Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light detection and ranging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Bringing weak transitions to light

Abstract Weak transitions between quantum states are of fundamental importance for a broad range of phenomena from analytical biochemistry to precision physics, but generally challenge experimental detection. Due to their small cross sections scaling with the absolute square of their transition matrix elements, spectroscopic measurements often fail in particular in the presence of competing background processes. Here we introduce a general concept to break this scaling law and enhance the transition probability by exploiting a stronger laser-coupled pathway to the same excited state. We demonstrate the concept experimentally by attosecond transient absorption spectroscopy in helium atoms. The quasi-forbidden transitions from the ground state 1s 2 to the weakly coupled doubly excited 2p3dandsp 2,4− states are boosted by an order of magnitude. Enhancing single-photon-suppressed transitions can find widespread applicability, from spectral diagnostics of complex molecules in life and chemical sciences to precision spectroscopy of weak transitions in metastable atomic nuclei in the search for new physics.

Science & Technology - Other Topics↗

Mapping the cosmic gamma-ray horizon: the 1CGH catalogue of Fermi -LAT detections above 10 GeV

ABSTRACT We present the First Cosmic Gamma-ray Horizon (1CGH) catalogue, featuring $\gamma$-ray detections above 10 GeV based on 16 yr of observations with the Fermi Large Area Telescope (Fermi-LAT) satellite. After carefully selecting a sample of blazars and blazar candidates from catalogues in the literature, we performed a binned likelihood analysis and identified 2791 $\gamma$-ray emitters above 10 GeV, at >3$\sigma$ level, including 62 that are new $\gamma$-ray detections. For each source, we estimated the mean energy of the highest energy bin and analysed them in the context of the cosmic gamma-ray horizon. By adopting a reference model for the extragalactic background light (EBL), we identified a subsample of 525 sources where moderate to severe $\gamma$-ray absorption could be detected across the redshift range of 0–3. This work provides the most up-to-date compilation of detections above 10 GeV, along with their redshift information. We condense extensive results from the literature, including reports on observational campaigns dedicated to blazars and $\gamma$-ray sources, thereby delivering an unprecedented review of the redshift information for sources detected above 10 GeV. Additionally, we highlight key 1CGH sources where redshift information remains incomplete, offering guidance for future optical observation campaigns. The 1CGH catalogue aims to track the most significant sources for studying the $\gamma$-ray transparency of the Universe. Furthermore, it provides a targeted subsample where the EBL optical depth, $\tau _{(E,z)}$, can be robustly measured using Fermi-LAT data.

Arsioli, Bruno (ORCID:0000000181666602)↗

A multisensor system for airborne surveillance of oil pollution

The U.S. Coast Guard is developing a prototype airborne oil surveillance system for use in its Marine Environmental Protection Program. The prototype system utilizes an X-band side-looking radar, a 37-GHz imaging microwave radiometer, a multichannel line scanner, and a multispectral low light level system. The system is geared to detecting and mapping oil spills and potential pollution violators anywhere within a 25 nmi range of the aircraft flight track under all but extreme weather conditions. The system provides for false target discrimination and maximum identification of spilled materials. The system also provides an automated detection alarm, as well as a color display to achieve maximum coupling between the sensor data and the equipment operator.

Edgerton, A. T.↗

Limits on an optical pulsar in supernova 1987A

Since March 1987 the optical flux from supernova 1987A for periodic pulsations has been sought. As of August 1988, after 38 separate observations, no pulsar has been detected. The typical upper limit placed on the pulsed fraction optical light from the supernova is 0.0002, for pulse frequencies in the range 0.03-5000 Hz. The best limit on the pulsed fraction of supernova light is 7 x 10 to the -6th, on January 22, 1988. On August 28, 1988 the faintest limit for the magnitude of the pulsar, dimmer than 20th mag is reached. These limits are based on Fourier transforms of up to 67 million points, covering a range of spindown rates.

Pennypacker, C. R.↗

Observations of the Crab pulsar and nebula by the EGRET telescope on the Compton Gamma-Ray Observatory

The Crab pulsar and nebula were observed three times in 1991 April to June by the Energetic Gamma-Ray Experiment Telescope (EGRET) on the Compton Gamma-Ray Observatory (CGRO): April 23 to May 7, May 16 to 30, and June 8 to 15. The results of analysis of the gamma-ray emission in the energy range from 50 MeV to more than 10 GeV are reported. The observed gamma-ray light curve exhibits two peaks separated in phase by 0.40 +/- 0.02, consistent with previous observations. The total pulsed emission from the Crab pulsar is found to be well represented by a power-law spectrum, softer than the spectrum measured by COS B (Clear et al., 1987). The interpulse emission has a harder spectrum than either of the pulses. The evidence for pulsed emission above 5 GeV in the EGRET data is not conclusive. Unpulsed emission in the energy range 50 MeV to 5 GeV was detected, with an indication of a hardening of the unpulsed spectrum above about 1 GeV. There was a significant change in the light curve over the 2 months of these observations, although the shape of the spectrum remained constant.

Nolan, P. L.↗

How silicon and boron dopants govern the cryogenic scintillation properties of N -type GaAs

This work is the first report describing how the concentrations of silicon and boron govern the cryogenic scintillation properties of n-type GaAs. It shows that valence band holes are promptly trapped on radiative centers and then combine radiatively with silicon donor band electrons at rates that increase with the density of free carriers. It also presents the range of silicon and boron concentrations needed for efficient light emission under X-ray excitation, which along with its low band gap and apparent absence of afterglow, make scintillating GaAs suitable for the detection of rare, low-energy electronic excitations from interacting dark matter particles. A total of 29 samples from four different suppliers were studied. Luminosities and timing responses were measured for the four principal emission bands centered at 860, 930, 1070, and 1335 nm, and for the total emissions. Excitation pulses of 40 kVp X-rays were provided by a light-excited X-ray tube driven by an ultra-fast laser. Scintillation emissions from 800 to 1350 nm were measured using an InGaAs photomultiplier. Within the concentration ranges of free carriers from 2 x 10 16 /cm 3 to 6 x 10 17 /cm 3 and boron from 1.5 × 10 18 /cm 3 to 6 x 10 18 /cm 3 , nine samples have luminosities > 70 photons/keV and two have luminosities > 110 photons/keV. Other samples in that range have lower luminosities due to higher concentrations of non-radiative centers. The decay times decrease by typically a factor of ten with increasing free carrier concentrations from 10 17 /cm 3 to 2 x 10 18 /cm 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Miniature Cathode Ray Magnetometer

In this study, we introduce the concept and construction of an innovative Digital Miniature Cathode Ray Magnetometer designed for the precise detection of magnetic fields. This device addresses several limitations inherent to magnetic probes such as D.C. offset, nonlinearity, temperature drift, sensor aging, and the need for frequent recalibration, while capable of operating in a wide range of magnetic fields. The core principle of this device involves the utilization of a charged particle beam as the sensitivity medium. The system leverages the interaction of an electron beam with a scintillator material, which then emits visible light that is captured by an imager. The emitted scintillation light is captured by a CMOS sensor. This sensor not only records the scintillation light but also accurately determines the position of the electron beam, providing invaluable spatial information crucial for magnetic field mapping. The key innovation lies in the combination of electron beam projection, CMOS imager scintillation-based detection, and digital image signal processing. By employing this synergy, the magnetometer achieves remarkable accuracy, sensitivity and dynamic range. The precise position registration enabled by the CMOS sensor further enhances the device’s utility in capturing complex magnetic field patterns, allowing for 2D field mapping. In this work, the optimization of the probe’s performance is tailored for applications related to the characterization of insertion devices in light sources, including undulators.

Turqueti, Marcos↗

Fast, High-Resolution Terahertz Radar Imaging at 25 Meters

We report improvements in the scanning speed and standoff range of an ultra-wide bandwidth terahertz (THz) imaging radar for person-borne concealed object detection. Fast beam scanning of the single-transceiver radar is accomplished by rapidly deflecting a flat, light-weight subreflector in a confocal Gregorian optical geometry. With RF back-end improvements also implemented, the radar imaging rate has increased by a factor of about 30 compared to that achieved previously in a 4 m standoff prototype instrument. In addition, a new 100 cm diameter ellipsoidal aluminum reflector yields beam spot diameters of approximately 1 cm over a 50x50 cm field of view at a range of 25 m, although some aberrations are observed that probably arise from misaligned optics. Through-clothes images of a concealed threat at 25 m range, acquired in 5 seconds, are presented, and the impact of reduced signal-to-noise from an even faster frame rate is analyzed. These results inform the system requirements for eventually achieving sub-second or video-rate THz radar imaging.

standoff concealed weapons detection↗

Extreme ultraviolet spectroscopy and photometry of VV Puppis during a high accretion state

We determine the physical properties of the accretion region of the AM Her-type binary VV Puppis using extreme ultraviolet (EUV) medium-resolution spectroscopy and photometry obtained with the Extreme Ultraviolet Explorer (EUVE) observatory. The EUV continuum from VV Pup was detected in the wavelength range from 75 to 135 A and was simultaneously recorded with the Deep Survey/Spectrometer (DS/S) imaging telescope, allowing for the extraction of an accurate light curve. VV Pup appeared to have entered a high-accretion state just prior to the pointed EUVE observations. We use the EUV light curve to infer the diameter of the accretion region (d = 220 km) assuming a hemispherical geometry and a radius of 9000 km for the white dwarf. We perform a model atmosphere analysis and, based on the light curve properties and assuming a distance of 145 pc, we derive an effective temperature of the accretion region in the range 270,000 is less than T(sub eff) is less than 360,000 K and a neutral hydrogen column density in the local interstellar medium of n(sub H) = 1.9 - 3.7 x 10(exp 19)/sq cm. The total EUV/soft X-ray energy radiated by the accretion region is approximately 3.5 x 10(exp 32) ergs/s. Our results provide a first verification of past suggestions that deep heating of the white dwarf surface produces the soft X-ray flux from the polars. We present a possible detection of O VI absortion features, and we suggest that extensive EUVE observations targeting high-accretion events may result in oxygen and heavier element abundance determination in the accretion region.

Vennes, Stephane↗

Bulk and integrated acousto-optic spectrometers for radio astronomy

The development of sensitive heterodyne receivers (front end) in the centimeter and millimeter range, and the construction of sensitive RF spectrometers (back end) enable the spectral lines of interstellar molecules to be detected and identified. A technique was developed which combines acoustic bending of a collimated coherent light beam by a Bragg cell followed by detection by a sensitive array of photodetectors (thus forming an RF acousto-optic spectrometer (AOS). An AOS has wide bandwidth, large number of channels, and high resolution, and is compact, lightweight, and energy efficient. The thrust of receiver development is towards high frequency heterodyne systems, particularly in the millimeter, submillimeter, far infrared, and 10 micron spectral ranges.

Chin, G.↗

The Flux of Large Meteoroids Observed with Lunar Impact Monitoring

The flux of large meteoroids is not well determined due to relatively low number statistics, due mainly to the lack of collecting area available to meteor camera systems (10(2)-10(5) km2). Larger collecting areas are needed to provide reasonable statistics for flux calculations. The Moon, with millions of square kilometers of lunar surface, can be used as a detector for observing the population of large meteoroids in the tens of grams to kilogram mass range. This is accomplished by observing the flash of light produced when a meteoroid impacts the lunar surface, converting a portion of its kinetic energy to visible light detectable from Earth. A routine monitoring program at NASA's Marshall Space Flight Center has recorded over 300 impact flashes since early 2006. The program utilizes multiple 0.35 m (14 inch) Schmidt-Cassegrain telescopes, outfitted with video cameras using the 1/2 inch Sony EXview HAD CCDTM chip, to perform simultaneous observations of the earthshine hemisphere of the Moon when the lunar phase is between 0.1 and 0.5. This optical arrangement permits monitoring of approximately 3.8x10(6) km2 of lunar surface. A selection of 126 flashes recorded in 266.88 hours of photometric skies was analyzed, creating the largest and most homogeneous dataset of lunar impact flashes to date. Standard CCD photometric techniques outlined in [1] were applied to the video to determine the luminous energy, kinetic energy, and mass for each impactor, considering a range of luminous efficiencies. The flux to a limiting energy of 2.5x10(-6) kT TNT or 1.05×10(7) J is 1.03×10(-7) km(-2) hr(-1) and the flux to a limiting mass of 30 g is 6.14×10(-10) m(-2) yr(-1). Comparisons made with measurements and models of the meteoroid population indicate that the flux of objects in this size range is slightly lower (but within the error bars) than the power law distribution determined for the near Earth object population by [2].

Cooke, W. J.↗

GLAST: Exploring Nature's Highest Energy Processes with the Gamma-ray Large Area Space Telescope

The Gamma-ray Large Area Space Telescope (GLAST) is an international and multi-agency space mission that will study the cosmos in the energy range 10 keV-300 GeV. Several successful exploratory missions in gamma-ray astronomy led to the Energetic Gamma Ray Experiment Telescope (EGRET) instrument on the Compton Gamma Ray Observatory (CGRO). Launched in 1991, EGRET made the first complete survey of the sky in the 30 MeV-10 GeV range. EGRET showed the high-energy gamma-ray sky to be surprisingly dynamic and diverse, with sources ranging from the sun and moon to massive black holes at large redshifts. Most of the gamma-ray sources detected by EGRET remain unidentified. In light of the discoveries with EGRET, the great potential of the next generation gamma-ray telescope can be appreciated. GLAST will have an imaging gamma-ray telescope vastly more capable than instruments flown previously, as well as a secondary instrument to augment the study of gamma-ray bursts. The main instrument, the Large Area Telescope (LAT), will have superior area, angular resolution, field of view, and deadtime that together will provide a factor of 30 or more advance in sensitivity, as well as provide capability for study of transient phenomena. The GLAST Burst Monitor (GBM) will have a field of view several times larger than the LAT and will provide spectral coverage of gamma-ray bursts that extends from the lower limit of the LAT down to 10 keV. The basic parameters of the GBM are compared to those of the Burst and Transient Source Experiment (BATSE) instrument on CGRO in Table 1-2. With the LAT and GBM, GLAST will be a flexible observatory for investigating the great range of astrophysical phenomena best studied in high-energy gamma rays. NASA plans to launch GLAST in late 2005.

Digel, Seth↗

Particulate contamination spectrometer. Volume 1: Technical report

A laser particulate spectrometer (LPS) system was developed to measure the size and speed distributions of particulate (dusts, aerosols, ice particles, etc.) contaminants. Detection of the particulates was achieved by means of light scattering and extinction effects using a single laser beam to cover a size range of 0.8 to 275 microns diameter and a speed range of 0.2 to 20 meter/second. The LPS system was designed to operate in the high vacuum environment of a space simulation chamber with cold shroud temperatures ranging from 77 to 300 K.

Schmitt, R. J.↗

A laser particulate spectrometer for a space simulation facility

A laser particulate spectrometer (LPS) system was developed to measure the size and speed distributions of particulate contaminants. Detection of the particulates is achieved by means of light scattering and extinction effects using a single laser beam to cover a size range of 0.8 to 275 microns diameter and a speed range of 0.2 to 20 meters/second. The LPS system was designed to operate in the high-vacuum environment of a space simulation chamber with cold shroud temperatures ranging from 77 to 300 K.

Schmitt, R. J.↗

Application of X-Ray Pulsar Navigation: A Characterization of the Earth Orbit Trade Space

The potential for pulsars as a navigation source has been studied since their discovery in 1967. X-ray pulsar navigation (XNAV) is a celestial navigation system that uses the consistent timing nature of x-ray photons from millisecond pulsars (MSP) to perform space navigation. By comparing the detected arrival of x-ray photons to a reference database of expected pulsar light-curve timing models, one can infer a range and range rate measurement based on light time delay. Much of the challenge of XNAV comes from the faint signal, availability, and distant nature of pulsars. This is a study of potential pulsar XNAV measurements to measure extended Kalman filter (EKF) tracking performance with a wide trade space of bounded Earth orbits, using a simulation of existing x-ray detector space hardware. An example of an x-ray detector for XNAV is the NASA Station Explorer for X-ray Timing and Navigation (SEXTANT) mission, a technology demonstration of XNAV set to perform on the International Space Station (ISS) in late 2016early 2017. XNAV hardware implementation is driven by trajectory and environmental influences which add noise to the x-ray pulse signal. In a closed Earth orbit, the radiation environment can exponentially increase the signal noise from x-ray pulsar sources, decreasing the quality and frequency of measurements. The SEXTANT mission in particular improves on the signal to noise ratio by focusing an array of 56 x-ray silicon drift detectors at one pulsar target at a time. This reduces timing glitches and other timing noise contributions from ambient x-ray sources to within a 100 nanosecond resolution. This study also considers the SEXTANT scheduling challenges inherent in a single target observation. Finally, as the navigation sources are now relatively inertial targets, XNAV measurements are also subject to periods of occultation from various celestial bodies. This study focuses on the characterization of these drivers in closed Earth orbits and is not a tuning analysis of the EKF. The study shows that the closed Earth orbit for XNAV performance is reliant on the orbit semi-major axis and eccentricity as well as orbit inclination. These parameters are the primary drivers of pulsar measurement availability and significantly influence the natural spacecraft orbit dynamics. Sensitivity to initial orbit determination error growth due to the scarcity of XNAV measurements within an orbital period require appropriate timing of initial XNAV measurements. The orbit angles of argument of perigee and right ascension of the ascending node, alongside the other orbit parameters, complete the initial cadence of XNAV measurements. The performance of initial XNAV measurements then propagates throughout the experimental period. The study provides a basis to missions who wish to consider XNAV as a potential navigation source in a closed Earth orbit design. It provides a family of orbit trajectories as well as other modeling considerations needed to effectively evaluate if XNAV is an effective navigation source for a potential mission. As an EKF is sensitive to a linearized estimated state, this study has a direct benefit of providing effective XNAV measurements to maintain spacecraft tracking, independent of other navigation sources. In the particular use case of the SEXTANT mission, it also provides a novel scheduling algorithm which addresses the need to prioritize and manage pulsar observations for effective navigation.

x-ray↗

New measurements of the far ultraviolet scattering properties of interstellar dust

An analysis is presented for the spectra of the diffuse ultraviolet background taken during shuttle flight STS-61C (January 1986). Eight regions of the sky were observed for approximately 20 minutes each, using a spectrograph designed specifically to perform measurements of the UV background. The field of view was 3.8 deg x 8 min, with imaging along the slit to confine stellar contamination. The instrument featured a shutter mechanism to measure internal background during flight, a low-scatter holographically ruled diffraction grating, photon counting microchannel plate detectors, through baffling, and a crystal window to further attenuate stray light. The spectra covered the range 1400 to 1850 A and was binned in 50 A bands. The procedure for substracting the contribution of stars too faint to be detected as discrete sources during the observations (in general this represents a small fraction of the total intensity detected except at the longest wavelengths). A radiative transfer model used to interpret the data and set confidence intervals on the relevant parameters is described. It was found that the continuum component of the diffuse ultraviolet background arises primarily from two sources. One source is scattering of starlight by interstellar dust with an albedo of about 12 percent and a relatively isotropic phase function. A second source consists of about 150 photons/cm/sec/ster/A of extragalactic light which is attenuated by the dust in the galaxy. Although emission features possibly associated with molecular H2 are detected in one look direction, fluorescence of H2 is not a major contributor to the diffuse UV background, at least at galactic latitudes greater than -10 degrees.

Hurwitz, Mark↗

Signatures of particle acceleration at SN 1987A

At least eight experiments are currently monitoring SN 1987A for photons or neutrinos with energies in the TeV range or higher. Observation of such signals would indicate that the supernova is the site of acceleration of charged particles to even higher energies. The way that the acceleration might occur is discussed, and the prospects for detection of such signals in light of current limits on power in the supernova from sources other than the nickel-cobalt-iron decay chain are evaluated. It is pointed out that signals of particle acceleration may show up in continuum MeV gamma rays as well as in the 100 MeV range.

Gaisser, T. K.↗

A sensitive time-resolved radiation pyrometer for shock-temperature measurements above 1500 K

The general design, calibration, and performance of a new high-sensitivity radiation pyrometer are described. The pyrometer can determine time-resolved temperatures (as low as 1500 K) in shocked materials by measuring the spectral radiance of light emitted from shocked solid samples in the visible and near-infrared wavelength range (0.5-1.0 micron). The high sensitivity of the radiation pyrometer is attributed to the large angular aperture (0.06 sr), the large bandwidth per channel (up to 0.1 micron), the large photodiode detection areas (1.0 sq cm), and the small number of calibrated channels (4) among which light is divided.

Boslough, Mark B.↗