circadian health, which is an emerging priority in commercial office lighting. However, the energy impacts of meeting circadian criteria with standard non-tunable LEDs and with tunable white LEDs are not well understood. The goals of this project were to implement select commercial lighting systems, including tunable white LEDs, to meet visual and circadian criteria in an office environment, and to quantify lighting performance and energy usage. Most recent studies on tunable white LEDs, circadian lighting strategies, and energy impacts have relied on computer simulations and models. While little research has directly measured tunable LED energy usage for circadian criteria, EPRI has recently published results from a lab-based evaluation of illuminance, spectral output, and energy consumption for several LED products marketed for circadian performance. The research presented here contributes to the field by quantifying the performance of market-available technologies through detailed monitoring of performance parameters (such as illuminance, spectral output, glare, and energy consumption) in a physical space (an office environment).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photo-Induced Hydrogen Production from Formic Acid Using a Palladium Catalyst

Liquid organic hydrogen carriers (LOHCs) are recognized as promising sustainable hydrogen (H 2 ) carriers due to their high volumetric capacity and ability to store H 2 at ambient conditions, eliminating the need for energy-intensive liquefaction or compression processes associated with H 2 or ammonia gas. One of the main current drawbacks, however, is LOHCs’ high energy demand for H 2 release. This work presents the photo-induced liberation of H 2 from formic acid (FA) as a liquid H 2 carrier, using visible light and well-established 5 wt% palladium nanoparticles supported over carbon (Pd/C). We show that low-power light-emitting diodes (LEDs) produced higher gas flow than their thermal baseline (35 °C), with 27.2 mL/min and 7.72 mL/min, respectively. Further, the rate of gas evolved with light intensity, catalyst loading, and the concentration of FA. Light-induced dehydrogenation shows similar deactivation as the known thermal mechanisms, such as the decreased Pd 2+ /Pd 0 ratio and Pd nanoparticle agglomeration. Hence, these observations suggest a photothermal mechanism, whereby the LED provides heat efficiently absorbed by the Pd/C catalyst and enhanced by Pd’s ability to absorb light, thereby driving the FA dehydrogenation reaction at ambient conditions.

08 HYDROGEN↗

Efficient Perovskite Solar Cells Achieved via Rapid Photonic Annealing of all Stacking Layers: Unveiling the Crystallization Energy Window

In this study, we report high-performance perovksite solar cells (PSCs) with rapid photonic annealing (RPA) of all stacking layers, enabled by ultraviolet (UV) light-emitting diode (LED) sources, to replace lengthy and energy-intensive thermal annealing (TA). The UV-LED annealing technique allows for layer-specific annealing, where the selected light source provides a precise UV wavelength for maximizing the amount of light absorption by the target layer. The disparity in optical absorption between the target layer and the underlying films allows the stack of the underlying films to remain relatively unaffected, making this process ideal for heating sensitive substrates. Along with a systematic investigation into the layer-specific annealing mechanism of RPA, the results demonstrated that this UV-LED-based photonic annealing of all stacking layers (7 s for perovskite absorber) can produce PSCs with the power conversion efficiency (PCE) of over 23%, the highest reported among optically annealed PSCs. Moreover, the RPA device retains over 80% of the initial PCE over 1000 h under continuous 1 sun illumination at 55 °C and 30%–60% relative humidity (RH), while TA control device drops to 50% of its initial efficiency. Furthermore, these findings represent significant strides toward achieving rapid, cost-effective, and scalable manufacturing of commercial perovskite photovoltaics (PV).

14 SOLAR ENERGY↗

Efficient Energy Funneling in Quasi‐2D Perovskites: From Light Emission to Lasing

Abstract Quasi‐2D Ruddlesden–Popper halide perovskites with a large exciton binding energy, self‐assembled quantum wells, and high quantum yield draw attention for optoelectronic device applications. Thin films of these quasi‐2D perovskites consist of a mixture of domains having different dimensionality, allowing energy funneling from lower‐dimensional nanosheets (high‐bandgap domains) to 3D nanocrystals (low‐bandgap domains). High‐quality quasi‐2D perovskite (PEA) 2 (FA) 3 Pb 4 Br 13 films are fabricated by solution engineering. Grazing‐incidence wide‐angle X‐ray scattering measurements are conducted to study the crystal orientation, and transient absorption spectroscopy measurements are conducted to study the charge‐carrier dynamics. These data show that highly oriented 2D crystal films have a faster energy transfer from the high‐bandgap domains to the low‐bandgap domains (<0.5 ps) compared to the randomly oriented films. High‐performance light‐emitting diodes can be realized with these highly oriented 2D films. Finally, amplified spontaneous emission with a low threshold 4.16 µJ cm −2 is achieved and distributed feedback lasers are also demonstrated. These results show that it is important to control the morphology of the quasi‐2D films to achieve efficient energy transfer, which is a critical requirement for light‐emitting devices.

Lei, Lei↗

Photoelectronic Monitor of Motion Sickness

Instrument includes gallium arsenide light-emitting diode (LED) and silicon phototransistor with infrared filter, all cast in single plastic housing. Housing attached to subject's face with transparent doublesided adhesive tape. LED directs pulses of infrared light to skin, which reflects them to phototransistor. Phototransistor produces signal that is processed by external circuits to yield plot of infrared reflectance with time. External circuits temperature-compensated and respond only to pulsed component of detector output, rejecting those components caused by stray light. Circuits also extract blood-volume pulse amplitude and heart rate.

Oman, C. M.↗

Laser with optically driven Q-switch

An optically driven interactive Q-switch, i.e., a Q-switch that responds to a short pulse of light, for example, from external light-emitting diodes (LEDs) or diode lasers, is provided for producing an output laser pulse from electronic energy stored in a laser medium. Q-switching is thus achieved on demand by electrically pulsing the light source to produce a pulse of light directed onto a Q-switch medium in the laser cavity. Electronic control of the light pulse from the external source will thus provide not only efficient Q-switching frequency but also independent control of output laser pulse width with a fast rise time for each output laser pulse.

Hemmati, Hamid↗

Laser with optically driven Q-switch

An optically driven interactive Q-switch, i.e., a Q-switch that responds to a short pulse of light, for example, from external light-emitting diodes (LED's) or diode lasers, is provided for producing an output laser pulse from electronic energy stored in a laser medium. Q-switching is thus achieved on demand by electrically pulsing the light source to produce a pulse of light directed onto a Q-switch medium in the laser cavity. Electronic control of the light pulse from the external source will thus provide not only efficient Q-switching frequency but also independent control of output laser pulse width with a fast rise time for each output laser pulse.

Hemmati, Hamid↗

Fast-Charging Li 4 Ti 5 O 12 Anode Driven by Light

Lithium-ion batteries with fast charging capabilities are crucial for widespread adoption of electric vehicles, as they will increase acceptance of the technology and reduce range anxiety for drivers. To achieve this, advanced fast charging technologies and alternative methods to enhance the slow electrochemical processes are desperately required. This study applied light-emitting diode (LED) photo-assisted fast charging to Li 4 Ti 5 O 12 (LTO), a large bandgap cubic spinel material, to enhance charging speed through electronic-structure coupling. UV LED-generated light irradiation on to the electrode interface boosted the ion diffusion and lithium cation addition by a factor of 1.3 during electrochemical lithiation, resulting in a 30% decrease in charging time under ambient conditions. Red LED light was not effective in accelerating the reaction as it does not provide sufficient energy. The first-principles calculations support the concept that UV illumination generates charges by overcoming the material’s bandgap and effectively reducing it through the introduction of additional titanium defect states.

25 ENERGY STORAGE↗

An LED Approach for Measuring the Photocatalytic Breakdown of Crystal Violet Dye

A simple technique to assess the reactivity of photocatalytic coatings sprayed onto transmissive glass surfaces was developed. This new method uses ultraviolet (UV) gallium nitride (GaN) light-emitting diodes (LEDs) to drive a photocatalytic reaction (the photocatalytic breakdown of a UV-resistant dye applied to a surface coated with the semiconductor titanium dioxide); and then a combination of a stabilized white light LED and a spectrometer to track the dye degradation as a function of time. Simple, standardized evaluation techniques that assess photocatalytic materials over a variety of environmental conditions, including illumination level, are not generally available and are greatly needed prior to in situ application of photocatalytic technologies. To date, much research pertaining to this aspect of photocatalysis has been limited and has focused primarily on laboratory experiments using mercury lamps. Mercury lamp illumination levels are difficult to control over large ranges and are temporally modulated by line power, limiting their use in helping to understand and predict how photocatalytic materials will behave in natural environmental settings and conditions. The methodology described here, using steady-state LEDs and time series spectroradiometric techniques, is a novel approach to explore the effect of UV light on the photocatalytic degradation of a UV resistant dye (crystal violet). GaN UV LED arrays, centered around 365 nm with an adjustable DC power supply, are used to create a small, spatially uniform light field where the steady state light level can be varied over three to four orders of magnitude. For this study, a set of glass microscope slides was custom coated with a thinly sprayed layer of photocatalytic titanium dioxide. Crystal violet was then applied to these titanium-dioxide coated slides and to uncoated control slides. The slides were then illuminated at various light levels from the dye side of the slide by the UV LED array. To monitor dye degradation on the slides over time, a temperature-stabilized white light LED was used to illuminate the opposite side of the slides. As the dye degraded, the amount of light from the white light LED transmitted through the slide was monitored with a spectrometer and subsequently analyzed to determine and compare the rate of dye degradation for photocatalytically coated versus uncoated slide surfaces. The long-term stability of the spectrometer/white light LED combination, which required only a single reference spectra to be taken for a time series sequence of several hours, enabled accurate measurements of transmitted light over time. Time series transmission curves were generated and results demonstrated that over time the transmission increased much more rapidly on the coated slides than on the control slides. This experimental configuration and methodology for photocatalytic activity measurement minimizes many external variable effects and allows low light level studies to be performed. This study also compares the advantages of this novel LED light source design to traditional mercury lamp systems and non-LED lamp approaches that have conventionally been used. The methodology and experimental design research summarized in this abstract is partly funded by the Department of Homeland Security, Science and Technology Directorate, and by the NASA Stennis Space Center Innovative Partnerships Program.

Ryan, Robert E.↗

Intern Abstract for Spring 2016

The Human Interface Branch - EV3 - is evaluating Organic lighting-emitting diodes (OLEDs) as an upgrade for current displays on future spacecraft. OLEDs have many advantages over current displays. Conventional displays require constant backlighting which draws a lot of power, but with OLEDs they generate light themselves. OLEDs are lighter, and weight is always a concern with space launches. OLEDs also grant greater viewing angles. OLEDs have been in the commercial market for almost ten years now. What is not known is how they will perform in a space-like environment; specifically deep space far away from the Earth's magnetosphere. In this environment, the OLEDs can be expected to experience vacuum and galactic radiation. The intern's responsibility has been to prepare the OLED for a battery of tests. Unfortunately, it will not be ready for testing at the end of the internship. That being said much progress has been made: a) Developed procedures to safely disassemble the tablet. b) Inventoried and identified critical electronic components. c) 3D printed a testing apparatus. d) Wrote software in Python that will test the OLED screen while being radiated. e) Built circuits to restart the tablet and the test pattern, and ensure it doesn't fall asleep during radiation testing. f) Built enclosure that will house all of the electronics Also, the intern has been working on a way to take messages from a simulated Caution and Warnings system, process said messages into packets, send audio packets to a multicast address that audio boxes are listening to, and output spoken audio. Currently, Cautions and Warnings use a tone to alert crew members of a situation, and then crew members have to read through their checklists to determine what the tone means. In urgent situations, EV3 wants to deliver concise and specific alerts to the crew to facilitate any mitigation efforts on their part. Significant progress was made on this project: a) Open channel with the simulated Caution and Warning system to acquire messages. b) Configure audio boxes. c) Grab pre-recorded audio files. d) Packetize the audio stream. A third project that was assigned to implement LED indicator modules for an Omnibus project. The Omnibus project is investigating better ways designing lighting for the interior of spacecraft-both spacecraft lighting and avionics box status lighting indication. The current scheme contains too much of the blue light spectrum that disrupts the sleep cycle. The LED indicator modules are to simulate the indicators running on a spacecraft. Lighting data will be gathered by human factors personal and use in a model underdevelopment to model spacecraft lighting. Significant progress was made on this project: Designed circuit layout a) Tested LEDs at LETF. b) Created GUI for the indicators. c) Created code for the Arduino to run that will illuminate the indicator modules.

Gibson, William↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗