Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “endurance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

MATE program: Erosion resistant compressor airfoil coating, volume 2

The performance of candidate erosion resistant airfoil coatings installed in ground tested experimental JT8D and JT9D engines and subjected to cyclic endurance at idle, takeoff and intermediate power conditions has been evaluated. Engine tests were terminated prior to the scheduled 1000 cycles of endurance test due to high cycle fatigue fracture of the Gator-Gard plasma sprayed 88WC-12Co coating on titanium alloy airfoils. Coated steel (AMS5616) and nickel base alloy (Incoloy 901) performed well in both engine tests. Post test airfoil analyses consisted of binocular, scanning electron microscope and metallographic examinations.

Freling, Melvin↗

Tailless aircraft performance improvements with relaxed static stability

The purpose is to determine the tailless aircraft performance improvements gained from relaxed static stability, to quantify this potential in terms of range-payload improvements, and to identify other possible operational and handling benefits or problems. Two configurations were chosen for the study: a modern high aspect ratio, short-chord wing proposed as a high-altitude long endurance (HALE) remotely piloted vehicle; a wider, lower aspect ratio, high volume wing suitable for internal stowage of all fuel and payload required for a manned long-range reconnaissance mission. Flying at best cruise altitude, both unstable configurations were found to have a 14 percent improvement in range and a 7 to 9 percent improvement in maximum endurance compared to the stable configurations. The unstable manned configuration also shows a 15 percent improvement in the 50 ft takeoff obstacle distance and an improved height response to elevator control. However, it is generally more deficient in control power due to its larger adverse aileron yaw and its higher takeoff and landing lift coefficient C(sub L), both due to the downward trimmed (vs. upward trimmed for stable configurations) trailing edge surfaces.

Ashkenas, Irving L.↗

Surface fatigue life of carburized and hardened M50NiL and AISI 9310 spur gears and rolling-contact test bars

Spur gear endurance tests and rolling-element surface tests were conducted to investigate vacuum-induction-melted, vacuum-arc-melted (VIM-VAR) M50NiL steel for use as a gear steel in advanced aircraft applications, to determine its endurance characteristics, and to compare the results with those for standard VAR and VIM-VAR AISI 9310 gear material. Tests were conducted with spur gears and rolling-contact bars manufactured from VIM-VAR M50NiL and VAR and VIM-VAR AISI 9310. The gear pitch diameter was 8.9 cm (3.5 in.). Gear test conditions were an inlet oil temperature of 320 K (116 F), and outlet oil temperature of 350 K (170 F), a maximum Hertz stress of 1.71 GPa (248 ksi), and a speed of 10,000 rpm. Bench rolling-element fatigue tests were conducted at ambient temperatures with a bar speed of 12,500 rpm and a maximum Hertz stress of 4.83 GPA (700 ksi). The VIM-VAR M50NiL gears had a surface fatigue life that was 4.5 and 11.5 times that for VIM-VAR and VAR AISI 9310 gears, respectively. The surface fatigue life of the VIM-VAR M50NiL rolling-contact bars was 13.2 and 21.6 times that for the VIM-VAR and VAR AISI 9310, respectively. The VIM-VAR M50NiL material was shown to have good resistance to fracture through a fatigue spall and to have fatigue life far superior to that of both VIM-VAR and VAR AISI 9310 gears and rolling-contact bars.

Townsend, Dennis P.↗

Cathode erosion tests for 30 kW arcjets

Endurance tests (100 hours) were conducted to examine the effects of geometry and spacing on 30 kW arcjet cathode erosion. The effects of input power source ripple were also examined. The preliminary results from a 413 hour endurance test are also discussed. This test was terminated voluntarily. The condition of the nozzle, boron nitride propellant injector, and cathode are discussed. A modeling effort is described which is aimed at quantifying the cathode tip heating phenomena. The results of the experiments and the model are compared.

Deininger, W. D.↗

Surface fatigue life of carburized and hardened M50NiL and AISI 9310 spur gears and rolling-contact test bars

Spur gear endurance tests and rolling-element surface tests were conducted to investigate vacuum-induction-melted, vacuum-arc-melted (VIM-VAR) M50NiL steel for use as a gear steel in advanced aircraft applications, to determine its endurance characteristics, and to compare the results with those for standard VAR and VIM-VAR AISI 9310 gear material. Tests were conducted with spur gears and rolling-contact bars manufactured from VIM-VAR M50NiL and VAR and VIM-VAR AISI 9310. The gear pitch diameter was 8.9 cm (3.5 in.). Gear test conditions were an inlet oil temperature of 320 K (116 F), and outlet oil temperature of 350 K (170 F), a maximum Hertz stress of 1.71 GPa (248 ksi), and a speed of 10,000 rpm. Bench rolling-element fatigue tests were conducted at ambient temperatures with a bar speed of 12,500 rpm and a maximum Hertz stress of 4.83 GPA (700 ksi). The VIM-VAR M50NiL gears had a surface fatigue life that was 4.5 and 11.5 times that for VIM-VAR and VAR AISI 9310 gears, respectively. The surface fatigue life of the VIM-VAR M50NiL rolling-contact bars was 13.2 and 21.6 times that for the VIM-VAR and VAR AISI 9310, respectively. The VIM-VAR M50NiL material was shown to have good resistance to fracture through a fatigue spall and to have fatigue life far superior to that of both VIM-VAR and VAR AISI 9310 gears and rolling-contact bars.

Townsend, Dennis P.↗

Surface fatigue life of M50NiL and AISI 9310 spur gears and R C bars

Spur gear endurance tests and rolling element surface fatigue tests were conducted to study vacuum induction melted, vacuum arc remelted (VIM-VAR) M50NiL steel for use as a gear steel in advanced aircraft applications, to determine its endurance characteristics, and to compare the results with those for standard VAR and VIM-VAR AISI 9310 gear material. Tests were conducted with spur gears and rolling contact bars manufactured from VIM-VAR M50NiL and VAR and VIM-VAR AISI 9310. The gear pitch diameter was 8.9 cm. Gear test conditions were an inlet oil temperature of 320 K, and outlet oil temperature of 350 K, a maximum Hertz stress of 1.71 GPa, and a speed of 10000 rpm. Bench rolling element fatigue tests were conducted at ambient temperatures with a bar speed of 12,500 rpm and a maximum Hertz stress of 4.83 GPa. The VIM-VAR M50NiL gears had a surface fatigue life that was 4.5 and 11.5 times that for VIM-VAR and VAR AISI 9310 gears, respectively. The surface fatigue life of the VIM-VAR M50NiL rolling contact bars was 13.2 and 21.6 times that for the VIM-VAR and VAR AISI 9310, respectively. The VIM-VAR M50NiL material was shown to have good resistance to fracture through a fatigue spall and superior fatigue life to both other gears.

Townsend, Dennis P.↗

Exercise performance, core temperature, and metabolism after prolonged restricted activity and retraining in dogs

Physiological effects of restricted activity (RA) and subsequent retraining have been studied. Ten male mongrel dogs performed a submaximal exercise endurance test on a treadmill during kennel control, after 8 weeks of cage confinement and after eight weeks of retraining using the same treadmill protocol 1 h/d for 6 d/week. Data obtained show that RA reduces exercise endurance, the effectiveness of exercise thermoregulation, muscle glycogen stores, and the lipolytic response to exercise and to noradrenaline stimulation.

Nazar, K.↗

Exercise countermeasures for bed-rest deconditioning

The purpose for this 30-day bed rest study was to investigate the effects of short-term, high intensity isotonic and isokinetic exercise training on maintenance of working capacity (peak oxygen uptake), muscular strength and endurance, and on orthostatic tolerance, posture and gait. Other data were collected on muscle atrophy, bone mineralization and density, endocrine analyses concerning vasoactivity and fluid-electrolyte balance, muscle intermediary metabolism, and on performance and mood of the subjects. It was concluded that: The subjects maintained a relatively stable mood, high morale, and high esprit de corps throughout the study. Performance improved in nearly all tests in almost all the subjects. Isotonic training, as opposed to isokinetic exercise training, was associated more with decreasing levels of psychological tension, concentration, and motivation; and improvement in the quality of sleep. Working capacity (peak oxygen uptake) was maintained during bed rest with isotonic exercise training; it was not maintained with isokinetic or no exercise training. In general, there was no significant decrease in strength or endurance of arm or leg muscles during bed rest, in spite of some reduction in muscle size (atrophy) of some leg muscles. There was no effect of isotonic exercise training on orthostasis, since tilt-table tolerance was reduced similarly in all three groups following bed rest. Bed rest resulted in significant decreases of postural stability and self-selected step length, stride length, and walking velocity, which were not influenced by either exercise training regimen. Most pre-bed rest responses were restored by the fourth day of recovery.

Greenleaf, John↗

Exercise detraining: Applicability to microgravity

Physical training exposes the various systems of the body to potent physiologic stimuli. These stimuli induce specific adaptations that enhance an individual's tolerance for the type of exercise encountered in training. The level of adaptation and the magnitude of improvement in exercise tolerance is proportional to the potency of the physical training stimuli. Likewise, our bodies are stimulated by gravity, which promotes adaptations of both the cardiovascular and skeletal muscles. Exposure to microgravity removes normal stimuli to these systems, and the body adapts to these reduced demands. In many respects the cessation of physical training in athletes and the transition from normal gravity to microgravity represent similar paradigms. Inherent to these situations is the concept of the reversibility of the adaptations induced by training or by exposure to normal gravity. The reversibility concept holds that when physical training is stopped (i.e., detraining) or reduced, or a person goes from normal gravity to microgravity, the bodily systems readjust in accordance with the diminished physiologic stimuli. The focus of this chapter is on the time course of loss of the adaptations to endurance training as well as on the possibility that certain adaptations persist, to some extent, when training is stopped. Because endurance exercise training generally improves cardiovascular function and promotes metabolic adaptations within the exercising skeletal musculature, the reversibility of these specific adaptations is considered. These observations have some applicability to the transition from normal to microgravity.

Coyle, Edward F.↗

Diminished Baroreflex Control of Forearm Vascular Resistance Following Training

The stimulus-response characteristics of cardiopulmonary baroreflex control of forearm vascular resistance (FVR units in mm Hg x min x I00 ml/ml) were studied in 14 volunteers before and after 10 wk of endurance training. We assessed the relationship betaleen reflex stimulus (changes in central venous pressure, CVP) and response (FVR) during unloading of cardiopulmonary baroreceptors with lower body negative pressure (LBNP, 0 to - 2O mm Hg). Changes in CVP during LBNP were estimated from pressure changes in a large peripheral vein in the dependent arm of the subject in the right lateral decubitus position. Maximal oxygen uptake (VO(sub 2max)) and total blood volume increased with endurance training from 37.8 +/- 1.4 ml/min x kg and 63.6 +/- 2.1 ml/kg to 45.3 +/- 1.4 ml/ min x kg and 69.3 +/- 2.8 ml/kg respectively (P less than 0.05). Reflex forearm vasoconstriction occurred in response to a reduction in estimated CVP, and the absolute change in FVR per unit of CVP was reduced from -5.96 +/- 0.79 to -4.06 +/- 0.52 units x mm/ Hg (P less than 0.05) following exercise training but was unchanged from -6.10 to 0.57 to -6.22 +/- 0.94 units x mm/ Hg for the time control group (N = 7). Resting values for FVR were similar before and after exercise training; however, resting estimated CVP was elevated from 9.5 +/- 0.5 mm x Hg before training to 11.3 +/- 0.6 mm x Hg after training. The reduction in sensitivity of the cardiopulmonary baroreflex control of FVR was linearly related to the increase in blood volume (r = 0.65, P less than 0.05). suggesting that diminished cardiopulmonary baroreflex control of FVR in physically fit individuals is related, in part, to a training-induced blood volume expansion.

Mack, G. W.↗

Failure Mechanisms During Isothermal Fatigue of SiC/Ti-24Al-11Nb Composites

Failure mechanisms during isothermal fatigue of unidirectional SiC/Ti-24Al-11Nb (at.%) composites have been determined by microstructural analysis of samples from tests interrupted prior to the end of life and from tests conducted to failure. Specimens from three regions of life were examined based on the maximum strain from a fatigue life diagram: Region 1 (high strain), Region 2 (mid-strain) and Region 3 (low strain). Crack lengths were also measured from interrupted samples and compared based on temperature (23-815 C), region of life and numbers of cycles. Region 1 was controlled by fiber-dominated failure. A transition zone was observed between Regions 1 and 2 due to competition between failure mechanisms. Failure in Region 2 was generally described as surface-initiated cracking with varying amounts of fiber bridging. However, the specific descriptions of crack propagation through the fibers and matrix varied with strain and temperature over this broad region. Region 3 exhibited endurance behaviour at 23 C with no cracking after lO(exp 6) cycles. However at 425 C, surface-initiated cracking was observed after 10(exp 6) cycles with fractured fibers in the crack wake. If endurance behaviour exists for conditions of isothermal fatigue in air at temperatures of greater than or equal to 425 C, it may only be found at very low strains and at greater than 10(exp 6) cycles.

Brindley, P. K.↗

JTAGG II Brush Seal Test Results

The Tri-services JTAGG 2 engine uses two identical brush seals, in tandem, located aft of the high pressure compressor. The engine operating conditions, at intermediate rated power (IRP), for this seal are estimated to be 50,000 rpm (899 ft/sec) speed, 175 psid air to air pressure differential and 1200 F air temperature. The testing was comprised of static air leakage, performance, seal offset, rotor run out tests and a 50 hr endurance test in the NASA Lewis seal rig. Based on the test results, it is concluded that the brush seal design should be able to meet the air leakage flow factor goal of less than 0.004 for the engine IRP operating conditions. For the 4.12 in. i.d. labyrinth seal, 0.005 in. typical radial clearance, at the JTAGG 2 operating conditions, the leakage flow factor is 0.007. The long term seal life can not be predicted accurately due to the limited endurance testing of 50 hr. However, based on the excellent condition of the test seal and rotor after 50 hr of testing, it is anticipated that the seals should easily meet the JTAGG 2 engine test requirement.

Arora, Gul K.↗

Evacuated FM08 Fuses Carry a Sustained Arc in a Bus over 75 VDC

The FM08 style fuse is specified to interrupt an overcurrent of up to 300 A in a bus of up to 125 VDC, but this applies only when its barrel is filled with air. When placed into a space-grade vacuum, the FM08 style fuse exhausts its air within a year. Then, the probability of an enduring arc is high for all ratings when the bus is above 75 VDC, and the overcurrent is large. The arc endures until something else interrupts the current. The fuse can violently eject metal vapor or other material during the sustained arcing. The evacuated FM08 does not develop a sustained arc when interrupted in a bus of 38 VDC or less, at least when there is little inductance in the circuit. This is consistent with its successful use in many spacecraft having buses in the range 24 to 36 volts.

Leidecker, Henning↗

Test of Hydrogen-Oxygen PEM Fuel Cell Stack at NASA Glenn Research Center

This paper describes performance characterization tests of a 64 cell hydrogen oxygen PEM fuel cell stack at NASA Glenn Research Center in February 2003. The tests were part of NASA's ongoing effort to develop a regenerative fuel cell for aerospace energy storage applications. The purpose of the tests was to verify capability of this stack to operate within a regenerative fuel cell, and to compare performance with earlier test results recorded by the stack developer. Test results obtained include polarization performance of the stack at 50 and 100 psig system pressure, and a steady state endurance run at 100 psig. A maximum power output of 4.8 kWe was observed during polarization runs, and the stack sustained a steady power output of 4.0 kWe during the endurance run. The performance data obtained from these tests compare reasonably close to the stack developer's results although some additional spread between best to worst performing cell voltages was observed. Throughout the tests, the stack demonstrated the consistent performance and repeatable behavior required for regenerative fuel cell operation.

Bents, David J.↗

Musculoskeletal adaptations to weightlessness and development of effective countermeasures

A Research Roundtable, organized by the American College of Sports Medicine with sponsorship from the National Aeronautics and Space Administration, met in November 1995 to define research strategies for effective exercise countermeasures to weightlessness. Exercise was considered both independently of, and in conjunction with, other therapeutic modalities (e.g., pharmacological nutritional, hormonal, and growth-related factors) that could prevent or minimize the structural and functional deficits involving skeletal muscle and bone in response to chronic exposure to weightlessness, as well as return to Earth baseline function if a degree of loss is inevitable. Musculoskeletal deficits and countermeasures are described with respect to: 1) muscle and connective tissue atrophy and localized bone loss, 2) reductions in motor performance, 3) potential proneness to injury of hard and soft tissues, and 4) probable interaction between muscle atrophy and cardiovascular alterations that contribute to the postural hypotension observed immediately upon return from space flight. In spite of a variety of countermeasure protocols utilized previously involving largely endurance types of exercise, there is presently no activity-specific countermeasure(s) that adequately prevent or reduce musculoskeletal deficiencies. It seems apparent that countermeasure exercises that have a greater resistance element, as compared to endurance activities, may prove beneficial to the musculoskeletal system. Many questions remain for scientific investigation to identify efficacious countermeasure protocols, which will be imperative with the emerging era of long-term space flight.

Non-NASA Center↗

Functional Performance Evaluation

The Extended Duration Orbiter Medical Project (EDOMP) was established to address specific issues associated with optimizing the ability of crews to complete mission tasks deemed essential to entry, landing, and egress for spaceflights lasting up to 16 days. The main objectives of this functional performance evaluation were to investigate the physiological effects of long-duration spaceflight on skeletal muscle strength and endurance, as well as aerobic capacity and orthostatic function. Long-duration exposure to a microgravity environment may produce physiological alterations that affect crew ability to complete critical tasks such as extravehicular activity (EVA), intravehicular activity (IVA), and nominal or emergency egress. Ultimately, this information will be used to develop and verify countermeasures. The answers to three specific functional performance questions were sought: (1) What are the performance decrements resulting from missions of varying durations? (2) What are the physical requirements for successful entry, landing, and emergency egress from the Shuttle? and (3) What combination of preflight fitness training and in-flight countermeasures will minimize in-flight muscle performance decrements? To answer these questions, the Exercise Countermeasures Project looked at physiological changes associated with muscle degradation as well as orthostatic intolerance. A means of ensuring motor coordination was necessary to maintain proficiency in piloting skills, EVA, and IVA tasks. In addition, it was necessary to maintain musculoskeletal strength and function to meet the rigors associated with moderate altitude bailout and with nominal or emergency egress from the landed Orbiter. Eight investigations, referred to as Detailed Supplementary Objectives (DSOs) 475, 476, 477, 606, 608, 617, 618, and 624, were conducted to study muscle degradation and the effects of exercise on exercise capacity and orthostatic function (Table 3-1). This chapter is divided into three parts. Part 1 describes specific findings from studies of muscle strength, endurance, fiber size, and volume. Part 2 describes results from studies of how in-flight exercise affects postflight exercise capacity and orthostatic function. Part 3 focuses on the development of new noninvasive methods for assessing body composition in astronauts and how those methods can be used to correlate measures of exercise performance and changes in body composition.

Greenisen, Michael C.↗

Effect of exercise training on cardiopulmonary baroreflex control of forearm vascular resistance in humans

We studied the stimulus-response characteristics of cardiopulmonary baroreflex control of forearm vascular resistance (FVR) in four groups of male volunteer subjects: i) unfit, ii) physically fit, iii) before and after 10 wk of endurance training (chronic blood volume expansion), and iv) before and after acute blood volume expansion. We assessed the relationship between reflex stimulus, i.e., changes in central venous pressure and response, i.e., FVR, during unloading of cardiopulmonary mechanoreceptors with lower body negative pressure (LBNP, 0 to -20 mm Hg). The slope of the linear relationship between FVR and CVP, the index of the responsiveness of this baroreflex, was significantly diminished (> 50%) in the fit subjects compared with the unfit. The slope of the FVR-CVP relationship was inversely correlated with the subject's total blood volume, suggesting that blood volume expansion was related to the attenuated CP baroreflex. In the exercise training study, maximal oxygen consumption and blood volume increased following 10 wk of endurance training (N = 14) but were unchanged in the time control group (N = 7). The slope of the FVR-CVP relationship was significantly reduced (32%) following 10 wk of training but was unchanged in the time control group. The reduction in slope of the FVR-CVP relationship was inversely related to the increase in blood volume associated with exercise training. Acute blood volume expansion 8 ml.kg-1 body weight with 5% human serum albumin solution) significantly reduced the slope of the FVR-CVP relationship. These data support the hypothesis that the attenuated forearm vascular reflex in physically fit individuals is related to a training-induced hypervolemia.(ABSTRACT TRUNCATED AT 250 WORDS).

Review↗

Blood pressure responses to LBNP in nontrained and trained hypertensive rats

To study the influences of 16 wk of endurance training on the reflex regulation of resting blood pressure, nontrained (NT) and trained (T) female hypertensive rats (SHR) were subjected to conditions of lower body negative pressure (LBNP). Measurements of muscle cytochrome oxidase activity and run time to exhaustion indicated that the animals were endurance trained. The rats (NT = 6, T = 7) were tranquilized with 300-600 micrograms.kg-1 diazepam (IV) before heart rates and blood pressures were measured over a range of 2.5-10.0 mm Hg of negative pressure. When subjected to conditions of LBNP, the reflex tachycardia of the T group was greater than the NT at the lower (-2.5 and -5.0 mm Hg) negative pressures. Although arterial pressure declines were similar in both groups, the T group experienced significantly less of a decline in central venous pressure than the NT animals. When chlorisondamine was used as a ganglionic blocker (2.5 mg.kg-1, IV), the fall in CVP at 10 mm Hg negative pressure was greater for the NT group while the fall in the initial systemic arterial pressure was more for the T group. From these results we concluded that training had altered the interaction between cardiopulmonary and arterial baroreflexes in these hypertensive rats and a nonneural component had been altered such as cardiac function.

Non-NASA Center↗