Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Experimental Determination of Ultra-Sharp Stray Field Distribution from a Magnetic Vortex Core Structure

The fine magnetic stray field from a vortex structure of micron-sized permalloy (Ni{sub 80}Fe{sub 20}) elements has been studied by high-resolution magnetic force microscopy. By systematically studying the width of the stray field gradient distribution at different tip-to-sample distances, we show that the half-width at half-maximum (HWHM) of the signal from vortex core can be as narrow as {approx}21 nm at a closest tip-to-sample distance of 23 nm, even including the convolution effect of the finite size of the magnetic tip. A weak circular reverse component is found around the center of the magnetic vortex in the measured magnetic force microscope (MFM) signals, which can be attributed to the reverse magnetization around the vortex core. Successive micromagnetic and MFM imaging simulations show good agreements with our experimental results on the width of the stray field distribution.

36 MATERIALS SCIENCE↗

Unfolding Structure Formation in the Dark Universe via Weak Gravitational Lensing: from Pixels to Cosmology in the Dark Energy Survey and Roman Space Telescope

Weak gravitational lensing (deflection of light from distant galaxies due to the gravitational potential of intervening mass) is one of the most exciting probes in cosmology as it is sensitive both to the growth of the large-scale structure and the expansion history of the Universe. We can measure the coherent distortion of galaxy shapes (which we call cosmic shear) and infer the matter distribution. With next-generation imaging surveys such as the Vera C. Rubin Observatory Legacy Survey of Space and Time (Rubin LSST) and the Nancy G. Roman Space Telescope (Roman), there is immense new promise in understanding the fundamental nature of dark matter and dark energy. With datasets from current experiments like the Dark Energy Survey (DES), we see apparent cosmological tensions between experiments that may either be real and indicate new physics or new systematics we do not yet understand. LSST and Roman will increase the number of galaxies we have observed by an order of magnitude, leading to improved constraints on our cosmological model by up to 300%. These experiments will have the potential to prove if these cosmological tensions are real. However, our control of systematic uncertainties must also improve by similar levels to achieve the promise of what these missions can deliver. To achieve these scientific outcomes, the challenges of determining galaxy shapes and redshifts and modeling the impact of astrophysical effects must be solved. My PhD has focused on enabling weak lensing science in DES and Roman. I co-led the shear analysis teams in DES to produce the largest weak lensing galaxy sample, as well as the final DES cosmological analysis of cosmic shear. For Roman, I have led two papers characterizing and mitigating shear-related systematics with image simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Energy Survey Year 6 Results: Redshift Calibration of the Weak Lensing Source Galaxies

Determining the distribution of redshifts for galaxies in wide-field photometric surveys is essential for robust cosmological studies of weak gravitational lensing. We present the methodology, calibrated redshift distributions, and uncertainties of the final Dark Energy Survey Year 6 (Y6) weak lensing galaxy data, divided into four redshift bins centered at $\langle z \rangle = [0.414, 0.538, 0.846, 1.157]$. We combine independent information from two methods on the full shape of redshift distributions: optical and near-infrared photometry within an improved Self-Organizing Map $p(z)$ (SOMPZ) framework, and cross-correlations with spectroscopic galaxy clustering measurements (WZ), which we demonstrate to be consistent both in terms of the redshift calibration itself and in terms of resulting cosmological constraints within 0.1$σ$. We describe the process used to produce an ensemble of redshift distributions that account for several known sources of uncertainty. Among these, imperfection in the calibration sample due to the lack of faint, representative spectra is the dominant factor. The final uncertainty on mean redshift in each bin is $σ_{\langle z\rangle} = [0.012, 0.008,0.009, 0.024]$. We ensure the robustness of the redshift distributions by leveraging new image simulations and a cross-check with galaxy shape information via the shear ratio (SR) method.

Yin, B. [Duke U.] (ORCID:0009000656049980)↗

Surface species formed by the adsorption and dissociation of water molecules on Ru(0001) surface containing a small coverage of carbon atoms studied by scanning tunneling microscopy

The adsorption and dissociation of water on a Ru(0001) surface containing a small amount ({le} 3 %) of carbon impurities was studied by scanning tunneling microscopy (STM). Various surface species are formed depending on the temperature. These include molecular H{sub 2}O, H{sub 2}O-C complexes, H, O, OH and CH. Clusters of either pure H{sub 2}O or mixed H{sub 2}O-OH species are also formed. Each of these species produces a characteristic contrast in the STM images and can be identified by experiment and by ab initio total energy calculations coupled with STM image simulations. Manipulation of individual species via excitation of vibrational modes with the tunneling electrons has been used as supporting evidence.

36 MATERIALS SCIENCE↗

Thorough characterization of a EUV mask

We reported that we were successful in our 45nm technology node device demonstration in February 2008 and 22nm node technology node device patterning in February 2009 using ASML's Alpha Demo Tool (ADT). In order to insert extreme ultraviolet (EUV) lithography at the 15nm technology node and beyond, we have thoroughly characterized one EUV mask, a so-called NOVACD mask. In this paper, we report on three topics, The first topic is an analysis of line edge roughness (LER) using a mask Scanning Electron Microscope (SEM), an Atomic Force Microscope (AFM) and the Actinic Inspection Tool (AIT) to compare resist images printed with the ASML ADT. The results of the analysis show a good correlation between the mask AFM and the mask SEM measurements, However, the resist printing results for the isolated space patterns are slightly different. The cause ofthis discrepancy may be resist blur, image log slope and SEM image quality and so on. The second topic is an analysis of mask topography using an AFM and relative reflectivity of mirror and absorber surface using the AIT, The AFM data show 6 and 7 angstrom rms roughness for mirror and absorber, respectively. The reflectivity measurements show that the mirror reflects EUV light about 20 times higher than absorber. The last topic is an analysis of a 32nm technology node SRAM cell which includes a comparison of mask SEM image, AIT image, resist image and simulation results. The ADT images of the SRAM pattern were of high quality even though the mask patters were not corrected for OPC or any EUV-specific effects. Image simulation results were in good agreement with the printing results.

36 MATERIALS SCIENCE↗

Metal-and hydrogen-bonding competition during water absorption on Pd(111) and Ru(0001)

The initial stages of water adsorption on the Pd(111) and Ru(0001) surfaces have been investigated experimentally by Scanning Tunneling Microscopy in the temperature range between 40 K and 130 K, and theoretically with Density Functional Theory (DFT) total energy calculations and STM image simulations. Below 125 K water dissociation does not occur at any appreciable rate and only molecular films are formed. Film growth starts by the formation of flat hexamer clusters where the molecules bind to the metal substrate through the O-lone pair while making H-bonds with neighboring molecules. As coverage increases, larger networks of linked hexagons are formed with a honeycomb structure, which requires a fraction of the water molecules to have their molecular plane perpendicular to the metal surface with reduced water-metal interaction. Energy minimization favors the growth of networks with limited width. As additional water molecules adsorb on the surface they attach to the periphery of existing islands, where they interact only weakly with the metal substrate. These molecules hop along the periphery of the clusters at intermediate temperatures. At higher temperatures they bind to the metal to continue the honeycomb growth. The water-Ru interaction is significantly stronger than the water-Pd interaction, which is consistent with the greater degree of hydrogen-bonded network formation and reduced water-metal bonding observed on Pd relative to Ru.

36 MATERIALS SCIENCE↗

Monte Carlo simulation of breast imaging using synchrotron radiation

Purpose: Synchrotron radiation (SR), being the brightest artificial source of x-rays with a very promising geometry, has raised the scientific expectations that it could be used for breast imaging with optimized results. The ''in situ'' evaluation of this technique is difficult to perform, mostly due to the limited available SR facilities worldwide. In this study, a simulation model for SR breast imaging was developed, based on Monte Carlo simulation techniques, and validated using data acquired in the SYRMEP beamline of the Elettra facility in Trieste, Italy. Furthermore, primary results concerning the performance of SR were derived. Methods: The developed model includes the exact setup of the SR beamline, considering that the x-ray source is located at almost 23 m from the slit, while the photon energy was considered to originate from a very narrow Gaussian spectrum. Breast phantoms, made of Perspex and filled with air cavities, were irradiated with energies in the range of 16-28 keV. The model included a Gd{sub 2}O{sub 2}S detector with the same characteristics as the one available in the SYRMEP beamline. Following the development and validation of the model, experiments were performed in order to evaluate the contrast resolution of SR. A phantom made of adipose tissue and filled with inhomogeneities of several compositions and sizes was designed and utilized to simulate the irradiation under conventional mammography and SR conditions. Results: The validation results of the model showed an excellent agreement with the experimental data, with the correlation for contrast being 0.996. Significant differences only appeared at the edges of the phantom, where phase effects occur. The initial evaluation experiments revealed that SR shows very good performance in terms of the image quality indices utilized, namely subject contrast and contrast to noise ratio. The response of subject contrast to energy is monotonic; however, this does not stand for contrast to noise ratio, since there is a range of optimal performance for SR (18-21 keV). In comparison to conventional mammography, SR shows improved subject contrast for energies lower than the mean energy of each spectrum. Conclusions: The comparison of the results of the two models, conventional and SR, proved that SR exhibits better performance in the majority of cases. The proposed simulation model offers the possibility to perform exhaustive search to evaluate the performance of SR in clinical applications such as breast imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved reconstruction stability for chemical shift encoded hyperpolarized 13 C magnetic resonance spectroscopic imaging using k‐t spiral acquisitions

Purpose A multiecho, field of view (FOV)‐oversampled k‐t spiral acquisition and direct iterative decomposition of water and fat with echo asymmetry and least‐squares estimation reconstruction is demonstrated to improve the stability of hyperpolarized 13 C magnetic resonance spectroscopic imaging (MRSI) in the presence of signal ambiguities attributed to low‐SNR (signal‐to‐noise‐ratio) species, local uncertainties in metabolite peaks, and echo‐to‐echo signal inconsistencies. Theory k‐t spiral acquisitions redistribute readout points to be more densely spaced radially in k‐space by acquiring an FOV and matrix that are oversampled by η . These more densely spaced spiral turns constitute effective intraspiral echoes and can supplement conventional interspiral echoes to improve spectral separation and reduce spectral cross‐talk to better resolve 13 C‐labeled species for spectroscopic imaging. Methods Digital simulations and imaging phantom experiments were performed for a range of interspiral echo spacings and η using multiecho, k‐t spiral acquisitions. Image spectral cross‐talk artifacts were evaluated both qualitatively and quantitatively as the percent error in measured metabolite ratios. In vivo murine experiments evaluated the feasibility of multiecho, k‐t spiral [1‐ 13 C]pyruvate MRSI to reduce spectral cross‐talk for 3 scenarios of different expected reconstruction stability. Results Digital simulations and imaging phantom experiments both demonstrated reduced or comparable image spectral cross‐talk and percent errors in measured metabolite ratios with increasing η and better choices of echo spacings. In vivo images displayed markedly reduced spectral cross‐talk in lactate images acquired with η = 7 versus η = 1. Conclusion The precision of hyperpolarized 13 C metabolic imaging and quantification in the presence of low‐SNR species, local uncertainties in metabolite resonances, and echo‐to‐echo signal inconsistencies can be improved with the use of FOV‐oversampled k‐t spiral acquisitions.

Macdonald, Erin B.↗

Transforming Magnetic Resonance Imaging Education through Simulation-Based Training

Clinical instructors are facing the challenge of limited clinical training sites as the opportunities to train on actual patients become less available. In addition, work regulations, productivity requirements, and patients’ awareness of trainees “practicing” on them has led to a decline in training opportunities. These factors reduced training experience into fewer direct patient encounters, and fewer opportunities to perform procedures. This study assesses the perception of students on the MRI simulation training for undergraduate medical imaging students.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comprehensive simulation framework for imaging single particles and biomolecules at the European X-ray Free-Electron Laser

The advent of newer, brighter, and more coherent X-ray sources, such as X-ray Free-Electron Lasers (XFELs), represents a tremendous growth in the potential to apply coherent X-rays to determine the structure of materials from the micron-scale down to the Angstrom-scale. There is a significant need for a multi-physics simulation framework to perform source-to-detector simulations for a single particle imaging experiment, including (i) the multidimensional simulation of the X-ray source; (ii) simulation of the wave-optics propagation of the coherent XFEL beams; (iii) atomistic modelling of photon-material interactions; (iv) simulation of the time-dependent diffraction process, including incoherent scattering; (v) assembling noisy and incomplete diffraction intensities into a three-dimensional data set using the Expansion-Maximisation-Compression (EMC) algorithm and (vi) phase retrieval to obtain structural information. Furthermore, we demonstrate the framework by simulating a single-particle experiment for a nitrogenase iron protein using parameters of the SPB/SFX instrument of the European XFEL. This exercise demonstrably yields interpretable consequences for structure determination that are crucial yet currently unavailable for experiment design.

42 ENGINEERING↗

Evaluating Cryo–TEM Reconstruction Accuracy of Self–Assembled Polymer Nanostructures

Cryogenic transmission electron microscopy (cryo–TEM) combined with single particle analysis (SPA) is an emerging imaging approach for soft materials. However, the accuracy of SPA–reconstructed nanostructures, particularly those formed by synthetic polymers, remains uncertain due to potential packing heterogeneity of the nanostructures. In this study, the combination of molecular dynamics (MD) simulations and image simulations is utilized to validate the accuracy of cryo–TEM 3D reconstructions of self–assembled polypeptoid fibril nanostructures. Using CryoSPARC software, image simulations, 2D classifications, ab initio reconstructions, and homogenous refinements are performed. By comparing the results with atomic models, the recovery of molecular details is assessed, heterogeneous structures are identified, and the influence of extraction location on the reconstructions is evaluated. In conclusion, these findings confirm the fidelity of single particle analysis in accurately resolving complex structural characteristics and heterogeneous structures, exhibiting its potential as a valuable tool for detailed structural analysis of synthetic polymers and soft materials.

36 MATERIALS SCIENCE↗

SU-E-J-125: A Novel IMRT Planning Technique to Spare Sacral Bone Marrow in Pelvic Cancer Patients

Purpose: Develop an IMRT planning technique that can preferentially spare sacral bone marrow for pelvic cancer patients. Methods: Six pelvic cancer patients (two each with anal, cervical, and rectal cancer) were enrolled in an IRB approved protocol to obtain FLT PET images at simulation, during, and post chemoradiation therapy. Initially, conventional IMRT plans were created to maintain target coverage and reduce dose to OARs such as bladder, bowel, rectum, and femoral heads. Simulation FLT PET images were used to create IMRT plans to spare bone marrow identified as regions with SUV of 2 or greater (IMRT-BMS) within the pelvic bones from top of L3 to 5mm below the greater trochanter without compromising PTV coverage or OAR sparing when compared to the initial IMRT plan. IMRT-BMS plans used 8–10 beam angles that surrounded the subject. These plans were used for treatment. Retrospectively, the same simulation FLT PET images were used to create IMRT plans that spared bone marrow located in the sacral pelvic bone region (IMRT-FAN) also without compromising PTV coverage or OAR sparing. IMRT-FAN plans used 16 beam angles every 12° anteriorly from 90° – 270°. Optimization objectives for the sacral bone marrow avoidance region were weighted to reduce ≥V10. Results: IMRT-FAN reduced dose to the sacral bone marrow for all six subjects. The average V5, V10, V20, and V30 differences from the IMRT-BMS plan were −2.2 ± 1.7%, −11.4 ± 3.6%, −17.6 ± 5.1%, and −19.1 ± 8.1% respectively. Average PTV coverage change was 0.5% ± 0.8% from the conventional IMRT plan. Conclusion: An IMRT planning technique that uses beams from the anterior and lateral directions reduced the volume of sacral bone marrow that receives ≤10Gy while maintaining PTV coverage and OAR sparing. Additionally, the volume of sacral bone marrow that received 20 or 30 Gy was also reduced.

60 APPLIED LIFE SCIENCES↗

WE-AB-303-03: A Scheme for Real-Time, Marker-Less and Low-Dose Tumor Tracking Using Scattering Imaging: Monte Carlo Simulation Study

Purpose: In-treatment tumor localization is critical for the management of tumor motion in lung cancer radiotherapy. Conventional tumor-tracking methods using a kV or MV x-ray projection has limited contrast. To facilitate real-time, marker-less and low-dose in-treatment image tumor tracking, we propose a novel scheme using Compton scatter imaging. This study reports Monte Carlo (MC) simulations on this scheme for the purpose of proof-of-principle. Methods: A slit x-ray beam along the patient superior-inferior (SI) direction is directed to the patient, intersecting the patient lung at a 2D plane containing majority part of the tumor motion trajectory. X-ray photons are scattered due to Compton effect from this plane, which are spatially collimated by, e.g., a pinhole, on one side of the plane and then captured by a detector behind it. The captured image, after correcting for x-ray attenuation and scatter angle variation, reflects the electron density, which allows visualization of the instantaneous anatomy on this plane. We performed MC studies on a phantom and a patient case for the initial test of this proposed method. Results: In the phantom case, the contrast-resolution calculated using tumor/lung as foreground/background for kV fluoroscopy, cone-beam CT, and scattering image were 0.0625, 0.6993, and 0.5290, respectively. In the patient case, tumor motion can be clearly observed in the scatter images. Compared to fluoroscopy, scattering imaging also significantly reduced imaging dose because of its narrower beam design. Conclusion: MC simulation studies demonstrated the potential of the proposed scheme in terms of capturing the instantaneous anatomy of a patient on a 2D plane. Clear visualization of the tumor will probably facilitate ‘marker-less’ and ‘real-time’ tumor tracking with low imaging dose. NIH (1R01CA154747-01, 1R21CA178787-01A1 and 1R21EB017978-01A1)

60 APPLIED LIFE SCIENCES↗

Simulation of Properties of Images with Atomic Resolution in a Scanning Probe Microscope

A method for simulation of images in a scanning probe microscope (SPM) using simultaneous wavelet transform and median filtering is proposed. The wavelet transform with the fourth-order Daubechies kernel is used. Such a transform makes it possible to select details of different scales in the SPM image and, hence, study fractal properties of surfaces. Simulation is used to show that ultrahigh (atomic) resolution is possible in SPM provided that the size of the contact region in the probe–sample system is significantly greater than atomic size and the lattice atoms are randomly distributed. Contrast inversion in the SPM images in the multiscan mode is interpreted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of Repositioning Accuracy of Two Commercially Available Immobilization Systems for Treatment of Head-and-Neck Tumors Using Simulation Computed Tomography Imaging

Purpose: To compare the setup accuracy, comfort level, and setup time of two immobilization systems used in head-and-neck radiotherapy. Methods and Materials: Between February 2004 and January 2005, 21 patients undergoing radiotherapy for head-and-neck tumors were assigned to one of two immobilization devices: a standard thermoplastic head-and-shoulder mask fixed to a carbon fiber base (Type S) or a thermoplastic head mask fixed to the Accufix cantilever board equipped with the shoulder depression system. All patients underwent planning computed tomography (CT) followed by repeated control CT under simulation conditions during the course of therapy. The CT images were subsequently co-registered and setup accuracy was examined by recording displacement in the three cartesian planes at six anatomic landmarks and calculating the three-dimensional vector errors. In addition, the setup time and comfort of the two systems were compared. Results: A total of 64 CT data sets were analyzed. No difference was found in the cartesian total displacement errors or total vector displacement errors between the two populations at any landmark considered. A trend was noted toward a smaller mean systemic error for the upper landmarks favoring the Accufix system. No difference was noted in the setup time or comfort level between the two systems. Conclusion: No significant difference in the three-dimensional setup accuracy was identified between the two immobilization systems compared. The data from this study reassure us that our technique provides accurate patient immobilization, allowing us to limit our planning target volume to <4 mm when treating head-and-neck tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗