Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image registration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Advanced Land Imager Assessment System

The Advanced Land Imager Assessment System (ALIAS) supports radiometric and geometric image processing for the Advanced Land Imager (ALI) instrument onboard NASA s Earth Observing-1 (EO-1) satellite. ALIAS consists of two processing subsystems for radiometric and geometric processing of the ALI s multispectral imagery. The radiometric processing subsystem characterizes and corrects, where possible, radiometric qualities including: coherent, impulse; and random noise; signal-to-noise ratios (SNRs); detector operability; gain; bias; saturation levels; striping and banding; and the stability of detector performance. The geometric processing subsystem and analysis capabilities support sensor alignment calibrations, sensor chip assembly (SCA)-to-SCA alignments and band-to-band alignment; and perform geodetic accuracy assessments, modulation transfer function (MTF) characterizations, and image-to-image characterizations. ALIAS also characterizes and corrects band-toband registration, and performs systematic precision and terrain correction of ALI images. This system can geometrically correct, and automatically mosaic, the SCA image strips into a seamless, map-projected image. This system provides a large database, which enables bulk trending for all ALI image data and significant instrument telemetry. Bulk trending consists of two functions: Housekeeping Processing and Bulk Radiometric Processing. The Housekeeping function pulls telemetry and temperature information from the instrument housekeeping files and writes this information to a database for trending. The Bulk Radiometric Processing function writes statistical information from the dark data acquired before and after the Earth imagery and the lamp data to the database for trending. This allows for multi-scene statistical analyses.

Chander, Gyanesh↗

Registration accuracy and attitude accuracy

Since higher spatial resolution is desired by many applications disciplines coupled with registration in the sub-to-1 pixel range, improved registration accuracy has become necessary. The trend is likely to continue, with image data resolution of 10 meters or less being a routine requirement before the end of this decade. This registration accuracy can only be achieved by the combination of registration and attitude accuracy. This report described the need for improving the attitude accuracy. The relationship between registration accuracy and attitude accuracy is shown, along with criteria for design consideration in establishing adequate attitude accuracy. A precise on-board attitude control system design is essential to provide the attitude accuracy needed to support the subpixel accuracy required for registration of higher resolution images.

Fang, A. C.↗

Spaceborne scanner imaging system errors

The individual sensor system design elements which are the priori components in the registration and rectification process, and the potential impact of error budgets on multitemporal registration and side-lap registration are analyzed. The properties of scanner, MLA, and SAR imaging systems are reviewed. Each sensor displays internal distortion properties which to varying degrees make it difficult to generate on orthophoto projection of the data acceptable for multiple pass registration or meeting national map accuracy standards and is also affected to varying degrees by relief displacements in moderate to hilly terrain. Nonsensor related distortions, associated with the accuracy of ephemeris determination and platform stability, have a major impact on local geometric distortions. Platform stability improvements expected from the new multi mission spacecraft series and improved ephemeris and ground control point determination from the NAVSTAR/global positioning satellite systems are reviewed.

Prakash, A.↗

Multiple-Event, Single-Photon Counting Imaging Sensor

The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

Zheng, Xinyu↗

A New Instrument for Measurement of the Solar Aureole Radiance Distribution from Unstable Platforms

A novel imaging solar aureole radiometer, which can obtain absolute radiometric measurements of the solar aureole when operated on an unstable platform is described. A CCD array is used to image the aureole, while a neutral density occulter on a long pole blocks the direct solar radiation. This ensures accurate direction registration as the sun appears in acquired images, and the total circumsolar region is measured simultaneously. The imaging nature of this instrument along with a special triggering device permit acquisition of the circumsolar sky radiance within 7.5 degrees of the center of the solar disk, and within 1 degree of the edge of the solar disk. This innovation makes possible for the first time, reliable and accurate radiometric measurements of the solar aureole from unstable mobile platforms such as ships. This allows determination small angle atmospheric scattering. The instrument has been used in field studies of atmospheric aerosols and will be used in satellite validation and calibration campaigns.

Ritter, Joseph M.↗

Thematic Mapper image quality: Preliminary results

Based on images analyzed so far, the band to band registration accuracy of the thematic mapper is very good. For bands within the same focal plane, the mean misregistrations are well within the specification, 0.2 pixels. For bands between the cooled and uncooled focal planes, there is a consistent mean misregistration of 0.5 pixels along-scan and 0.2-0.3 pixels across-scan. It exceeds the permitted 0.3 pixels for registration of bands between focal planes. If the mean misregistrations were removed by the data processing software, an analysis of the standard deviation of the misregistration indicates all band combinations would meet the registration specifications except for those including the thermal band. Analysis of the periodic noise in one image indicates a noise component in band 1 with a spatial frequency equivalent to 3.2 pixels in the along-scan direction.

Wrigley, R. C.↗

Thematic mapper image quality - Preliminary results

Based on images analyzed so far, the band to band registration accuracy of the thematic mapper is very good. For bands within the same focal plane, the mean misregistrations are well within the specification, 0.2 pixels. For bands between the cooled and uncooled focal planes, there is a consistent mean misregistration of 0.5 pixels along-scan and 0.2-0.3 pixels across-scan. It exceeds the permitted 0.3 pixels for registration of bands between focal planes. If the mean misregistrations were removed by the data processing software, an analysis of the standard deviation of the misregistration indicates all band combinations would meet the registration specifications except for those including the thermal band. Analysis of the periodic noise in one image indicates a noise component in band 1 with a spatial frequency equivalent to 3.2 pixels in the along-scan direction.

Wrigley, R. C.↗

Hyperspectral Fluorescence and Reflectance Imaging Instrument

The system is a single hyperspectral imaging instrument that has the unique capability to acquire both fluorescence and reflectance high-spatial-resolution data that is inherently spatially and spectrally registered. Potential uses of this instrument include plant stress monitoring, counterfeit document detection, biomedical imaging, forensic imaging, and general materials identification. Until now, reflectance and fluorescence spectral imaging have been performed by separate instruments. Neither a reflectance spectral image nor a fluorescence spectral image alone yields as much information about a target surface as does a combination of the two modalities. Before this system was developed, to benefit from this combination, analysts needed to perform time-consuming post-processing efforts to co-register the reflective and fluorescence information. With this instrument, the inherent spatial and spectral registration of the reflectance and fluorescence images minimizes the need for this post-processing step. The main challenge for this technology is to detect the fluorescence signal in the presence of a much stronger reflectance signal. To meet this challenge, the instrument modulates artificial light sources from ultraviolet through the visible to the near-infrared part of the spectrum; in this way, both the reflective and fluorescence signals can be measured through differencing processes to optimize fluorescence and reflectance spectra as needed. The main functional components of the instrument are a hyperspectral imager, an illumination system, and an image-plane scanner. The hyperspectral imager is a one-dimensional (line) imaging spectrometer that includes a spectrally dispersive element and a two-dimensional focal plane detector array. The spectral range of the current imaging spectrometer is between 400 to 1,000 nm, and the wavelength resolution is approximately 3 nm. The illumination system consists of narrowband blue, ultraviolet, and other discrete wavelength light-emitting-diode (LED) sources and white-light LED sources designed to produce consistently spatially stable light. White LEDs provide illumination for the measurement of reflectance spectra, while narrowband blue and UV LEDs are used to excite fluorescence. Each spectral type of LED can be turned on or off depending on the specific remote-sensing process being performed. Uniformity of illumination is achieved by using an array of LEDs and/or an integrating sphere or other diffusing surface. The image plane scanner uses a fore optic with a field of view large enough to provide an entire scan line on the image plane. It builds up a two-dimensional image in pushbroom fashion as the target is scanned across the image plane either by moving the object or moving the fore optic. For fluorescence detection, spectral filtering of a narrowband light illumination source is sometimes necessary to minimize the interference of the source spectrum wings with the fluorescence signal. Spectral filtering is achieved with optical interference filters and absorption glasses. This dual spectral imaging capability will enable the optimization of reflective, fluorescence, and fused datasets as well as a cost-effective design for multispectral imaging solutions. This system has been used in plant stress detection studies and in currency analysis.

Ryan, Robert E.↗

High-Procession Eye Tracking Using Fundus Images

Fundus images provide high optical gain for eye movement tracking, i.e. large image displacements occur as a result of small eye rotations. Subpixel registration techniques can provide resolution better than 1 arc minute using images acquired with a CCD camera. Ocular torsion may also be estimated, with a precision of approximately 0.1 degree. This talk will discuss the software algorithms used to attain this performance.

Mulligan, Jeffrey B.↗

Registration of video sequences from multiple sensors

In this paper, we describe an approach for registration of video sequences from a suite of multiple sensors including television, infrared and radar. Video sequences generated by these sensors may contain abrupt changes in local contrast and inconsistent image features, which pose additional difficulties for registration. Our approach to registration addresses the difficulties caused by using multiple sensors. We use a representation for registration that is invariant to local contrast changes, followed by smoothing of the resulting error measure used for registration, for robust estimation of registration parameters. We use an iterative procedure to reduce the effect of inconsistent features. Finally, we describe a method that uses same-sensor registration to aide in performing registration of sequences of video frames across multiple sensors.

Sharma, Ravi K.↗

Radiometric correction of SAR images of varying terrain heights

The advantages and disadvantages of three different approaches to solving the problem of the radiometric correction of synthetic aperture radar (SAR) images of varying terrain heights are presented. The first approach involves registration of a digital elevation model (DEM) of the terrain to the image, determination of the local elevation and incidence angles, and appropriate radiometric correction. The second approach uses a DEM generated from interferometric SAR data to derive the elevation and incidence angle maps. In the third approach, a monopulse technique is employed to determine the elevation angle only. The relative errors in radiometric correction between these approaches are assessed. Calibration errors are estimated using corner reflectors deployed within some of the scenes imaged by the Jet Propulsion Laboratory airborne SAR (JPL AIRSAR).

Freeman, A.↗

Interpretation Techniques Development

The processes, algorithms and procedures for extraction and interpretation of ERTS-1 data are discussed. Analysis of data acquired temporally is possible through geometric correction, correlation, and registration techniques. The powerful techniques in image enhancement developed for the lunar and planetary programs are valuable for Earth Resources Survey programs. There is evidence that both optical and digital methods of spatial information extraction can provide valuable sources of data information the ERTS system. The techniques available, even for a limited number of bands and limited resolution can be effectively used to extract much of the information required by resource managers.

Alford, W. L.↗

Interpretation techniques

The image enhancement and geometric correction and registration techniques developed and/or demonstrated on ERTS data are relatively mature and greatly enhance the utility of the data for a large variety of users. Pattern recognition was improved by the use of signature extension, feature extension, and other classification techniques. Many of these techniques need to be developed and generalized to become operationally useful. Advancements in the mass precision processing of ERTS were demonstrated, providing the hope for future earth resources data to be provided in a more readily usable state. Also in evidence is an increasing and healthy interaction between the techniques developers and the user/applications investigators.

Dragg, J. L.↗

Potential of multisensor data and strategies for data acquisition and analysis

Registration and simultaneous analysis of multisensor images is useful because the multiple data sets can be compressed through image processing techniques to facilitate interpretation. This also allows integration of other spatial data sets. Techniques being developed to analyze multisensor images involve comparison of image data with a library of attributes based on physical properties measured by each sensor. This results in the ability to characterize geologic units based on their similarity to the library attributes, as well as discriminate among them. Several studies can provide information on ways to optimize multisensor remote sensing. Continued analyses of the Death Valley and San Rafael Swell data sets can provide insight into tradeoffs in spectral and spatial resolutions of the various sensors used to obtain the coregistered data sets. These include imagery from LANDSAT, SEASAT, HCMM, SIR-A, 11-channel VIS-NIR, thermal inertia images, and aircraft L- and X-band radar.

Evans, D.↗

Analysis and Evaluation of the LANDSAT-4 MSS and TM Sensors and Ground Data Processing Systems: Early Results

The MSS and TM sensor performances were evaluated by studying both the sensors and the characteristics of the data. Information content analysis, image statistics, band-to-band registration, the presence of failed or failing detectors, and sensor resolution are discussed. The TM data were explored from the point of view of adequacy of the ground processing and improvements that could be made to compensate for sensor problems and deficiencies. Radiometric correction processing, compensation for a failed detector, and geometric correction processing are also considered.

Bernstein, R.↗

Application of advanced signal processing techniques to the rectification and registration of spaceborne imagery

The development of an ERTS/MSS image processing system responsive to the needs of the user community is discussed. An overview of the TRW ERTS/MSS processor is presented, followed by a more detailed discussion of image processing functions satisfied by the system. The particular functions chosen for discussion are evolved from advanced signal processing techniques rooted in the areas of communication and control. These examples show how classical aerospace technology can be transferred to solve the more contemporary problems confronting the users of spaceborne imagery.

Caron, R. H.↗