Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “false positive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Uncovering novel mutational signatures by de novo extraction with SigProfilerExtractor

Mutational signature analysis is commonly performed in cancer genomic studies. Here, we present SigProfilerExtractor, an automated tool for de novo extraction of mutational signatures, and benchmark it against another 13 bioinformatics tools by using 34 scenarios encompassing 2,500 simulated signatures found in 60,000 synthetic genomes and 20,000 synthetic exomes. For simulations with 5% noise, reflecting high-quality datasets, SigProfilerExtractor outperforms other approaches by elucidating between 20% and 50% more true-positive signatures while yielding 5-fold less false-positive signatures. Applying SigProfilerExtractor to 4,643 whole-genome- and 19,184 whole-exome-sequenced cancers reveals four novel signatures. Two of the signatures are confirmed in independent cohorts, and one of these signatures is associated with tobacco smoking. In summary, this report provides a reference tool for analysis of mutational signatures, a comprehensive benchmarking of bioinformatics tools for extracting signatures, and several novel mutational signatures, including one putatively attributed to direct tobacco smoking mutagenesis in bladder tissues.

59 BASIC BIOLOGICAL SCIENCES↗

WE-H-BRC-05: Catastrophic Error Metrics for Radiation Therapy

Purpose: Intuitive evaluation of complex radiotherapy treatments is impractical, while data transfer anomalies create the potential for catastrophic treatment delivery errors. Contrary to prevailing wisdom, logical scrutiny can be applied to patient-specific machine settings. Such tests can be automated, applied at the point of treatment delivery and can be dissociated from prior states of the treatment plan, potentially revealing errors introduced early in the process. Methods: Analytical metrics were formulated for conventional and intensity modulated RT (IMRT) treatments. These were designed to assess consistency between monitor unit settings, wedge values, prescription dose and leaf positioning (IMRT). Institutional metric averages for 218 clinical plans were stratified over multiple anatomical sites. Treatment delivery errors were simulated using a commercial treatment planning system and metric behavior assessed via receiver-operator-characteristic (ROC) analysis. A positive result was returned if the erred plan metric value exceeded a given number of standard deviations, e.g. 2. The finding was declared true positive if the dosimetric impact exceeded 25%. ROC curves were generated over a range of metric standard deviations. Results: Data for the conventional treatment metric indicated standard deviations of 3%, 12%, 11%, 8%, and 5 % for brain, pelvis, abdomen, lung and breast sites, respectively. Optimum error declaration thresholds yielded true positive rates (TPR) between 0.7 and 1, and false positive rates (FPR) between 0 and 0.2. Two proposed IMRT metrics possessed standard deviations of 23% and 37%. The superior metric returned TPR and FPR of 0.7 and 0.2, respectively, when both leaf position and MUs were modelled. Isolation to only leaf position errors yielded TPR and FPR values of 0.9 and 0.1. Conclusion: Logical tests can reveal treatment delivery errors and prevent large, catastrophic errors. Analytical metrics are able to identify errors in monitor units, wedging and leaf positions with favorable sensitivity and specificity. In part by Varian.

60 APPLIED LIFE SCIENCES↗

Performance Evaluation of a Shaped Sonic Boom Detector and Classifier

NASA will soon fly the X‑59 aircraft over selected communities to evaluate community responses to shaped sonic booms. Community tests will include dozens of deployed acoustic sensors capable of measuring and detecting shaped sonic boom waveforms in situ for rapid onboard analysis. To this end, we present a sonic boom detector and classifier. The sonic boom detector identifies a shaped sonic boom within a measured acoustical waveform by calculating the cross-correlation with a template shaped sonic boom waveform. The sonic boom classifier determines whether the identified event is indeed a shaped sonic boom based on the correlation coefficient and the calculated noise exposure level. We evaluate these algorithms using simulations of on- and off-design X-59 sonic boom waveforms injected into previously measured 30 s ambient noise recordings. Results of this case study indicate that the detector identifies a sonic boom with an accuracy of ±100 ms in 99.98% of the cases. Furthermore, for a given 30 s measurement, the classifier shows true-positive rates of approximately 0.9999 when the false-positive rate is 10e-3. The case study demonstrates that the recommended onboard sonic boom detector and classifier should be highly capable of identifying shaped sonic booms.

sonic boom↗

Comparison of two culture methods for the enumeration of Legionella pneumophila from potable water samples

Legionella infections have steadily increased in the United States over the last 20 years, and most of these infections have been attributed to contaminated water. The gold standard for confirmation of Legionella presence in water is culturing with Buffered Charcoal Yeast Extract (BCYE) agar. Following many modifications, this method is still time-consuming, expensive, and can take longer than 10 days for full confirmation. The Legiolert is a newer and simpler culture product that is claimed to be able to quantify Legionella pneumophila in 7 days with high sensitivity and specificity and does not need further confirmation for the presence of L. pneumophila. This study compared the culturability of L. pneumophila occurring in a simulated home plumbing system using both Legiolert and BCYE agar methods. Out of 185 water samples, Legiolert and BCYE method detected L. pneumophila in 83 and 85% of the samples, respectively. The two methods were determined to be statistically equivalent for culturability of L. pneumophila, though the detected levels by Legiolert were slightly higher than the BCYE method. The molecular confirmation of positive (n = 254) and negative wells (n = 82) with Legiolert also showed a high specificity of 96.5% (i.e., 3.5% false positives (9/254) and 0% false negatives (0/82)).

Boczek, Laura A.↗

Determination of cellulose crystallinity from powder diffraction diagrams: Powder Diffraction Diagrams

Commonly one-dimensional (1D) (spherically averaged) powder diffraction diagrams are used to determine the degree of cellulose crystallinity in biomass samples. Here, it is shown using molecular modeling how disorder in cellulose fibrils can lead to considerable uncertainty in conclusions drawn concerning crystallinity based on 1D powder diffraction data alone. For example, cellulose microfibrils that contain both crystalline and noncrystalline segments can lead to powder diffraction diagrams lacking identifiable peaks, while microfibrils without any crystalline segments can lead to such peaks. Moreover, this leads to false positives, that is, assigning disordered cellulose as crystalline, and false negatives, that is, categorizing fibrils with crystalline segments as amorphous. Finally, the reliable determination of the fraction of crystallinity in any given biomass sample will require a more sophisticated approach combining detailed experiment and simulation.

36 MATERIALS SCIENCE↗

AviSense: A Real-time System for Detection, Classification, and Analysis of Aviation Signals

Wireless systems are an integral part of aviation. Apart from their apparent use in air-to-ground communication, wireless systems play a crucial role in avionic functions including navigation and landing. An interference-free wireless environment is therefore critical for the uninterrupted operation and safety of an aircraft. Hence, there is an urgency for airport facilities to acquire the capability to continuously monitor aviation frequency bands for real-time detection of interference and anomalies. To meet this critical need, we design and build AviSense, an SDR-based real-time, versatile system for monitoring aviation bands. AviSense detects and characterizes signal activities to enable practical and effective anomaly detection. We identify and tackle the challenges posed by a diverse set of critical aviation bands and technologies. We evaluate our methodology with real-world aviation signal measurements and two custom datasets of anomalous signals. We find that our signal classification capability achieves a true positive rate of ~99%, with few exceptions, and a false positive rate of less than 4%. We also demonstrate that AviSense can effectively distinguish between different types of anomalies. We build and evaluate a prototype implementation of AviSense that supports distributed monitoring.

42 ENGINEERING↗

Gaia Assorted Mass Binaries Long Excluded from SLoWPoKES (GAMBLES): Identifying Ultra-wide Binary Pairs with Components of Diverse Mass

The formation and evolution of binary star systems are some of the remaining key questions in modern astronomy. Wide binary pairs (separations >10{sup 3} au) are particularly intriguing because their low binding energies make it difficult for the stars to stay gravitationally bound over extended timescales, and thus to probe the dynamics of binary formation and dissolution. Our previous SLoWPoKES catalogs, I and II, provided the largest and most complete sample of wide-binary pairs of low masses. Here we present an extension of these catalogs to a broad range of stellar masses: the Gaia Assorted Mass Binaries Long Excluded from SloWPoKES (GAMBLES), comprising 8660 statistically significant wide pairs that we make available in a living online database. Within this catalog we identify a subset of 543 long-lived (dissipation timescale >1.5 Gyr) candidate binary pairs, of assorted mass, with typical separations between 10{sup 3} and 10{sup 5.5} au (0.002–1.5 pc), using the published distances and proper motions from the Tycho -Gaia Astrometric Solution and Sloan Digital Sky Survey photometry. Each pair has at most a false positive probability of 0.05; the total expectation is 2.44 false binaries in our sample. Among these, we find 22 systems with 3 components, 1 system with 4 components, and 15 pairs consisting of at least 1 possible red giant. We find the largest long-lived binary separation to be nearly 3.2 pc; even so, >76% of GAMBLES long-lived binaries have large binding energies and dissipation lifetimes longer than 1.5 Gyr. Finally, we find that the distribution of binary separations is clearly bimodal, corroborating the findings from SloWPoKES and suggesting multiple pathways for the formation and dissipation of the widest binaries in the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Chitah: Strong-gravitational-lens hunter in imaging surveys

Strong gravitationally lensed quasars provide powerful means to study galaxy evolution and cosmology. Current and upcoming imaging surveys will contain thousands of new lensed quasars, augmenting the existing sample by at least two orders of magnitude. To find such lens systems, we built a robot, Chitah, that hunts for lensed quasars by modeling the configuration of the multiple quasar images.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid Response Radiation Sensors for Homeland Security Applications

The National Security Technologies, LLC, Remote Sensing Laboratory is developing a rapid response radiation detection system for homeland security field applications. The intelligence-driven system is deployed only when non-radiological information about the target is verifiable. The survey area is often limited, so the detection range is small; in most cases covering a distance of 10 meters or less suffices. Definitive response is required in no more than 3 seconds and should minimize false negative alarms, but can err on the side of positive false alarms. The detection system is rapidly reconfigurable in terms of size, shape, and outer appearance; it is a plug-and-play system. Multiple radiation detection components (viz., two or more sodium iodide scintillators) are used to independently “over-determine” the existence of the threat object. Rapid response electronic dose rate meters are also included in the equipment suite. Carefully studied threat signatures are the basis of the decision making. The use of Rad-Detect predictive modeling provides information on the nature of the threat object. Rad-Detect provides accurate dose rate from heavily shielded large sources; for example those lost in Mexico were Category 1 radiation sources (~3,000 Ci of 60Co), the most dangerous of five categories defined by the International Atomic Energy Agency. Taken out of their shielding containers, Category 1 sources can kill anyone who is exposed to them at close range for a few minutes to an hour. Whenever possible sub-second data acquisition will be attempted, and, when deployed, the system will be characterized for false alarm rates. Although the radiation detection materials selected are fast (viz., faster scintillators), their speed is secondary to sensitivity, which is of primary importance. Results from these efforts will be discussed and demonstrated.

gamma detector, false alarm rate, sub-second data ↗

Deep Imaging Search for Planets Forming in the TW Hya Protoplanetary Disk with the Keck/NIRC2 Vortex Coronagraph

Distinct gap features in the nearest protoplanetary disk, TW Hya (distance of 59.5 ± 0.9 pc), may be signposts of ongoing planet formation. We performed long-exposure thermal infrared coronagraphic imaging observations to search for accreting planets, especially within dust gaps previously detected in scattered light and submillimeter-wave thermal emission. Three nights of observations with the Keck/NIRC2 vortex coronagraph in L' (3.4–4.1 μm) did not reveal any statistically significant point sources. We thereby set strict upper limits on the masses of non-accreting planets. In the four most prominent disk gaps at 24, 41, 47, and 88 au, we obtain upper mass limits of 1.6–2.3, 1.1–1.6, 1.1–1.5, and 1.0–1.2 Jupiter masses (M {sub J}), assuming an age range of 7–10 Myr for TW Hya. These limits correspond to the contrast at 95% completeness (true positive fraction of 0.95) with a 1% chance of a false positive within 1" of the star. We also approximate an upper limit on the product of the planet mass and planetary accretion rate of M{sub p} M-dot ≲10{sup -8} M{sub J}{sup 2} yr{sup -1} implying that any putative ~0.1 M {sub J} planet, which could be responsible for opening the 24 au gap, is presently accreting at rates insufficient to build up a Jupiter mass within TW Hya’s pre-main-sequence lifetime.

79 ASTRONOMY AND ASTROPHYSICS↗

A Science-Focused Artificial Intelligence (AI) Responding in Real-Time to New Information: Capability Demonstration for Ocean World Missions

Introduction: Artificial intelligence (AI) has long been considered a potential mechanism to explore increasingly challenging environments, including those with extreme temperatures and pressures, limited communication capabilities, or those with demanding terrain. We posit that missions in extreme environments could deploy an onboard AI focused on science observations and goals in order to augment a traditional concept(s) of operations (ConOps). An onboard AI capability could perform functions such as data analysis in order to make high-level decisions, including prioritized data transmission for analysis by ground-based teams or autonomously-guided follow-on analyses that maximize science return. Such a capability would empower missions to respond to scientific data of interest in real-time; a mission could make observations and perform a preliminary analysis to alert ground-based scientists to an observation of interest, enabling an informed, rapid response from Earth-based teams. Enceladus Case Study for Onboard AI: We are developing an onboard AI capability for real-time telemetry response that formulates and carries-out informed decisions in service to established mission goals, enabling increased science return of a mission. We focus our AI development for use on a constellation of SmallSats orbiting Enceladus. Our Enceladus case study tests autonomous decision-making capabilities in scenarios with complex orbital dynamics, plume ejecta, extreme cold environments, power restrictions, and a requirement to maximize science return for a potential positive detection of life, while critically evaluating the potential for false positives. Telemetry includes simulated scientific data, spacecraft onboard operational data (e.g., position, velocity, and rotation), and engineering hardware performance data. Enceladus SmallSat Constellation. Our constellation includes eight SmallSat spacecraft in an 8:35 resonant orbit-based formation, leveraging Saturn’s gravitational forces to maintain stable orbits with global coverage around Enceladus. To our knowledge, we simulate the first stable configuration of multiple spacecraft in closed orbits around Enceladus, using a full ephemeris force model (Russell and Lara, 2009). Each spacecraft’s orbit will precess, causing an eastward ground track shift (from an orbiter’s perspective) of each spacecraft for each orbit. However, all spacecraft return to their original positions relative to Enceladus after eight Enceladus revolutions around Saturn. We model communication pathways between SmallSats to understand how information would need to be transmitted across the constellation to enable AI-driven decision-making and resource allocation across the fleet. Capability Demonstration. Our simulated capability demonstration inputs position, velocity, and rotation telemetry from our Enceladus-focused constellation simulations, and mass spectrometry data collected from abiotic and biotic laboratory-analog ocean world experiments (Theiling et al., 2018; Theiling, 2021; Da Poian et al., 2023). Data from these experiments are used to simulate MS measurements and different scenarios of science observations for onboard analysis performed on each of the eight spacecraft. For these demonstrations, we integrate 24 machine learning (ML) algorithms into an onboard intelligence as a ‘knowledge base’, including algorithms evaluating data quality and those predicting (with % confidence) gas composition, ocean aqueous chemistry, and whether the sample was influenced by microbial life. The onboard AI capability is designed to use the knowledge base to come to a consensus-based decision in the interpretation of the observed data in order to request additional action outside of a pre-defined ConOps. Requested actions could include e.g., prioritized downlink to Earth (for analysis by ground-based teams) or follow-on analyses performed across the constellation. The spacecraft’s intelligent onboard planner must then determine whether sufficient resources (e.g., time, power, etc.) are available and weigh the request with mission priorities. In our simulation, the constellation is able to identify potential biosignatures using onboard ML algorithms, evaluate the confidence of that prediction, and perform follow-on analyses across the fleet to confirm the detection, in order to best prepare a transmission of these data to Earth-based teams.

astrobiology↗

Increased Detection of Lymphatic Vessel Invasion by D2-40 (Podoplanin) in Early Breast Cancer: Possible Influence on Patient Selection for Accelerated Partial Breast Irradiation

Purpose: Several international trials are currently investigating accelerated partial breast irradiation (APBI) for patients with early-stage breast cancer. According to existing guidelines, patients with lymphatic vessel invasion (LVI) do not qualify for APBI. D2-40 (podoplanin) significantly increases the frequency of LVI detection compared with conventional hematoxylin and eosin (HE) staining in early-stage breast cancer. Our purpose was to retrospectively assess the hypothetical change in management from APBI to whole breast radiotherapy with the application of D2-40. Patients and Methods: Immunostaining with D2-40 was performed on 254 invasive breast tumors of 247 patients. The following criteria were used to determine the eligibility for APBI: invasive ductal adenocarcinoma of {<=}3 cm, negative axillary node status (N0), and unifocal disease. Of the 247 patients, 74 with available information concerning LVI, as detected by D2-40 immunostaining and routine HE staining, formed our study population. Results: Using D2-40, our results demonstrated a significantly greater detection rate (p = .031) of LVI compared with routine HE staining. LVI was correctly identified by D2-40 (D2-40-positive LVI) in 10 (13.5%) of 74 tumors. On routine HE staining, 4 tumors (5.4%) were classified as HE-positive LVI. Doublestaining of these specimens with D2-40 unmasked false-positive LVI status in 2 (50%) of the 4 tumors. According to the current recommendations for APBI, immunostaining with D2-40 would have changed the clinical management from APBI to whole breast radiotherapy in 8 (10.8%) of 74 patients and from whole breast radiotherapy to APBI in 2 patients (2.7%). Conclusion: These data support the implementation of D2-40 immunostaining in the routine workup to determine a patient's eligibility for APBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical change detection of building energy consumption: Applications to savings estimation

The surge in interval meter data availability and associated activity in energy data analytics has inspired new interest in advanced methods for building efficiency savings estimation. Statistical and machine learning approaches are being explored to improve the energy baseline models used to measure and verify savings. One outstanding challenge is the ability to identify and account for operational changes that may confound savings estimates. In the measurement and verification (M&V) context, ‘non-routine events’ (NREs) cause changes in building energy use that are not attributable to installed efficiency measures, and not accounted for in the baseline model’s independent variables. In the M&V process NREs must be accounted for as ‘adjustments’ to appropriately attribute the estimated energy savings to the specific efficiency interventions that were implemented. Currently this is a manual and custom process, conducted using professional judgment and engineering expertise. As such it remains a barrier in scaling and standardizing meter-based savings estimation. Here in this work, a data driven methodology was developed to (partially) automate, and therefore streamline the process of detecting NREs in the post-retrofit period and making associated savings adjustments. The proposed NRE detection algorithm is based on a statistical change point detection method and a dissimilarity metric. The dissimilarity metric measures the proximity between the actual time series of the post-retrofit energy consumption and the projected baseline, which is generated using a statistical baseline model. The suggested approach for NRE adjustment involves the NRE detection algorithm, the M&V practitioner, and a regression modeling algorithm. The performance of the detection and adjustment algorithm was evaluated using a simulation-generated test data set, and two benchmark algorithms. Results show a high true positive detection rate (75%-100% across the test cases), higher than ideal false positive detection rates (20%-70%), and low errors in energy adjustment (<0.7%). These results indicate that the algorithm holds for helping M&V practitioners to streamline the process of handling NREs. Moreover, the change point algorithm and underlying statistical principles could prove valuable for other building analytics applications such as anomaly detection and fault diagnostics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utility of PET/CT Imaging Performed Early After Surgical Resection in the Adjuvant Treatment Planning for Head and Neck Cancer

Purpose: To evaluate the utility of positron emission tomography (PET)/computed tomography (CT) early after surgical resection and before postoperative adjuvant radiation therapy. Methods and Materials: We studied a prospective cohort of 91 consecutive patients referred for postoperative adjuvant radiation therapy after complete surgical resection. Tumor histologies included 62 squamous cell and 29 non-squamous cell cancers. Median time between surgery and postoperative PET/CT was 28 days (range, 13-75 days). Findings suspicious for persistent/recurrent cancer or distant metastasis were biopsied. Correlation was made with changes in patient care. Results: Based on PET/CT findings, 24 patients (26.4%) underwent biopsy of suspicious sites. Three patients with suspicious findings did not undergo biopsy because the abnormalities were not easily accessible. Eleven (45.8%) biopsies were positive for cancer. Treatment was changed for 14 (15.4%) patients (11 positive biopsy and 3 nonbiopsied patients) as a result. Treatment changes included abandonment of radiation therapy and switching to palliative chemotherapy or hospice care (4), increasing the radiation therapy dose (6), extending the radiation therapy treatment volume and increasing the dose (1), additional surgery (2), and adding palliative chemotherapy to palliative radiation therapy (1). Treatment for recurrent cancer and primary skin cancer were significant predictors of having a biopsy-proven, treatment-changing positive PET/CT (p < 0.03). Conclusions: Even with an expectedly high rate of false positive PET/CT scans in this early postoperative period, PET/CT changed patient management in a relatively large proportion of patients. PET/CT can be recommended in the postoperative, preradiation therapy setting with the understanding that treatment-altering PET/CT findings should be biopsied for confirmation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Immunoassays and General Biological Indicator Tests for Field Screening of Bacillus anthracis and Ricin

The goal of this testing was to evaluate the ability of currently available commercial off-the-shelf (COTS) biological indicator tests and immunoassays to detect Bacillus anthracis (Ba) spores and ricin. In general, immunoassays provide more specific identification of biological threats as compared to indicator tests [3]. Many of these detection products are widely used by first responders and other end users. In most cases, performance data for these instruments are supplied directly from the manufacturer, but have not been verified by an external, independent assessment [1]. Our test plan modules included assessments of inclusivity (ability to generate true positive results), commonly encountered hoax powders (which can cause potential interferences or false positives), and estimation of limit of detection (LOD) (sensitivity) testing.

59 BASIC BIOLOGICAL SCIENCES↗

CHARACTERIZING THE COOL KOIs. IV. KEPLER-32 AS A PROTOTYPE FOR THE FORMATION OF COMPACT PLANETARY SYSTEMS THROUGHOUT THE GALAXY

The Kepler space telescope has opened new vistas in exoplanet discovery space by revealing populations of Earth-sized planets that provide a new context for understanding planet formation. Approximately 70% of all stars in the Galaxy belong to the diminutive M dwarf class, several thousand of which lie within Kepler's field of view, and a large number of these targets show planet transit signals. The Kepler M dwarf sample has a characteristic mass of 0.5 M {sub Sun} representing a stellar population twice as common as Sun-like stars. Kepler-32 is a typical star in this sample that presents us with a rare opportunity: five planets transit this star, giving us an expansive view of its architecture. All five planets of this compact system orbit their host star within a distance one-third the size of Mercury's orbit, with the innermost planet positioned a mere 4.3 stellar radii from the stellar photosphere. New observations limit possible false positive scenarios, allowing us to validate the entire Kepler-32 system making it the richest known system of transiting planets around an M dwarf. Based on considerations of the stellar dust sublimation radius, a minimum mass protoplanetary nebula, and the near period commensurability of three adjacent planets, we propose that the Kepler-32 planets formed at larger orbital radii and migrated inward to their present locations. The volatile content inferred for the Kepler-32 planets and order of magnitude estimates for the disk migration rates suggest that these planets may have formed beyond the snow line and migrated in the presence of a gaseous disk. If true, then this would place an upper limit on their formation time of {approx}10 Myr. The Kepler-32 planets are representative of the full ensemble of planet candidates orbiting the Kepler M dwarfs for which we calculate an occurrence rate of 1.0 {+-} 0.1 planet per star. The formation of the Kepler-32 planets therefore offers a plausible blueprint for the formation of one of the largest known populations of planets in our Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

PILOT-SCALE FIELD VALIDATION OF THE LONG ELECTRODE ELECTRICAL RESISTIVITY TOMOGRAPHY METHOD

Field validation for the long electrode electrical resistivity tomography (LE-ERT) method was attempted in order to demonstrate the performance of the technique in imaging a simple buried target. The experiment was an approximately 1/17 scale mock-up of a region encompassing a buried nuclear waste tank on the Hanford site. The target of focus was constructed by manually forming a simulated plume within the vadose zone using a tank waste simulant. The LE-ERT results were compared to ERT using conventional point electrodes on the surface and buried within the survey domain. Using a pole-pole array, both point and long electrode imaging techniques identified the lateral extents of the pre-formed plume with reasonable fidelity, but the LE-ERT was handicapped in reconstructing the vertical boundaries. The pole-dipole and dipole-dipole arrays were also tested with the LE-ERT method and were shown to have the least favorable target properties, including the position of the reconstructed plume relative to the known plume and the intensity of false positive targets. The poor performance of the pole-dipole and dipole-dipole arrays was attributed to an inexhaustive and non-optimal coverage of data at key electrodes, as well as an increased noise for electrode combinations with high geometric factors. However, when comparing the model resolution matrix among the different acquisition strategies, the pole-dipole and dipole-dipole arrays using long electrodes were shown to have significantly higher average and maximum values than any pole-pole array. The model resolution describes how well the inversion model resolves the subsurface. Given the model resolution performance of the pole-dipole and dipole-dipole arrays, it may be worth investing in tools to understand the optimum subset of randomly distributed electrode pairs to produce maximum performance from the inversion model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged across all simulations and phase bins, respiratory-gating reduced overall thoracic MSE by 46% compared to conventional 4D CT (p ∼ 10{sup −19}). Gating leads to small but significant (p < 0.02) reductions in lung volume errors (1.8%–1.4%), false positives (4.0%–2.6%), and false negatives (2.7%–1.3%). These percentage reductions correspond to gating reducing image artifacts by 24–90 cm{sup 3} of lung tissue. Similar to earlier studies, gating reduced patient image dose by up to 22%, but with scan time increased by up to 135%. Beam paused 4D CT did not significantly impact normal lung tissue image quality, but did yield similar dose reductions as for respiratory-gating, without the added cost in scanning time. Conclusions: For a typical 6 L lung, respiratory-gated 4D CT can reduce image artifacts affecting up to 90 cm{sup 3} of normal lung tissue compared to conventional acquisition. This image improvement could have important implications for dose calculations based on 4D CT. Where image quality is less critical, beam paused 4D CT is a simple strategy to reduce imaging dose without sacrificing acquisition time.

60 APPLIED LIFE SCIENCES↗