Fine structure of low-energy H(+) in the nightside auroral region

Low-energy H(+) data with 6-s resolution from the retarding ion mass spectrometer instrument on Dynamics Explorer (DE) 1 have been analyzed to reveal the fine structure at middle altitudes of the nightside auroral region. A new method for deconvolving the energy-integrated count rate in the spin plane of the satellite has been used to derive the two-dimensional phase space density. A detailed analysis reveals an alternating conic-beam-conic pattern with the observed conics correlated with large earthward currents in the auroral region. The strong downward current (larger than 1 microamperes per sq m (equivalent value at ionosphere)) provides a free energy source for the perpendicular ion heating, that generates the ion conics with energies from several eV to tens of eV. The bowl shape distribution of the low-energy H(+) is caused by the extended perpendicular heating. The strong correlation between conics and large downward currents suggests that the current-driven electrostatic ion cyclotron wave is an appropriate candidate for the transverse heating mechanism.

Liu, Chao↗

Carbon Nanotubes in Water: MD Simulations of Internal and External Flow, Self Organization

We have developed computational tools, based on particle codes, for molecular dynamics (MD) simulation of carbon nanotubes (CNT) in aqueous environments. The interaction of CNTs with water is envisioned as a prototype for the design of engineering nano-devices, such as artificial sterocillia and molecular biosensors. Large scale simulations involving thousands of water molecules are possible due to our efficient parallel MD code that takes long range electrostatic interactions into account. Since CNTs can be considered as rolled up sheets of graphite, we expect the CNT-water interaction to be similar to the interaction of graphite with water. However, there are fundamental differences between considering graphite and CNTs, since the curvature of CNTs affects their chemical activity and also since capillary effects play an important role for both dynamic and static behaviour of materials inside CNTs. In recent studies Gordillo and Marti described the hydrogen bond structure as well as time dependent properties of water confined in CNTs. We are presenting results from the development of force fields describing the interaction of CNTs and water based on ab-initio quantum mechanical calculations. Furthermore, our results include both water flows external to CNTs and the behaviour of water nanodroplets inside heated CNTs. In the first case (external flows) the hydrophobic behaviour of CNTs is quantified and we analyze structural properties of water in the vicinity of CNTs with diagnostics such as hydrogen bond distribution, water dipole orientation and radial distribution functions. The presence of water leads to attractive forces between CNTs as a result of their hydrophobicity. Through extensive simulations we quantify these attractive forces in terms of the number and separation of the CNT. Results of our simulations involving arrays of CNTs indicate that these exhibit a hydrophobic behaviour that leads to self-organising structures capable of trapping water clusters. In the second case (internal flows) we study the behaviour of water droplets confined inside CNTs. Constant temperature simulations allow us to capture structural properties such as the contact angles and density profiles of the equilibrated drops. By heating and subsequently cooling of the CNT, we are able to measure the evaporation and the condensation rate of the entrapped water.

Jaffe, Richard L.↗

Genesis Solar-Wind Sample Return Mission: The Materials

The Genesis spacecraft has two primary instruments which passively collect solar wind. The first is the collector arrays , a set of panels, each of which can deploy separately to sample the different kinds of solar wind (regimes). The second is the concentrator, an electrostatic mirror which will concentrate ions of mass 4 through mass 25 by about a factor of 20 by focusing them onto a 6 cm diameter target. When not deployed, these instruments fit into a compact canister. After a two year exposure time, the deployed instruments can be folded up, sealed into the canister, and returned to earth for laboratory analysis. Both the collector arrays and the concentrator will contain suites of ultra-high purity target materials, each of which is tailored to enable the analysis of a different family of elements. This abstract is meant to give a brief overview of the Genesis mission, insight into what materials were chosen for flight and why, as well as head s up information as to what will be available to planetary scientist for analysis when the solar-wind samples return to Earth in 2003. Earth. The elemental and isotopic abundances of the solar wind will be analyzed in state-of-the-art laboratories, and a portion of the sample will be archived for the use of future generations of planetary scientists. Technical information about the mission can be found at www.gps.caltech.edu/genesis.

Jurewicz, A. J. G.↗

Space Induced Discharge Model to Be Used on Interface Circuit Vulnerability Assessment

Charging can occur in space due to plasma and high energy particles. Charging is especially severe in certain earth orbits such as geostationary orbit, medium earth orbit and highly inclined orbit. A spacecraft that travels to other planets such as Jupiter also encounters high level of charging due to Jupiter’s radiation belt. The major concern for spacecraft operation due to charging is the survival of sensitive electrical circuits. Dielectrics and floating metal can charge up and discharge onto interface circuits. The electrical circuits need to be evaluated for survival from the electrostatic-discharge (ESD) threat. Both ESD induced upset and damage need to be assessed. The interface circuits are often located inside a shielded unit in the spacecraft structure or a shielded vault with sufficient radiation shielding to avoid surface and internal charging. The materials external to the highly shielded area can charge up and discharge onto wires that can directly dissipate the ESD onto the interface circuits. Figure 1 shows a possible discharge mechanism onto the interfacing circuits. If the wire has an external shield or a coaxial line, some or most of the discharge can flow on the shield to chassis ground. There is always coupling from external discharge. If the wire has no shield, the discharge flows onto the interface circuit. Fig. 1 Possible discharge paths onto the interface circuits. The purpose of this article is to address how to model the ESD threat to be used as the discharge source onto the interface circuit based on the electron beam test data. Different models are needed for different impedances associated with the interface circuits. Once those models are derived, one needs to analyze the interface circuit with the corresponding model using an electrical simulation tool. Then, the circuit’s front-end components can be assessed for damage and upset. Upset is highly dependent on the circuit operation and system requirements, and thus it is not addressed any further. Damage of electrical parts is often rated under Human-Body-Model (HBM) ESD. One can utilize this industry-wide available information to assess the damage vulnerability due to space discharges. However, the HBM waveform does not always match the discharge waveform. To estimate the damage vulnerability of the circuit and set margin, one needs to compare the equivalent energy delivered to the victim between a HBM discharge and the results from an ESD source model based on actual discharges. This paper presents such a comparison for a few select cases.

Xie, Julie↗

Electric Propulsion Induced Secondary Mass Spectroscopy

A document highlights a means to complement remote spectroscopy while also providing in situ surface samples without a landed system. Historically, most compositional analysis of small body surfaces has been done remotely by analyzing reflection or nuclear spectra. However, neither provides direct measurement that can unambiguously constrain the global surface composition and most importantly, the nature of trace composition and second-phase impurities. Recently, missions such as Deep Space 1 and Dawn have utilized electric propulsion (EP) accelerated, high-energy collimated beam of Xe+ ions to propel deep space missions to their target bodies. The energies of the Xe+ are sufficient to cause sputtering interactions, which eject material from the top microns of a targeted surface. Using a mass spectrometer, the sputtered material can be determined. The sputtering properties of EP exhaust can be used to determine detailed surface composition of atmosphereless bodies by electric propulsion induced secondary mass spectroscopy (EPI-SMS). EPI-SMS operation has three high-level requirements: EP system, mass spectrometer, and altitude of about 10 km. Approximately 1 keV Xe+ has been studied and proven to generate high sputtering yields in metallic substrates. Using these yields, first-order calculations predict that EPI-SMS will yield high signal-to-noise at altitudes greater than 10 km with both electrostatic and Hall thrusters.

Amini, Rashied↗

Effects of Oxygen Partial Pressure on the Surface Tension of Liquid Nickel

The NASA Marshall Space Flight Center's electrostatic levitation (ESL) laboratory has been recently upgraded with an oxygen partial pressure controller. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, theoretically in the range from 10‐36 to 100 bar. The oxygen control system installed in the ESL laboratory's main chamber consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity in two gas compartments (inside the chamber and the air outside of the chamber) separated by an electrolyte, which is yttria‐stabilized zirconia. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. The controller performs temperature control for the sensor and pump, PID-based current loop, and a control algorithm. Oxygen partial pressure has been shown to play a significant role in the surface tension of liquid metals. Oxide films or dissolved oxygen may lead to significant changes in surface tension. The effects of oxygen partial pressure on the surface tension of undercooled liquid nickel will be analyzed, and the results will be presented. The surface tension will be measured at several different oxygen partial pressures while the sample is undercooled. Surface tension will be measured using the oscillating drop method. While undercooled, each sample will be oscillated several times consecutively to investigate how the surface tension behaves with time while at a particular oxygen partial pressure.

SanSoucie, Michael P.↗

Freja Studies of the Current-Voltage Relation in Substorm-Related Events

Field-aligned currents and electrostatic potentials play important roles in the coupling between the magnetosphere and the ionosphere. If one assumes that the ionosphere-magnetosphere potential difference is mainly due to the mirror force, one can use the single particle adiabatic kinetic theory to describe the system. From this theory, a linear relationship j(sub II) = KV between field-aligned current density j(sub II) and potential drop V along the same field line can be derived, provided that the potential drop is not too large and not too small. With rare exceptions, observational tests of this relation have mainly concentrated on quiet magnetospheric situations, with acceleration voltages V approx. less than 5 kV. Here we use observations from the Freja satellite of precipitating auroral electrons at 1.700 km altitude to study substorm related events, with acceleration voltages up to 20 keV. The observations are found to be consistent with a linear current-voltage relation even i n these conditions, although with values of the field aligned K lower than previously reported (1-5 x 10(exp 11 S/sq m). This can be explained by lower densities and higher characteristic electron energies in the magnetospheric source region of the precipitating electrons. We analyze the data by three different methods, which are all found to be in general agreement. The results are in agreement with a previous study, where the spectra of precipitating electrons --were indirectly inferred by inversion of data from the EISCAT incoherent scatter radar, thereby validating the use of radar data for studies of auroral electrons. Comparisons with previous studies are made, emphasizing the dependence of the results on the type of auroral structure and magnetospheric conditions.

Olsson, A.↗

Mathematical Inversion of Lightning Data: Techniques and Applications

A survey of some interesting mathematical inversion studies dealing with radio, optical, and electrostatic measurements of lightning are presented. A discussion of why NASA is interested in lightning, what specific physical properties of lightning are retrieved, and what mathematical techniques are used to perform the retrievals are discussed. In particular, a relatively new multi-station VHF time-of-arrival (TOA) antenna network is now on-line in Northern Alabama and will be discussed. The network, called the Lightning Mapping Array (LMA), employs GPS timing and detects VHF radiation from discrete segments (effectively point emitters) that comprise the channel of lightning strokes within cloud and ground flashes. The LMA supports on-going ground-validation activities of the low Earth orbiting Lightning Imaging Sensor (LIS) satellite developed at NASA Marshall Space Flight Center (MSFC) in Huntsville, Alabama. The LMA also provides detailed studies of the distribution and evolution of thunderstorms and lightning in the Tennessee Valley, and offers interesting comparisons with other meteorological/geophysical datasets. In order to take full advantage of these benefits, it is essential that the LMA channel mapping accuracy (in both space and time) be fully characterized and optimized. A new channel mapping retrieval algorithm is introduced for this purpose. To characterize the spatial distribution of retrieval errors, the algorithm has been applied to analyze literally tens of millions of computer-simulated lightning VHF point sources that have been placed at various ranges, azimuths, and altitudes relative to the LMA network. Statistical results are conveniently summarized in high-resolution, color-coded, error maps.

Koshak, William↗

Measurements and Theoretical Calculations of N2-broadening and N2-shift Coefficients in the v2 band of CH3D

In this paper, we report measured Lorentz N2-broadening and N2-induced pressure-shift coefficients of CH3D in the v2 fundamental band using a multispectrum fitting technique. These measurements were made by analyzing 11 laboratory absorption spectra recorded at 0.0056 cm(exp -1) resolution using the McMath-Pierce Fourier transform spectrometer located at the National Solar Observatory on Kitt Peak, Arizona. The spectra were obtained using two absorption cells with path lengths of 10.2 and 25 cm. The total sample pressures ranged from 0.98 to 402.25 Torr with CH3D volume mixing ratios of 0.01 in nitrogen. We have been able to determine the N2 pressure- broadening coefficients of 368 v2 transitions with quantum numbers as high as J"= 20 and K = 16, where K" = K' equivalent to K (for a parallel band). The measured N2-broadening coefficients range from 0.0248 to 0.0742 cm(exp -1) atm(exp -1) at 296 K. All the measured pressure-shifts are negative. The reported N2-induced pressure-shift coefficients vary from about 0.0003 to 0.0094 cm(exp -1) atm(exp -1). We have examined the dependence of the measured broadening and shift parameters on the J", and K quantum numbers and also developed empirical expressions to describe the broadening coefficients in terms of m (m = -J", J", and J" + 1 in the (sup Q)P-, (sup Q)Q-, and (sup Q)R-branch, respectively) and K. On average, the empirical expressions reproduce the measured broadening coefficients to within 4.7%. The N2-broadening and pressureshift coefficients were calculated on the basis of a semiclassical model of interacting linear molecules performed by considering in addition to the electrostatic contributions the atom atom Lennard-Jones potential. The theoretical results of the broadening coefficients are in good overall agreement with the experimental data (8.7%). The N2-pressure shifts whose vibrational contribution is derived from parameters fitted in the (sup Q)Q-branch of self-induced shifts of CH3D, are also in reasonable agreement with the scattered experimental data (20% in most cases).

Predoi-Cross, A.↗

Room-temperature Broadening and Pressure-shift Coefficients in the nu(exp 2) Band of CH3D-O2: Measurements and Semi-classical Calculations

We report measured Lorentz O2-broadening and O2-induced pressure-shift coefficients of CH3D in the nu(exp 2) fundamental band. Using a multispectrum fitting technique we have analyzed 11 laboratory absorption spectra recorded at 0.011 cm(exp 1) resolution using the McMath-Pierce Fourier transform spectrometer, Kitt Peak, Arizona. Two absorption cells with path lengths of 10.2 and 25 cm were used to record the spectra. The total sample pressures ranged from 0.98 to 339.85 Torr with CH3D volume mixing ratios of 0.012 in oxygen. We report measurements for O2 pressure-broadening coefficients of 320 nu(exp 2) transitions with quantum numbers as high as J0(sup w) = 17 and K = 14, where K(sup w) = K' is equivalent to K (for a parallel band). The measured O2-broadening coefficients range from 0.0153 to 0.0645 cm(exp -1) atm(exp -1) at 296 K. All the measured pressure-shifts are negative. The reported O2-induced pressure-shift coefficients vary from about -0.0017 to -0.0068 cm(exp -1) atm(exp -1). We have examined the dependence of the measured broadening and shift parameters on the J(sup W), and K quantum numbers and also developed empirical expressions to describe the broadening coefficients in terms of m (m = -J(sup W), J(sup W), and J(sup w) + 1 in the QP-, QQ-, and QR-branch, respectively) and K. On average, the empirical expressions reproduce the measured broadening coefficients to within 4.4%. The O2-broadening and pressure shift coefficients were calculated on the basis of a semiclassical model of interacting linear molecules performed by considering in addition to the electrostatic contributions the atom-atom Lennard-Jones potential. The theoretical results of the broadening coefficients are generally larger than the experimental data. Using for the trajectory model an isotropic Lennard-Jones potential derived from molecular parameters instead of the spherical average of the atom-atom model, a better agreement is obtained with these data, especially for |m| <= 12 values (11.3% for the first calculation and 8.1% for the second calculation). The O2-pressure shifts whose vibrational contribution are either derived from parameters fitted in the QQ-branch of selfinduced shifts of CH3D or those obtained from pressure shifts induced by Xe in the nu(sup 3) band of CH3D are in reasonable agreement with the scattered experimental data (17.0% for the first calculation and 18.7% for the second calculation).

Predoi-Cross, Adriana↗

Miniature Focusing Time-of-Flight Mass Spectrometer

An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged-particle detector. The output of the detector is fed to a counting circuit to obtain data on the counting rate as a function of time. Inasmuch as time of flight is directly proportional to the ion mass, a plot of the counting rate versus time of flight is equivalent to a mass spectrum (see Figure 2).

Kanik, Isik↗

The Use of Tribocharging in the Electrostatic Beneficiation of Lunar Simulant

Any future lunar base and habitat must be constructed from strong dense materials in order to provide for thermal and radiation protection. Lunar soil may meet this need. Lunar regolith has high concentrations of aluminum, silicon, calcium, iron, sodium, and titanium oxides. Refinement or enrichment of specific minerals in the soil before it is chemically processed may be more desirable as it would reduce the size and energy requirements required to produce the virgin material and it may significantly reduce the process' complexity. Also, investigations into the potential production of breathable oxygen from oxidized mineral components are a major research initiative by NASA. In this study. the objective was to investigate the use of tribocharging to charge lunar simulants and pass them through a parallel plate separator to enrich different mineral fractions. This technique takes advantage of the high Lunar vacuum in which much higher voltages can be used on the separation plates than in air. Additionally, the Lunar g1avity, only being 1/6 that of Earth, allows the particles more separation time between the plates and therefore enhances separation. For the separation studies, two lunar stimulants were used. The first simulant was created in-house, labeled KSC-1. using commercially supplied (sieved to 325 mesh) materials, and was composed of 40 wt. % feldspar ((Na,K,Ca)AlSi3O8;SiO2), 40 wt. % olivine ((Mg,Fe)2SiO4), 10 wt. % ilmenite (FeTiO3). and 10 wt. % spodumene (LiAlSi2O6) (pyroxene). The advantage of the in-house mixture is that the composition can he varied to simulate different soil compositions from different areas on the moon. This simulant was used to show proof-of-concept using the designed separator in air. The second stimulant was JSC-1. used for the vacuum experiments. JSC-1 is principally basalts, containing phases of plagioclase. pyroxene. olivine, and ilmenite. The JSC-1 was sieved to provide a 50-75 micron size range to correlate with the mean grain size found on the moon's surface [1]. Four different materials were investigated for the triboelectrification process; aluminum, copper. stainless steel, and PTFE. These materials were selected because they offer a wide variation in work functions (aluminum 4.28 eV, copper 4.65 eV. stainless steel 5.04 eV, and PTFE 5.75 eV). The difference between the work function of each material and the simulant influences the charge obtained by the grains. Each simulant was analyzed before and after separation using X-ray Photoelectron Spectroscopy (XPS) to determine mineral surface composition. In addition. Raman spectroscopy was performed on the JSC-1 before and after separation in vacuum to determine the mineral composition. Charge-to-mass (Q/M) measurements were performed using a fluidizing bed in air and passing the simulant through a static mixer of a particular material and collecting it in a Faraday pail grounded through an electrometer. To measure the Q/M in vacuum, a special device was constructed consisting of a heater/shaker cup that fed into a solid block of material (either PTFE, copper, or aluminum) in which a channel composed of a "zig-zag" series of inclines greater than 50 degrees has been cut. The voltage to the vibrating motor can be varied to control the amount of simulant passing through the channel. Figure I shows the Q/M measurements for JSC-1 tribocharged using the static mixers and the incline plane chargers in air, and the incline plane chargers in vacuum.

Trigwell, S.↗

Modeling of Orbital and Attitude Dynamics of Nanosatellites Controlled via Active Electrostatic Charging

The large-scale exploration of airless bodies, such as asteroids and moons, is gaining interest, however it is limited by mobility issues: the lack of atmosphere, low gravity, and unknown soil properties pose difficult challenges for many forms of traditional locomotion. The environment in proximity of these bodies is also electrically charged due to interactions with solar wind and UV radiation. The EGlider (Electrostatic Glider) concept would be able to overcome these mobility issues by leveraging the natural environment, allowing operations in close proximity of the surface, while enabling long duration missions by minimizing propellant consumption. The EGlider is an advanced concept for small satellite mobility and propulsion, which relies on the electric fields naturally present around airless bodies in order to generate forces and torques useful for maneuvering. It does so by extending electrically charged appendages, which enable it to electrostatically soar above the surface. By differentially charging its electrodes it can also produce torques to control its attitude. The charges are maintained by continuous active ion or electron emission from the spacecraft, in order to cancel out the neutralizing influx of charges from surrounding plasma. An investigation of the spacecraft-plasma interaction was carried out. This included studying the effect of electrode geometry and calculating the charge-to-mass ratios required to enable several mission scenarios. Long, thin wire electrodes were identified to be the most power-efficient and would allow power-to-weight ratios achievable with current nanosatellite technologies. High electrode potential represents the main limiting factor for the system design. In order to test the feasibility of active control by means of differential charging, a simple 2D interaction model was developed, and a feedback controller to stabilize the vehicle was tested in a simulation environment. The results confirmed that good performance could be obtained for both position and attitude control. Finally, a dedicated software was developed for future simulation and testing of control strategies for the EGlider. This software allows to study the trajectory and attitude of an arbitrarily configured spacecraft in the proximity of an arbitrarily defined main airless body. The spacecraft can be assembled from basic parts, each with specified electrical, mass and optical properties. Efficient models allow to calculate gravitational and electrical interactions with the rotating main body and the local plasma field, as well as solar radiation pressure effects. Control models can be implemented as simple plug-in functions and easily tested. The preliminary validation campaign showed good matching with the reference cases that have been analyzed.

Corpino, Sabrina↗

History and Flight Devleopment of the Electrodynamic Dust Shield

The surfaces of the moon, Mars, and that of some asteroids are covered with a layer of dust that may hinder robotic and human exploration missions. During the Apollo missions, for example, lunar dust caused a number of issues including vision obscuration, false instrument readings, contamination, and elevated temperatures. In fact, some equipment neared failure after only 75 hours on the lunar surface due to effects of lunar dust. NASA's Kennedy Space Center has developed an active technology to remove dust from surfaces during exploration missions. The Electrodynamic Dust Shield (EDS), which consists of a series of embedded electrodes in a high dielectric strength substrate, uses a low power, low frequency signal that produces an electric field wave that travels across the surface. This non-uniform electric field generates dielectrophoretic and electrostatic forces capable of moving dust out of these surfaces. Implementations of the EDS have been developed for solar radiators, optical systems, camera lenses, visors, windows, thermal radiators, and fabrics The EDS implementation for transparent applications (solar panels, optical systems, windows, etc.) uses transparent indium tin oxide electrodes on glass or transparent lm. Extensive testing was performed in a roughly simulated lunar environment (one-sixth gravity at 1 mPa atmospheric pressure) with lunar simulant dust. EDS panels over solar radiators showed dust removal that restored solar panel output reaching values very close to their initial output. EDS implementations for thermal radiator protection (metallic spacecraft surfaces with white thermal paint and reflective films) were also extensively tested at similar high vacuum conditions. Reflectance spectra for these types of implementations showed dust removal efficiencies in the 96% to 99% range. These tests indicate that the EDS technology is now at a Technology Readiness Level of 4 to 5. As part of EDS development, a flight version is being prepared for several flight opportunities. The flight version of the EDS will incorporate significantly smaller electronics, with an expected mass and volume of 500 g and 350 cm(exp. 3) respectively. One of the opportunities is an International Space Station (ISS) experiment: Materials for International Space Station Experiment 10 (MISSE-10). This experiment aims to verify the EDS can withstand the harsh environment of space and will look to closely replicate the solar environment experienced on the moon. A second flight opportunity exists to provide an EDS to several companies as part of NASA's Lunar CATALYST program. The current mission concept would fly the EDS on the footpad of one of the Lunar CATALYST vehicles. Dust will likely deposit on the footpad through normal surface rover activities, but also upon landing where lunar dust is expected to be uplifted. To analyze the e effectiveness of the EDS system, photographs of the footpad with one of the spacecrafts onboard cameras are anticipated. If successful in these test flights, the EDS technology will be ready to be used in the protection of actual mission equipment for future NASA and commercial missions to the moon, asteroids, and Mars.

Lunar↗

Low-Pressure, Field-Ionizing Mass Spectrometer

A small mass spectrometer utilizing a miniature field ionization source is now undergoing development. It is designed for use in a variety of applications in which there are requirements for a lightweight, low-power-consumption instrument that can analyze the masses of a wide variety of molecules and ions. The device can operate without need for a high-vacuum, carrier-gas feed radioactive ionizing source, or thermal ionizer. This mass spectrometer can operate either in the natural vacuum of outer space or on Earth at any ambient pressure below 50 torr (below about 6.7 kPa) - a partial vacuum that can easily be reached by use of a small sampling pump. This mass spectrometer also has a large dynamic range - from singly charged small gas ions to deoxyribonucleic acid (DNA) fragments larger than 104 atomic mass units - with sensitivity adequate for detecting some molecules and ions at relative abundances of less than one part per billion. This instrument (see figure) includes a field ionizer integrated with a rotating-field mass spectrometer (RFMS). The field ionizer effects ionization of a type characterized as "soft" in the art because it does not fragment molecules or initiate avalanche arcing. What makes the "soft" ionization mode possible is that the distance between the ionizing electrodes is less than mean free path for ions at the maximum anticipated operating pressure, so that the ionizer always operates on the non-breakdown side of the applicable Paschen curve (a standard plot of breakdown potential on the ordinate and pressure electrode separation on the abscissa). The field ionizer in this instrument is fabricated by micromachining a submicron-thick membrane out of an electrically nonconductive substrate, coating the membrane on both sides to form electrodes, then micromachining small holes through the electrodes and membrane. Because of the submicron electrode separation, even a potential of only 1 V applied between the electrodes gives rise to an electric field with a strength of in excess of a megavolt per meter strong enough to ionize any gas molecules passing through the holes. An accelerator grid and an electrostatic deflector focus the ions from the field ionizer into the rotating-field cell of the RFMS. The potentials applied to the electrodes of the cell to generate the rotating electric field typically range from 1 to 13 V. The ions travel in well-defined helices within this cell, after which they are collected in a Faraday cup. The mass of most of the molecules reaching the Faraday cup decreases with increasing frequency of rotation of the electric field in the cell. Therefore, the frequency of rotation of the electric field is made to vary in order to scan through a desired range of ion masses: For example, lightweight gas molecules are scanned at frequencies in the megahertz range, while DNA and other large organic molecules are scanned at kilohertz frequencies.

Hartley, Frank↗

Behavior of Triple Langmuir Probes in Non-Equilibrium Plasmas

The triple Langmuir probe is an electrostatic probe in which three probe tips collect current when inserted into a plasma. The triple probe differs from a simple single Langmuir probe in the nature of the voltage applied to the probe tips. In the single probe, a swept voltage is applied to the probe tip to acquire a waveform showing the collected current as a function of applied voltage (I-V curve). In a triple probe three probe tips are electrically coupled to each other with constant voltages applied between each of the tips. The voltages are selected such that they would represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Under the assumption of a Maxwellian plasma, one can determine the time-varying plasma temperature T(sub e)(t) and number density n(sub e)(t) from the applied voltage levels and the time-histories of the collected currents. In the present paper we examine the theory of triple probe operation, specifically focusing on the assumption of a Maxwellian plasma. Triple probe measurements have been widely employed for a number of pulsed and timevarying plasmas, including pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. While the equilibrium assumption may be justified for some applications, it is unlikely that it is fully justifiable for all pulsed and time-varying plasmas or for all times during the pulse of a plasma device. To examine a simple non-equilibrium plasma case, we return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. We compare the distribution function that was assumed a priori with the distribution function one would infer when applying standard triple probe theory to analyze the collected currents. For the assumed class of non-Maxwellian distribution functions this serves to illustrate the effect a non-Maxwellian plasma would have on results interpreted using the equilibrium triple probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.

Polzin, Kurt A.↗

Behavior of Langmuir Probes in Non-Equilibrium Plasmas

Langmuir probes are diagnostic tools used to determine electron temperature, number density, and plasma potential. Irving Langmuir first used an electrostatic probe in the 1920s to find these characteristics in ionized gases. Single, double, and triple Langmuir probes are commonly used in plasma diagnostics because of their relative simplicity. In the single probe, a swept voltage is applied between the probe tip and circuit common to acquire a waveform showing the collected current as a function of applied voltage. A double Langmuir probe consists of two tips, both inserted into the plasma, with a voltage applied between them. As this voltage is swept, a current-voltage characteristic is measured. In a triple probe three probe tips are electrically coupled to each other with constant non-swept voltages applied between each of the tips. The voltages are selected to represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Triple Langmuir probe measurements have been widely employed for various types of plasmas, including pulsed and time-varying plasmas such as those seen in pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. The typical Langmuir probe analysis for determining electron temperature and number density of the plasma (for a single, double, or triple Langmuir probe) includes an assumption that the plasma is in thermal equilibrium. While the this assumption may be justified for some applications, it is unlikely that it is fully justifiable for pulsed and time-varying plasmas or for the entire time a plasma device is in use. In the present work, we model the responses of Langmuir probes as they are inserted into a range of simple equilibrium and non-equilibrium plasmas. We return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. Comparing the distribution function that was assumed a priori with the plasma density and temperature one would infer when applying standard probe theory to analyze the collected currents serves to illustrate the effect a non- Maxwellian plasma would have on results interpreted using the equilibrium probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.

Polzin, Kurt A.↗

Electric Sail Design Sensitivities

Electric Sails (E-Sails) are a promising propulsion technology that seek to enable high characteristic propellentless acceleration for spacecraft to reach distant and/or difficult to reach orbits such as rapid transit to heliopause. The E-Sail system exchanges momentum by using positively charged electrostatic tethers to repel solar wind photons to push it through space. This concept was first theorized by Pekka Janhunen in 2004 with further developments occurring including a NASA Innovative Advanced Concepts Phase 1 and Phase 2 hosted out of NASA’s Marshall Space Flight Center (MSFC). These developments led to further maturation of the overall system, and this paper is designed to help identify different design sensitivities of an integrated Electric Sail system. To approach this, a small team at MSFC took an in-house developed three degrees of freedom (3DoF) simulation tool and a trajectory modelling tool to look at different design parameters and to determine a potential ideal E-Sail configuration. An E-Sail system has different design architectures including a barbell design, hub and spoke design, and a potential hybrid solution. The barbell design features two equally massed satellites that spin around a central point in the tether system. The hub and spoke design features a large central spacecraft with small end spacecraft to aid in formation control of the overall E-Sail system. Leveraging elements from both the hub and spoke, and barbell design, a hybrid option exists where one could have a larger central mass and one or two tethers extended to a smaller end mass [2]. In summary, the hub and spoke design is the ideal configuration for E-Sail with tethers spanning kilometers to achieve the designed design characteristic acceleration of at least one mm/s2 with this architecture being the focus of this study. Different key design parameters were varied as part of this study. These parameters include the total number of tethers, the length of the tethers, spin rate, relative spacecraft mass, tether voltage, inertia per tether, and impact of slew rate changes. These results started from an internal MSFC technology demonstration mission design and then the parameters were varied with engineering judgement to ensure that the results were consistent with expected results. These were varied in the MSFC 3DoF tool and compared to baseline results to generate a candidate ideal E-Sail design system. These results were then used to help inform the mission analysis design for the system. The 3DoF trajectory optimization was performed in the Astrodynamics and Space Science Enabling Toolbox (ASSET) and utilized collocation optimization of control vector pointing with the objective function being transfer duration. A representative model of the E-Sail force was derived as a function of the Sun-pointing vector direction. This model was initialized with a zero Sun Incidence Angle (SIA) trajectory for the initial guess generation, then with a portion of the mission optimized SIA time history for fast outbound transfers. After the trajectory is hyperbolic relative to a heliocentric frame, the SIA is maintained at 0 degrees except for any needed trajectory correction maneuvers. This trajectory optimization looked at different characteristic acceleration values to analyze the impact it had on mission performance. As a result of this study, the team can best inform mission designers and technology development efforts to mature the E-Sail system. This study will allow mission designers to have defined rules-of-thumb to design an E-Sail system to meet desired mission needs as well as providing several sample mission profiles. These design drivers will inform maturation efforts on which design requirements to consider for an integrated E-Sail design.

E-Sail↗