Active Fault Current Limiting Control for Half-Bridge MMC in HVDC Systems

DC faults of MMC can result in a significantly large fault current due to the discharge of submodule capacitors. The fault current not only risks damaging the MMC but also demands a considerable breaking capacity from the dc circuit breaker (DCCBs). This paper introduces two novel active fault current limiting methods (AFCLs), namely virtual impedance-based and energy control-based AFCL. The first method utilizes circulating current feedforward, which introduces a virtual arm impedance to suppress the rate of rise of the fault current. Meanwhile, the second method relies on the control of the internally stored energy of the MMC to automatically minimize the number of submodules that discharge during a dc-side fault. Therefore, both the dc-side current and the MMC arm current can be effectively suppressed after the occurrence of the fault. The proposed methods do not require fault detection and their response is proportional to the rate of rise in the fault current. Simulation case studies are presented to demonstrate the proposed methods.

active current limiting control↗

Fault Modeling of Extreme Scale Applications Using Machine Learning

Faults are commonplace in large scale systems. These systems experience a variety of faults such as transient, permanent and intermittent. Multi-bit faults are typically not corrected by the hardware resulting in an error. Here, this paper attempts to answer an important question: Given a multi-bit fault in main memory, will it result in an application error — and hence a recovery algorithm should be invoked — or can it be safely ignored? We propose an application fault modeling methodology to answer this question. Given a fault signature (a set of attributes comprising of system and application state), we use machine learning to create a model which predicts whether a multibit permanent/transient main memory fault will likely result in error. We present the design elements such as the fault injection methodology for covering important data structures, the application and system attributes which should be used for learning the model, the supervised learning algorithms (and potentially ensembles), and important metrics. Lastly, we use three applications — NWChem, LULESH and SVM — as examples for demonstrating the effectiveness of the proposed fault modeling methodology.

97 MATHEMATICS AND COMPUTING↗

An Integrated Method of ANFIS and Dempster-Shafer Theory for Fault Diagnosis of Power Transformer

Dissolved gas analysis (DGA) approach is extensively applied to detect incipient faults of power transformers. This paper presents a novel DGA method for power transformer incipient fault diagnosis based on integrated adaptive neuro fuzzy inference system (ANFIS) and Dempster-Shafer Theory (DST). Four out of seven common conventional methods which are studied and compared for better consistency and accuracy, are used to develop new ANFIS based fault diagnosis models. To promote fault diagnostic performance further and make fault decision process more reliable and reasonable, an improved DST is introduced to integrate outputs of each ANFIS based model, and to provide comprehensive and convincing fault diagnosis results. The fault diagnosis capability of the proposed method is validated by a reported fault dataset and 10-fold cross validation experiment. The performance of the proposed method is compared with conventional approaches and ANFIS based models which demonstrate that the proposed method is superior to other methods and is more effective and stable for power transformer fault diagnosis with high accuracy and consistency.

adaptive nuero fuzzy inference system↗

Fault location in High Voltage Multi-terminal dc Networks Using Ensemble Learning

Precise location of faults for large distance power transmission networks is essential for faster repair and restoration process. High Voltage direct current (HVdc) networks using modular multi-level converter (MMC) technology has found its prominence for interconnected multi-terminal networks. This allows for large distance bulk power transmission at lower costs. However, they cope with the challenge of dc faults. Fast and efficient methods to isolate the network under dc faults have been widely studied and investigated. After successful isolation, it is essential to precisely locate the fault. The post-fault voltage and current signatures are a function of multiple factors and thus accurately locating faults on a multi-terminal network is challenging. In this paper, we discuss a novel data-driven ensemble learning based approach for accurate fault location. Here we utilize the eXtreme Gradient Boosting (XGB) method for accurate fault location. The sensitivity of the proposed algorithm to measurement noise, fault location, resistance and current limiting inductance are performed on a radial three-terminal MTdc network designed in Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault diagnosis and severity estimation in nuclear power plants - 196

Signed Directed Graph (SDG) is a type of fault diagnosis method with a capability to display the complex relationship between plant parameters and reveal the potential danger and the propagation path when a fault occurs in a nuclear plant. However, the fault diagnosis method based on qualitative SDG model inevitably has a number of disadvantages, and some of these disadvantages include its inability to identify reoccurring faults; ambiguous reasoning that can result in low resolution; performance that relies on the accuracy of the model; slow diagnosis rate for large systems and poor real-time diagnosis, among others. In this paper, we propose an SDG fault diagnosis methodology based on Granular Computing Theory, referred to as Granular Computing Signed Directed Graph (GCSDG). This paper shows how knowledge reduction nature of granular computing based fault diagnosis can simplify the decision table, reduce the allocation of resources, scale-down the complexity of the problem and improve the efficiency of data processing. Then, we estimate the severity of the fault using Back Propagation (BP) neural network approach. The proposed methodology was verified by considering certain faults in the primary loop of a PWR, using PCTRAN. The result shows a considerable improvement in fault diagnosis and the severity estimated serves as a useful information for the operator, providing a firm foundation for further intervention. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Representing Small Commercial Building Faults in EnergyPlus, Part II: Model Validation

Automated fault detection and diagnosis (AFDD) tools based on machine-learning algorithms hold promise for lowering cost barriers for AFDD in small commercial buildings; however, access to high-quality training data for such algorithms is often difficult to obtain. To fill the gap in this research area, this study covers the development (Part I) and validation (Part II) of fault models that can be used with the building energy modeling software EnergyPlus® and OpenStudio® to generate a cost-effective training data set for developing AFDD algorithms. Part II (this paper) first presents a methodology of validating fault models with OpenStudio and then presents validation results, which are compared against measurements from a reference building. We discuss the results of our experiments with eight different faults in the reference building (a total of 39 different baseline and faulted scenarios), including our methodology for using fault models along with the reference building model to simulate the same faulted scenarios. Then, we present validation of the fault models by comparing results of simulations and experiments either quantitatively or qualitatively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rifting Processes at a Continent‐Ocean Transition Rift Revealed by Fault Analysis: Example of Dabbahu‐Manda‐Hararo Rift (Ethiopia)

Abstract Analyses of fault attributes have contributed to unraveling fault growth processes in diverse tectonic settings. By integrating such analysis at the scale of a fault population, we propose to investigate the characteristics of a rift that has evolved up to a stage typical of a continent‐ocean transition. We address this problem by considering Dabbahu‐Manda‐Hararo (DMH) rift segment (Central Afar, Ethiopia), recognized for being in a late rifting stage. We quantify fault azimuth, length, and throw attributes for 668 normal faults. Along DMH rift, the mean fault density is 0.87 ± 0.7 km/km 2 and the median tectonic strain ranges from 1.8% to 3.1% assuming a fault dip of 60° and 45°, respectively. Maximum tectonic strain (>10%) is found where the rift azimuth changes. Along‐rift variations in fault azimuth, length, and scaling relationships suggest a different stage of rifting in the northern part of the rift. We show that this difference can be attributed to the influence of the Dabbahu volcano located at the northern tip of the rift, which captured the propagating Manda‐Hararo rift in the last ~100 kyr. The morpho‐tectonic analysis reveals numerous common features with slow‐spreading ridge segments, such as the Lucky Strike segment located along the Mid‐Atlantic ridge (segment length, spreading rate, associated magmatic system) but also with intermediate and fast ones (axial valley, fault throws, and diking). This study reveals that a rift at the continent‐ocean transition may be characterized by a transient and evolutionary behavior that shares features with oceanic ridges from slow‐ to fast‐spreading rates.

Dumont, S.↗

Measuring Fault Zone and Host Rock Hydraulic Properties Using Tidal Responses

Pore pressure diffusion along faults influences induced seismicity and rupture mechanics. In situ hydraulic diffusivity measurements along faults are rare and generally lower than inferred from seismicity migration. Here we use the tidal response of deep geothermal boreholes to measure fault diffusivity and permeability. Initial interpretations of the observation with a homogeneous confined aquifer model result in diffusivities of 10 -3 –10 -1 m 2 /s. However, this model mixes signals from both the conduit and the host rock. We develop a model for tidal response with a fault passing through the aquifer based on the fault-guided fracture network and solve for hydraulic properties in both the fault and the host rock. The resulting fault permeability is 2 × 10 -14 –7 × 10 -14 m 2 (90% confidence interval[CI]) and fault diffusivity is 0.08–0.33 m 2 /s (90% CI), which is 2 orders of magnitude higher than the host rock diffusivity in some wells, thus highlighting the role of faults as fluid conduits.

58 GEOSCIENCES↗

Image-based novel fault detection with deep learning classifiers using hierarchical labels

One important characteristic of modern fault classification systems is the ability to flag the system when faced with previously unseen fault types. This work considers the unknown fault detection capabilities of deep neural network-based fault classifiers. Specifically, we propose a methodology on how, when available, labels regarding the fault taxonomy can be used to increase unknown fault detection performance without sacrificing model performance. To achieve this, we propose to utilize soft label techniques to improve the state-of-the-art deep novel fault detection techniques during the training process and novel hierarchically consistent detection statistics for online novel fault detection. Lastly, we demonstrated increased detection performance on novel fault detection in inspection images from the hot steel rolling process, with results well replicated across multiple scenarios and baseline detection methods.

42 ENGINEERING↗

Optimization-Based Data-Driven Approach for Detecting Fault Location in Power Systems

In grids with large penetration of converterinterfaced resources (CIRs), measurements of voltage, current, and line parameters can fluctuate significantly during fault conditions. These fluctuations, combined with complex network topologies and extensive system branching, make accurate fault location challenging. Faults, such as short circuits, can cause prolonged outages with serious socio-economic impacts, highlighting the need for rapid fault identification to minimize downtime. However, current fault detection methods—such as relays and digital fault recorders—often relay information too slowly, impeding swift corrective action. Given the limited availability of high-resolution phasor measurement units, this paper introduces an optimization-based observer to estimate fault locations, grid line parameters, and voltages using local CIR measurements. To preserve the confidentiality of CIRs and enhance estimation accuracy, this study uses a black-box model of CIRs. This bottom-up, event-driven approach can enhances protection and control systems through optimized and real-time fault detection. Simulation results show that the optimization-based data-driven observer can accurately detect fault locations and estimate grid states and parameters, providing valuable insights for utilities and operators in grid applications.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Positive-Sequence Phasor Modeling of Droop-Controlled, Grid-Forming Inverters with Fault Current Limiting Function

Traditional positive-sequence phasor models of droop-controlled, grid-forming inverters do not have the fault current limiting function. During a short-circuit fault the model generates unrealistic high fault current making the simulation results less practical. This paper develops a fault current limiting function for the positive-sequence phasor model of droop-controlled, grid-forming inverters, which can effectively limit the inverter output current at the predefined maximum during faults. A user-written model has been developed for the commercially-available software Siemens/PTI PSS/E. Fault studies on a modified IEEE 39-bus system with all grid-forming inverters verify the effectiveness of the developed fault current limiting function. The proposed model can be used to evaluate how the limited fault currents of droop-controlled, grid-forming inverters impact the bulk power system transient stability under fault conditions.

Du, Wei↗

Deep Convolutional Neural Networks for Distribution System Fault Classification

Faults happen very frequently in distribution systems. Identifying fault types and phases are of critical importance for outage management, fault location, and service restoration. However, this task becomes very challenging due to measurement scarcity in distribution systems. This paper is among the first few that applies deep learning techniques in distribution system fault classification. Specifically, a sequential Convolutional Neural Network(CNN)-based classifier is developed to identify fault buses and phases. The input to the CNN is the steady-state voltage and current data measured at substations. The fault identification is modeled as a multi-label classification problem. Training data under various fault scenarios are obtained in OpenDSS and Gaussian noises are added to mimic measurement errors. A case study in IEEE 13-feeder test system is conducted with single and multiple bus faults scenarios. Numerical results demonstrate the high accuracy and fast computation of the proposed deep CNN-based fault classification.

Tian, Guanyu↗

Hydrologic Impacts of a Strike-Slip Fault Zone: Insights from Joint 3D Body-Wave Tomography of Rock Valley

The Rock Valley fault zone (RVFZ), an intraplate strike-slip fault zone in the southern Nevada National Security Site (NNSS), hosted a series of very shallow (<3 km) earthquakes in 1993. The RVFZ may also have hydrological significance within the NNSS, potentially playing a role in regional groundwater flow, but there is a lack of local hydrological data. In the Spring of 2021, we collected active-source accelerated weight drop seismic data over part of the RVFZ to better characterize the shallow subsurface. Here, we manually picked ~17,000 P-wave travel times and over 14,000 S-wave travel times, which were inverted for P-wave velocity (V P ), S-wave velocity (V S ), and V P /V S ratio in a 3D joint tomographic inversion scheme. Seismic velocities are imaged as deep as ~700 m in areas and generally align with geologic and structural expectations. V P and V S are relatively reduced near mapped and inferred faults, with the most prominent lower V P and V S zone around the densest collection of faults. We image V P /V S ratios ranging from ~1.5 to ~2.4, the extremes of which occur at a depth of ~100 m and are juxtaposed across a fault. One possible interpretation of the imaged seismic velocities is enhanced fault damage near the densest collection of faults with relatively higher porosity and/or crack density at ~100 m depth, with patches of semiperched groundwater present in the sedimentary rock in higher V P /V S areas and drier rock in lower V P /V S areas. A relatively higher V P /V S area beneath the densest faults persists at depth, which suggests percolation of groundwater via the fault damage zone to the regionally connected lower carbonate aquifer. Potentially, the presence and movement of groundwater may have played a role in the 1993 earthquake aftershocks.

58 GEOSCIENCES↗

Modeling Air Handling Units to Create a Diverse Fault Dataset for FDD Innovation: Lessons Learned and Recommendations

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault datasets for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling unit and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for the air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, two detailed AHU models, which included the single duct AHU and dual duct AHU developed in the Modelica language and HVACSIM+ were employed to carry out annual simulations of numerous common sensor faults, mechanical faults, and control sequence faults. The fault inclusive data were then validated by comparing fault effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. We report some lessons learnt during the efforts of validating the high volumes of the FDD data sets. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

What's in a Name? Developing a Standardized Taxonomy for HVAC System Faults

Faults occurring in heating, ventilation and air-conditioning (HVAC) systems have significantly negative impacts on building energy consumption, occupant comfort, and indoor air quality. In the past thirty years, extensive research has been conducted on fault detection and diagnostics (FDD) methods, and there are now dozens of commercially available FDD software tools. Growing adoption of FDD tools has the potential to generate a massive and useful data set on fault characteristics. However, the lack of a unifying taxonomy is a significant barrier to efficient analysis and evaluation of FDD outputs. Therefore, there is a strong need to develop a robust taxonomy which can better represent and interpret FDD output data. This paper documents the development of a unifying taxonomy for HVAC system faults in commercial buildings, with initial focus on air handling units, variable air volume terminal units, and roof top unit systems. The developed fault taxonomy employs both a physical hierarchy of HVAC equipment and a cause-effect relationship model as tools to better understand and support root cause analysis for HVAC faults. A variable air volume terminal unit is used as an example to demonstrate the application of the developed fault taxonomy. The taxonomy has short-term application in a major U.S. study on fault prevalence, and promises longer term benefits to FDD software developers and building operators by creating a foundation for improved approaches to identifying and resolving HVAC faults.

Chen, Yimin↗

Micro- and nano-porosity of the active Alpine Fault zone, New Zealand

Porosity reduction in rocks from a fault core can cause elevated pore fluid pressures and consequently influence the recurrence time of earthquakes. We investigated the porosity distribution in the New Zealand's Alpine Fault core in samples recovered during the first phase of the Deep Fault Drilling Project (DFDP-1B) by using two-dimensional nanoscale and three-dimensional microscale imaging. Synchrotron X-ray microtomography-derived analyses of open pore spaces show total microscale porosities in the range of 0.1 %–0.24 %. These pores have mainly non-spherical, elongated, flat shapes and show subtle bipolar orientation. Scanning and transmission electron microscopy reveal the samples' microstructural organization, where nanoscale pores ornament grain boundaries of the gouge material, especially clay minerals. Our data imply that (i) the porosity of the fault core is very small and not connected; (ii) the distribution of clay minerals controls the shape and orientation of the associated pores; (iii) porosity was reduced due to pressure solution processes; and (iv) mineral precipitation in fluid-filled pores can affect the mechanical behavior of the Alpine Fault by decreasing the already critically low total porosity of the fault core, causing elevated pore fluid pressures and/or introducing weak mineral phases, and thus lowering the overall fault frictional strength. We conclude that the current state of very low porosity in the Alpine Fault core is likely to play a key role in the initiation of the next fault rupture.

58 GEOSCIENCES↗

Earthquake epicenters and fault intersections in central and southern California

The author has identifed the following significant results. ERTS-1 imagery provided evidence for the existence of short transverse fault segments lodged between faults of the San Andreas system in the Coast Ranges, California. They indicate that an early episode of transverse shear has affected the Coast Ranges prior to the establishment of the present San Andreas fault. The fault has been offset by transverse faults of the Transverse Ranges. It appears feasible to identify from ERTS-1 imagery geomorphic criteria of recent fault movements. Plots of historic earthquakes in the Coast Ranges and western Transverse Ranges show clusters in areas where structures are complicated by interaction of tow active fault systems. A fault lineament apparently not previously mapped was identified in the Uinta Mountains, Utah. Part of the lineament show evidence of recent faulting which corresponds to a moderate earthquake cluster.

Abdel-Gawad, M.↗

Diagnosable systems for intermittent faults

The fault diagnosis capabilities of systems composed of interconnected units capable of testing each other are studied for the case of systems with intermittent faults. A central role is played by the concept of t(i)-fault diagnosability. A system is said to be t(i)-fault diagnosable when it is such that if no more than t(i) units are intermittently faulty then a fault-free unit will never be diagnosed as faulty and the diagnosis at any time is at worst incomplete. Necessary and sufficient conditions for t(i)-fault diagnosability are proved, and bounds for t(i) are established. The conditions are in general more restrictive than those for permanent-fault diagnosability. For intermittent faults there is only one testing strategy (repetitive testing), and consequently only one type of intermittent-fault diagnosable system.

Mallela, S.↗