Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Formation of Carbon Nanotube Based Gears: Quantum Chemistry and Molecular Mechanics Study of the Electrophilic Addition of o-Benzyne to Fullerenes, Graphene, and Nanotubes

Considerable progress has been made in recent years in chemical functionalization of fullerene molecules. In some cases, the predominant reaction products are different from those obtained (using the same reactants) from polycyclic aromatic hydrocarbons (PAHs). One such example is the cycloaddition of o-benzyne to C60. It is well established that benzyne adds across one of the rings in naphthalene, anthracene and other PAHs forming the [2+4] cycloaddition product (benzobicyclo[2.2.2.]-octatriene with naphthalene and triptycene with anthracene). However, Hoke et al demonstrated that the only reaction path for o-benzyne with C60 leads to the [2+2] cycloaddition product in which benzyne adds across one of the interpentagonal bonds (forming a cyclobutene ring in the process). Either reaction product results in a loss of aromaticity and distortion of the PAH or fullerene substrate, and in a loss of strain in the benzyne. It is not clear, however, why different products are preferred in these cases. In the current paper, we consider the stability of benzyne-nanotube adducts and the ability of Brenner's potential energy model to describe the structure and stability of these adducts. The Brenner potential has been widely used for describing diamondoid and graphitic carbon. Recently it has also been used for molecular mechanics and molecular dynamics simulations of fullerenes and nanotubes. However, it has not been tested for the case of functionalized fullerenes (especially with highly strained geometries). We use the Brenner potential for our companion nanogear simulations and believe that it should be calibrated to insure that those simulations are physically reasonable. In the present work, Density Functional theory (DFT) calculations are used to determine the preferred geometric structures and energetics for this calibration. The DFT method is a kind of ab initio quantum chemistry method for determining the electronic structure of molecules. For a given basis set expansion, it is comparable in accuracy to the MP2 method (better than Hartree Fock, but less accurate than more extensive electron correlation methods such as MP4 or CCSD). However, for systems with large numbers of basis functions it more efficient than any other methods that include electron correlation effects. In this presentation we show the results of DFT calculations for the reaction of benzyne with naphthalene, C60, and nanotube models. We compare energies for [2+2] and [2+4] cycloaddition products. The preferred products for the naphthalene and C60 reactions have been determined by experiment and, thus, these cases serve as a validation of our quantum chemical approach. We also compare the DFT and Brenner potential results. Finally we can predict the likelihood of reaction between benzyne and nanotubes.

Jaffe, Richard↗

High-Energy Pulsar Models: Developments and New Questions

The past few years have seen a major advance in observational knowledge of high-energy (HE) pulsars. The Fermi Large Area Telescope (LAT) and AGILE have increased the number of known gamma-ray pulsars by an order of magnitude, its members being divided roughly equally among millisecond pulsars (MSPs), young radio-loud pulsars, and young radio-quiet pulsars. Many new and diverse emission characteristics are being measured, while radio and X-ray follow-up observations increase the pulsar detection rate and enrich our multiwavelength picture of these extreme sources. The wealth of new data has provided impetus for further development and improvement of existing theoretical pulsar models. Geometric light curve (LC) modelling has uncovered three broad classes into which HE pulsars fall: those where the radio profile leads, is aligned with, or lags the gamma-ray profile. For example, the original MSP and original black widow system are members of the second class, requiring co-located emission regions and thereby breaking with traditional notions of radio emission origin. These models imply narrow accelerator gaps in the outer magnetosphere, indicating copious pair production even in MSP magnetospheres that were previously thought to be pair-starved. The increased quality and variety of the LCs necessitate construction of ever more sophisticated models. We will review progress in global magnetosphere solutions which specify a finite conductivity on field lines above the stellar surface, filling the gap between the standard vacuum and force-free (FF; plasma-filled) models. The possibility of deriving phase-resolved spectra for the brightest pulsars, coupled with the fact that the HE pulsar population is sizable enough to allow sampling of various pulsar geometries, will enable much more stringent testing of future radiation models. Reproduction of the observed phase-resolved behavior of this disparate group will be one of the next frontiers in pulsar science, impacting on our understanding of particle acceleration, emission, and magnetosphere geometry. One may now also study evolutionary trends of the measured or inferred quantities, and probe pulsar visibility and population properties such as radiation beam sizes of different pulsar classes, as well as the distribution of spin-down power, gamma-ray luminosity, conversion efficiency, spectral index, and cutoff energy across the population. Lastly, the recent detection of very-high-energy (VHE) pulsations from the Crab pulsar generated quite a few ideas to explain this emission, leading to an extension of standard models and possibly even a bridge between the physics of pulsars and pulsar wind nebulae (PWNe).

gamma rays:↗

Deep Generative Models in Energy System Applications: Review, Challenges, and Future Directions

In recent years, with the advent of mature machine learning products like ChatGPT, Stable Diffusion, and Sora, the world has witnessed tremendous changes driven by the rapid development of generative artificial intelligence (GAI). Beyond applications in text, speech, image, and video creation, deep generative models (DGMs) underpinning these cutting-edge technologies have also been employed by domain researchers to address scientific and engineering challenges. This paper aims to fill a gap in the research community by providing a systematic review of how DGMs have been utilized in energy system applications. After introducing four most popular DGMs, we review and categorize 196 research articles into five focus areas: data generation, forecasting, situational awareness, modeling, and optimal decision-making. Through this classification, we uncover trends in how DGMs are employed for each type of problem, highlighting GAI techniques that contribute to breakthroughs over traditional methods. We discuss limitations in existing literature, engineering challenges, and propose future directions, all tailored to the unique nature of problems in energy system engineering. Our goal is to offer insights for energy system domain researchers, providing a comprehensive view of existing studies and potential future opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AutoBEM for BlocPower

As part of a cooperative research and development agreement (CRADA), the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) and BlocPower partnered to rectify disparities between simulated and actual energy consumption in buildings using various correction methods. This team extended ORNL’s building energy modeling capabilities and used bias-correction techniques to reduce the difference between simulated energy consumption estimations and ground-truth consumption data of buildings provided by utilities. ORNL is one of three core DOE laboratories developing the energy modeling tools EnergyPlus and OpenStudio.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of Remote Sensing and In-situ Observations to Develop and Evaluate Improved Representations of Convection and Clouds for the Accelerated Climate Model for Energy. Final report

Representation of unresolved cloud processes has been one of the most challenging problems in numerical modeling of the atmosphere. During the last decades, considerable efforts have been spent to better represent the collective effects of those processes in terms of resolved scales (see Arakawa 2004 for a review). Still, the progress on this problem has been unacceptably slow as pointed out by Randall et al. (2003). The large part of the difficulty is inherent in the artificial separation of atmospheric processes into the explicitly simulated resolved scales and the highly parameterized subgrid scales. Arakawa (2004) and Arakawa et al. (2011) suggested two plausible approaches to eliminate the problem of artificial separation of atmospheric processes: “parameterize everything” and “resolve everything”.

58 GEOSCIENCES↗

Ensemble Spread Behavior in Coupled Climate Models: Insights From the Energy Exascale Earth System Model Version 1 Large Ensemble

AbstractAssessing uncertainty in future climate projections requires understanding both internal climate variability and external forcing. For this reason, single‐model initial condition large ensembles (SMILEs) run with Earth System Models (ESMs) have recently become popular. Here we present a new 20‐member SMILE with the Energy Exascale Earth System Model version 1 (E3SMv1‐LE), which uses a “macro” initialization strategy choosing coupled atmosphere/ocean states based on inter‐basin contrasts in ocean heat content (OHC). The E3SMv1‐LE simulates tropical climate variability well, albeit with a muted warming trend over the twentieth century due to overly strong aerosol forcing. The E3SMv1‐LE's initial climate spread is comparable to other (larger) SMILEs, suggesting that maximizing inter‐basin ocean heat contrasts may be an efficient method of generating ensemble spread. We also compare different ensemble spread across multiple SMILEs, using surface air temperature and OHC. The Community Earth system Model version 1, the only ensemble which utilizes a “micro” initialization approach perturbing only atmospheric initial conditions, yields lower spread in the first ∼30 years. The E3SMv1‐LE exhibits a relatively large spread, with some evidence for anthropogenic forcing influencing spread in the late twentieth century. However, systematic effects of differing “macro” initialization strategies are difficult to detect, possibly resulting from differing model physics or responses to external forcing. Notably, the method of standardizing results affects ensemble spread: control simulations for most models have either large background trends or multi‐centennial variability in OHC. This spurious disequlibrium behavior is a substantial roadblock to understanding both internal climate variability and its response to forcing.

Stevenson, Samantha↗

Dark energy survey: Modeling strategy for multiprobe cluster cosmology and validation for the full six-year dataset

Here, we introduce an updated To&Krause2021 model for joint analyses of cluster abundances and large-scale two-point correlations of weak lensing and galaxy and cluster clustering (termed CL+3×2 pt analysis) and validate that this model meets the systematic accuracy requirements of analyses with the statistical precision of the final Dark Energy Survey (DES) Year 6 (Y6) dataset. The validation program consists of two distinct approaches, (i) identification of modeling and parametrization choices and impact studies using simulated analyses with each possible model misspecification and (ii) end-to-end validation using mock catalogs from customized Cardinal simulations that incorporate realistic galaxy populations and DES-Y6-specific galaxy and cluster selection and photometric redshift modeling, which are the key observational systematics. In combination, these validation tests indicate that the model presented here meets the accuracy requirements of DES-Y6 for CL+3×2 pt based on a large list of tests for known systematics. In addition, we also validate that the model is sufficient for several other data combinations: the CL+GC subset of this data vector (excluding galaxy–galaxy lensing and cosmic shear two-point statistics) and the CL+3×2 pt+BAO+SN (combination of CL+3×2 pt with the previously published Y6 DES baryonic acoustic oscillation and Y5 supernovae data).

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Energy Survey: Modeling strategy for multiprobe cluster cosmology and validation for the Full Six-year Dataset

We introduce an updated To&Krause2021 model for joint analyses of cluster abundances and large-scale two-point correlations of weak lensing and galaxy and cluster clustering (termed CL+3x2pt analysis) and validate that this model meets the systematic accuracy requirements of analyses with the statistical precision of the final Dark Energy Survey (DES) Year 6 (Y6) dataset. The validation program consists of two distinct approaches, (1) identification of modeling and parameterization choices and impact studies using simulated analyses with each possible model misspecification (2) end-to-end validation using mock catalogs from customized Cardinal simulations that incorporate realistic galaxy populations and DES-Y6-specific galaxy and cluster selection and photometric redshift modeling, which are the key observational systematics. In combination, these validation tests indicate that the model presented here meets the accuracy requirements of DES-Y6 for CL+3x2pt based on a large list of tests for known systematics. In addition, we also validate that the model is sufficient for several other data combinations: the CL+GC subset of this data vector (excluding galaxy--galaxy lensing and cosmic shear two-point statistics) and the CL+3x2pt+BAO+SN (combination of CL+3x2pt with the previously published Y6 DES baryonic acoustic oscillation and Y5 supernovae data).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transformative Efficiency and Automation in Modular Homes (TEAMH)

This report documents the Transformative Efficiency and Automation in Modular Homes (TEAMH) project, which evaluates the integration of advanced building envelope technologies and automation-assisted modular construction to improve residential energy performance and construction efficiency. The study investigates high-performance insulation systems, including vacuum insulation panels (VIPs), combined with light gauge steel (LGS) modular construction and factory automation. Laboratory testing, whole-building energy modeling across multiple climate zones, and factory demonstrations were conducted to assess thermal performance, energy savings, and production efficiency. Results indicate that upgraded envelope assemblies can achieve up to ~50% heating and ~34% cooling energy savings relative to IECC 2018 code-compliant homes, while automation-assisted construction can reduce wall assembly time by 24%–46% compared to conventional wood framing. The findings demonstrate the potential for scalable, high-performance modular homes that deliver significant energy savings with competitive projected costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updated cosmological constraints on axion dark energy with DESI

Here, we present updated constraints on the parameters of an axion dark energy model, for which we took into account the properties of its characteristic potential and its full cosmological evolution. We show that the values of the axion parameters appear sufficiently constrained by the data, including the latest DESI DR1, and are consistent with the theoretical expectations of a field mass 𝑚 𝑎 in the ultralight regime log⁡(𝑚 𝑎 ⁢𝑐 2 /eV) ≃ −32.60 ±0.12, and an effective energy scale 𝑓 𝑎 close to the reduced Planck energy log⁡(𝑓 𝑎 ⁡/𝑀 Pl ) ≃ −0.28 ± 0.19. Our results also support the idea of dynamical dark energy, although Bayesian evidence still favors the phenomenological dark energy model 𝑤 0 ⁢𝑤 𝑎 over the axion dark energy, with the Bayes factor indicating moderate and weak strength of the evidence, respectively, when the models are compared to the cosmological constant Λ. However, the results suggest that axion dark energy remains a well-motivated model and its parameters may be better constrained if the upcoming DESI data show further evidence for dynamical dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

AutoBEM-DynamicArchetypes

Automatic Building Energy Modeling (AutoBEM, https://bit.ly/AutoBEM) has been used to create an OpenStudio and EnergyPlus building energy model of 122.9 million U.S. buildings (https://bit.ly/ModelAmerica). Simulating and analyzing a model of every building for large areas (e.g. cities) is often not feasible. This dynamic archetyping capability uses a representative building and calculates a floor-space multiplier that allows millions of buildings to be represented by less than 100 buildings. This script (WRF_Archetypes_Parallel.py) calculates these building archetypes for each of the grid cells from a Weather Research and Forecasting (WRF) model in a parallel fashion. The script works by looping through each of the grid cells in the shapefile in parallel, spatially joining the building metadata table to each grid cell, aggregating relevant archetypes and calculating necessary statistics related to area and number of buildings in each cell. The output is a table (.csv) in which each row is an archetype building with properties about that building as well as statistics that relate that building to the total cell (such as an area multiplier). The following inputs are required: WRF zone shapefile (.shp) (wrf-grids-origin_Vegas_Select_100.geojson) The projection of the shapefile ("EPSG:XXXX") Input table containing building metadata for area corresponding to shapefile (.csv) (https://zenodo.org/record/4552901#.YZQEotDMJPY - ClarkCounty2.csv) The number of cores that will be parallelized (integer) The output file name for the archetype table (.csv) Sample command line inputs: python3 ~/WRF_Archetypes_Parallel.py -i ~/wrf-grids-origin_Vegas_Select_100.geojson -c ~/ClarkCounty2.csv -o ~/OutputArchetypes.csv -j 72 -e EPSG:4326 Using Geopandas Version 0.9.0

Bass, Brett (0000000240988434)↗

Grey-box modeling and application for building energy simulations - A critical review

Grey-box modeling, as one of the three fundamental modeling techniques for building energy models, has many advantages compared with black-box modeling and white-box modeling. Additionally, it has been widely applied to solve problems of building technologies, such as building load estimation, control and optimization, and building-grid integration. However, a thorough review of grey-box modeling is not available. This review study systematically investigated various aspects of grey-box modeling for buildings. First, the fundamental aspects of grey-box modeling are presented, including the theoretical background, modeling of building elements, modeling order, modeling diagram, and order reduction. Second, the detailed modeling approaches are discussed. Third, multiple applications of grey-box modeling are investigated for building energy domain, which are categorized into the following groups: heat dynamics analysis, thermal load estimation, building control and optimization, district/urban scale energy modeling, and building-grid integration. Finally, the available software packages for grey-box modeling are compared. Overall, the challenges of using grey-box modeling can be summarized as follows: (1) the theoretical limitations and assumptions of grey-box modeling are unclear; (2) grey-box model naming convention and structure are confusing; (3) grey-box model creation is vague; (4) suitable applications of grey-box models are unknown; and (5) grey-box models lack unified software solutions for wider adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scaling Deep Energy Retrofits for Residential Walls - Energy, Cost, and Economic Assessment of Five Wall Systems

Providing strong economic and performance value is a primary challenge of convincing homeowners to implement deep energy retrofits to their wall systems. This study combines energy modeling and technoeconomic assessment of six experimental residential retrofit wall systems to typical existing homes in cold climates to evaluate their energy performance and cost effectiveness. Deep energy retrofits can significantly improve the energy performance of a home’s thermal envelope, help manage indoor environmental pollutants, increase homeowner comfort, increase building value, and register significant energy and cost savings in the process. We are evaluating exterior wall retrofit components and construction practices to measure and recommend steps to improve financial performance for manufacturers, installers and consumers. This study leverages a literature review, inputs from an advisory group made up of thermal enclosure experts, and simulations to identify state-of-the-art technologies for energy efficient wall systems that are suitable for cold and very cold climate zones. This paper will present results from energy modeling of six experimental wall systems compared to one baseline, that inform cost and energy performance of the subject wall systems.

Ganguli, Sumitrra↗

Characterizing patterns and variability of building electric load profiles in time and frequency domains

The rapid development of advanced metering infrastructure provides a new data source—building electrical load profiles with high temporal resolution. Electric load profile characterization can generate useful information to enhance building energy modeling and provide metrics to represent patterns and variability of load profiles. Such characterizations can be used to identify changes to building electricity demand due to operations or faulty equipment and controls. In this study, we proposed a two-path approach to analyze high temporal resolution building electrical load profiles: (1) time-domain analysis and (2) frequency-domain analysis. Furthermore, the commonly adopted time-domain analysis can extract and quantify the distribution of key parameters characterizing load shape such as peak-base load ratio and morning rise time, while a frequency-domain analysis can identify major periodic fluctuations and quantify load variability. We implemented and evaluated both paths using whole-year 15-minute interval smart meter data of 188 commercial office building in Northern California. The results from these two paths are consistent with each other and complementary to represent full dynamics of load profiles. The time- and frequency-domain analyses can be used to enhance building energy modeling by: (1) providing more realistic assumptions about building operation schedules, and (2) validating the simulated electric load profiles using the developed variability metrics against the real building load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Atomistic modeling of energy band alignment in CdTe(1 0 0) and CdTe(1 1 1) surfaces

An atomic-scale perspective of energy band alignment in CdTe surfaces has not been spatially studied despite the major role surfaces play in forming interfaces within CdTe-based thin film photovoltaic devices. Atomistic modeling based on density functional theory coupled with surface Green’s function is used for calculating energy band alignment of CdTe surfaces. The CdTe(1 0 0) ((1×1) and c(2×2) reconstruction) and CdTe(1 1 1) ((1×1) and (2×2) reconstruction) facets without and with surface relaxation provide insightful band bending characteristics that influence charge carrier transport. Results show that unrelaxed (1×1) CdTe(1 0 0) and CdTe(1 1 1) surfaces bend the valence band downward with surface polarity dictating the surface potential magnitude. The reconstructed CdTe(1 0 0) c(2×2) and CdTe(1 1 1) (2×2) surfaces result in favorable surface electronic features in relation to their unreconstructed variants. In addition, the structurally relaxed CdTe(1 1 1) surfaces develop an internal energy cusp potential that may enhance hole charge transport toward the back of CdTe solar cell devices. In conclusion, energy band alignments calculated within the study lead to a detailed understanding of how CdTe surfaces may affect CdTe-based thin film photovoltaic applications.

36 MATERIALS SCIENCE↗

Assessing the Impact of Variable Air Volume Box Damper Stuck Faults Using a Building Automation System and Building Energy Simulation Model

The study examines the impact of variable air volume (VAV) damper stuck faults on the system operation, building indoor conditions, and reheating energy consumption. This study includes both experimental and simulation studies for five test scenarios, including a fault-free scenario. We implemented VAV damper stuck fault through the building automation system (BAS). Results show that a damper stuck in a high opening position (60% damper opening) results in supplying an excessive amount of cold air from the rooftop unit (RTU) to the conditioned zone, increasing reheating energy consumption. The results of this research can serve as a foundational resource for developing fault detection algorithms.

Jung, Sungkyun↗

Catalytically Active Site Mapping Realized through Energy Transfer Modeling

Abstract The demands of a sustainable chemical industry are a driving force for the development of heterogeneous catalytic platforms exhibiting facile catalyst recovery, recycling, and resilience to diverse reaction conditions. Homogeneous‐to‐heterogeneous catalyst transitions can be realized through the integration of efficient homogeneous catalysts within porous matrices. Herein, we offer a versatile approach to understanding how guest distribution and evolution impact the catalytic performance of heterogeneous host–guest catalytic platforms by implementing the resonance energy transfer (RET) concept using fluorescent model systems mimicking the steric constraints of targeted catalysts. Using the RET‐based methodology, we mapped condition‐dependent guest (re)distribution within a porous support on the example of modular matrices such as metal–organic frameworks (MOFs). Furthermore, we correlate RET results performed on the model systems with the catalytic performance of two MOF‐encapsulated catalysts used to promote CO 2 hydrogenation and ring‐closing metathesis. Guests are incorporated using aperture‐opening encapsulation, and catalyst redistribution is not observed under practical reaction conditions, showcasing a pathway to advance catalyst recyclability in the case of host–guest platforms. These studies represent the first generalizable approach for mapping the guest distribution in heterogeneous host–guest catalytic systems, providing a foundation for predicting and tailoring the performance of catalysts integrated into various porous supports.

Thompson, William J.↗