Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

SU-G-BRB-11: On the Sensitivity of An EPID-Based 3D Dose Verification System to Detect Delivery Errors in VMAT Treatments

Purpose: To investigate the sensitivity of an EPID-based 3D dose verification system to detect delivery errors in VMAT treatments. Methods: For this study 41 EPID-reconstructed 3D in vivo dose distributions of 15 different VMAT plans (H&N, lung, prostate and rectum) were selected. To simulate the effect of delivery errors, their TPS plans were modified by: 1) scaling of the monitor units by ±3% and ±6% and 2) systematic shifting of leaf bank positions by ±1mm, ±2mm and ±5mm. The 3D in vivo dose distributions where then compared to the unmodified and modified treatment plans. To determine the detectability of the various delivery errors, we made use of a receiver operator characteristic (ROC) methodology. True positive and false positive rates were calculated as a function of the γ-parameters γmean, γ1% (near-maximum γ) and the PTV dose parameter ΔD{sub 50} (i.e. D{sub 50}(EPID)-D{sub 50}(TPS)). The ROC curve is constructed by plotting the true positive rate vs. the false positive rate. The area under the ROC curve (AUC) then serves as a measure of the performance of the EPID dosimetry system in detecting a particular error; an ideal system has AUC=1. Results: The AUC ranges for the machine output errors and systematic leaf position errors were [0.64 – 0.93] and [0.48 – 0.92] respectively using γmean, [0.57 – 0.79] and [0.46 – 0.85] using γ1% and [0.61 – 0.77] and [ 0.48 – 0.62] using ΔD{sub 50}. Conclusion: For the verification of VMAT deliveries, the parameter γmean is the best discriminator for the detection of systematic leaf position errors and monitor unit scaling errors. Compared to γmean and γ1%, the parameter ΔD{sub 50} performs worse as a discriminator in all cases.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-06: Electromagnetic Beacon Insertion in Lung Cancer Patients and Resultant Surrogacy Errors for Dynamic MLC Tumour Tracking

Purpose: To assess endo-bronchial electromagnetic beacon insertion and to quantify the geometric accuracy of using beacons as a surrogate for tumour motion in real-time multileaf collimator (MLC) tracking of lung tumours. Methods: The LIGHT SABR trial is a world-first clinical trial in which the MLC leaves move with lung tumours in real time on a standard linear accelerator. Tracking is performed based on implanted electromagnetic beacons (CalypsoTM, Varian Medical Systems, USA) as a surrogate for tumour motion. Five patients have been treated and have each had three beacons implanted endo-bronchially under fluoroscopic guidance. The centre of mass (C.O.M) has been used to adapt the MLC in real-time. The geometric error in using the beacon C.O.M as a surrogate for tumour motion was measured by measuring the tumour and beacon C.O.M in all phases of the respiratory cycle of a 4DCT. The surrogacy error was defined as the difference in beacon and tumour C.O.M relative to the reference phase (maximum exhale). Results: All five patients have had three beacons successfully implanted with no migration between simulation and end of treatment. Beacon placement relative to tumour C.O.M varied from 14 to 74 mm and in one patient spanned two lobes. Surrogacy error was measured in each patient on the simulation 4DCT and ranged from 0 to 3 mm. Surrogacy error as measured on 4DCT was subject to artefacts in mid-ventilation phases. Surrogacy error was a function of breathing phase and was typically larger at maximum inhale. Conclusion: Beacon placement and thus surrogacy error is a major component of geometric uncertainty in MLC tracking of lung tumours. Surrogacy error must be measured on each patient and incorporated into margin calculation. Reduction of surrogacy error is limited by airway anatomy, however should be taken into consideration when performing beacon insertion and planning. This research is funded by Varian Medical Systems via a collaborative research agreement.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-05: Identifying Treatment Planning System Errors in IROC-H Phantom Irradiations

Purpose: Treatment Planning System (TPS) errors can affect large numbers of cancer patients receiving radiation therapy. Using an independent recalculation system, the Imaging and Radiation Oncology Core-Houston (IROC-H) can identify institutions that have not sufficiently modelled their linear accelerators in their TPS model. Methods: Linear accelerator point measurement data from IROC-H’s site visits was aggregated and analyzed from over 30 linear accelerator models. Dosimetrically similar models were combined to create “classes”. The class data was used to construct customized beam models in an independent treatment dose verification system (TVS). Approximately 200 head and neck phantom plans from 2012 to 2015 were recalculated using this TVS. Comparison of plan accuracy was evaluated by comparing the measured dose to the institution’s TPS dose as well as the TVS dose. In cases where the TVS was more accurate than the institution by an average of >2%, the institution was identified as having a non-negligible TPS error. Results: Of the ∼200 recalculated plans, the average improvement using the TVS was ∼0.1%; i.e. the recalculation, on average, slightly outperformed the institution’s TPS. Of all the recalculated phantoms, 20% were identified as having a non-negligible TPS error. Fourteen plans failed current IROC-H criteria; the average TVS improvement of the failing plans was ∼3% and 57% were found to have non-negligible TPS errors. Conclusion: IROC-H has developed an independent recalculation system to identify institutions that have considerable TPS errors. A large number of institutions were found to have non-negligible TPS errors. Even institutions that passed IROC-H criteria could be identified as having a TPS error. Resolution of such errors would improve dose delivery for a large number of IROC-H phantoms and ultimately, patients.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP3-01: A Statistical Model for Analyzing the Rotational Error of Single Iso-Center Technique

Purpose: To develop a generalized statistical model that incorporates the treatment uncertainty from the rotational error of single iso-center technique, and calculate the additional PTV (planning target volume) margin required to compensate for this error. Methods: The random vectors for setup and additional rotation errors in the three-dimensional (3D) patient coordinate system were assumed to follow the 3D independent normal distribution with zero mean, and standard deviations σx, σy, σz, for setup error and a uniform σR for rotational error. Both random vectors were summed, normalized and transformed to the spherical coordinates to derive the chi distribution with 3 degrees of freedom for the radical distance ρ. PTV margin was determined using the critical value of this distribution for 0.05 significant level so that 95% of the time the treatment target would be covered by ρ. The additional PTV margin required to compensate for the rotational error was calculated as a function of σx, σy, σz and σR. Results: The effect of the rotational error is more pronounced for treatments that requires high accuracy/precision like stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT). With a uniform 2mm PTV margin (or σx =σy=σz=0.7mm), a σR=0.32mm will decrease the PTV coverage from 95% to 90% of the time, or an additional 0.2mm PTV margin is needed to prevent this loss of coverage. If we choose 0.2 mm as the threshold, any σR>0.3mm will lead to an additional PTV margin that cannot be ignored, and the maximal σR that can be ignored is 0.0064 rad (or 0.37°) for iso-to-target distance=5cm, or 0.0032 rad (or 0.18°) for iso-to-target distance=10cm. Conclusions: The rotational error cannot be ignored for high-accuracy/-precision treatments like SRS/SBRT, particularly when the distance between the iso-center and target is large.

60 APPLIED LIFE SCIENCES↗

WE-AB-209-01: A Monte Carlo-Based Method to Include Random Errors in Robust Optimization

Purpose: To develop an efficient method to implement random set-up errors and organ motion in robust optimization for proton therapy treatment planning. Methods: The plans were created with an in-house robust optimizer, coupled with a super-fast Monte Carlo (MC) engine (less than 1 minute for final dose). MC simulates random errors by shifting randomly the starting point of each particle, according to their probability distribution. Such strategy assumes a sufficient number of treatment fractions. Two strategies are presented: 1) Full robust optimization with beamlets that already include the effect of random errors and 2) Mixed robust optimization, where the nominal beamlets are involved but a correction term C modifies the prescription. Starting from C=0, the method alternates optimization of the spot weights with the nominal beamlets and updates of C, with C=Drandom-Dnominal and where Drandom results from a regular MC computation (without pre-computed beamlets) that simulates random errors. Updates of C can be triggered as often as necessary by running the MC engine with the last corrected values for the spot weights as input. The method was applied to lung and prostate cases. For both patients the range error was set to 3%, systematic setup error to 5mm and standard deviation for random errors to 5 mm. Comparison between full robust optimization and the mixed strategy (with 3 updates of C) is presented. Results: Target coverage was far below the clinical constraints (D{sub 95} > 95% of the prescribed dose) for plans where random errors were not simulated, especially for lung case. However, by using the proposed strategies the plans achieved a target coverage above clinical constraints. Conclusion: Full robust optimization gives better results than the mixed strategy, but the latter can be useful in cases where a MC engine is not available or too computationally intensive for beamlets calculation.

60 APPLIED LIFE SCIENCES↗

WE-H-BRC-05: Catastrophic Error Metrics for Radiation Therapy

Purpose: Intuitive evaluation of complex radiotherapy treatments is impractical, while data transfer anomalies create the potential for catastrophic treatment delivery errors. Contrary to prevailing wisdom, logical scrutiny can be applied to patient-specific machine settings. Such tests can be automated, applied at the point of treatment delivery and can be dissociated from prior states of the treatment plan, potentially revealing errors introduced early in the process. Methods: Analytical metrics were formulated for conventional and intensity modulated RT (IMRT) treatments. These were designed to assess consistency between monitor unit settings, wedge values, prescription dose and leaf positioning (IMRT). Institutional metric averages for 218 clinical plans were stratified over multiple anatomical sites. Treatment delivery errors were simulated using a commercial treatment planning system and metric behavior assessed via receiver-operator-characteristic (ROC) analysis. A positive result was returned if the erred plan metric value exceeded a given number of standard deviations, e.g. 2. The finding was declared true positive if the dosimetric impact exceeded 25%. ROC curves were generated over a range of metric standard deviations. Results: Data for the conventional treatment metric indicated standard deviations of 3%, 12%, 11%, 8%, and 5 % for brain, pelvis, abdomen, lung and breast sites, respectively. Optimum error declaration thresholds yielded true positive rates (TPR) between 0.7 and 1, and false positive rates (FPR) between 0 and 0.2. Two proposed IMRT metrics possessed standard deviations of 23% and 37%. The superior metric returned TPR and FPR of 0.7 and 0.2, respectively, when both leaf position and MUs were modelled. Isolation to only leaf position errors yielded TPR and FPR values of 0.9 and 0.1. Conclusion: Logical tests can reveal treatment delivery errors and prevent large, catastrophic errors. Analytical metrics are able to identify errors in monitor units, wedging and leaf positions with favorable sensitivity and specificity. In part by Varian.

60 APPLIED LIFE SCIENCES↗

Technical Note: Introduction of variance component analysis to setup error analysis in radiotherapy

Purpose: The purpose of this technical note is to introduce variance component analysis to the estimation of systematic and random components in setup error of radiotherapy. Methods: Balanced data according to the one-factor random effect model were assumed. Results: Analysis-of-variance (ANOVA)-based computation was applied to estimate the values and their confidence intervals (CIs) for systematic and random errors and the population mean of setup errors. The conventional method overestimates systematic error, especially in hypofractionated settings. The CI for systematic error becomes much wider than that for random error. The ANOVA-based estimation can be extended to a multifactor model considering multiple causes of setup errors (e.g., interpatient, interfraction, and intrafraction). Conclusions: Variance component analysis may lead to novel applications to setup error analysis in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Estimating Aboveground Biomass in Tropical Forests: Field Methods and Error Analysis for the Calibration of Remote Sensing Observations

Mapping and monitoring of forest carbon stocks across large areas in the tropics will necessarily rely on remote sensing approaches, which in turn depend on field estimates of biomass for calibration and validation purposes. Here, we used field plot data collected in a tropical moist forest in the central Amazon to gain a better understanding of the uncertainty associated with plot-level biomass estimates obtained specifically for the calibration of remote sensing measurements. In addition to accounting for sources of error that would be normally expected in conventional biomass estimates (e.g., measurement and allometric errors), we examined two sources of uncertainty that are specific to the calibration process and should be taken into account in most remote sensing studies: the error resulting from spatial disagreement between field and remote sensing measurements (i.e., co-location error), and the error introduced when accounting for temporal differences in data acquisition. We found that the overall uncertainty in the field biomass was typically 25% for both secondary and primary forests, but ranged from 16 to 53%. Co-location and temporal errors accounted for a large fraction of the total variance (>65%) and were identified as important targets for reducing uncertainty in studies relating tropical forest biomass to remotely sensed data. Although measurement and allometric errors were relatively unimportant when considered alone, combined they accounted for roughly 30% of the total variance on average and should not be ignored. Lastly, our results suggest that a thorough understanding of the sources of error associated with field-measured plot-level biomass estimates in tropical forests is critical to determine confidence in remote sensing estimates of carbon stocks and fluxes, and to develop strategies for reducing the overall uncertainty of remote sensing approaches.

54 ENVIRONMENTAL SCIENCES↗

Wavefront-Error Performance Characterization for the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Science Instruments

The science instruments (SIs) comprising the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) were tested in three cryogenic-vacuum test campaigns in the NASA Goddard Space Flight Center (GSFC)'s Space Environment Simulator (SES). In this paper, we describe the results of optical wavefront-error performance characterization of the SIs. The wavefront error is determined using image-based wavefront sensing (also known as phase retrieval), and the primary data used by this process are focus sweeps, a series of images recorded by the instrument under test in its as-used configuration, in which the focal plane is systematically changed from one image to the next. High-precision determination of the wavefront error also requires several sources of secondary data, including 1) spectrum, apodization, and wavefront-error characterization of the optical ground-support equipment (OGSE) illumination module, called the OTE Simulator (OSIM), 2) plate scale measurements made using a Pseudo-Nonredundant Mask (PNRM), and 3) pupil geometry predictions as a function of SI and field point, which are complicated because of a tricontagon-shaped outer perimeter and small holes that appear in the exit pupil due to the way that different light sources are injected into the optical path by the OGSE. One set of wavefront-error tests, for the coronagraphic channel of the Near-Infrared Camera (NIRCam) Longwave instruments, was performed using data from transverse translation diversity sweeps instead of focus sweeps, in which a sub-aperture is translated andor rotated across the exit pupil of the system.Several optical-performance requirements that were verified during this ISIM-level testing are levied on the uncertainties of various wavefront-error-related quantities rather than on the wavefront errors themselves. This paper also describes the methodology, based on Monte Carlo simulations of the wavefront-sensing analysis of focus-sweep data, used to establish the uncertainties of the wavefront error maps.

wavefront error↗

Wavefront-Error Performance Characterization for the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Science Instruments

The science instruments (SIs) comprising the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) were tested in three cryogenic-vacuum test campaigns in the NASA Goddard Space Flight Center (GSFC)'s Space Environment Simulator (SES) test chamber. In this paper, we describe the results of optical wavefront-error performance characterization of the SIs. The wavefront error is determined using image-based wavefront sensing, and the primary data used by this process are focus sweeps, a series of images recorded by the instrument under test in its as-used configuration, in which the focal plane is systematically changed from one image to the next. High-precision determination of the wavefront error also requires several sources of secondary data, including 1) spectrum, apodization, and wavefront-error characterization of the optical ground-support equipment (OGSE) illumination module, called the OTE Simulator (OSIM), 2) F-number and pupil-distortion measurements made using a pseudo-nonredundant mask (PNRM), and 3) pupil geometry predictions as a function of SI and field point, which are complicated because of a tricontagon-shaped outer perimeter and small holes that appear in the exit pupil due to the way that different light sources are injected into the optical path by the OGSE. One set of wavefront-error tests, for the coronagraphic channel of the Near-Infrared Camera (NIRCam) Longwave instruments, was performed using data from transverse translation diversity sweeps instead of focus sweeps, in which a sub-aperture is translated and/or rotated across the exit pupil of the system. Several optical-performance requirements that were verified during this ISIM-level testing are levied on the uncertainties of various wavefront-error-related quantities rather than on the wavefront errors themselves. This paper also describes the methodology, based on Monte Carlo simulations of the wavefront-sensing analysis of focus-sweep data, used to establish the uncertainties of the wavefront-error maps.

image analysis↗

Influence of Strain-Gage Balance Characteristics on the Precision Error of the Drag Coefficient

Improvements and results of a new method are presented that computes a pre-test estimate of the precision error of the drag coefficient of a wind tunnel model. The error estimate is defined as the part of the drag coefficient's precision error that is primarily associated with the precision error of the angle of attack measurement and physical characteristics of the chosen strain-gage balance. The method indirectly describes the precision error of the angle of attack measurement by using an assumed balance gage output variation of one microV/V. The physical characteristics of the balance, on the other hand, are described by partial derivatives of the axial and normal forces with respect to the strain-gage outputs. These derivatives can directly be obtained from the data reduction matrix of the balance. The precision error estimate itself is calculated by applying a simple explicit equation that uses the model reference area, the dynamic pressure, the angle of attack, the coefficients of the linear terms of the data reduction matrix, and the electrical output variation of one microvolt per volt as input. Precision errors at constant angle of attack may be visualized as contour plots by plotting them, for example, versus the Mach number and the total pressure. Characteristics of NASA's MC60E balance are used in combination with the reference area of a generic wind tunnel model in order to demonstrate that error estimates are independent of both the balance load format and the units chosen for the description of balance loads, model reference area, and the dynamic pressure. Finally, experimental data from a wind tunnel test of the Ames Check Standard Model in the NASA Ames 11-foot Transonic Wind Tunnel illustrates the application of the method to real-world test data.

precision error↗

Characterization of the Impact of Soft Errors on Iterative Methods

Soft errors caused by transient bit flips have the potential to significantly impact an application’s behavior. This has motivated the design of an array of techniques to detect, isolate, and correct soft errors using microarchitectural, architectural, compilation-based, or application-level techniques to minimize their impact on the executing application. The first step towards the design of good error detection/correction techniques involves an understanding of an application’s vulnerability to soft errors. In this paper, we present the first comprehensive characterization of the impact of soft errors on the convergence characteristics of six iterative methods using application-level fault injection. In particular, we consider the use of iterative methods to incrementally solve a linear systems of equations, which constitutes the core kernel in many scientific applications. We analyze the impact of soft errors in terms of the type of error (single- vs multi-bit), the distribution and location of bits affected, the data structure and the statement impacted, and variation with time. In addition to understanding the vulnerability of iterative solvers to soft errors, this characterization can aid the design of fault injection campaigns that ensure systematic coverage.

fault injection, iterative methods, Silent data co↗

State Space Truncation with Quantified Errors for Accurate Solutions to Discrete Chemical Master Equation

The discrete chemical master equation (dCME) provides a general framework for studying stochasticity in mesoscopic reaction networks. Since its direct solution rapidly becomes intractable due to the increasing size of the state space, truncation of the state space is necessary for solving most dCMEs. It is therefore important to assess the consequences of state space truncations so errors can be quantified and minimized. Here we describe a novel method for state space truncation. By partitioning a reaction network into multiple molecular equivalence groups (MEGs), we truncate the state space by limiting the total molecular copy numbers in each MEG. We further describe a theoretical framework for analysis of the truncation error in the steady-state probability landscape using reflecting boundaries. By aggregating the state space based on the usage of a MEG and constructing an aggregated Markov process, we show that the truncation error of a MEG can be asymptotically bounded by the probability of states on the reflecting boundary of the MEG. Furthermore, truncating states of an arbitrary MEG will not undermine the estimated error of truncating any other MEGs. We then provide an overall error estimate for networks with multiple MEGs. To rapidly determine the appropriate size of an arbitrary MEG, we also introduce an a priori method to estimate the upper bound of its truncation error. This a priori estimate can be rapidly computed from reaction rates of the network, without the need of costly trial solutions of the dCME. As examples, we show results of applying our methods to the four stochastic networks of (1) the birth and death model, (2) the single gene expression model, (3) the genetic toggle switch model, and (4) the phage lambda bistable epigenetic switch model. We demonstrate how truncation errors and steady-state probability landscapes can be computed using different sizes of the MEG(s) and how the results validate our theories. Overall, the novel state space truncation and error analysis methods developed here can be used to ensure accurate direct solutions to the dCME for a large number of stochastic networks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Case for Soft Error Detection and Correction in Computational Chemistry

High performance computing platforms are expected to deliver 10(18) floating operations per second by the year 2022 through the deployment of millions of cores. Even if every core is highly reliable the sheer number of the them will mean that the mean time between failures will become so short that most applications runs will suffer at least one fault. In particular soft errors caused by intermittent incorrect behavior of the hardware are a concern as they lead to silent data corruption. In this paper we investigate the impact of soft errors on optimization algorithms using Hartree-Fock as a particular example. Optimization algorithms iteratively reduce the error in the initial guess to reach the intended solution. Therefore they may intuitively appear to be resilient to soft errors. Our results show that this is true for soft errors of small magnitudes but not for large errors. We suggest error detection and correction mechanisms for different classes of data structures. The results obtained with these mechanisms indicate that we can correct more than 95% of the soft errors at moderate increases in the computational cost.

Computational chemistry↗

An effective approach for the minimization of errors in capacitance-voltage carrier profiling of quantum structures

Experimental capacitance–voltage (C-V) profiling of semiconductor heterojunctions and quantum wells has remained ever important and relevant. The apparent carrier distributions (ACDs) thus obtained reveal the carrier depletions, carrier peaks and their positions, in and around the quantum structures. Inevitable errors, encountered in such measurements, are the deviations of the peak concentrations of the ACDs and their positions, from the actual carrier peaks obtained from quantum mechanical computations with the fundamental parameters. In spite of the very wide use of the C-V method, comprehensive discussions on the qualitative and quantitative nature of the errors remain wanting. The errors are dependent on the fundamental parameters, the temperature of measurements, the Debye length, and the series resistance. In this paper, the errors have been studied with doping concentration, band offset, and temperature. From this study, a rough estimate may be drawn about the error. It is seen that the error in the position of the ACD peak decreases at higher doping, higher band offset, and lower temperature, whereas the error in the peak concentration changes in a strange fashion. A completely new method is introduced, for derivation of the carrier profiles from C-V measurements on quantum structures to minimize errors which are inevitable in the conventional formulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Error-correcting Bacon-Shor code with continuous measurement of noncommuting operators

We analyze the continuous operation of the nine-qubit error correcting Bacon-Shor code with all noncommuting gauge operators measured at the same time. The error syndromes are continuously monitored using cross-correlations of sets of three measurement signals. We calculate the logical error rates due to $X$, $Y$ and $Z$ errors in the physical qubits and compare the continuous implementation with the discrete operation of the code. We find that both modes of operation exhibit similar performances when the measurement strength from continuous measurements is sufficiently strong. Here, we also estimate the value of the crossover error rate of the physical qubits, below which continuous error correction gives smaller logical error rates. Continuous operation has the advantage of passive monitoring of errors and avoids the need for additional circuits involving ancilla qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Understanding the Interplay between Hardware Errors and User Job Characteristics on the Titan Supercomputer

Designing dependable supercomputers begins with an understanding of errors in real-world, large-scale systems. The Titan supercomputer at Oak Ridge National Laboratory provides a unique opportunity to investigate errors when an actual system is actively used by multiple concurrent users and workloads from diverse domains at varying scales. This study presents a thorough analysis of 6, 908, 497 hardware errors from 18, 688 compute nodes of Titan for 312, 215 user jobs over a 3-year time period. Through careful joining of two system logs – the Machine Check Architecture (MCA) log and the job scheduler log – we show the correlated pattern of hardware errors for each job and user, in addition to individual descriptive statistics of errors, jobs, and users. Since the majority of hardware errors are memory errors, this study also shows the importance of error correcting in memory systems.

Lim, Seung-Hwan↗

High Impedance Fault Detection Through Quasi-Static State Estimation: A Parameter Error Modeling Approach

This paper presents a model for detecting high impedance faults using parameter error modeling and a two step per-phase weighted-least squares state estimation process. The proposed scheme leverages the use of Phasor Measurement Units and synthetic measurements to identify per-phase power flow and injection measurements which indicate a parameter error through ?2 Hypothesis Testing applied to the composed measurement error. Although current and voltage waveforms are commonly analyzed for high-impedance fault detection, wide area power flow and injection measurements, which are already inherent to the state estimation process, also show promise for real-world high-impedance fault detection applications. The error distributions after detection share the measurement function error spread observed in proven parameter error diagnostics and can be applied to high-impedance fault identification. Further, this error spread across measurement functions related to the fault will be clearly discerned from measurement error. Case studies are performed on the IEEE 33-Bus Distribution System along with the proposed model in Simulink.

Cooper, Austin↗