Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Analytical Functions for 200 West Pump-and-Treat SCADA Sensor Data

Historical operations at the U.S. Department of Energy’s Hanford Site included disposal of waste fluids to the subsurface in the 200 West Area on the Hanford Central Plateau. Subsequent infiltration of fluids has resulted in groundwater contamination with carbon tetrachloride, nitrate, uranium, technetium-99, and other contaminants. A pump-and-treat (P&T) system, with an extraction/injection well network and an aboveground treatment plant, was implemented as part of interim and final remedies in the 200 West area. The HYPATIA single-page web application (part of the SOCRATES suite) is being developed to provide access to and analysis of chemistry and treatment facility sensor data for this 200 West P&T system. For the web application, analytical algorithms were developed to perform summing, differencing, smoothing, outlier detection, change-point detection, mass flow rate, and injectivity calculations on the data. Candidate algorithms were identified and tested, with the best-performing algorithms then assembled for implementation in HYPATIA. Because HYPATIA is hosted on the Amazon Web Services (AWS) cloud computing platform, algorithms were implemented in a back-end AWS Lambda function that can be called by the HYPATIA front end. The Lambda function applies the requested data processing to specified data via functions written in R, Python, and JavaScript. Development, testing, and review of the data analysis algorithms was completed under an NQA-1 quality program. This new HYPATIA functionality will provide information to support site decisions regarding P&T system performance and optimization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CO 2 -Responsive Fracturing Fluids for Enhanced Geothermal Systems (Final Report)

Our group has recently developed StimuFrac, a non-toxic stimuli-responsive fracturing fluid consisting of a CO 2 -reactive polymer which has shown at the lab-scale to consistently fracture rock cores at significantly lower net pressures in a range of representative geothermal pressure/temperature conditions. However, until now the mechanism/s responsible for more effective fracturing, of critical importance to optimize fracturing performance as well as strategize injection methodologies for field deployment, was not understood. In this document, we report (1) on the two main mechanisms responsible for fracturing rock at lower net pressures with StimuFrac; (2) the phase behavior of StimuFrac/CO 2 under geothermal wellbore conditions; and (3) based on high-temperature true triaxial stimulations, detailed evidence that StimuFrac/CO 2 is the best performing stimulation fluid under EGS T/P conditions as compared to water, waterless CO 2 , and CO 2 /water fracturing fluids. This is because i) it requires significantly lower volumes of CO 2 due to its reduced leak off into the formation by the crosslinked polymer solution; ii) large fractures can be generated reproducibly at both low and high CO 2 injection flow rates, and iii) the reversible (previously reported) viscosity increase of StimuFrac could be beneficial to transport proppants when they become available for EGS. These results were particularly evident for hot nearly dry rock as well as partially and nearly fully water-saturated granitic rock. GTO requires StimuFrac to be evaluated in fully water-saturated rock to determine whether the above-described performance applies under these conditions. Since (1) GTO considers there is no enough evidence for Sa different StimuFrac formulation to work below 90C (where full water-saturation in an open system is possible) and (2) no polyaxial loading frame larger than a few centimeters that can do hydraulic fracturing tests while maintaining the rock sample fully saturated with water at 200 C exists; PNNL concludes that the only way to determine if StimuFrac represents an advanced fracturing fluid alternative for EGS, is to perform a stimulation in an actual EGS reservoir.

15 GEOTHERMAL ENERGY↗

Warm gas TVC design study

A warm gas thrust vector control system was studied to optimize the injection geometry for a specific engine configuration, and an injection valve was designed capable of meeting the base line requirements. To optimize injection geometry, studies were made to determine the performance effects of varying injection location, angle, port size, and port configuration. Having minimized the injection flow rate required, a warm gas valve was designed to handle the required flow. A direct drive hydraulic servovalve capable of operating with highly contaminated hydraulic fluid was designed. The valve is sized to flow 15 gpm at 3000 psia and the direct drive feature is capable of applying a spool force of 200 pounds. The baseline requirements are the development of 6 deg of thrust vector control utilizing 2000 F (total temperature) gas for 180 seconds on a 1.37 million pound thrust engine burning LOX and RP-1 at a chamber pressure of 250 psia with a 155 inch long conical nozzle having a 68 inch diameter throat and a 153 inch diameter exit.

Moorhead, S. B., Jr.↗

Experimental study of forward-located jet-interaction nozzles

The effects of forward-mounted sonic jet-interaction nozzles with one, three equal, or one large and two small orifices on the transitional or turbulent boundary-layer flow over a biconic (9-deg-25-arcmin/6-deg) model at angle of attack -10 to the 15 deg and Reynolds number 8.10 x 10 to the 6th/ft are investigated experimentally using pressure taps, force measurements, oil-flow visualization, and schlieren photography in the 20-in. Mach-6 wind tunel at NASA Langley. The injection flow rates are 0.055 and 0.026 lbm/s, with stagnation pressure 500 psia, stagnation temperature 1000 R, and dynamic pressure 8.7 psia. The results are presented in diagrams, graphs, and photographs and characterized. Moment amplification factors of 1.0 or better (maximum 1.8 at angle of attack 15 deg and flow rate 0.055 lbm/s) are observed for all nozzle types, but the configuration with three unequal orifices is found to give improvements of 10 percent over the single-orifice nozzle at a given flow rate.

Cavalleri, R. J.↗

Investigation of the Discharge Rate of a Fuel-injection System

In connection with the development of a method for analyzing indicator cards taken from high-speed compression-ignition engines, this investigation was undertaken to determine the average quantity of fuel discharged during each crank degree of injection period.

Gerrish, Harold C↗

Computational Study of Fluidic Thrust Vectoring using Separation Control in a Nozzle

A computational investigation of a two- dimensional nozzle was completed to assess the use of fluidic injection to manipulate flow separation and cause thrust vectoring of the primary jet thrust. The nozzle was designed with a recessed cavity to enhance the throat shifting method of fluidic thrust vectoring. The structured-grid, computational fluid dynamics code PAB3D was used to guide the design and analyze over 60 configurations. Nozzle design variables included cavity convergence angle, cavity length, fluidic injection angle, upstream minimum height, aft deck angle, and aft deck shape. All simulations were computed with a static freestream Mach number of 0.05. a nozzle pressure ratio of 3.858, and a fluidic injection flow rate equal to 6 percent of the primary flow rate. Results indicate that the recessed cavity enhances the throat shifting method of fluidic thrust vectoring and allows for greater thrust-vector angles without compromising thrust efficiency.

Deere, Karen↗

Numerical Prediction of Heat Transfer Coefficients during Xenon Tank Fill in Microgravity

NASA’s Gateway will serve as an orbital outpost to enable sustained human lunar exploration and facilitate access to destinations beyond the Moon. To maintain sustainable deep space missions, on-orbit propellant transfer and refueling must be realized. One of Gateway’s critical components, the Power and Propulsion Element (PPE), will use solar electric propulsion to perform attitude control maneuvers and orbit transfers. Xenon will be used as the propellant for the PPE and stored in a composite overwrapped pressure vessel (COPV). During the propellant refueling process, xenon will compress causing the fluid and tank walls to warm. There is concern that the bond between the tank liner and composite may degrade at elevated temperatures, along with the possibility of the tank exceeding design pressure. While on-orbit testing is being proposed, numerical models are being used to predict the thermal response and reduce risk during a refueling operation in microgravity where natural convection is diminished. Accurate numerical models may be used to inform decisions for follow-on testing, or design and operation of refueling architectures. Challenges of modeling xenon tank fill in microgravity include non-ideal gas behavior, operating near the fluid’s critical point, and lack of experimental flight data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict averaged heat transfer coefficients during tank filling. At the anticipated injection flow rates, the CFD results showed that forced convection dominates in microgravity. Initial results from a multi-node Thermal Desktop model that assumed a purely conducting fluid (Nu=1) over-predicted the CFD fluid temperature and pressure, while a similar model allowing for natural convection under-predicted. The heat transfer coefficients predicted by CFD were implemented into the multi-node model, and the COPV thermal response from the two computational approaches were compared with good agreement.

Heat Transfer↗

EGS Reservoir Modeling for Developing Geothermal District Heating at Cornell University: Preprint

Cornell University is pursuing development of an enhanced geothermal system (EGS) for providing heating to its main campus in Upstate New York. A ~10,000 ft (~3 km) deep vertical observation well ("CUBO") was drilled in 2022 to characterize the subsurface using wellbore logging, borehole imaging, fluid sampling, mini-frac tests, coring and drill cutting analysis. Down-hole temperatures measured at 3 km depth are about 80 degrees C, sufficiently high for direct-use heating. The well drilled through generally low porosity and low permeability Paleozoic sedimentary formations and into metamorphic basement rock, encountered at about 9,400 ft depth. Leveraging subsurface data obtained through CUBO, we investigated technical feasibility and design requirements of a doublet well system with horizontal laterals connected to a fracture network created through hydraulic fracturing. The EGS reservoir is sized to provide a nominal heat output in the range 5 to 10 MWth of continuous heating over a 15 year-lifetime with limited thermal drawdown. We applied the Gringarten Multiple parallel fracture model, the Cornell Discrete Fracture Simulator FOXFEM and the commercial simulator ResFrac to estimate required heat transfer area and design a potential hydraulic stimulation treatment. Reservoir simulations indicate that, depending on fluid flow rate and injection temperature, 2 to 3 km2 of effective fracture heat transfer area is required to supply the target heat output of 5 to 10 MWth over 15 years.

district heating↗

EGS Reservoir Modeling for Developing Geothermal District Heating at Cornell University

Cornell University is pursuing development of an enhanced geothermal system (EGS) for providing heating to its main campus in Upstate New York. A ~10,000 ft (~3 km) deep vertical observation well ('CUBO') was drilled in 2022 to characterize the subsurface using wellbore logging, borehole imaging, fluid sampling, mini-frac tests, coring and drill cutting analysis. Down-hole temperatures measured at 3 km depth are about 80 degrees C, sufficiently high for direct-use heating. The well drilled through generally low porosity and low permeability Paleozoic sedimentary formations and into metamorphic basement rock, encountered at about 9,400 ft depth. Leveraging subsurface data obtained through CUBO, we investigated technical feasibility and design requirements of a doublet well system with horizontal laterals connected to a fracture network created through hydraulic fracturing. The EGS reservoir is sized to provide a nominal heat output in the range 5 to 10 MWth of continuous heating over a 15 year-lifetime with limited thermal drawdown. We applied the Gringarten Multiple parallel fracture model, the Cornell Discrete Fracture Simulator FOXFEM and the commercial simulator ResFrac to estimate required heat transfer area and design a potential hydraulic stimulation treatment. Reservoir simulations indicate that, depending on fluid flow rate and injection temperature, 2 to 3 km2 of effective fracture heat transfer area is required to supply the target heat output of 5 to 10 MWth over 15 years.

district heating↗

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Stimulation Program Report - May 2024

This dataset consists of a comprehensive report documenting the stimulation program conducted in May 2024 on Utah FORGE wells 16A(78)-32 and 16B(78)-32. It includes detailed accounts of operational and scientific objectives, stimulation methodologies, and testing outcomes. The report describes the hydraulic fracturing activities, equipment setups, proppant and fluid usage, and the execution of a nine-hour circulation test. It also includes observations from seismic and fiber optic monitoring systems, providing data on microseismic activity and fracture propagation. Detailed parameters for each stimulation stage are provided, alongside operational challenges and solutions. The dataset includes analyses of injection and production rates, well temperatures, and pressure data, supported by graphical illustrations and logs.

15 GEOTHERMAL ENERGY↗

Recent Thermal and Hydraulic Stimulation Results at Raft River, ID EGS Site

The Raft River geothermal system, located 160 km northwest of Salt Lake City, Utah is the site of a Department of Energy Enhanced Geothermal System (EGS) stimulation demonstration project. The target well RRG-9 ST-1, is roughly 1.6 km (1 mile) south of the power plant. This well has undergone a series of thermal and hydraulic stimulation treatments. Furthermore, the well passes through approximately 1,524 m MD (5,000 ft. MD) of laterally discontinuous Quaternary and Tertiary volcanoclastic and volcanic rocks that unconformably overlie the Precambrian basement. The Elba Quartzite formation located in the Precambrian basement is the target zone for the stimulation program. Fluid injected into the well exits through a fracture zone in the Elba Quartzite at 1,567 m TVD (5,140 ft. TVD). In June 2013 low-rate stimulation began at RRG-9 ST-1 using injection water from the geothermal plant. The average injection rate, temperature, and well head pressure of the low-rate stimulation was 163 Lpm (43 gpm), 34°C, and 1,931kPa (280 psig), respectively. This injection continued through late August of 2013 when wellhead pressures were intentionally increased to approximately 5,516 kPa (800 psig) at approximately 984 Lpm (260 gpm). From September 12 to September 24, 2013 cold well water was injected. The average surface injection temperature was approximately 12°C. On September 25, 2013 injection of the warmer plant water was resumed. This was continued through the rest of 2013 and into 2014. Between April 1, 2014 and April 4, 2014, a higher rate hydraulic stimulation was conducted. Colder water (~10°C) was injected at rates of 20 bpm to 30 bpm (3,178 Lpm to 4,770 Lpm) at wellhead pressures of 5,861 kPa (850 psig) over approximately 24 hours. Microseismic activity was recorded near the Tertiary-Precambrian contact. Subsequently, injection of water from the plant was resumed. As of mid-January, 2015, over 666 million liters (176 million gallons) have been injected into the well. The fate of this water is the subject of ongoing numerical analyses and continuous site monitoring. Various analyses have been implemented to monitor and assess the ongoing stimulation program. Modified Hall plot analysis shows increasing conductivity and/or a decreasing skin factor around the wellbore. Since April, 2014, the injectivity index has increased significantly from 0.28 Lpm/kPa (0.5 gpm/psig) to 0.93 Lpm/kPa (1.7 gpm/psig).

enhanced geothermal system↗

Alternative, Less Water-Intensive, Fracturing Fluids for Enhanced Geothermal Systems

Four fracturing fluids; water, CO2, CO2 with water, and CO2 with an aqueous solution of a CO2-reactive polymer, poly(allylamine) (PAA, 1wt%) were evaluated using a high-temperature true-triaxial fracturing apparatus and ½ foot side granite cubic samples. All three CO2-based fracturing fluids, CO2, CO2 with water, and CO2 with aqueous PAA fractured granite at higher breakdown pressures, high transient flow rates, and produce higher-conductivity fractures as compared to water. Additionally, faster pressurization rates with CO2-based fracturing fluids (obtained when fracturing at constant flow rate mode) are found to be associated with higher fracture conductivities. When partially saturating the rock sample with PAA solution followed by fracturing with CO2, the volume expansion caused by CO2-induced cross-linking of PAA leads to a faster pressure increase due to the associated stress generated and increase in viscosity. It was also found that CO2 as a fracturing fluid injected in hot dry rock (HDR) attain the highest fracture conductivity only when injected at very high flow rates, followed very closely by the CO2/PAA fracturing fluid system that generates fractures with, on average, similarly high conductivity values though independently of injection flow rate and using 1/6 of the mass of CO2 as compared to CO2 in HDR. Breakdown pressures were also similar for CO2 stimulation in HDR and CO2/PAA fluid system under identical injection flow rates. It is concluded that CO2 (when injected in HDR) and CO2/PAA are the fluids of choice for stimulation of granitic rock samples under the studied geothermal P/T conditions. CO2/PAA, however, offer the following three additional advantages; 1) it requires significantly lower volumes of CO2, 2) fracture permeability is independent of injection flow rate, and 3) the reversible (previously reported) viscosity increase is beneficial to transport proppants if they are ever developed enhanced geothermal systems.

Jian, Guoqing↗

Southeast Regional CO 2 Utilization and Storage Acceleration Partnership (SECARB-USA): Data Quality Methodology (4.2.1)

SECARB-USA Deliverable 4.2.1 utilizes the outputs from the Needs Assessment (Subtask 2.1) to develop a data quality methodology. Many types of data are needed to evaluate a site for technical and financial viability. Several inventories of data types have been produced (for example NETL, 2010). The objective here is to organize the data types so that the needs met are specified. From this cross index (Table 1 in the Appendix), it will be possible in future tasks to (1) determine, on a site-specific basis, how much of each data type is required at each stage of a project to meet the need, and conversely (2) to further specify and define the data collection methods applied such that the data are tailored to fit that need. Derivative tables can then be developed to semi-quantitively evaluate the extent to which need is critical for early go/no decision points, or if it is more important than average, requiring faster or larger capitalization and spend to meet the need. In an additional step, the current availability of data for a site can be semi-quantitively assessed. From the table of data criticality and the table of data availability, site-specific cost for meeting the data needs can be determined, and allow a pre-permit spend estimated for a portfolio of projects. All of the data needs to evaluate a site are somewhat interconnected. We used criterion (2) above to determine if the data collection design would have to be modified to meet the need; if this was commonly true a linkage was shown. The application of this cross index to sites in the subsequent tasks will demonstrate that the demand for data types varies site-to-site and project-to-project. Examples of factors to be considered are the complexity of the geology, the injection goals such as rate and duration of the injection, and the types of risk and risk tolerance of key stakeholders. In future tasks the team will compare the demand for data with existing data availability. This will, in turn, determine when data needs to be acquired to support project development. For example, in a project area with complex structure, 3-D seismic data may be needed earlier and more urgently than in an area with simple rock body geometries. In some locations, a 3-D seismic survey has already been collected and can be purchased. In other locations the project developer will need to collect these data. For another example, a project near an urban area or near to a park may generate earlier and more substantive public concern than a site that is developed in mined lands. A calculation using the derivative from table 1 will show the different investment needs. Project cost will vary corresponding to data criticality and data availability.

42 ENGINEERING↗

Forecasting induced seismicity in Oklahoma using machine learning methods

Oklahoma earthquakes in the past decade have been mostly associated with wastewater injection. Here we use a machine learning technique—the Random Forest to forecast induced seismicity rate in Oklahoma based on injection-related parameters. We split the data into training (2011.01–2015.05) and test (2015.06–2020.12) periods. The model forecasts seismicity rate during the test period based on input features, including operational parameters (injection rate and pressure), geological information (depth to basement), and modeled pore pressure and poroelastic stress. The results show overall good match with observed seismicity rate (adjusted R 2 of 0.75). The model shows that pore pressure rate and poroelastic stressing rates are the two most important features in forecasting. The absolute values of pore pressure and poroelastic stress, and the injection rate itself, are less important than the stressing rates. These findings further emphasize that temporal changes of stressing rates would lead to significant changes in seismicity rates.

58 GEOSCIENCES↗

Effect of mass-addition distribution and injectant on heat transfer and transition criteria.

Surface pressures, heat-transfer rates, and transition locations for a sharp cone (whose semivertex angle is 12 deg) were obtained in a hypervelocity wind tunnel at a free-stream Mach number of 12 and a free-stream Re/ft range of 3,000,000 to 6,000,000. The effects of injecting either methane, nitrogen, or Freon-22 (at rates up to 2.1% of free-stream rate) were studied for a uniform injection-distribution and for a variable injection-distribution. Gaseous injection had little effect on the surface pressure measurements. For a given mass injection distribution, the laminar region heat-transfer decreases as the injection rate increases or as the molecular weight of the injectant decreases. For a given mass-injection rate (integrated over the surface of the entire cone), the transition location and heat-transfer rates were sensitive to the injection distribution. The transition Reynolds numbers were significantly greater when the local injection rate was constant over the surface of the cone.

Bertin, J. J.↗

Effects of Jet Swirl on Mixing of a Light Gas Jet in a Supersonic Airstream

A non reacting experiment was performed to investigate the effects of jet swirl on mixing of a light gas jet in a supersonic airstream. The experiment consisted of two parts. The first part was an investigation of the effects of jet swirl and skew on the mixing and penetration of a 25 deg. supersonic jet injected from a flat surface (flush wall injection) into a supersonic ducted airflow. Specifically, the objective was to determine whether the jet would mix more rapidly if the jet were swirling, and whether swirl, with and without skew, causes the injectant-air plume to have a net circulation (i.e., a single or dominant vortex). The second part was a preliminary study of the mixing of swirling jets injected from the base of a skewed ramp. The hypothesis was that favorable interactions between vorticity generated by the swirling jet and vortices generated by the ramp could produce mixing enhancements. Both parts of the experiment were conducted at equal injectant mass flow rate and total pressure. The results for the flush wall injection cases indicate that, except relatively close to the injection point, swirl, with or without skew, does not enhance the mixing of the jet, and can in fact reduce penetration. In addition, a plume with significant net circulation is not generated, as had previously been believed. The results for the ramp cases indicated no improvements in mixing in comparison with the baseline (swept ramp injector) case. However, it was not possible to determine the vorticity mechanisms underlying the poor performance, since no measurements of vorticity were made. Thus, since many geometric parameters were chosen arbitrarily, the results are inconclusive for this class of injector.

Doerner, Steven E.↗

Effect of LN2 injection station location on the drive fan power and LN2 requirements of a cryogenic wind tunnel

A theoretical analysis comparing the fan power and coolant (LN2) flow rates resulting from injection of the LN2 either upstream or downstream of the drive fan of a closed circuit transonic cryogenic tunnel is presented. The analysis is restricted to steady state tunnel operation and to the condition that the tunnel walls are adiabatic. The stagnation pressure and temperature range of the tunnel is from 1.0 to 8.8 atm and from 300 K to liquefaction temperature, respectively. Calculations are made using real gas properties of nitrogen. Results show that the fan power and LN2 flow rates are lower if the LN2 is injected upstream of the fan. The lower fan inlet temperature resulting from injecting upstream of the fan has a greater influence on the power than does the additional mass flow going through the fan.

Adcock, J. B.↗

Effects of Gravity on Supercritical Water Oxidation (SCWO) Processes

The effects of gravity on the fluid mechanics of supercritical water jets are being studied at NASA to develop a better understanding of flow behaviors for purposes of advancing supercritical water oxidation (SCWO) technologies for applications in reduced gravity environments. These studies provide guidance for the development of future SCWO experiments in new experimental platforms that will extend the current operational range of the DECLIC (Device for the Study of Critical Liquids and Crystallization) Facility on board the International Space Station (ISS). The hydrodynamics of supercritical fluid jets is one of the basic unit processes of a SCWO reactor. These hydrodynamics are often complicated by significant changes in the thermo-physical properties that govern flow behavior (e.g., viscosity, thermal conductivity, specific heat, compressibility, etc), particularly when fluids transition from sub-critical to supercritical conditions. Experiments were conducted in a 150 ml reactor cell under constant pressure with water injections at various flow rates. Flow configurations included supercritical jets injected into either sub-critical or supercritical water. Profound gravitational influences were observed, particularly in the transition to turbulence, for the flow conditions under study. These results will be presented and the parameters of the flow that control jet behavior will be examined and discussed.

aqueous solutions↗