Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

The Jimsonde - A high resolution temperature sensor.

The Jimsonde, a high-resolution lightweight temperature sensor developed for use with the FPS-16 Radar/Jimsphere wind system, and its related systems are discussed; and an error analysis that shows the sonde to have an rms error of 0.41 C at sea level and 0.56 C at 18 km is presented. Five flight tests, a sequence of four tests and one individual test, of the Jimsonde were made. For comparative purposes, radiosonde temperature data are presented along with the Jimsonde data.

Camp, D. W.↗

High resolution solar X-ray studies

Two high resolution solar X-ray payloads and their launches on Aerobee rockets with pointing system are described. The payloads included 5 to 25A X-ray spectrometers, multiaperture X-ray cameras, and command box attitude control inflight by means of a television image radioed to ground. Spatial resolution ranged from five arc minutes to ten arc seconds and spectral resolution ranged from 500 to 3000. Several laboratory tasks were completed in order to achieve the desired resolution. These included (1) development of techniques to align grid collimators, (2) studies of the spectrometric properties of crystals, (3) measurements of the absorption coefficients of various materials used in X-ray spectrometers, (4) evaluation of the performance of multiaperture cameras, and (5) development of facilities.

Blake, R. L.↗

High resolution Fourier interferometer-spectrophotopolarimeter

A high-resolution Fourier interferometer-spectrophotopolarimeter is provided using a single linear polarizer-analyzer the transmission axis azimuth of which is positioned successively in the three orientations of 0 deg, 45 deg, and 90 deg, in front of a detector; four flat mirrors, three of which are switchable to either of two positions to direct an incoming beam from an interferometer to the polarizer-analyzer around a sample cell transmitted through a medium in a cell and reflected by medium in the cell; and four fixed focussing lenses, all located in a sample chamber attached at the exit side of the interferometer. This arrangement can provide the distribution of energy and complete polarization state across the spectrum of the reference light entering from the interferometer; the same light after a fixed-angle reflection from the sample cell containing a medium to be analyzed; and the same light after direct transmission through the same sample cell, with the spectral resolution provided by the interferometer.

Fymat, A. L.↗

High resolution infrared absorptivities for gaseous chlorine nitrate

High resolution infrared absorptivities of chlorine nitrate (ClONO2) are required in order to quantitatively evaluate, by examination of infrared spectra obtained recently from balloon-borne spectrometers, the possible occurrence of this compound in the stratosphere. In the present study, infrared absorptivities for four absorption bands of gaseous ClONO2 have been measured at 0.0625 per cm spectral resolution with a Fourier transform infrared (FT-IR) system. Spectra were obtained at two pressures (0.05 and 1.05 torr) of pure ClONO2 and with 125 torr of N2 added to a 0.50 torr sample. Absorptivities for a range of spectral resolutions (0.0625, 0.125, 0.25 and 0.50 per cm) have been calculated from the data.

Graham, R. A.↗

High resolution spectrograph for the Space Telescope

The high resolution spectrograph (HRS) for ultraviolet astronomy with the Space Telescope will provide a spectral resolution of approximately 120,000 over a nominal wavelength range of 110-320 nm, together with a spatial resolution of about 0.25 arc seconds. The two detectors will consist of 512-element Digicons with cesium telluride and cesium iodide photocathodes, respectively. Photoelectrons in transit between the photocathodes and the diodes within the Digicons can be deflected in two axes with 12-bit resolution. This feature facilitates a design that emphasizes reliability since (once a hermetic seal is opened in orbit), only two moving parts, a grating carrousel and a shutter, are required for regular operation of the HRS. The instrument will be controlled by a computer in the spacecraft. The scientific objectives of the HRS investigation relate to interstellar matter in our own and nearby galaxies, physical processes of stellar mass loss and mass transfer, chemical abundances, bright quasars and Seyfert galaxy nuclei, and solar system phenomena.

Brandt, J. C.↗

Ultraviolet high-resolution spectroscopy from the Space Telescope

The High Resolution Spectrograph is one of five scientific instruments which will be part of the Space Telescope observatory. The spectrograph was designed to take advantage of the imaging and pointing capabilities of the telescope to obtain ultraviolet spectra with spectral resolution comparable to large, ground-based coudeinstruments. Some of the results of the ground-based testing program will be described, along with applications of these properties to future science programs.

Ebbets, D. C.↗

High-resolution infrared observations in IC 5146

High-resolution near-infrared and far-infrared observations are presented of the southeastern molecular cloud fragment in the IC 5146 dark cloud. These observations rule out earlier suggestions for the formation of massive stars in this fragment.

Wilking, B. A.↗

High-resolution spectrum of Cygnus X-1

A high resolution spectrum of Cygnus X-1 in the 45 to 600 keV range is presented. The measurement was made by the HEAO 3 gamma ray spectrometer during 82 days in the fall of 1979 and spring of 1980, when the source was in its normal low state. Results of a search for narrow emission lines from the source are reported. The spectrum shows no significant narrow features. The 3 delta upper limit to a narrow 511 keV annihilation line is 3 x 0.0001 photons/sq cm/s. There is also no evidence in HEAO 3 broadband data above 500 keV for the broad annihilation feature observed by HEAO 1.

Ling, J. C.↗

High-resolution surface photometry of elliptical galaxies

High-resolution CCD surface photometry profiles have been obtained for a sample of 42 nearby elliptical and SO galaxies as a first step in a program to investigate their central structure and core properties. A comparison of the present profiles to those of other observers shows that the accuracy of the central surface brightnesses is to better than 0.02 mag rms. Central resolution is limited by the atmospheric seeing PSF which is measured for each profile. A hybrid Fourier deconvolution procedure has been developed to correct the surface photometry for seeing in a model-independent way. Tests of the procedure on simulated galaxy images show that intrinsic core radii equal to the seeing FWHM or larger can be recovered from the observations. Application of the deconvolution procedure to the observed galaxies yields surface photometry profiles of slightly sub-arc second resolution.

Lauer, T. R.↗

Rarefied aerodynamics and upper atmospheric flight results from the Orbiter High Resolution Accelerometer Package experiment

Data from the High Resolution Accelerometer Package (HiRAP) experiment on the Space Shuttle Orbiter have been analyzed for 10 flights to produce lift-drag (L/D) ratios in the free molecule, transition, and continuum flow flight regimes. Freestream density is also obtained in the altitude range from 60 km to 160 km using an aerodynamic model based upon earlier flight analysis of accelerometer data. The results of the L/D analysis of the latest four flights have been compared with the aerodynamic model developed from the first six HiRAP missions. The new data agree with the established flight-derived model, thereby validating earlier analysis. However, the arithmetic mean of the 10 flight-derived L/D values in the free molecular flow regime is 0.053 (+ or - 0.1) as compared to the initial value of 0.10 (+ or - 0.3), determined from STS-6. Updates to the Orbiter aerodynamic model values and calibration factors have been incorporated into the density calculations for all 10 flights to provide realistic absolute density. The derived density altitude profiles, which have been normalized to the U.S. Standard Atmosphere 1976, are characterized by a large amplitude wave pattern relative to the standard as seen in the initial flight analysis.

Blanchard, R. C.↗

Interstellar absorption lines in high-resolution IUE spectra of cataclysmic variables

High-resolution ultraviolet spectra of five cataclysmic variables obtained with the IUE are used to investigate the character of the interstellar medium in the vicinity of the sun. These spectra reveal narrow absorption features of neutral and singly ionized interstellar species, and, in SS Cyg, narrow velocity-shifted absorption features of C IV, Si IV, and Si III. Using the column densities implied by the absorption features of the neutral and singly ionized species, values for the depletion of Si, Mg, Mn, and Fe from the gas phase of the interstellar medium in the vicinity of the sun are obtained. These hydrogen column densities are of particular importance in constraining the soft X-ray luminosity of cataclysmic variables because of the severe attenuation of the soft X-ray flux of cataclysmic variables by photoelectric absorption in the interstellar medium. In addition, using the column densities implied by the absorption features of C IV, Si IV, and Si III in the spectrum of SS Cyg, the existence of an expanding H II region of interstellar gas photoionized by he EUV and soft X-ray flux of this cataclysmic variable are inferred.

Mauche, Christopher W.↗