Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flue gas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Retrofitting Holcim Ste. Genevieve Cement Plant with CO2 Capture Plant Using Air Liquide Cryocap™ FG Technology

The global cement manufacturing industry is a major contributor to carbon dioxide emissions. The International Energy Agency's "Net Zero Emissions by 2050 Scenario" identifies CCS as a major strategy for meeting that goal. This project is among the first attempts to transfer capture technology developed at coal-fired power plants to the cement industry. The main objective of the project is to execute and complete a front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separates 95% of the total CO2 emissions at the Holcim (US) Ste. Genevieve cement manufacturing facility using Air Liquide’s Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology. The Holcim Ste. Genevieve cement plant in Missouri, US, boasts one of the largest single cement production lines in the world, with a capacity of approximately 12,000 t/day. The plant currently uses traditional fuels, namely coal and petcoke. The captured CO2 will be pipeline and geological storage grade. The industrial host site emits approximately 3.0 million tonne CO2/yr. Air Liquide’s Cryocap™ technology has been developed over the last 18+ years for CO2 capture applications. It has been shown to be applicable to a variety of industrial applications (e.g., steel, cement, SMR, Fluidized Catalytic Crackers (FCCs)). Cryocap™ FG consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The project team is led by the Prairie Research Institute at the University of Illinois at Urbana-Champaign. The tasks include: complete FEED study for retrofitting the industrial facility with a carbon capture system to support developing a detailed cost estimate; business case analysis outlining the anticipated revenue and credits if projects was built and operated; technoeconomic analysis (TEA) outlining how capture system achieves DOE capture goals; and life cycle (LCA) analysis demonstrating zero net carbon emissions. The FEED study was successfully completed. This includes completing the process basis of design; preliminary engineering; outside battery limits (OSBL) detailed engineering including a Zero Liquid Discharge (ZLD) wastewater treatment system; inside battery limits (ISBL) detailed engineering [1]. An overall project capital cost estimate within a -20%/+30% accuracy was developed. The major contributors to the Total Plant Cost (TPC), by system, are the costs associated with the Outside Battery Limit (OSBL) section of the plant which includes a new river water intake structure and a Zero Liquid Discharge (ZLD) system. By cost category, the major contributors to the TPC are equipment and subcontractor costs, followed closely by engineering, construction management, home office and contractor fees. The TEA has been created to reflect the findings of the project. It analyzes the economic performance of the Cryocap™ technology by reviewing the estimated capital costs, operating cost, and revenue. The Cost of Capture (COC) associated with the Cryocap™ technology for 95% CO2 capture, when considering NETL 2018 economic assumptions (42/58 debt/equity ratio, 5.15% interest on debt and 1.42% return on equity in real dollars) and 2022 economic assumptions (42/58 debt/equity ratio, 8.82% interest on debt and 4.90% return on equity in real dollars) was found to be much lower than that for the DOE-NETL’s base-line cases. The highest contributors to the COC are annualized capital expenditures (CAPEX) and electricity consumption which can be offset by using lower cost renewable sources. The LCA was conducted using OpenLCA which is an open-source software that is recommended by NETL. The database utilized for this study was a modified version of TRACI 2.1 (developed by the US. Environmental Protection Agency’s National Risk Management Research Laboratory and modified by NETL). The Cryocap™ FG technology does not consume fuels in significant quantities and does not utilize specialized chemical solvents subject to decomposition, such as those utilized in amine-based carbon capture systems. The Cryocap™ FG technology mainly utilizes electricity as its energy input; hence, its calculated emissions are mainly associated with the generation of electricity offsite and are dependent on the energy matrix of the grid at the time of project implementation. The water consumption impact of the Cryocap™ FG is mostly for makeup of the water lost by evaporation in the cooling tower; however, the carbon capture plant will be equipped with a ZLD system to avoid effluent streams and minimize water consumption. The successful construction and operation of this plant based on this study results will provide a means to demonstrate an economically attractive and transformational capture technology that can be used to retrofit existing plants and be deployed at new plants.

01 COAL, LIGNITE, AND PEAT↗

Computational Fluid Dynamics Analysis of a 12 MW Circulating Fluidized Bed Rise

A three-dimensional (3D) two fluid model (TFM) model of the 12 MW circulating fluidized bed (CFB) riser at Chalmers University was developed using the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite. The hydrodynamic behavior of the riser was validated by comparing axial pressure profiles from experimental measurements with the results from the simulations. Under some of the operating conditions where there was no external circulation of solids, the pressure profiles from the simulation matched well with the experimental measurements. For the cases where there was external circulation of solids, the pressure profiles with the monodisperse solid phase modeling underpredicted the solids concentration in the freeboard region. With the inclusion of polydispersity in the model, the predicted pressure profiles agreed well with the experimental measurements. A two-dimensional (2D) model of the riser was used to perform simulations of coal combustion. The predicted flue gas outlet compositions of oxygen and carbon dioxide compared reasonably to experiments. The experiments also reported some concentration of carbon monoxide which was overpredicted in the simulations. Additional experimental data such as axial oxygen concentration profile and pressure profiles were also compared with the experiment. It was observed that the oxygen concentration in the bottom bed from the simulations was higher than in the experiments, which suggested that most of the oxidation reactions occurred in the bottom bed. The concentration of volatiles and char in the simulations was lower in the bottom bed than in the experiments, which suggest that there is not sufficient penetration of the solid phase species into the bed.

20 FOSSIL-FUELED POWER PLANTS↗

Initial Engineering Design of a Post-Combustion CO 2 Capture (PCC) System for Duke Energy’s East Bend Station Using Membrane-Based Technology

The Electric Power Research Institute (EPRI) led a U.S. Department of Energy (DOE) funded study for a membrane-based post-combustion CO 2 capture (PCC) system retrofit to an existing U.S. coal power plant. EPRI teamed with technology suppliers, Membrane Technology and Research (MTR), engineering consultants Nexant, Trimeric Corporation and Bechtel Power Corporation, to develop a first-of-a-kind initial design and cost estimate for a PCC system at Duke Energy’s East Bend Station (EBS) in Kentucky. This project provides a comprehensive overview of the plant design proposed and develops estimated costs to within +/- 30% accuracy for retrofitting the existing EBS coal-fired power plant with the latest MTR’s second-generation Polaris™ membrane technology for CO 2 flue gas removal. The projects primary objective was to develop a design for Duke Energy that will require “minimally invasive surgery” on their existing 600-MWe coal-fired power plant, located on the Ohio River in Boone County, Kentucky. Unlike the current commercially available solvent-based capture systems that require a reliable source of steam to operate, the MTR membrane-based capture system is driven primarily by electric power. This direct, bolt-on approach to retrofitting carbon capture could potentially reduce the impact on the existing power plant, by minimal disruption of the existing facility’s infrastructure and operating procedures. This may also reduce the amount of retrofit downtime before the power plant can resume normal operations. A second objective was to reduce the cost of each ton of captured CO 2 while maintaining the existing 600 MW net output of the East Bend Station. With this aim in mind, various options to provide the necessary auxiliary power for the capture system were evaluated for the site. The full report describes in detail the overall design, layout and components of the entire EBS membrane capture system. The equipment and sizes, the capital cost estimate encompassing both engineering design and construction for the carbon capture process and balance of plant systems is presented. A detailed techno-economic analysis is also undertaken to examine the business case for capture.

01 COAL, LIGNITE, AND PEAT↗

Results of the 2018 Wood Stove Design Challenge

The 2018 Wood Stove Design Challenge was an international design competition which sought to identify top performing residential wood stoves based on automation. To prepare for the event, the Northeast States for Coordinated Air Use Management (NESCAUM) developed a testing protocol that challenged the stoves by testing them in more field-like conditions—capturing emissions from start-up, reloading a stove, and the use of larger piece sizes. Flue gas emissions were measured using a combination of in-stack and novel dilution sampling methods, as the event occurred on the National Mall in Washington D.C. in a non-laboratory setting. Particulate matter (PM), carbon monoxide (CO), carbon dioxide (CO2), and methane (CH4) were measured from three stoves in real-time. A combustion efficiency was also calculated for each stove in real-time. Measured PM emission rates ranged between 1.8 and 8.0 g/hr for all stoves and operating conditions, with the highest emissions being measured during cold start in all cases. The test average PM emission rates were 2.4, 4.0, and 2.4 g/hr for stoves A, B, and C, respectively. Results showed emissions measured during transient operations, which are often excluded in current certification methods, can be significantly higher than steady-state periods—echoing other studies and highlighting the importance of testing in various operational modes for more realistic emission estimates. Additionally, the stoves had overall CO emission rates of 48.8, 284.8, and 100.8 g/hr, for stoves A, B and C, respectively. Calculated PM and CO emission factors overall were low considering the testing protocol sought to follow more challenging yet realistic practices in terms of fuel loading and operating procedures. The overall estimated combustion efficiency for stoves A, B, and C was 85%, 78%, 76%, respectively and in all cases was lowest during the cold start period.This report details the successfully proposed and assembled instrumentation that was relatively portable for field-site testing and the results of the emissions measurements for the 2018 Wood Stove Design Challenge competition. Overall, the repeatability of each stove was favorable with coefficients of variation (COV) ranging from 7 to 15% for measured PM concentrations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FWP FEW0223: "Advanced Manufactured Carbonate Materials for Algal Biomass Production: Joint LLNL SNL Program" (Final Report)

The ability to easily and cheaply transport carbon dioxide (CO 2 ) from coal-fired power plants equipped with capture facilities to multiple, potentially distant utilization sites of widely varying scales will enable wider use of CO 2 captured from flue gas. In the case of algal biomass cultivation, delivery of CO 2 in the form of carbonate-based materials may provide a more efficient and economical method of inorganic carbon delivery than CO 2 sparging, reducing the cost of algae cultivation and increasing the value of carbon capture. Lawrence Livermore National Laboratory (LLNL) has developed advanced manufactured materials that are well-suited for carbon capture, storage, transport, and delivery. These materials consist of aqueous sodium carbonate, which captures CO 2 as sodium bicarbonate, extruded or 3D printed in a CO 2 permeable polymer to increase the surface area and improve capture kinetics. By encapsulating carbonate solutions, LLNL has demonstrated order-of-magnitude enhancements in carbon capture rates compared with liquid carbonates, enabling the use of these (otherwise kinetically-limited) inexpensive, environmentally-benign solvents for carbon capture.

20 FOSSIL-FUELED POWER PLANTS↗

Energy Efficient Waste Heat Coupled Forward Osmosis for Effluent Water Management at Coal-Fired Power Plants

This project sought to evaluate the technical and economic viability of the Aquapod©, a transformational low energy (<200 kJ/kg water) waste heat coupled forward osmosis (FO) technology, to manage effluents, meet cooling water demands, and achieve water conservation in a coal-fired power plant environment. The Aquapod© process is innovative because it is heat-driven, avoids the evaporation of water, and uses no toxic chemicals such as ammonia or amines. The Aquapod© process accomplishes this using an aqueous two-phase system (ATPS) coupled FO process. The evaluation revealed that the Aquapod© process offers a pathway to exploit waste heat resources within a power plant to achieve flue-gas desulfurization (FGD) wastewater volume reduction and water recovery with minimal pretreatment. Water recovery of 80% from FGD wastewater was achieved with minimal pretreatment, exceeding the project target of 50%. The estimated electrical energy of 2.16 kWh/m 3 of water produced for the Aquapod© process met the project target of < 3.6 kWh/m 3 . The heat required for the process operation was approximately 186 kJ/kg of produced water, which was slightly lower than the project target of 200 kJ/kg. The estimated treatment cost for installing and operating the Aquapod© process in conjunction with a spray dryer evaporator to achieve zero-liquid discharge (ZLD) of the 100 gpm FGD wastewater was $13.24/m 3 over a 30-year lifetime. As a point of reference, this study’s host power plant currently incurs a cost of $3.70/m 3 – $8.87/m3 on a discharged volume basis to discharge its wastewater into the publicly owned treatment works (POTW) after physical-chemical treatment. Therefore, the Illinois power plant would incur an incremental cost increase of $4.37/m 3 – 9.54/m 3 to achieve ZLD using the Aquapod© and spray dryer combination. Ample opportunities exist to further lower the ZLD capital and operating costs in the next design iteration to attain pipe parity at the higher end of the site treatment costs.

01 COAL, LIGNITE, AND PEAT↗

Demonstrations of Holistic, Lower Cost/Energy Effluent Water Management Approaches for Coal-Fired Energy Plants

The project work conducted under DOE award DE-FE0031678 was comprised of three overarching project goals: (1) evaluate the performance of Saltworks’ Flex EDR Selective process for treating wet flue gas desulfurization (FGD) wastewater, (2) conduct bench-scale testing of wastewater encapsulation as a byproduct management technology for the EDR generated brine, and (3) develop a dynamic water balance model encompassing the results of the aforementioned testing.

01 COAL, LIGNITE, AND PEAT↗

DEVELOPMENT OF A 25 MWTH FLAMELESS PRESSURIZED OXY-COMBUSTION PILOT

The Flameless Pressurized Oxy-Combustion (FPO) cycle, a novel flexible fuel technology, is being developed into a large pilot. This effort seeks to complete the preliminary engineering and planning of a 25 MWth Pilot Plant that will demonstrate the technology for scale-up to a commercial unit. The technology, pioneered by ITEA at the 5 MWth scale, must be brought to a higher technology readiness level (TRL) to be viable at the commercial scale. The 25 MWth pilot cycle was optimized for cost and technology development and demonstration. Preliminary drawings, layouts, and plans were defined. Process flow diagrams were used to describe the pilot configuration in greater detail. A heat and mass balance with stream data was created. A master equipment list specified the operating conditions for major pieces of equipment within the pilot using this heat and mass balance. The 25 MWth FPO pilot is assessed for environmental performance. A test campaign is developed to assess the type of test and number of hours required for pilot demonstration. The environmental performance is compared against projected performance at the commercial scale. This project builds upon extensive evaluation of the techno-economic performance of the FPO technology already performed by ITEA. This includes system improvements, such as the addition of a turbo-expander to the flue gas stream. Some of the performance-enhancing components are not as well defined as others. The primary goal of this effort was to bring all of the core cycle components to the same level of design maturity. A techno-economic assessment (TEA) evaluated the FPO technology at the commercial scale in comparison to the NETL baseline cases. The reference plants were used in combination with proprietary equipment estimates to build a plant capital cost and cost of electricity evaluation. FPO performed better than the sub-bituminous post-combustion capture cases. Further preliminary estimates of improvements to the FPO cycle show even further gains when compared to conventional carbon capture methods.

20 FOSSIL-FUELED POWER PLANTS↗

Cooperative Research and Development Agreement between National Energy Technology Laboratory and Electric Power Research Institute (EPRI) [Abstract]

Carbon dioxide (CO 2 ) capture from flue gas generated by fossil fuel-fired power plants has been proposed as an efficient approach to limit CO 2 emissions to the atmosphere. Due to the high cyclic CO 2 sorption capacity, well-tuned adsorption chemistry and non-volatility, solid sorbents are widely studied for CO 2 capture processes such as pressure swing adsorption (PSA) and temperature swing adsorption (TSA). Realistic applications of traditional solid sorbent systems face many challenges since moisture and heat management are problematic and solid-solid heat exchange is inefficient. Recently, a novel solid sorbent system, the sorbent polymer composite (SPC), has been developed to overcome those challenges in an energy-saving CO 2 capture process using TSA membrane contactors. A SPC material is comprised of a powdered solid sorbent embedded into a hydrophobic and porous polymer matrix. It allows gases to permeate through and achieve full contact with the sorbents while rejecting water moisture in the CO 2 capture process. In this collaborative research, NETL will conduct performance testing of a novel SPC material and EPRI will conduct a cost analysis based on that performance data.

20 FOSSIL-FUELED POWER PLANTS↗

SECARB 2020 Semi-Annual Field Review Reports - Anthropogenic Test

The Southern States Energy Board (SSEB) managed the overall Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III project and the Electric Power Research Institute (EPRI) managed all activities associated with the Anthropogenic Test site. Advanced Resources International, Inc. (ARI) assisted EPRI with the management of site activities. EPRI and ARI followed reporting procedures that included monthly and quarterly technical progress reports, as well as periodic reporting on key field activities. Subsequent sections of this report catalog the field activities and are organized in a semi-annual chronology. The SECARB Anthropogenic Test was the largest demonstration of a fully integrated, pulverized coal-fueled carbon capture and storage (CCS) project in the United States as of 2012 and supports a commercial prototype of CO 2 capture; transportation; subsurface storage; and monitoring, verification, and accounting (MVA); and assessment. The demonstration-scale, post-combustion CO 2 capture facility at Alabama Power Company’s Plant Barry diverted flue gas (25MW equivalent) from its Unit #5 coal burning facility and captured the CO 2 using Mitsubishi Heavy Industries (MHI) KM-CDRTM advanced amine technology. The captured CO2 was compressed at Plant Barry and transported by pipeline to the injection location southeast of Citronelle, Alabama. The Citronelle Project’s geologic storage and MVA sites were located on the flanks of the Citronelle Dome, approximately three miles southeast of the city of Citronelle. The injection zone, the Paluxy Formation, a saline formation that occurs at approximately 9,400 feet and overlies the oil production horizon of the Citronelle oilfield, presents a favorable injection reservoir in terms of areal extent and petrophysical characteristics. The confining zone, the basal shale of the overlying Washita-Fredericksburg Formation, is persistent throughout the Citronelle area and possesses the appropriate criteria to act as an effective CO 2 seal.

01 COAL, LIGNITE, AND PEAT↗

Design and demonstration of an economical SRF structure for Continuous Wave (CW), high-energy, Megawatt-class beams

Due to its very high RF-to-beam efficiency, superconducting radiofrequency (SRF) cavities have become the technology of choice for the construction of large linear accelerators (linacs) for basic science applications (examples, ESS and PIP-II). The technology is also attractive for high volume industrial applications such as electron irradiation processing of wastewater and flue gas. However, SRF’s current reliance on liquid helium for cryogenic cooling introduces infrastructural and safety challenges for use in industrial settings. Cryocooler conduction-cooling is a recently developed novel technique for operating SRF cavities without requiring liquid helium. This project aims for technical design and economic assessment of a medium energy, high average power e-beam linac based on the conduction-cooled SRF technique for high volume irradiation treatment of wastewater. The goals of this project are (1) to design a medium energy (10 MeV), high average power (1 MW) electron beam accelerator around the cryocooler conduction-cooled SRF cavity technology, (2) demonstrate the required accelerating voltage on a prototype cavity, and (3) build a cost-model to evaluate capital and operating expense of the accelerator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Techno-Economic Analysis of Chemical Precipitation Followed by Low Hydraulic Residence Time Biological Treatment, Including Ultrafiltration

This National Energy Technology Laboratory (NETL) analysis is a techno-economic evaluation of chemical precipitation followed by low hydraulic residence time biological treatment, which was identified as Best Available Technology for treatment and control of selenium emissions from wet flue gas desulfurization wastewater streams.

54 ENVIRONMENTAL SCIENCES↗

Advanced Water-Related Technology Performance Development

This U.S. Department of Energy/National Energy Technology Laboratory techno-economic analysis evaluates those parameters having the greatest performance and cost impact on wet flue gas desulfurization (FGD) effluent wastewater treatment systems, and air cooled condensers for dry cooling systems. Two supercritical pulverized coal power plants are considered: 1) an existing plant (modified for surface water discharge and air emissions consistent with limits for existing plants) retrofitted with wet FGD effluent wastewater treatment and 2) a greenfield plant constructed with an air-cooled condenser (ACC). Sensitivity analyses are completed on various process parameters associated with the wet FGD effluent wastewater treatment system and ACC to determine the impact on the net plant efficiency and levelized cost of electricity (LCOE). Research and development targets are recommended for the parameters shown to have the greatest potential impact on cost or performance.

20 FOSSIL-FUELED POWER PLANTS↗

Large-Scale Commercial Carbon Capture Retrofit of the San Juan Generating Station

Enchant Energy, L.L.C. (Enchant) was selected to conduct a Front-End Engineering Design study (FEED) for the addition of a full-scale carbon capture system to remove carbon dioxide from the flue gas emissions of the two coal-fired generating units (total of 847 MW net) at San Juan Generating Station (SJGS), using Mitsubishi Heavy Industries Americas (MHIA) KM CDR Process™. Sargent & Lundy LLC (S&L) was selected as the primary technical lead, and along with various other organizations, were able to support Enchant’s completion of the following FEED tasks: Task 1 – Project Management & Planning; Task 2 – FEED Study; Task 3 - Final FEED Study Package. The FEED study period was between October 15, 2019 to September 30, 2022.

01 COAL, LIGNITE, AND PEAT↗

Pilot Test of a Nanoporous, Super-hydrophobic Membrane Contactor Process for Post-combustion CO 2 Capture

GTI Energy and Air Liquide Advanced Separations (ALaS) have been developing a novel hollow fiber membrane contactor (HFMC) technology for post-combustion CO 2 capture. The process combines advantageous features of both absorption and membrane-based separation processes to separate CO 2 from flue gas cost-effectively. The key component of the HFMC technology is the super-hydrophobic, porous hollow fiber, which is made from polyether ether ketone (PEEK). Compared to conventional absorption/desorption technologies, the critical advantage of the HFMC process is the high contact surface area provided by the hollow fibers enabling an increased volumetric mass-transfer rate. In the PEEK HFMC process, the specific surface area has been increased by an order of magnitude over structurally packed or trayed columns, resulting in compact systems with small footprints.

20 FOSSIL-FUELED POWER PLANTS↗

Membrane Carbonation for 100% Efficient Delivery of Industrial CO 2 Gases

Industrial processes generate about one quarter of all greenhouse gases emissions in the US, about 80% of which is carbon dioxide (CO 2 ). Biological processes are one of the largest natural sinks for atmospheric CO 2 , but the rate of capture is limited by the low concentration in air (~0.04%). Industrial emissions have significantly higher CO 2 concentrations, ranging from 5–80% CO 2 , which can significantly increase the rate of biological CO 2 capture, including many-fold improvements for cultivating microalgae to produce food, fertilizer, and renewable fuel. However, traditional methods for delivering CO 2 to microalgae using bubbling is < 40% efficient, leading to significant residual CO 2 emissions and increased cost. This project developed the Membrane Carbonation (MC) technology to significantly improve the CO 2 delivery efficiency to microalgae from power plant flue gas, wastewater treatment plant anaerobic digesters biogas (Figure 1), and other CO 2 -containing industrial sources.

09 BIOMASS FUELS↗

Commercial-Scale Front-End Engineering Design (Feed) Study for MTR’s Membrane CO 2 Capture Process

This is the final report for a DOE sponsored project (DE-FE00031846) where MTR, Sargent & Lundy (S&L), Trimeric Corporation (Trimeric), in cooperation with Basin Electric Power Cooperative (BEPC), and Electric Power Research Institute (EPRI), completed a full-scale Front End Engineering and Design (FEED) study to evaluate the retrofit of MTR’s membrane-based post-combustion carbon dioxide (CO2) capture technology to the BEPC Dry Fork Station (DFS) Unit 1. The capture plant is designed to treat the entire flue gas flow from DFS; it is estimated that this system will capture 6,560 tonnes per day (TPD) of carbon dioxide. The overall goal of the project was to develop an AACE Level 2 Capital Cost Estimate with an accuracy of ±15% to demonstrate the economic feasibility of constructing and operating the MTR CO2 capture plant.

01 COAL, LIGNITE, AND PEAT↗

CO2 Electrolyzer to Produce Formic Acid at Industry Relevant Current Density

Electrochemical CO2 reduction reaction (CO2RR) to produce formic acid has attracted great interest recently since formic acid can be used as a feedstock for biorefineries. Over the past decade, much effort has been devoted to the prospects of electrochemical CO2 conversion to formic acid. However, issues including low current density, low selectivity, low energy efficiency, poor long-term stability, and production of formate salts instead of formic acid remain as the great challenges for the development and commercialization of this technology. Recently, Dioxide Materials (DM) has developed an electrolyzer technology that can directly convert CO2 to pure formic acid with a three-compartment CO2 electrolyzer. In this work, DM will present our recent effort on improving the electrolyzer performance operating at industry relevant current density (200 mA/cm2). We have demonstrated 200 mA/cm² with 80% Faradaic efficiency for 1000 hours of operation. The effects of CO2 concentration and impurities in the flue gas on the electrolyzer performance will be discussed, as will ongoing efforts to test the device at a coal fired power plant. The long-term (1000 h) performance of the electrolyzer will also be presented.

Yang, Hongzhou↗