Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

PRECISE THz MEASUREMENTS OF HCO{sup +}, N{sub 2}H{sup +}, AND CF{sup +} FOR ASTROPHYSICAL OBSERVATIONS

Ground-state rotational spectra of HCO{sup +}, N{sub 2}H{sup +}, and CF{sup +} (both {sup 12}C- and {sup 13}C-containing isotopologues) have been recorded in the 1.0-1.6 THz frequency range. Present measurements allowed us to improve the spectroscopic parameters, which in turn enabled the prediction of rotational transitions up to 2.0-2.5 THz with good accuracy. We therefore consider the present results to be of great value in view of the extended spectral coverage made available by the Herschel Space Observatory, Stratospheric Observatory for Infrared Astronomy, and the Atacama Large Millimeter Array. Furthermore, we re-investigated the ground-state rotational spectrum of N{sub 2}H{sup +} in the 93-750 GHz frequency range, thus addressing the open issue of the frequency of the J = 1 <- 0 transition as well as resolving the hyperfine structure of the J + 1 <- J transitions with J = 1, 2, and 3 for the first time.

74 ATOMIC AND MOLECULAR PHYSICS↗

P and S wave responses of bacterial biopolymer formation in unconsolidated porous media

This study investigated the P and S wave responses and permeability reduction during bacterial biopolymer formation in unconsolidated porous media. Column experiments with fine sands, where the model bacteria Leuconostoc mesenteroides were stimulated to produce insoluble biopolymer, were conducted while monitoring changes in permeability and P and S wave responses. The bacterial biopolymer reduced the permeability by more than 1 order of magnitude, occupying ~10% pore volume after 38 days of growth. This substantial reduction was attributed to the bacterial biopolymer with complex internal structures accumulated at pore throats. S wave velocity (V S ) increased by more than ~50% during biopolymer accumulation; this indicated that the bacterial biopolymer caused a certain level of stiffening effect on shear modulus of the unconsolidated sediment matrix at low confining stress conditions. Whereas replacing pore water by insoluble biopolymer was observed to cause minimal changes in P wave velocity (VP) due to the low elastic moduli of insoluble biopolymer. The spectral ratio analyses revealed that the biopolymer formation caused a ~50-80% increase in P wave attenuation (1/Q P ) at the both ultrasonic and subultrasonic frequency ranges, at hundreds of kHz and tens of kHz, respectively, and a ~50-60% increase in S wave attenuation (1/Q S ) in the frequency band of several kHz. Our results reveal that in situ biopolymer formation and the resulting permeability reduction can be effectively monitored by using P and S wave attenuation in the ultrasonic and subultrasonic frequency ranges. Finally, this suggests that field monitoring using seismic logging techniques, including time-lapse dipole sonic logging, may be possible.

58 GEOSCIENCES↗

Grid polarizers for infrared Fourier spectrometers

Infrared grid polarizers consisting of copper lines with a 3.6-micron grid constant on a 4-micron-thick Mylar polyester substrate have been prepared by the techniques of photolithography and sputter-etching. Their polarization properties have been measured and found to be suitable for use at infrared frequencies below 700/cm. The polarizers have been used to extend the useful frequency range of a Martin-Puplett polarizing interferometer designed for Fourier transform spectroscopy. The efficiency of the interferometer has been measured over a frequency range from 50 to 700/cm and compared to that of a conventional Michelson interferometer. The results are shown to be consistent with the measured properties of the polarizers. Methods are suggested for improving the efficiency of a Martin-Puplett interferometer which employs these polarizers.

Challener, W. A.↗

X-ray QPOs from the Ultra-luminous X-ray Source in M82: Evidence Against Beaming

We report the discovery with the European Photon Imaging Camera (EPIC) CCD cameras onboard XMM-Newton of a 54 mHz quasiperiodic oscillation (QPO) in the greater than 2 keV X-ray flux from the ultra-luminous X-ray source (ULX) X41.4+60 in the starburst galaxy M82. This is the first detection of a QPO in the X-ray flux from an extra-Galactic ULX, and confirms that the source is a compact object. The QPO is detected in the combined PN and MOS data at the approx. 6sigma level, and separately at lower significances in both the PN and MOS instruments. It had a centroid frequency of 54.3 +/- 0.9 mHz, a coherence Q is identical with nu(sub 0)/Delta nu(sub fwhm) is approx. 5, and an amplitude (rms) in the 2 - 10 keV band of 8.5%. Below about 0.2 Hz the power spectrum can be described by a power-law with index approx. 1, and integrated amplitude (rms) of 13.5%. The X-ray spectrum requires a curving continuum, with a disk-blackbody (diskbb) at T = 3.1 keV providing an acceptable, but not unique, fit. A broad Fe line centered at 6.55 keV is required in all fits, but the equivalent width (EW) of the line is sensitive to the choice of continuum model. There is no evidence of a reflection component. The implied bolometric luminosity is approx. 4 - 5 x 10(exp 40) ergs/s. Data from several archival Rossi X-ray Timing Explorer (RXTE) pointings at M82 also show evidence for QPOs in the 50 - 100 mHz frequency range. Several Galactic black hole candidates (BHCs), including GRS 1915+105, GRO J1655-40, and XTE 1550-564, show QPOs in the same frequency range as the 50 - 100 mHz QPOs in X41.4+60, which at first glance suggests a possible connection with such objects. However, strong, narrow QPOs provide solid evidence for disk emission, and thus present enormous theoretical difficulties for models which rely on either geometrically or relativistically beamed emission to account for the high X-ray luminosities. We discuss the implications of our findings for models of the ULX sources.

Strohmayer, Tod E.↗

Benefits of Spacecraft Level Vibration Testing

NASA-HDBK-7008 Spacecraft Level Dynamic Environments Testing discusses the approaches, benefits, dangers, and recommended practices for spacecraft level dynamic environments testing, including vibration testing. This paper discusses in additional detail the benefits and actual experiences of vibration testing spacecraft for NASA Goddard Space Flight Center (GSFC) and Jet Propulsion Laboratory (JPL) flight projects. JPL and GSFC have both similarities and differences in their spacecraft level vibration test approach: JPL uses a random vibration input and a frequency range usually starting at 5 Hz and extending to as high as 250 Hz. GSFC uses a sine sweep vibration input and a frequency range usually starting at 5 Hz and extending only to the limits of the coupled loads analysis (typically 50 to 60 Hz). However, both JPL and GSFC use force limiting to realistically notch spacecraft resonances and response (acceleration) limiting as necessary to protect spacecraft structure and hardware from exceeding design strength capabilities. Despite GSFC and JPL differences in spacecraft level vibration test approaches, both have uncovered a significant number of spacecraft design and workmanship anomalies in vibration tests. This paper will give an overview of JPL and GSFC spacecraft vibration testing approaches and provide a detailed description of spacecraft anomalies revealed.

Spacecraft Vibration Test↗

Radio Emissions Observed by Galileo near Io

The Galileo spacecraft observed spin modulation of radio wave emissions near Io in the frequency range from about 600 kHz to about 1.2 MHz. Assuming transverse EM radiation, we have used the modulation of the high-frequency sweep-frequency receiver signals of the electric dipole antenna over many spins to estimate the plane through the source. The emission has a range of frequencies close to the local upper hybrid frequency of the plasma near Io. We conclude that the emission may be associated with either the plasma torus or magnetic flux tubes in the wake of Io (the Alfven current system). We postulate this emission may be associated with a free-energy source such as density gradients, energetic plasma beams and/or an electron distribution with a temperature anisotropy. All of these free-energy sources are observed or expected in the torus near Io. The observations are the first in the hectometric frequency range that have a source associated with Io or in the Io torus.

Menietti, J. D.↗

Nonlinear analysis and vibro-impact characteristics of a shaft-bearing assembly

Here this study investigates the nonlinear frequency response of a shaft-bearing assembly with vibro-impacts occurring at the bearing clearances. The formation of nonlinear behavior as system parameters change is examined, along with the effects of asymmetries in the nominal, inherently symmetric system. The primary effect of increasing the forcing magnitude or decreasing the contact gap sizes is the formation of grazing-induced chaotic solution branches occurring over a wide frequency range near each system resonance. The system's nominal setup has very hard contact stiffness and shows no evidence of isolas or superharmonic resonances over the frequency ranges of interest. Moderate contact stiffnesses cause symmetry breaking and introduce superharmonic resonance branches of primary resonances. Even if some primary resonances are not present due to the system's inherent symmetry, their superharmonic resonances still manifest. Branches of quasiperiodic isolas (isolated resonance branches) are also discovered, along with a cloud of isolas near a high-frequency resonance. Parameter asymmetries are found to produce a few significant changes in behavior: asymmetric linear stiffness, contact stiffness, and gap size could affect the behavior of primary resonant frequencies and isolas.

42 ENGINEERING↗

HIGH DYNAMIC RANGE OBSERVATIONS OF SOLAR CORONAL TRANSIENTS AT LOW RADIO FREQUENCIES WITH A SPECTRO-CORRELATOR

A new antenna system with a digital spectro-correlator that provides high temporal, spectral, and amplitude resolutions has been commissioned at the Gauribidanur Observatory near Bangalore in India. Presently, it is used for observations of the solar coronal transients in the scarcely explored frequency range ≈30–15 MHz. The details of the antenna system, the associated receiver setup, and the initial observational results are reported. Some of the observed transients exhibited quasi-periodicity in their time profiles at discrete frequencies. Estimates of the associated magnetic field strength (B) indicate that B ≈ 0.06–1 G at a typical frequency such as 19.5 MHz.

79 ASTRONOMY AND ASTROPHYSICS↗

FREQUENCY-DEPENDENT DISPERSION MEASURES AND IMPLICATIONS FOR PULSAR TIMING

The dispersion measure (DM), the column density of free electrons to a pulsar, is shown to be frequency dependent because of multipath scattering from small-scale electron-density fluctuations. DMs vary between propagation paths whose transverse extent varies strongly with frequency, yielding arrival times that deviate from the high-frequency scaling expected for a cold, uniform, unmagnetized plasma (1/frequency{sup 2}). Scaling laws for thin phase screens are verified with simulations; extended media are also analyzed. The rms DM difference across an octave band near 1.5 GHz is ∼ 4 × 10{sup −5} pc cm{sup −3} for pulsars at ∼1 kpc distance. The corresponding arrival-time variations are a few to hundreds of nanoseconds for DM ≲ 30 pc cm{sup −3} but increase rapidly to microseconds or more for larger DMs and wider frequency ranges. Chromatic DMs introduce correlated noise into timing residuals with a power spectrum of “low pass” form. The correlation time is roughly the geometric mean of the refraction times for the highest and lowest radio frequencies used, ranging from days to years, depending on the pulsar. We discuss implications for methodologies that use large frequency separations or wide bandwidth receivers for timing measurements. Chromatic DMs are partially mitigable by including an additional chromatic term in arrival time models. Without mitigation, an additional term in the noise model for pulsar timing is implied. In combination with measurement errors from radiometer noise, an arbitrarily large increase in total frequency range (or bandwidth) will yield diminishing benefits and may be detrimental to overall timing precision.

79 ASTRONOMY AND ASTROPHYSICS↗

The damping of ocean surface waves by a monomolecular film measured by wave staffs and microwave radars

Open ocean and wave tank experiments were carried out with the aim of studying the damping of capillary and gravity waves by a monomolecular film. These films of biogenic origin influence air-sea interaction processes and thereby affect the use of remote sensing techniques in oceanography. Measurement was carried out by wave staffs, by a coherent X band microwave scatterometer mounted on a sea-based platform, and by an incoherent K band microwave scatterometer carried by an aircraft under moderate wind conditions. A wave attenuation of about 40-60% is observed in the frequency range between 3.2 and 16 Hz. Tank experiments show that a direct influence of oleyl alcohol surface films on wave damping is confined to frequencies equal to or greater than 2 Hz; a further indirect effect of films on the damping of ocean waves in the frequency range between 0.12 and 0.7 Hz (by modifying the wind input and wave-wave interaction mechanisms) is also indicated

Huehnerfuss, H.↗

Transition from Townsend to radio-frequency homogeneous dielectric barrier discharge in a roll-to-roll configuration

The aim of this paper is to better understand the transition from Townsend to radio-frequency homogeneous dielectric barrier discharge (DBD) at atmospheric pressure. The study is done in an Ar/NH{sub 3} Penning mixture for an electrode configuration adapted to roll-to-roll plasma surface treatment. The study was led in a frequency range running from 50 kHz up to 8.3 MHz leading to different DBD modes with a 1 mm gas gap: Glow (GDBD), Townsend (TDBD), and Radio-frequency (RF-DBD). In the frequency range between TDBD and RF-DBD, from 250 kHz to 2.3 MHz, additional discharges are observed outside the inter-electrode gas gap. Because each high voltage electrode are inside a dielectric barrel, these additional discharges occur on the side of the barrel where the gap is larger. They disappear when the RF-DBD mode is attained in the 1 mm inter-electrode gas gap, i.e., for frequencies equal or higher than 3 MHz. Fast imaging and optical emission spectroscopy show that the additional discharges are radio-frequency DBDs while the inter-electrode discharge is a TDBD. The RF-DBD discharge mode is attained when electrons drift becomes low enough compared to the voltage oscillation frequency to limit electron loss at the anode. To check that the additional discharges are due to a larger gas gap and a lower voltage amplitude, the TDBD/RF-DBD transition is investigated as a function of the gas gap and the applied voltage frequency and amplitude. Results show that the increase in the frequency at constant gas gap or in the gas gap at constant frequency allows to obtain RF-DBD instead of TDBD. At low frequency and large gap, the increase in the applied voltage allows RF-DBD/TDBD transition. As a consequence, an electrode configuration allowing different gap values is a solution to successively have different discharge modes with the same applied voltage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical study of the spectrum of broadband electrostatic noise in the magnetotail

A numerical study of the spectrum of broadband electrostatic noise (BEN) generated by ion beams in the plasma sheet boundary layer (PSBL) is presented, in which two cases are analyzed. The first case is concerned with a single hot-electron species. In the second case, a second population of cold electrons (arising from diffusion from the lobe into the PSBL) is introduced. The presence of the second electron component in the dispersion relation for generating BEN was found to significantly increase the upper frequency range of the unstable spectrum, enhancing the associated growth rates. It is shown that ion beam instabilities can explain most major features of the observed BEN spectrum. The results explain the gradual rise in the upper frequency range of BEN as a spacecraft approaches the plasma sheet from the lobe, and the sudden jump in that frequency up to near the plasma frequency upon crossing the PSBL.

Grabbe, Crockett L.↗

The Polar Plasma Wave Instrument

The Plasma Wave Instrument on the Polar spacecraft is designed to provide measurements of plasma waves in the Earth's polar regions over the frequency range from 0.1 Hz to 800 kHz. Three orthogonal electric dipole antennas are used to detect electric fields, two in the spin plane and one aligned along the spacecraft spin axis. A magnetic loop antenna and a triaxial magnetic search coil antenna are used to detect magnetic fields. Signals from these antennas are processed by five receiver systems: a wideband receiver, a high-frequency waveform receiver, a low-frequency waveform receiver, two multichannel analyzers; and a pair of sweep frequency receivers. Compared to previous plasma wave instruments, the Polar plasma wave instrument has several new capabilities. These include (1) an expanded frequency range to improve coverage of both low- and high-frequency wave phenomena, (2) the ability to simultaneously capture signals from six orthogonal electric and magnetic field sensors, and (3) a digital wideband receiver with up to 8-bit resolution and sample rates as high as 249k samples s(exp -1).

Gurnett, D. A.↗

Submillimeter Laboratory Investigations: Spectroscopy and Collisions

Currently, millimeter-wave and submillimeter-wave spectroscopy is conducted in our laboratory on several different types of spectrometers. Our standard spectrometer utilizes the output of a phase-locked klystron operating in the 40-60 GHz region, which is sent into a crossed-waveguide harmonic generator, or "multiplier". The high frequency millimeter-and submillimeter-wave radiation is transmitted via quasi-optical techniques through an absorption cell and then onto a detector, which is either an InSb hot electron bolometer cooled to 1.4 K or a Si bolometer cooled to 0.3 K. The detector response is sent to a computer for measurement and analysis. The frequency range produced and detected in this manner goes from 80 GHz to upwards of 1 THz. Spectra are normally taken with source modulation, with line frequencies typically measured to an accuracy of 50-100 kHz. Higher accuracy is available when needed. Recently, we developed a new, broad-band spectrometer in our laboratory based on a free-running backward wave oscillator (BWO) of Russian manufacture as the primary source of radiation. The so-called FASSST (fast-scan submillimeter spectroscopic technique) system uses fast-scan and optical calibration methods rather than the traditional locking techniques. The output power from the BWO is split such that 90% goes into the absorption cell while 10% is coupled to a 40-meter Fabry-Perot cavity, which yields fringe? for frequency measurement. Results from this spectrometer on the spectrum of nitric acid (HNO3) show that 100 GHz of spectral data can be obtained in 5 seconds with a measurement accuracy of 50 kHz. Currently, the frequency range of the FASSST system in our laboratory is roughly 100-700 GHz.

Herbst, Eric↗

Dielectric property of NiTiO{sub 3} doped substituted ortho-chloropolyaniline composites

Ortho-chloropolyaniline (OCP)-NiTiO{sub 3} composites have been synthesized via in-situ polymerization of ortho-chloroaniline with various weight percentages of NiTiO{sub 3.} Fourier Transform Infrared spectroscopic studies of Ortho-chloropolyaniline and its composites indicated the formation of composites as a result of Vander Waal's interaction between OCP and NiTiO{sub 3} particles. Surface morphology of OCP and OCP-NiTiO{sub 3} composites were studied using Scanning Electron Microscope (SEM). The SEM micrographs indicated a modified morphology after the composite formation. Dielectric properties and electric modulus of OCP and OCP-NiTiO{sub 3} composites have been investigated in the frequency range of 50 Hz – 5 MHz. It has been noticed that electrical resistance decreases with increase in weight percentage of NiTiO{sub 3} particles in polymer matrix as well as with applied frequency. The display of semicircular arcs in Cole-Cole plots indicates the formation of series resistor and capacitor in network causing a decrease in the relaxation time and as a result conductivity enhances in these composites. The facile and cost effective synthesis process and excellent dielectric and conductivity response of these materials makes them promising materials for practical applications.

36 MATERIALS SCIENCE↗

Ferroelectric and dielectric study of strontium tantalum based perovskite oxynitride films deposited by reactive rf magnetron sputtering

Highlights: • Oxynitride perovskite thin films were deposited by reactive sputtering. • Films are textured or epitaxially grown on MgO and Nb-SrTiO{sub 3} substrates. • Local piezoelectric and ferroelectric behavior was highlighted by PFM. • A 1600 nm-thick film presents a permittivity of 175 at 10 kHz and RT. • Permittivity is around 65 in high frequency range. - Abstract: Strontium and tantalum based oxynitride perovskite thin films were deposited by reactive magnetron sputtering. Epitaxial films deposited on Nb-SrTiO{sub 3} substrates show smooth surfaces with roughness values from 1.5 to 3.6 nm for a thickness of films in the range 20–1600 nm. The samples are yellow with band gap values around 2.35 eV. Piezo-force microscopy characterization pointed out the local piezoelectric and ferroelectric behavior of the oxynitride perovskite films. In the low frequency range, the 1600 nm-thick film exhibits a permittivity of 175 at 10 kHz, with dielectric losses of 0.055. Permittivity is lowered in high frequencies with a value around 65 obtained on a 1520 nm-thick film deposited on MgO substrate, which is textured with a preferential c-axis orientation. No accordability of the permittivity was highlighted at a macroscopic scale. The moderate crystallographic strain evidenced in the 20 nm thin film does not induce a high permittivity.

36 MATERIALS SCIENCE↗

Automated design of an additive manufactured compact broadband antenna for plasma reflectometry

Broadband antennas operating in the gigahertz frequency range are regularly used for plasma reflectometry diagnostics. Due to a lack of space and unique diagnostic constraints, these antennas are often custom in design and frequency range. Recent advances in additive manufacturing of high temperature copper alloys allow for expanded freedom in design of these diagnostic antennas. In this work, a heuristic simulated annealing algorithm is used alongside 3-D finite element simulation to automate the design of a double ridged rectangular horn antenna for a reflectometry diagnostic on the DIII-D tokamak. Optimization of antenna performance given the design constraints results in a compact broadband (6-20+ GHz) antenna design. Measured transmission from the additively manufactured antenna matches simulation within reasonable error, and experimental plasma electron density profiles from the DIII-D high-field side scrape-off layer are shown.

Additive manufacturing↗