Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “faulting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of a Complex Faulted CO 2 Reservoir Using a Three-dimensional Hydro-geochemical-Mechanical Approach

This work applies a three-dimensional (3D) multiscale approach recently developed to analyze a complex CO 2 faulted reservoir that includes some key geological features of the San Andreas and nearby faults. The approach couples the STOMP-CO2-R code for flow and reactive transport modeling to the ABAQUS ® finite element package for geomechanical analysis. The objective is to examine the coupled hydro-geochemical-mechanical impact on the risk of hydraulic fracture and fault slip in a complex and representative CO 2 reservoir that contains two nearly parallel faults. STOMP-CO2-R/ABAQUS ® coupled analyses of this reservoir are performed assuming extensional and compressional stress regimes to predict evolutions of fluid pressure, stress and strain distributions as well as potential fault failure and leakage of CO 2 along the fault damage zones. The tendency for the faults to slip and pressure margin to fracture are examined in terms of stress regime, mineral composition, crack distributions in the fault damage zones and geomechanical properties. Here, this model in combination with a detailed description of the faults helps assess the coupled hydro-geochemical-mechanical effect.

58 GEOSCIENCES↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The geophysics, geology and mechanics of slow fault slip

We report that modern geodetic and seismologic observations describe the behavior of fault slip over a vast range of spatial and temporal scales. Slip at sub-seismogenic speeds is evident from top to bottom of lithospheric faults and plays an important role throughout the earthquake cycle. Where earthquakes and tremor accompany slow slip, they help illuminate the spatiotemporal evolution of fault slip. Geophysical subsurface imaging and geologic field studies provide information about suitable environments of slow slip. In particular, exhumed fault and shear zones from various depths reveal the importance of multiple deformation processes and fault-zone structures. Most geologic examples feature frictionally weak and velocity-strengthening materials, well-developed mineral fabrics, and abundant veining indicative of near-lithostatic fluid pressure. To produce transient slow slip events and tremor, in addition to the presence of high-pressure fluids a heterogeneous fault-zone structure, composition, and/or metamorphic assemblage may be needed. Laboratory and computational models suggest that velocity-weakening slip patches smaller than a critical dimension needed for earthquake nucleation will also fail in slow slip events. Changes in fluid pressure or slip rate can cause a fault to transition between stable and unstable fault slip behavior. Lastly, future interdisciplinary investigations of slow fault slip, directly integrating geophysical, geological and modeling investigations, will further improve our understanding of the dynamics of slow slip and aid in providing more accurate earthquake hazard characterizations.

58 GEOSCIENCES↗

Hydraulic characterization of a fault zone from fracture distribution

A quantitative assessment of how faults control the migration of geofluids is critical in many areas of geosciences. Here we integrated geological fieldwork, quantitative analysis of the fractures distribution and numerical modeling to build a geometrical representation of a fault zone and to characterize its hydraulic properties. Our target is a fault located in the Majella Mountain (Italy). We collected 21 scan lines across the fault profile in order to characterize its architecture. The numerical modeling of the fracture network of the damage zones and their hydraulic parameters was performed using both commercial (Move ® ) and open source software (dfnWorks and PFLOTRAN). Move ® was used to build a representative model of the fault zone using fracture spacing as a proxy, and to model the hydraulic parameters of the different fault domains. dfnWorks and PFLOTRAN were employed to infer the hydraulic parameters of the damage zones of the fault and then upscale these properties to an equivalent continuum domain, suitable for fluid flow simulations through the whole fault zone. Our findings show how even in a relatively small area it is possible to describe changes in terms of hydraulic properties of a fault zone and to build models capable to represent these variations.

58 GEOSCIENCES↗

Effect of Glacial/Interglacial Recharge Conditions on Flow of Meteoric Water Through Deep Orogenic Faults: Insights Into the Geothermal System at Grimsel Pass, Switzerland

Many meteoric-recharged, fault-hosted geothermal systems in amagmatic orogenic belts have been active through the Pleistocene glacial/interglacial climate fluctuations. The effects of such climate-induced recharge variations on fluid flow patterns and residence times of the thermal waters are complex and may influence how the geothermal and mineralization potential of the systems are evaluated. We report systematic thermal–hydraulic simulations designed to reveal the effects of recharge variations, using a model patterned on the orogenic geothermal system at Grimsel Pass in the Swiss Alps. Fault-bound circulation of meteoric water through the Grimsel fault is driven to depths of ~10 km by the high alpine topography. Simulations suggest that the current single pass flow is typical of interglacial periods, during which 1) meteoric recharge into the fault is high (above tens of centimeters per year), 2) conditions are at or somewhat below the critical Rayleigh number, and 3) the hydraulic connectivity along the fault plane is extensive (an extent of at least 10 km into increasingly higher terrain is required to explain the 10 km penetration depth). The subcritical condition constrains the bulk fault permeability to < 1e-14 m2. In contrast, the limited recharge during the numerous Pleistocene glaciation events likely induced a layered flow system with single pass flow confined to shallow depths while non-Rayleigh convection occurred in the deep fault. The same layering can be observed at low aspect ratios (length/depth) of the fault plane, when the available recharge area limits the flux through the fault.

58 GEOSCIENCES↗

Active Fault Current Limiting Control for Half-Bridge MMC in HVDC Systems

DC faults of MMC can result in a significantly large fault current due to the discharge of submodule capacitors. The fault current not only risks damaging the MMC but also demands a considerable breaking capacity from the dc circuit breaker (DCCBs). This paper introduces two novel active fault current limiting methods (AFCLs), namely virtual impedance-based and energy control-based AFCL. The first method utilizes circulating current feedforward, which introduces a virtual arm impedance to suppress the rate of rise of the fault current. Meanwhile, the second method relies on the control of the internally stored energy of the MMC to automatically minimize the number of submodules that discharge during a dc-side fault. Therefore, both the dc-side current and the MMC arm current can be effectively suppressed after the occurrence of the fault. The proposed methods do not require fault detection and their response is proportional to the rate of rise in the fault current. Simulation case studies are presented to demonstrate the proposed methods.

active current limiting control↗

Fault Modeling of Extreme Scale Applications Using Machine Learning

Faults are commonplace in large scale systems. These systems experience a variety of faults such as transient, permanent and intermittent. Multi-bit faults are typically not corrected by the hardware resulting in an error. Here, this paper attempts to answer an important question: Given a multi-bit fault in main memory, will it result in an application error — and hence a recovery algorithm should be invoked — or can it be safely ignored? We propose an application fault modeling methodology to answer this question. Given a fault signature (a set of attributes comprising of system and application state), we use machine learning to create a model which predicts whether a multibit permanent/transient main memory fault will likely result in error. We present the design elements such as the fault injection methodology for covering important data structures, the application and system attributes which should be used for learning the model, the supervised learning algorithms (and potentially ensembles), and important metrics. Lastly, we use three applications — NWChem, LULESH and SVM — as examples for demonstrating the effectiveness of the proposed fault modeling methodology.

97 MATHEMATICS AND COMPUTING↗

An Integrated Method of ANFIS and Dempster-Shafer Theory for Fault Diagnosis of Power Transformer

Dissolved gas analysis (DGA) approach is extensively applied to detect incipient faults of power transformers. This paper presents a novel DGA method for power transformer incipient fault diagnosis based on integrated adaptive neuro fuzzy inference system (ANFIS) and Dempster-Shafer Theory (DST). Four out of seven common conventional methods which are studied and compared for better consistency and accuracy, are used to develop new ANFIS based fault diagnosis models. To promote fault diagnostic performance further and make fault decision process more reliable and reasonable, an improved DST is introduced to integrate outputs of each ANFIS based model, and to provide comprehensive and convincing fault diagnosis results. The fault diagnosis capability of the proposed method is validated by a reported fault dataset and 10-fold cross validation experiment. The performance of the proposed method is compared with conventional approaches and ANFIS based models which demonstrate that the proposed method is superior to other methods and is more effective and stable for power transformer fault diagnosis with high accuracy and consistency.

adaptive nuero fuzzy inference system↗

Fault location in High Voltage Multi-terminal dc Networks Using Ensemble Learning

Precise location of faults for large distance power transmission networks is essential for faster repair and restoration process. High Voltage direct current (HVdc) networks using modular multi-level converter (MMC) technology has found its prominence for interconnected multi-terminal networks. This allows for large distance bulk power transmission at lower costs. However, they cope with the challenge of dc faults. Fast and efficient methods to isolate the network under dc faults have been widely studied and investigated. After successful isolation, it is essential to precisely locate the fault. The post-fault voltage and current signatures are a function of multiple factors and thus accurately locating faults on a multi-terminal network is challenging. In this paper, we discuss a novel data-driven ensemble learning based approach for accurate fault location. Here we utilize the eXtreme Gradient Boosting (XGB) method for accurate fault location. The sensitivity of the proposed algorithm to measurement noise, fault location, resistance and current limiting inductance are performed on a radial three-terminal MTdc network designed in Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault diagnosis and severity estimation in nuclear power plants - 196

Signed Directed Graph (SDG) is a type of fault diagnosis method with a capability to display the complex relationship between plant parameters and reveal the potential danger and the propagation path when a fault occurs in a nuclear plant. However, the fault diagnosis method based on qualitative SDG model inevitably has a number of disadvantages, and some of these disadvantages include its inability to identify reoccurring faults; ambiguous reasoning that can result in low resolution; performance that relies on the accuracy of the model; slow diagnosis rate for large systems and poor real-time diagnosis, among others. In this paper, we propose an SDG fault diagnosis methodology based on Granular Computing Theory, referred to as Granular Computing Signed Directed Graph (GCSDG). This paper shows how knowledge reduction nature of granular computing based fault diagnosis can simplify the decision table, reduce the allocation of resources, scale-down the complexity of the problem and improve the efficiency of data processing. Then, we estimate the severity of the fault using Back Propagation (BP) neural network approach. The proposed methodology was verified by considering certain faults in the primary loop of a PWR, using PCTRAN. The result shows a considerable improvement in fault diagnosis and the severity estimated serves as a useful information for the operator, providing a firm foundation for further intervention. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Representing Small Commercial Building Faults in EnergyPlus, Part II: Model Validation

Automated fault detection and diagnosis (AFDD) tools based on machine-learning algorithms hold promise for lowering cost barriers for AFDD in small commercial buildings; however, access to high-quality training data for such algorithms is often difficult to obtain. To fill the gap in this research area, this study covers the development (Part I) and validation (Part II) of fault models that can be used with the building energy modeling software EnergyPlus® and OpenStudio® to generate a cost-effective training data set for developing AFDD algorithms. Part II (this paper) first presents a methodology of validating fault models with OpenStudio and then presents validation results, which are compared against measurements from a reference building. We discuss the results of our experiments with eight different faults in the reference building (a total of 39 different baseline and faulted scenarios), including our methodology for using fault models along with the reference building model to simulate the same faulted scenarios. Then, we present validation of the fault models by comparing results of simulations and experiments either quantitatively or qualitatively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rifting Processes at a Continent‐Ocean Transition Rift Revealed by Fault Analysis: Example of Dabbahu‐Manda‐Hararo Rift (Ethiopia)

Abstract Analyses of fault attributes have contributed to unraveling fault growth processes in diverse tectonic settings. By integrating such analysis at the scale of a fault population, we propose to investigate the characteristics of a rift that has evolved up to a stage typical of a continent‐ocean transition. We address this problem by considering Dabbahu‐Manda‐Hararo (DMH) rift segment (Central Afar, Ethiopia), recognized for being in a late rifting stage. We quantify fault azimuth, length, and throw attributes for 668 normal faults. Along DMH rift, the mean fault density is 0.87 ± 0.7 km/km 2 and the median tectonic strain ranges from 1.8% to 3.1% assuming a fault dip of 60° and 45°, respectively. Maximum tectonic strain (>10%) is found where the rift azimuth changes. Along‐rift variations in fault azimuth, length, and scaling relationships suggest a different stage of rifting in the northern part of the rift. We show that this difference can be attributed to the influence of the Dabbahu volcano located at the northern tip of the rift, which captured the propagating Manda‐Hararo rift in the last ~100 kyr. The morpho‐tectonic analysis reveals numerous common features with slow‐spreading ridge segments, such as the Lucky Strike segment located along the Mid‐Atlantic ridge (segment length, spreading rate, associated magmatic system) but also with intermediate and fast ones (axial valley, fault throws, and diking). This study reveals that a rift at the continent‐ocean transition may be characterized by a transient and evolutionary behavior that shares features with oceanic ridges from slow‐ to fast‐spreading rates.

Dumont, S.↗

Measuring Fault Zone and Host Rock Hydraulic Properties Using Tidal Responses

Pore pressure diffusion along faults influences induced seismicity and rupture mechanics. In situ hydraulic diffusivity measurements along faults are rare and generally lower than inferred from seismicity migration. Here we use the tidal response of deep geothermal boreholes to measure fault diffusivity and permeability. Initial interpretations of the observation with a homogeneous confined aquifer model result in diffusivities of 10 -3 –10 -1 m 2 /s. However, this model mixes signals from both the conduit and the host rock. We develop a model for tidal response with a fault passing through the aquifer based on the fault-guided fracture network and solve for hydraulic properties in both the fault and the host rock. The resulting fault permeability is 2 × 10 -14 –7 × 10 -14 m 2 (90% confidence interval[CI]) and fault diffusivity is 0.08–0.33 m 2 /s (90% CI), which is 2 orders of magnitude higher than the host rock diffusivity in some wells, thus highlighting the role of faults as fluid conduits.

58 GEOSCIENCES↗

Image-based novel fault detection with deep learning classifiers using hierarchical labels

One important characteristic of modern fault classification systems is the ability to flag the system when faced with previously unseen fault types. This work considers the unknown fault detection capabilities of deep neural network-based fault classifiers. Specifically, we propose a methodology on how, when available, labels regarding the fault taxonomy can be used to increase unknown fault detection performance without sacrificing model performance. To achieve this, we propose to utilize soft label techniques to improve the state-of-the-art deep novel fault detection techniques during the training process and novel hierarchically consistent detection statistics for online novel fault detection. Lastly, we demonstrated increased detection performance on novel fault detection in inspection images from the hot steel rolling process, with results well replicated across multiple scenarios and baseline detection methods.

42 ENGINEERING↗

Optimization-Based Data-Driven Approach for Detecting Fault Location in Power Systems

In grids with large penetration of converterinterfaced resources (CIRs), measurements of voltage, current, and line parameters can fluctuate significantly during fault conditions. These fluctuations, combined with complex network topologies and extensive system branching, make accurate fault location challenging. Faults, such as short circuits, can cause prolonged outages with serious socio-economic impacts, highlighting the need for rapid fault identification to minimize downtime. However, current fault detection methods—such as relays and digital fault recorders—often relay information too slowly, impeding swift corrective action. Given the limited availability of high-resolution phasor measurement units, this paper introduces an optimization-based observer to estimate fault locations, grid line parameters, and voltages using local CIR measurements. To preserve the confidentiality of CIRs and enhance estimation accuracy, this study uses a black-box model of CIRs. This bottom-up, event-driven approach can enhances protection and control systems through optimized and real-time fault detection. Simulation results show that the optimization-based data-driven observer can accurately detect fault locations and estimate grid states and parameters, providing valuable insights for utilities and operators in grid applications.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Positive-Sequence Phasor Modeling of Droop-Controlled, Grid-Forming Inverters with Fault Current Limiting Function

Traditional positive-sequence phasor models of droop-controlled, grid-forming inverters do not have the fault current limiting function. During a short-circuit fault the model generates unrealistic high fault current making the simulation results less practical. This paper develops a fault current limiting function for the positive-sequence phasor model of droop-controlled, grid-forming inverters, which can effectively limit the inverter output current at the predefined maximum during faults. A user-written model has been developed for the commercially-available software Siemens/PTI PSS/E. Fault studies on a modified IEEE 39-bus system with all grid-forming inverters verify the effectiveness of the developed fault current limiting function. The proposed model can be used to evaluate how the limited fault currents of droop-controlled, grid-forming inverters impact the bulk power system transient stability under fault conditions.

Du, Wei↗