Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Addressing Market Issues in Electrical Power Systems with Large Shares of Variable Renewable Energy

This paper reports recent findings from IEA Wind TCP Task 25, which compiles international experiences and research related to large-scale integration of wind and other renewable energy. In the paper, we address the main challenges for market integration of variable renewable energy, relating to price formation, cost recovery, balancing and other grid services. The paper gives an overview of recent scenario studies on electricity price impacts of (1) various generation, energy storage and demand types in different markets, and (2) different market designs and energy/climate policies. Studying markets with very high shares of variable renewable energy requires an improved set of analysis tools for forecasting market outcomes, estimating flexibility needs and sources, and assessing resource adequacy. Key market features need to be investigated within these improved analytical capabilities for systems transitioning to high shares of variable renewable energy, storage and flexible demand. System services that can be supported by markets will likely need to be revisited. Finally, this paper identifies open questions and suggested future market design work for supporting systems with very high shares of variable renewable energy, which are to be addressed in follow-up work of Task 25 collaborative research.

cost recovery↗

Modeling Structured Electrodes and Graded Porosity for Improving Discharge Rate Capability in Ultra-Thick Graphite|LiNi 0.6 Mn 0.2 Co 0.2 O 2 Batteries

Long-range electric vehicles (EVs) require high-energy-density batteries that also meet the power demands of high current charge and discharge. Ultra-thick (>100 μm) Lithium-ion battery electrodes are critical to enable this need, but slow ion transport in conventional uniform electrodes (UEs) reduces battery capacity at increasing charge/discharge rates. We present a 3D computational analysis on the impact of structured electrode (SE) and graded electrode (GE) geometries on the discharge rate capability of ultra-thick graphite|LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC-622) battery cells based on the footprint of a commercial EV pouch cell. SE cathodes with either a “grid” or “line” geometry and GEs with two layers of porosity were modeled. Based on the results of 230 models, we found that the electrolyte volume fraction is a key parameter that impacts capacity improvements in UEs, GEs, and SEs at 2 C–6 C discharge rates. SEs have the greatest discharge rate capability, outperforming GEs and UEs due to reduced Lithium-ion concentration gradients across the electrode thickness, which mitigates electrolyte depletion at high rates. The best SE model has a “grid” geometry with gravimetric and volumetric energy density improvements of 0.9%–4% at C/2–2 C and 18%–24% at 4 C–6 C relative to UEs.

25 ENERGY STORAGE↗

Using TRMM Field Campaign Data for Assessing GEOS Forecast and Assimilation Products

The wealth of in-situ measurements gathered during Tropical Rain Measuring Mission (TRMM) field campaigns over a wide range of tropical conditions constitute an important data source for evaluating the quality of global model forecasts and assimilated datasets. In this study we use selected observations of cloud microphysics and atmospheric sounding from TEFLUN-1998, SCEMEX-1998, and TRMMLBA-1999 to examine the assimilation and forecast fields produced by the operational GEOS-3 (Goddard Earth Observing System - version 3) global data assimilation system (DAS) and a new finite-volume DAS under development at the Data Assimilation Office. Additionally, TRMM field campaign measurements are used to verify the impact of assimilating rainfall and moisture data derived from TRMM Microwave Imager and Special Sensor Microwave/Imager instruments on the GEOS analysis. We will also explore issues concerning the 'error of representativeness' in using in-situ observations of quantities with large spatial and temporal variability such as precipitation for validating gridded global data products.

Hou, Arthur Y.↗

Discharge Chamber Primary Electron Modeling Activities in Three-Dimensions

Designing discharge chambers for ion thrusters involves many geometric configuration decisions. Various decisions will impact discharge chamber performance with respect to propellant utilization efficiency, ion production costs, and grid lifetime. These hardware design decisions can benefit from the assistance of computational modeling. Computational modeling for discharge chambers has been limited to two-dimensional codes that leveraged symmetry for interpretation into three-dimensional analysis. This paper presents model development activities towards a three-dimensional discharge chamber simulation to aid discharge chamber design decisions. Specifically, of the many geometric configuration decisions toward attainment of a worthy discharge chamber, this paper focuses on addressing magnetic circuit considerations with a three-dimensional discharge chamber simulation as a tool. With this tool, candidate discharge chamber magnetic circuit designs can be analyzed computationally to gain insight into factors that may influence discharge chamber performance such as: primary electron loss width in magnetic cusps, cathode tip position with respect to the low magnetic field volume, definition of a low magnetic field region, and maintenance of a low magnetic field region across the grid span. Corroborating experimental data will be obtained from mockup hardware tests. Initially, simulated candidate magnetic circuit designs will resemble previous successful thruster designs. To provide opportunity to improve beyond previous performance benchmarks, off-design modifications will be simulated and experimentally tested.

Steuber, Thomas J.↗

Fortalecimiento de la Electrificación Rural en Honduras: Una Evaluación Integrada de PV+BESS y Usos Productivos de la Electricidad en Gracias a Dios, Honduras [Empowering Rural Electrification in Honduras: An Integrated Assessment of PV/BESS and Productive Uses of Electricity in Gracias a Dios] (Spanish Translation)

Honduras faces significant challenges in its energy sector, particularly in rural areas where access to reliable and affordable electricity remains limited. The flagship rural electrification initiative for Honduras Secretary of Energy (SEN) is the Politica de Acceso Universal a la Electricidad (PAUEH - Universal Electricity Access Policy), a key solution for addressing this energy poverty is the deployment of more than 1700 distributed solar and hybrid mini-grid solutions. In late 2023 as a first step towards supporting SEN's electrification efforts, the National Renewable Energy Laboratory (NREL) developed a literature review of SEN electrification policy documents and conducted a series of technical capacity-building workshops with SEN and other energy sector stakeholders in Honduras focused on using NREL's open-source REopt tool to conduct techno-economic assessments and develop least-cost optimizations for potential solar + storage mini-grid systems. Building on some initial capacity building on mini-grid modeling, the National Renewable Energy Laboratory (NREL) worked with SEN to develop a detailed techno-economic assessment for electrifying two schools, a healthcare clinic, and a hospital in a hypothetical community within the department of Gracias a Dios. The analysis also evaluates the business case for cold storage productive use of energy (PUE) applications for the fisheries value chain and how the incorporation of these PUE loads potentially impacts both the viability of the PV+BESS solutions as well as local economic development. By assessing the potential for deployment of integrated PV/BESS systems to both support critical community services like education and healthcare, as well as potential for downstream enterprise and economic development, this analysis represents a first step that can help to inform specific strategies for development of pilot PV+BESS projects aligned with national priorities and sector level planning under PAUEH. This is the Spanish translation of NREL/TP-7A40-90865.

14 SOLAR ENERGY↗

Real-Time Federated Cyber-Transmission-Distribution Testbed Architecture for the Resiliency Analysis

With the ongoing automation driven by the push toward the smart electric grid and the advancement in associated cyber infrastructure, the interaction between physical [electric transmission and distribution (T&D) systems], cyber (communication, automation, and control), and human (grid operators and decision-makers) is increasingly becoming more complex. This creates the requirement of analyzing the effect of the transmission system on the distribution system and vice versa with consideration of the additional complexity of the cyber infrastructure. Such an integrated testbed will also help with resiliency analysis, where resiliency refers to the ability of the system to continue serving energy to the critical loads even with limited extreme contingencies. Interaction of the physical power grid with the cyber layer can be effectively modeled using real-time (RT) simulator for developing and validating various operational and control algorithms. Testbeds using RT simulators with multiple capabilities have been developed at different institutions. Still, no single existing testbed can offer full scalability while simultaneously meeting high fidelity requirements for resiliency experimentation. Co-simulating federated testbed assets can provide a scalable experimentation platform that can be leveraged for verification and validation. In this article, an architecture is developed for federated cyber-physical testbed. A local federation with two real-time simulators is developed: real-time digital simulator (RTDS) and OPAL-RT have been interfaced using VILLAS framework for end-to-end testing. Also, a real-time linear predictor is developed and integrated here to address the communication latency impact on geographically allocated federated RT simulation. Finally, resiliency analysis tools are formulated and utilized for T&D systems. Finally as an illustrative use case, the resiliency of a T&D test system is simulated, and the results are analyzed. A 179-bus Western Electricity Coordinating Council (WECC) transmission system is developed using OPAL-RT/ HYPERSIM, and a modified IEEE 13 node feeder system is modeled in RTDS/RSCAD and interfaced for resiliency analysis.

42 ENGINEERING↗

Characterization of DER Momentary Cessation and Rate-of-Change-of-Frequency Response

Momentary cessation (MC) and response to rate-of-change-of-frequency (ROCOF) are inverter responses that can have serious impact on the stability of the grid during abnormal conditions. Though IEEE Std 1547-2018 provides fairly well defined expected responses from inverter-based DERs during abnormal grid conditions, a significant portion of currently installed DERs in the distribution network do not have a well defined response to abnormal grid conditions. Any analysis of the grid involving inverter MC and ROCOF response must consider the specific characteristics of these responses for the installed DERs to have better confidence in the analysis results, especially for grids with high levels of DERs. However, there is lack of information on MC and ROCOF response for the inverters already installed in the field. In this paper, we examine a large data set of installed inverters to map the dominant population of installed inverters. This information is then used to characterize the most dominant MC and ROCOF responses of installed inverters using experimental data.

DER↗

SEEDS Moving Group Status Update

I will summarize the current status of the SEEDS Moving Group category and describe the importance of this sub-sample for the entire SEEDS survey. This presentation will include analysis of the sensitivity for the Moving Groups with general a comparison to other the other sub-categories. I will discuss the future impact of the Subaru SCExAO system for these targets and the advantage of using a specialized integral field spectrograph. Finally, I will present the impact of a pupil grid mask in order to produce fiducial spots in the focal plane that can be used for both photometry and astrometry.

McElwain, Michael↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Contemporary and Future-Scenario Substantial-Precipitation Events in the Missouri River Basin Using Object-Oriented Analysis

The Missouri River Basin is the largest single river basin in the United States, and, as such, it plays an important role in natural ecosystems as well as the country’s economy, through agriculture, hydroelectric power generation, and transportation. Episodes of heavy precipitation can have a substantial negative impact on all these aspects of the basin, so understanding how well these episodes are simulated and projected to change in the future climate is important. We analyzed contemporary and projected mid-century behavior of heavy-precipitation episodes using an object-oriented analysis to diagnose short-term (≥5-day) and extended-period (≥30-day) events with substantial precipitation, using PRISM gridded, observed precipitation and RegCM4 regional-climate simulations that used outputs from two different GCMs for boundary conditions. The simulations were produced for the North American portion of the CORDEX program. A 25 km grid was used for the simulations and for aggregated PRISM precipitation. Overall, the simulated contemporary-climate events compared favorably with the PRISM events’ frequency and duration. The simulated event areas tended to be larger than the areas in the PRISM events, suggesting that the effective resolution of the simulations is greater than 25 km. Event areas and durations change little going from contemporary to scenario climate. The short-term events increase in frequency by an amount commensurate with the increase in mean precipitation simulated for the basis. However, the extended-term events showed little change in frequency, despite the average precipitation increase. Roughly half the extended-period events overlapped with at least one short-term event in both the observations and the simulations. Extended-period events that overlap a short-term event generally have larger areas and longer durations compared to their counterparts with no overlapping short-term events. Understanding the climate dynamics yielding the two types of extended-period events could be useful for assessing future changes in the Missouri River Basin’s heavy precipitation events and their impact.

Fisel, Brandon J.↗

Structural Analysis of Pyrolytic Graphite Optics for the HiPEP Ion Thruster

The long lifetime requirements of interplanetary exploration missions is driving the need to develop long-life components for the electric propulsion thrusters that are being targeted for these missions. One of the primary life-limiting components of ion thrusters are the optics, which are continuously eroded during the operation of the thruster. Pyrolytic graphite optics are being considered for the High Power Electric Propulsion (HiPEP) ion thruster because of their very high resistance to erosion. This paper describes the structural analysis of the HiPEP pyrolytic graphite. A description of the development of the grid model, as well as the development of the effective properties and stress concentrations in the apertured area of the grids is included. An evaluation of the use of curved grids shows that the increased stiffness (compared to flat grids) prevents intergrid impact during launch, however, the residual stresses introduced by curving the grids pushes the resulting peak stresses beyond the critical stress. As a result, flat grids are recommended as the design solution. Thermally induced grid displacements during normal thruster operation are also presented.

Meckel, Nicole↗

Deploying Intra-hour Uncertainty Analysis Tools to ABB’s GridView - CRADA 445

The quickly-changing generation resource mix in the US grid, with large additions of variable resources, retirements of traditional thermal generation, distributed generation and demand response, are creating new challenges on the traditional operation of both the generation and transmission systems. The ability to perform intra-hour high fidelity production cost modeling (PCM) is needed to allow grid operators and grid planners to integrate high penetration (more than 50%) of variable energy resources, and to make prompt well informed decisions in market operations and planning. In the last decade, PNNL has developed several stand-alone tools to enable grid operators and planners to understand the impact of high variable generation on their systems. These tools have been used is studies such as: (1) Evaluation the benefits of WECC balancing authorities coordination under high variable generation penetration , (2) Benefits of Energy Imbalance Market in the North West Power Pool and (3) Duke Energy and NV Energy solar integration studies. ABB’s GridView is a widely used commercial PCM tool. It is the tool used by WECC and their stakeholders to develop the WECC PCM planning model on bi-annual basis. This proposal is focused on the integrating of PNNL intra-hour uncertainty analysis tools to GridView.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating the impact of wildfire smoke on solar photovoltaic production

There are growing needs to understand how extreme weather events impact the electrical grid. Renewable energy sources such as solar photovoltaics are expanding in use to help sustainably meet electricity demands. Wildfires and, notably, the widespread smoke resulting from them, are one such extreme event that can impair the performance of solar photovoltaics. However, isolating the impact that smoke has on photovoltaic energy production, separate from ambient conditions, can be difficult. In this work, we seek to understand and quantify the impacts of wildfire smoke on solar photovoltaic production within the Western United States. Our analysis focuses on the construction of a random forest regression model to predict overall solar photovoltaic production. The model is used to separate and quantify the impacts of wildfire smoke in particular. To do so, we fuse historical weather, solar photovoltaic energy production, and PM2.5 particulate matter (primary smoke pollutant) data to train and test our model. The additional weather data allows us to capture interactions between wildfire smoke and other ambient conditions, as well as to create a more powerful predictive model capable of better quantifying the impacts of wildfire smoke on its own. We find that solar PV energy production decreases 8.3% on average during high smoke days at PV sites as compared to similar conditions without smoke present. Finally, this work allows us to improve our understanding of the potential impact on photovoltaic-based energy production estimates due to wildfire events and can help inform grid and operational planning as solar photovoltaic penetration levels continue to grow.

14 SOLAR ENERGY↗

Depot-Based Vehicle Data for National Analysis of Medium- and Heavy-Duty Electric Vehicle Charging

Medium- and heavy-duty vehicles (MHDVs) are a major source of greenhouse gases and local criteria air pollutants. Electrifying MHDVs may reduce these harmful emissions, which disproportionately impact disadvantaged communities. Due to their relatively high per-vehicle energy needs, consistent fleet operations, and frequent colocation of multiple vehicles at depots, MHDVs may have more spatially and temporally concentrated charging demands than light-duty passenger electric vehicles. That charging concentration means their electrification may require careful advance planning and coordination to manage potential impacts to the electrical grid via charge management or infrastructure upgrades. However, MHDV duty cycles and parking schedules are highly variable across vocations of operation, and there is a shortage of nationally representative, vocationally diverse public data describing typical MHDV operations. This report summarizes the methodology - designed with national representativeness in mind - used to create a new set of data describing typical daily driving distances, dwell durations, and normalized electric vehicle depot charging load curves for MHDVs. The dataset reflects the subset of MHDV operating patterns that may originate from a consistent depot each day and rely on the same depot for charging. In addition to trucks with depot-centric vocational patterns, the data describes operations of transit buses and school buses, each with a depot-centric focus. The dataset is available to the public and suitable for national analysis. It can inform research, infrastructure planning, and policymaking regarding the electrification of MHDVs.

33 ADVANCED PROPULSION SYSTEMS↗

A Cross-Domain Optimization Framework of PMU and Communication Placement for Multidomain Resiliency and Cost Reduction

Phasor measurement units (PMUs) play a crucial role in real-time monitoring and control of power grids. They rely on a communication network to transfer measurement data to the phasor data concentrator (PDC) for further processing and analysis. In this paper, a resilient cross-domain PMU and communication link placement method for minimizing the overall installation cost of the wide-area measurement system (WAMS) is proposed. Here, the main idea is to break down the barrier between the power grid domain and the communication domain, and consider the impact of one when design the other. The PMU placement in the power grid domain takes into account the cost of communication links by generating multiple solutions with equally minimum PMU costs for communication link placement evaluation. On the other hand, the communication link placement problem reduces the cost by customizing the routing policies based on the different roles of PMUs in grid observability. The proposed WAMS design is capable of withstanding any single component failure in the power domain (PMU failure or power branch failure) or in the communication domain (communication link failure or PDC failure). Numerical study on the IEEE 57-bus system reveals that the developed cross-domain optimization framework can significantly reduce the overall installation cost of WAMS while attaining multi-domain resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of LOCA2 and STAR-ESDM Statistically Downscaled Products

The National Climate Assessment (NCA) is the preeminent national report examining current and future risks posed by climate change. Countless agencies, policymakers, stakeholders and other end-users rely upon guidance from the NCA to plan for an uncertain future. These groups all depend on modern curated data, provided alongside the NCA, to quantify the impact of climate change on metrics of relevance for their decision processes. In its fifth iteration (NCA5), two statistically downscaled ensemble products, each providing data at grid spacing of approximately 5km over the contiguous United States, were selected to accompany the report. These include LOCalized Analogs version 2 (LOCA2) and Seasonal Trends and Analysis of Residuals Empirical-Statistical Downscaling Model (STAR-ESDM). Both data products are produced through a process known as statistical downscaling, where relatively coarse Global Climate Model (GCM) data is refined to locally relevant scales through the application of scientifically-supported empirical and algorithmic relationships. In support of the NCA effort, this report provides an independent validation of these two products against historical observations, with a focus on precipitation and near-surface temperature variables. Based on the results of this validation, several recommendations are provided related to the use of these data products. The structure of this report is as follows: In section 2, we review three gridded observational products that are used as part of our intercomparison. In section 3, we describe the two statistical downscaling techniques and their corresponding datasets that are the focus of this study. In section 4, the methodology we employ for validation is described. Section 5 provides results of the validation, which in turn motivate our recommendations on the use of these data products. A brief summary is provided in section 6.

54 ENVIRONMENTAL SCIENCES↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗

Airport Ground Support Equipment Analysis

Ground support equipment (GSE) plays a critical role in providing services to aircraft at arrival and departure gates, ensuring smooth and efficient airport operations. As the airline industry seeks to reduce costs and expand energy options, electric GSE (eGSE) is emerging as a promising solution. This project examines the integration of eGSE into airport operations, addressing key considerations such as vehicle deployment, charging infrastructure, and grid impacts. We developed a flexible, bottom-up modeling framework to evaluate energy demands and infrastructure requirements across more than 300 U.S. airports, providing actionable insights to support electrification planning and implementation. The study focuses on eight major types of GSE with commercially available electric counterparts: aircraft tractors, ground power units, baggage tractors, belt loaders, cargo loaders, catering trucks, lavatory trucks, and water trucks. Project results include annual charging load profiles, total energy consumption, and the charger and fleet requirements for each airport.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗