Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “functionally graded material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Dielectric and ferroelectric response of compositionally graded bilayer and trilayer composites of BaTiO{sub 3} and 0.975BaTiO{sub 3}-0.025Ba(Cu{sub 1/3}Nb{sub 2/3})O{sub 3}

In this paper, we report the dielectric and ferroelectric response of compositionally graded bilayer and trilayer composites consisting of BaTiO{sub 3} (BT) and 0.975BaTiO{sub 3}-0.025Ba(Cu{sub 1/3}Nb{sub 2/3})O{sub 3} (BTBCN). Two types of graded bilayer samples were synthesized, one with same thickness of BT and BTBCN while other with different layer thicknesses. The graded trilayer sample consisted of BT layer sandwiched between two BTBCN layers of equal thickness. Scanning electron microscopy and transmission electron microscopy images showed a sharp interface with needle-shape domains across the interface. The domain size on BT side was found to be larger than that on BTBCN side. The temperature dependence of dielectric response for all composite systems was found to exhibit shifting in characteristic Curie peak compared to constituent material which was associated to coupling between layers. Moreover, the differences in grain size, tetragonality, domain mobility of each layer was found to perturb the electrical response of composite. The polarization mismatch between uncoupled BT and BTBCN established internal electric field in composite specimen and defined new polarization states in each layer by perturbing free energy functional of the composite specimen. Dynamic hysteresis behaviors and power-law scaling relations of all specimens were determined from polarization-electric field hysteresis loop measurements as a function of frequency. All systems were found to exhibit similar dynamic scaling relationships. Hysteresis area <A>, P{sub r}, and E{sub C} decreased with increasing frequency due to delayed response but increased with increasing applied electric field due to enhancement of driving force. Trilayer system was found to exhibit strong internal-bias field and double hysteresis behavior. The coupling effect resulting due to polarization mismatch between layers had substantial influence on the dynamic hysteresis behavior and power-law scaling relations.

36 MATERIALS SCIENCE↗

Development of Monitoring Techniques for Laser Powder Bed Additive Manufacturing of Metal Structures (Progress Report)

The Transformational Challenge Reactor (TCR) program is leveraging additive manufacturing (AM) technologies to fabricate nuclear grade components to be assembled into a fully functional microreactor core. Compared to traditional manufacturing technologies, additive manufacturing technologies allow (1) observation of the manufacturing process at a much higher resolution in real time using in situ monitoring technologies to capture the sensor signature that scientifically describes each event occurring over time and space, and (2) validation of the manufacturing process quality using domain-informed data analytics techniques as a potential qualification and certification methodology for the final component. This report provides an update on the program work on laser powder bed fusion in-situ process monitoring and associated data analytics results. Examples are provided to illustrate the progress. Elements of the Digital Thread and data management are discussed in the main document, and an extensive supplemental material section is provided detailing the Digital Platform, as well as its implementation and components. In conclusion the path forward for the next fiscal year is discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Phase II Trial of Radiosurgery to Magnetic Resonance Spectroscopy-Defined High-Risk Tumor Volumes in Patients With Glioblastoma Multiforme

Purpose: To determine the efficacy of a Gamma Knife stereotactic radiosurgery (SRS) boost to areas of high risk determined by magnetic resonance spectroscopy (MRS) functional imaging in addition to standard radiotherapy for patients with glioblastoma (GBM). Methods and Materials: Thirty-five patients in this prospective Phase II trial underwent surgical resection or biopsy for a GBM followed by SRS directed toward areas of MRS-determined high biological activity within 2 cm of the postoperative enhancing surgical bed. The MRS regions were determined by identifying those voxels within the postoperative T2 magnetic resonance imaging volume that contained an elevated choline/N-acetylaspartate ratio in excess of 2:1. These voxels were marked, digitally fused with the SRS planning magnetic resonance image, targeted with an 8-mm isocenter per voxel, and treated using Radiation Therapy Oncology Group SRS dose guidelines. All patients then received conformal radiotherapy to a total dose of 60 Gy in 2-Gy daily fractions. The primary endpoint was overall survival. Results: The median survival for the entire cohort was 15.8 months. With 75% of recursive partitioning analysis (RPA) Class 3 patients still alive 18 months after treatment, the median survival for RPA Class 3 has not yet been reached. The median survivals for RPA Class 4, 5, and 6 patients were 18.7, 12.5, and 3.9 months, respectively, compared with Radiation Therapy Oncology Group radiotherapy-alone historical control survivals of 11.1, 8.9, and 4.6 months. For the 16 of 35 patients who received concurrent temozolomide in addition to protocol radiotherapeutic treatment, the median survival was 20.8 months, compared with European Organization for Research and Treatment of Cancer historical controls of 14.6 months using radiotherapy and temozolomide. Grade 3/4 toxicities possibly attributable to treatment were 11%. Conclusions: This represents the first prospective trial using selective MRS-targeted functional SRS combined with radiotherapy for patients with GBM. This treatment is feasible, with acceptable toxicity and patient survivals higher than in historical controls. This study can form the basis for a multicenter, randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrocatalytic Hydrogenation of Biomass-Derived Organics: A review

Sustainable energy generation calls for a shift away from centralized, high-temperature, energy-intensive processes to decentralized, low-temperature conversions that can be powered by electricity produced from renewable sources. Electrocatalytic conversion of biomass-derived feedstocks would allow carbon recycling of distributed, energy-poor resources in the absence of sinks and sources of high-grade heat. Selective, efficient electrocatalysts that operate at low temperatures are needed for electrocatalytic hydrogenation (ECH) to upgrade the feedstocks. For effective generation of energy-dense chemicals and fuels, two design criteria must be met: (i) a high H:C ratio via ECH to allow for high-quality fuels and blends, and (ii) a lower O:C ratio in the target molecules via electrochemical decarboxylation/deoxygenation to improve the stability of fuels and chemicals. The goal of this review is to determine whether the following questions have been sufficiently answered in open literature, and if not, what additional information is required: (1) What organic functionalities are accessible for electrocatalytic hydrogenation under a set of reaction conditions? How do substitutions and functionalities impact the activity and selectivity of ECH? (2) What material properties cause an electrocatalyst to be active for ECH? Can general trends in ECH be formulated based on the type of electrocatalyst? (3) What is the impact of reaction (electrolyte concentration, pH, operating potential) and reactor type conditions?

Catalysts, redox reactions, hydrocarbons, Aromatic↗

Clinical Outcomes of Postmastectomy Radiation Therapy After Immediate Breast Reconstruction

Purpose: To determine the long-term complication rates and cosmetic results for patients undergoing postmastectomy radiation therapy (PMRT) after immediate reconstruction (IR). Methods and Materials: Between January 1998 and December 2005, 92 patients underwent modified radical mastectomy, IR, and PMRT in our practice. A total of 69 patients underwent tissue expander and implant reconstruction (TE/I), and 23 underwent autologous tissue reconstruction (ATR). Follow-up regarding complications and cosmesis was obtained for all 92 patients. Complications were scored as follows: Grade 1, no discomfort; Grade 2, discomfort affecting activities of daily living; Grade 3, surgical intervention or intravenous antibiotics required; and Grade 4, removal or replacement of the reconstruction. Cosmesis was rated as either acceptable or unacceptable to the patient. Both complications and cosmesis were correlated with treatment- and patient-related factors. Results: Median follow-up for all patients was 38 months. The overall rate of severe complications (Grade 3-4) was 25%. The overall rate of poor functional results (Grade 2-4) was 43.4%. When analyzed as a function of type of reconstruction, the rate of Grade 3 to 4 complications was 33.3% for TE/I vs. 0% for ATR (p = 0.001). The rate of Grade 2 to 4 complications was 55% for TE/I vs. 8.7% for ATR (p < 0.001). Acceptable cosmesis was reported in 51% of TE/I patients vs. 82.6% of ATR patients (p = 0.007). No other treatment or patient-related factors had a significant impact on either complications or cosmesis. Conclusion: In patients undergoing PMRT after IR, ATR is associated with fewer long-term complications and better cosmetic results than TE/I.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiotherapy for Patients With Unresectable Primary Hepatocellular Carcinoma: Dose-Volumetric Parameters Predicting the Hepatic Complication

Purpose: To identify the parameters that predict hepatic toxicity and deterioration of hepatic function. Materials and Methods: A total of 47 patients with small unresectable primary hepatocellular carcinoma received hypofractionated stereotactic body radiotherapy (SBRT) using the CyberKnife. Of those, 36 patients received no other local treatments that could influence hepatic toxicity at least for 3 months after the completion of SBRT. The gross tumor volume (GTV) was 18.3 {+-} 15.9 cm{sup 3} (range, 3.0-81.3 cm{sup 3}), and the total dose administered was 30-39 Gy (median, 36 Gy). To assess the deterioration of hepatic function, we evaluated the presence or absence of the progression of Child-Pugh class (CP class). To identify the parameters of predicting the radiation-induced hepatic toxicity and deterioration of the hepatic function, several clinical and dose-volumetric parameters were evaluated. Results: Of 36 patients, 12 (33%) developed Grade 2 or higher hepatic toxicity and 4 (11%) developed progression of CP class. The multivariate analysis showed that the only significant parameter associated with the progression of CP class was the total liver volume receiving a dose less than 18 Gy (<18 Gy). Conclusions: The progression of CP class after SBRT limits other additional local treatments and also reflects the deterioration of hepatic function. Therefore, it would be important to note that the presence or absence of the progression of CP class is a dose-limiting factor. The total liver volume receiving <18 Gy should be greater than 800 cm{sup 3} to reduce the risk of the deterioration of hepatic function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Severe Acute and Late Toxicities in Patients With Localized Head-and-Neck Cancer Treated With Radiation Therapy

Purpose: Radiation therapy (RT) causes acute and late toxicities that affect various organs and functions. In a large cohort of patients treated with RT for localized head and neck cancer (HNC), we prospectively assessed the occurrence of RT-induced acute and late toxicities and identified characteristics that predicted these toxicities. Methods and Materials: We conducted a randomized trial among 540 patients treated with RT for localized HNC to assess whether vitamin E supplementation could improve disease outcomes. Adverse effects of RT were assessed using the Radiation Therapy Oncology Group Acute Radiation Morbidity Criteria during RT and one month after RT, and the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Radiation Morbidity Scoring Scheme at six and 12 months after RT. The most severe adverse effect among the organs/tissues was selected as an overall measure of either acute or late toxicity. Grade 3 and 4 toxicities were considered as severe. Stepwise multivariate logistic regression models were used to identify all independent predictors (p < 0.05) of acute or late toxicity and to estimate odds ratios (OR) for severe toxicity with their 95% confidence intervals (CI). Results: Grade 3 or 4 toxicity was observed in 23% and 4% of patients, respectively, for acute and late toxicity. Four independent predictors of severe acute toxicity were identified: sex (female vs. male: OR = 1.72, 95% confidence interval [CI]: 1.06-2.80), Karnofsky Performance Status (OR = 0.67 for a 10-point increment, 95% CI: 0.52-0.88), body mass index (above 25 vs. below: OR = 1.88, 95% CI: 1.22-2.90), TNM stage (Stage II vs. I: OR = 1.91, 95% CI: 1.25-2.92). Two independent predictors were found for severe late toxicity: female sex (OR = 3.96, 95% CI: 1.41-11.08) and weight loss during RT (OR = 1.26 for a 1 kg increment, 95% CI: 1.12-1.41). Conclusions: Knowledge of these predictors easily collected in a clinical setting could help tailoring therapies to reduce toxicities among patients treated with RT for HNC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of graphite particles by sliding abrasion and their characterization

Characterization of graphite particles (dust) produced by abrasion that would occur in a pebble bed reactor is of interest for reasons of safety, operation, and maintenance. To better understand this abrasion and particle generation, we have built a test apparatus to produce particles by sliding abrasion in a 1% to 5% relative humidity air environment. We have used a commercial-grade graphite in our experiments and have generated size distributions for the abraded particles. We have also fit lognormal functions to those size distributions (for use in computer codes); determined particle shapes; measured temperature and humidity during the tests; measured and calculated wear rates; and measured the surface roughness of both pretest and posttest samples, particle surface areas, pore volumes, and pore volume distributions of particles produced during abrasion of graphite surfaces under different loadings and sliding speeds. The experiments showed that as loading (analogous to pebble depth in the reactor) and sliding speed increase, so do the wear rates and numbers of particles produced, while surface roughness decreases, increases, and then decreases. Brunauer-Emmett-Teller measurements show that abrasion increases surface area from 0.583 m 2 /g in the bulk material to 555 m 2 /g in material abraded at high loading and high sliding speed. Wear rates range from 0.005 to 0.991 g/m per contact site. As a result, the size of the particles observed was <4000 nm. Finally, in all, our research shows that pebble abrasion is a complex process that is not constant during operation and thus should be considered for future work.

36 MATERIALS SCIENCE↗

Radiation Therapy for Treatment of Pigmented Villonodular Synovitis: Results of a National Patterns of Care Study

Purpose: The German Cooperative Group on Radiotherapy in Benign Diseases (GCG-BD) conducted a pattern-of-care study (PCS) to analyze the radiation therapy (RT) practice for pigmented villonodular synovitis (PVNS). Methods and Materials: In 2007, a structured questionnaire to assess the number of patients, the pretreatments, the RT indication, technique, target volume concepts, outcome data, and possible early or late toxicity was circulated to 227 institutions. Results: Until August 2008, a response was available from 189 institutions (83.2 %), of whom 19 (10.0 %) experienced RT for PVNS. Complete clinical information was available for 41 patients from 14 RT departments. Thirty patients (73.2 %) received postsurgical RT because of primary incomplete resection, 11 patients (26.8 %) as an adjunct after complete resections of recurrences or unclear resection status. The total doses ranged from 30 to 50 Gy (median, 36 Gy), the median single dose was 2.0 Gy. Local control was achieved 95.1%, and 82.9% had no or only slight functional impairment. The early and late toxicity was mild ({<=}RTOG Grade II). Conclusions: Radiation therapy is a safe and effective treatment for PVNS in the postoperative setting after incomplete resection, and also as a salvage option for treatment of recurrences it provides a high rate of local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron multiplication error in TRU waste measurements

Total Measurement Uncertainty (TMU) in neutron assays of transuranic waste (TRU) are comprised of several components including counting statistics, matrix and source distribution, calibration inaccuracy, background effects, and neutron multiplication error. While a minor component for low plutonium masses, neutron multiplication error is often the major contributor to the TMU for items containing more than 140 g of weapons grade plutonium. Neutron multiplication arises when neutrons from spontaneous fission and other nuclear events induce fissions in other fissile isotopes in the waste, thereby multiplying the overall coincidence neutron response in passive neutron measurements. Since passive neutron counters cannot differentiate between spontaneous and induced fission neutrons, multiplication can lead to positive bias in the measurements. Although neutron multiplication can only result in a positive bias, it has, for the purpose of mathematical simplicity, generally been treated as an error that can lead to either a positive or negative result in the TMU. While the factors that contribute to neutron multiplication include the total mass of fissile nuclides, the presence of moderating material in the matrix, the concentration and geometry of the fissile sources, and other factors; measurement uncertainty is generally determined as a function of the fissile mass in most TMU software calculations because this is the only quantity determined by the passive neutron measurement. Neutron multiplication error has a particularly pernicious consequence for TRU waste analysis because the measured Fissile Gram Equivalent (FGE) plus twice the TMU error must be less than 200 for TRU waste packaged in 55-gal drums and less than 325 for boxed waste. For this reason, large errors due to neutron multiplication can lead to increased rejections of TRU waste containers. This report will attempt to better define the error term due to neutron multiplication and arrive at values that are more realistic and accurate. To do so, measurements of standards and waste drums were performed with High Efficiency Neutron Counters (HENC) located at Los Alamos National Laboratory (LANL). The data were analyzed for multiplication effects and new estimates of the multiplication error were computed. A concluding section will present alternatives for reducing the number of rejections of TRU waste containers due to neutron multiplication error.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predictive Factors of Late Radiation Fibrosis: A Prospective Study in Non-Small Cell Lung Cancer

Purpose: To determine predictive factors of late radiation fibrosis (RF) after conformal radiotherapy (3D-RT) in non-small cell lung cancer (NSCLC). Methods and Materials: Ninety-six patients with Stage IA-IIIB NSCLC were included in a prospective trial. Clinical evaluation, chest X-ray, and pulmonary functional tests including diffusion parameters were performed before and 6 months after radiotherapy. An independent panel of experts prospectively analyzed RF, using Late Effects in Normal Tissues-Subjective, Objective, Management and Analytic scales classification. Logistic regression analysis was performed to identify relationships between clinical, functional, or treatment parameters and incidence of RF. Variations of circulating serum levels of pro-inflammatory (interleukin-6, tumor necrosis factor alpha, tumor growth factor beta1) and anti-inflammatory (interleukin-10) cytokines during 3D-RT were examined to identify correlations with RF. Results: Of the 96 patients included, 72 were evaluable for RF at 6 months. Thirty-seven (51.4%) developed RF (Grade >=1), including six severe RF (Grades 2-3; 8.3%). In univariate analysis, only poor Karnofsky Performance Status and previous acute radiation pneumonitis were associated with RF (p < 0.05). Dosimetric factors (mean lung dose, percentage of lung volume receiving more than 10, 20, 30, 40, and 50 Gy) were highly correlated with RF (p < 0.001). In multivariate analysis, previous acute radiation pneumonitis and dosimetric parameters were significantly correlated with RF occurrence. It was not significantly correlated either with cytokines at baseline or with their variation during 3D-RT. Conclusions: This study confirms the importance of dosimetric parameters to limit the risk of RF. Contrary to acute radiation pneumonitis, RF was not correlated to cytokine variations during 3D-RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Evaluation of Cavitation-Erosion Resistance of Ti-Alloys in Mercury for the Spallation Neutron Source

A number of Ti-based alloys in both the mill-annealed and 20% cold-worked conditions were subjected to sonication conditions in Hg using a vibratory horn to assess relative cavitation-erosion resistance. Weight loss as a function of exposure time was roughly proportional to hardness for all alloys/conditions examined, with Ti-6Al-4V (Ti-Grade 5) and Ti-6Al-2Sn-4Zr-2Mo yielding the best resistance to cavitation-erosion as evidenced by low weight losses and little or no tendency to form pits on the exposed surface. Unalloyed Ti (Ti-Grade 4) and Ti-0.12Pd (Ti-Grade 7) exhibited greater weight losses by a factor or about two and about five, respectively, with Ti-0.12Pd particularly prone to pitting development. The mean erosion rates of the best two Ti-alloys examined here were about a factor of three higher than identically tested 316LN stainless steel following a low temperature carburizing treatment, but this difference is considered minor given that the rate for both materials is very low/manageable and represents a through-thickness property for the Ti-alloys. A nitriding surface treatment was also evaluated as a potential method to further increase the cavitation-erosion resistance of these alloys in Hg, but the selected treatment proved largely ineffective. Recommendations for further work to evaluate the efficacy of Ti-based alloys for use in high-powered targets for the Spallation Neutron Source are given.

36 MATERIALS SCIENCE↗

Creep and microstructural processes in a low-alloy 2.25%Cr1.6%W steel (ASTM Grade 23)

A low-alloy 2.25%Cr1%Mo steel (ASTM Grade 22) has been greatly improved by the substitution of almost all of the 1%Mo by 1.6%W. The improved material has been standardized as P/T23 steel (Fe–2.25Cr–1.6W–0.25V–0.05Nb–0.07C). The present investigation was conducted on T23 steel in an effort to obtain a more complete description and understanding of the role of the microstructural evolution and deformation processes in high-temperature creep. Constant load tensile creep tests were carried out in an argon atmosphere in the temperature range 500–650 °C at stresses ranging from 50 to 400 MPa. It was found that the diffusion in the matrix lattice is the creep-rate controlling process. The results of an extensive transmission electron microscopy (TEM) analysis programme to investigate microstructure evolution as a function of temperature are described and compared with the thermodynamic calculations using the software package Thermo-Calc. The significant creep-strength drop of T23 steel after long-term creep exposures can be explained by the decrease in dislocation hardening, precipitation hardening and solid solution hardening due to the instability of the microstructure at high temperature. - Highlights: • The constant load creep tests of T23 steel were carried out at 500–650 °C. • The stress exponents of the creep rate correspond to power law (dislocation) creep. • Diffusion in the matrix lattice is the creep-rate controlling process. • The microstructure instability is the main creep degradation process in T23 steel.

36 MATERIALS SCIENCE↗

Elucidation of Structure and Physical Properties of Pyrolytic Sugar Oligomers Derived from Cellulose Depolymerization/Dehydration Reactions: A Density Functional Theory Study

Fast pyrolysis of lignocellulosic materials is a promising research area to produce renewable fuels and chemicals. Dehydration is known to be among the most important reaction families during cellulose pyrolysis; water is the most important product. Together with water, dehydration reactions also form a range of poorly known oligomer species of varying molecular sizes, often collected as part of bio-oil water-soluble (WS) fraction. In this work, we used electronic structure calculations to evaluate the relative thermodynamic stabilities of several oligomer species resulting from up to three consecutive dehydration events from cellulose depolymerization intermediates. A library of the thermodynamically favored candidate molecular structures was compiled. Results revealed that most of the water molecules are eliminated from the non-reducing end, forming thermodynamically more stable conjugated compounds. This is consistent with results reported by other researchers in literature where dehydration reactions occur preferably at the non-reducing ends of oligomers. The physical-chemical properties of the proposed structures were estimated using quantitative structure-property relationships (QSPRs) and quantitative property-property relationships (QPPRs). The anhydro-sugars derived from cellulose are often blamed for coke formation during bio-oil hydrotreatment. Understanding their chemical structure could help to develop rational strategies to mitigate coke formation. Furthermore, the thermo-physical properties reported (boiling point, melting point, Gibb’s free energy of formation, enthalpy of formation, and solubility parameters among others) are also fundamental to conducting first principle engineering calculations to design and analyze new pyrolysis reactors and bio-oil up-grading units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validity of the Graded Prognostic Assessment-Derived Index to Predict Brain-Metastatic Patients' Survival After Gamma Knife Radiosurgery

Purpose: To appraise whether the graded prognostic assessment (GPA)-derived index is valid for selecting patients with brain metastases for Gamma Knife (GK) radiosurgery. Methods and Materials: A total of 56 consecutive patients in recursive partioning analysis (RPA) Class I (n = 19, 34%) and II (n = 37, 66%) formed the basis of this retrospective study. Their mean age was of 57 years with mean Karnofsky performance score of 77. Primary cancers stemmed mainly from the lungs (59%). A total of 45 patients (80%) harbored multiple tumors. The mean clinical follow-up period was 9 months. Results: Kaplan-Meier analysis demonstrated that the overall median survival time (MST) for the whole series was 11.5 months: 16.5 vs. 6.5 months for RPA class I and II (p = 0.017). Multivariate Cox analysis revealed that female patients and a pre-GK good functional state were favorable prognostic factors. The favorable MST was in patients with a GPA score of 3 to 4 (17 months) followed by a GPA score of 2 to 2.5 (11 months) and GPA score 0 to 1.5 (6.5 months), but without statistical differences (p = 0.413) in between. A modified index (MGPA) is proposed with gender as a cofactor, then there existed a distinct survival differences (p = 0.028) between patients with an MGPA score of 3.5 to 5 (15 months) and with an MGPA score of 0 to 3 (7 months). In addition, the original GPA index failed to imply the difference of MST in patients with lung origin. Conclusions: The GPA-derived index is not applicable to our set of patients for comparing their survival after GK radiosurgery. The gender of the patients is a suggested cofactor to further refine the greater prognostic accuracy of the GPA index.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Instrument for spatially resolved, temperature-dependent electrochemical impedance spectroscopy of thin films under locally controlled atmosphere

We demonstrate an instrument for spatially resolved measurements (mapping) of electrochemical impedance under various temperatures and gas environments. Automated measurements are controlled by a custom LabVIEW program, which manages probe motion, sample motion, temperature ramps, and potentiostat functions. Sample and probe positioning is provided by stepper motors. Dry or hydrated atmospheres (air or nitrogen) are available. The configurable heater reaches temperatures up to 500 °C, although the temperature at the sample surface is moderated by the gas flow rate. The local gas environment is controlled by directing flow toward the sample via a glass enclosure that surrounds the gold wire probe. Software and hardware selection and design are discussed. Reproducibility and accuracy are quantified on a Ba(Zr,Y)O 3-δ proton-conducting electrolyte thin film synthesized by pulsed laser deposition. The mapping feature of the instrument is demonstrated on a compositionally graded array of electrocatalytically active Ba(Co,Fe,Zr,Y)O 3-δ thin film microelectrodes. The resulting data indicate that this method proficiently maps property trends in these materials, thus demonstrating the reliability and usefulness of this method for investigating electrochemically active thin films.

47 OTHER INSTRUMENTATION↗

Microstructure Sensitive Design and Processing in Solid Oxide Electrolyzer Cell

The aim of this study was to develop and inexpensive manufacturing process for deposition of functionally graded thin films of LSM oxides with porosity graded microstructures for use as IT-SOFCs cathode. The spray pyrolysis method was chosen as a low-temperature processing technique for deposition of porous LSM films onto dense YXZ substrates. The effort was directed toward the optimization of the processing conditions for deposition of high quality LSM films with variety of morphologies in the range of dense to porous microstructures. Results of optimization studies of spray parameters revealed that the substrate surface temperature is the most critical parameter influencing the roughness and morphology, porosity, cracking and crystallinity of the film.

30 DIRECT ENERGY CONVERSION↗

Capecitabine Initially Concomitant to Radiotherapy Then Perioperatively Administered in Locally Advanced Rectal Cancer

Purpose: To evaluate the impact of neoadjuvant capecitabine, concomitant to radiotherapy, followed by capecitabine monotherapy, in operable locally advanced rectal cancer (LARC) by measuring pathologic response and conservative surgery rate, toxicity profile, and disease-free survival (DFS). Methods and Materials: From October 2002 to July 2006, a total of 51 patients affected by LARC (T3-T4 or any node positive tumor), received capecitabine (825 mg/m{sup 2}, orally, twice daily continuously) concomitant to radiotherapy on the pelvis (50.4 Gy/ 28 fractions), followed by two cycles of capecitabine (1,250 mg/m{sup 2}, orally, twice daily, 14 days on 7 days off) up until 2 weeks before surgery. Tailored adjuvant systemic treatment was discussed according to pathologic stage. Results: Of 51 patients, (median age 61 years, range 38-82 years; 19 women and 32 men; ECOG performance status 0/1/2: 46/4/1), 50 were evaluable for response: 18% complete pathologic remission; 12% T-downstaging, and 30% N-downstaging. One patient died before surgery from mesenteric stroke. Grade 3 acute toxicities were 2% diarrhea, 8% dermatitis, 2% liver function test elevation, and 2% hand-foot syndrome. Sphincter preservation rates for tumors {<=}6 cm from the anal verge were 62% and 80% for the whole population. Median follow up was 43.0 months (range 0.8-68.6 months). Five-years DFS was 85.4% (95% CI = 75.3-95.4%). Conclusions: Based on our study results, we conclude that this regimen is well tolerated and active and compares favorably with existing capecitabine-based approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗