Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Sources of noise in magneto-optical readout

The various sources of noise which are often encountered in magneto-optical readout systems are analyzed. Although the focus is on magneto-optics, most sources of noise are common among the various optical recording systems and one can easily adapt the results to other media and systems. A description of the magneto-optical readout system under consideration is given, and the standard methods and the relevant terminology of signal and noise measurement are described. The characteristics of thermal noise, which originates in the electronic circuitry of the readout system, are described. The most fundamental of all sources of noise, the shot noise, is considered, and a detailed account of its statistical properties is given. Shot noise, which is due to random fluctuations in photon arrival times, is an ever-present noise in optical detection. Since the performance of magneto-optical recording devices in use today is approaching the limit imposed by the shot noise, it is important that the reader have a good grasp of this particular source of noise. A model for the laser noise is described, and measurement results which yield numerical values for the strength of the laser power fluctuations are presented. Spatial variations of the disk reflectivity and random depolarization phenomena also contribute to the overall level of noise in readout; these and related issues are treated. Numerical simulation results describing some of the more frequently encountered sources of noise which accompany the recorded waveform itself, namely, jitter noise and signal-amplitude fluctuation noise are presented.

Mansuripur, M.↗

Relativistic electrons associated with solar flares.

Solar flares which produce relativistic electrons generally occur within sunspot groups which are active in the emission of meter type I noise storms. It is suggested that relativistic electrons in solar flares are accelerated from the keV-energy electrons responsible for the type I noise storms. The relationship between flare developments and the ejection of keV-electrons is briefly considered.

Sakurai, K.↗

Deep learning-based noise filtering toward millisecond order imaging by using scanning transmission electron microscopy

Application of scanning transmission electron microscopy (STEM) to in situ observation will be essential in the current and emerging data-driven materials science by taking STEM’s high affinity with various analytical options into account. As is well known, STEM’s image acquisition time needs to be further shortened to capture a targeted phenomenon in real-time as STEM’s current temporal resolution is far below the conventional TEM’s. However, rapid image acquisition in the millisecond per frame or faster generally causes image distortion, poor electron signals, and unidirectional blurring, which are obstacles for realizing video-rate STEM observation. Here we show an image correction framework integrating deep learning (DL)-based denoising and image distortion correction schemes optimized for STEM rapid image acquisition. By comparing a series of distortion corrected rapid scan images with corresponding regular scan speed images, the trained DL network is shown to remove not only the statistical noise but also the unidirectional blurring. This result demonstrates that rapid as well as high-quality image acquisition by STEM without hardware modification can be established by the DL. The DL-based noise filter could be applied to in-situ observation, such as dislocation activities under external stimuli, with high spatio-temporal resolution.

47 OTHER INSTRUMENTATION↗

Machine learning for reducing noise in RF control signals at industrial accelerators

Industrial particle accelerators typically operate in dirtier environments than research accelerators, leading to increased noise in RF and electronic systems. Furthermore, given that industrial accelerators are mass produced, less attention is given to optimizing the performance of individual systems. As a result, industrial accelerators tend to underperform their own hardware capabilities. Improving signal processing for these machines will improve cost and time margins for deployment, helping to meet the growing demand for accelerators for medical sterilization, food irradiation, cancer treatment, and imaging. Our work focuses on using machine learning techniques to reduce noise in RF signals used for pulse-to-pulse feedback in industrial accelerators. Here we review our algorithms and observed results for simulated RF systems, and discuss next steps with the ultimate goal of deployment on industrial systems.

43 PARTICLE ACCELERATORS↗

Charge-Density-Wave Thin-Film Devices Printed with Chemically Exfoliated 1T-TaS 2 Ink

In this work, we report on the preparation of inks containing fillers derived from quasi-two-dimensional charge-density-wave materials, their application for inkjet printing, and the evaluation of their electronic properties in printed thin-film form. The inks were prepared by liquid-phase exfoliation of CVT-grown 1T-TaS 2 crystals to produce fillers with nm-scale thickness and μm-scale lateral dimensions. Exfoliated 1T-TaS 2 was dispersed in a mixture of isopropyl alcohol and ethylene glycol to allow fine-tuning of filler particles thermophysical properties for inkjet printing. The temperature-dependent electrical and current fluctuation measurements of printed thin films demonstrated that the charge-density-wave properties of 1T-TaS 2 are preserved after processing. The functionality of the printed thin-film devices can be defined by the nearly commensurate to the commensurate charge-density-wave phase transition of individual exfoliated 1T-TaS 2 filler particles rather than by electron-hopping transport between them. The obtained results are important for the development of printed electronics with diverse functionality achieved by the incorporation of quasi-two-dimensional van der Waals quantum materials.

1T-TaS2↗

Electromagnetic Basis of Metabolism and Heredity

Living organisms control their cellular biological clocks to maintain functional oscillation of the redox cycle, also called the "metabolic cycle" or "respiratory cycle". Organization of cellular processes requires parallel processing on a synchronized time-base. These clocks coordinate the timing of all biochemical processes in the cell, including energy production, DNA replication, and RNA transcription. When this universal time keeping function is perturbed by exogenous induction of reactive oxygen species (ROS), the rate of metabolism changes. This causes oxidative stress, aging and mutations. Therefore, good temporal coordination of the redox cycle not only actively prevents chemical conflict between the reductive and oxidative partial reactions; it also maintains genome integrity and lifespan. Moreover, this universal biochemical rhythm can be disrupted by ROS induction in vivo. This in turn can be achieved by blocking the electron transport chain either endogenously or exogenously by various metabolites, e.g. hydrogen sulfide (H2S), highly diffusible drugs, and carbon monoxide (CO). Alternatively, the electron transport in vivo can be attenuated via a coherent or interfering transfer of energy from exogenous ultralow frequency (ULF) and extremely low frequency (ELF) electromagnetic (EM) fields, suggesting that-on Earth-such ambient fields are an omnipresent (and probably crucially important) factor for the time-setting basis of universal biochemical reactions in living cells. Our work demonstrated previously un-described evidence for quantum effects in biology by electromagnetic coupling below thermal noise at the universal electron transport chain (ETC) in vivo.

Electromagnetic↗

The Resource Prospector Neutron Spectrometer System: RP's Bloodhound

The primary goal of the Resource Prospector Neutron Spectrometer System (NSS) is to locate and characterize hydrogen-bearing volatile deposits, especially subsurface ice, that may exist at the lunar poles. A key objective is to detect water-equivalent hydrogen concentrations of 0.5 wt% or greater while on a moving rover. A second objective is to determine approximate burial depth of enhanced hydrogen-bearing materials up to 1 meter below otherwise dry regolith. The instrument will be carried aboard a landed mobility system at the lunar poles. The instrument operates by measuring the changes in the leakage flux of low energy neutrons out of the regolith. These neutrons are produced by galactic cosmic rays, which are so energetic that they shatter the nuclei in surface materials. The neutrons interact with other nuclei and lose energy, becoming thermalized in the process. Hydrogen is most efficient at thermalizing neutrons owing to protons' similar mass - statistically, neutrons lose half their energy per collision with protons. With hydrogen in the soil, leakage fluxes of neutrons in the 0.5 eV to 500 keV energy range are reduced. A concentration of only1-2 wt% water-equivalent hydrogen results in a decrease in epithermal leakage flux of a factor of two. The leakage flux of thermal neutrons, from 0 to 0.5 eV in energy, can either increase or decrease depending on the hydrogen abundance and stratigraphy. As with the highly successful Lunar Prospector Neutron Spectrometer, the RP NSS detects both thermal and epithermal neutrons by using two helium-3 gas proportional counters, one covered by cadmium and the other uncovered. The former detects only epithermal neutrons with energies above approximately 0.5 eV, the latter detects both thermal (less than 0.5 eV) and epithermal energies (greater than 0.5 eV). When a neutron enters the detector tube and interacts with a helium-3 nucleus, the resulting reaction produces an energetic proton and triton that ionize the gas. The resulting electrons are accelerated toward a high-voltage anode and cascade, amplifying the net charge, which is collected at the anode. The number of electrons produced is proportional to the energy that the triton and proton deposit in the gas. A charge sensitive pre-amplifier converts the total charge to a step voltage output. A shaper amplifier then shapes this step into a uni-polar waveform with peaking time appropriate for the detection depending on the event rate. The integrated shaped waveform, representing the deposited triton/proton energy, is then measured. A histogram, or pulse height analysis, is performed to record the main capture peak and wall effect pulses. A threshold for detection is also required to limit the low amplitude counting rate such as noise floor. The system electronics consists of 2 modules - the Sensor Module (SM) front-end and the Data Processing Module (DPM) back-end circuits. SM is designed as a light-weight and low power front-end housing the two helium-3 proportional counter detectors, preamp and HVPS. It is mounted external to the rover body to detect the thermalized neutron flux with a minimum of host background. The DPM is located inside the rover; it digitizes the SM signals, performs pulse height analysis and accumulates the count rate for each spectral channel. The DPM controls high voltage and thresholding, and sends the science data to the host craft via an RS422 serial asynchronous protocol. The payload host provides all thermal management and control for the SM and DPM.

hydrogen-bearing volatile deposits↗

Ultra low background time projection alpha particle detector ( Phase II Final Scientific/Technical Report)

When alpha particles are emitted into a gas they create an ionization track of gas ions and electrons. In our commercial UltraLo instrument we apply a voltage between a planar sample and an anode, integrate the anode signal as it collects the electrons, and distinguish between alphas emitted from the sample and elsewhere (anode, sidewalls) by the duration and shape of the resultant signal. The major contributors limiting the instrument’s lower detection limit are cosmic rays that pass through the detector close to the sample and Rn decays that produce charge tracks the originate in the gas and end on the sample. In this work we proposed to identify and reject these events by converting the anode into a multi-pixel array and operating in time projection mode. Cosmic rays would be eliminated by generating charge on many pixels, while charge collection asymmetry would distinguish between sample events (Bragg curve up) and Rn events (Bragg curve down). We therefore proposed to modify an UltraLo by pixilating its anode, developing low noise, low power multiplexed electronics to track each pixel’s signal individually, and develop analysis software to make the required discriminations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focal-plane optimization for detector noise limited performance in cryogenic Fourier transform spectrometer /FTS/ sensors

A study was performed to determine the optimum focal plane configuration including optics, filters and detector-preamplifier selection. The configuration was optimized particularly with respect to minimizing the noise level, but fabrication considerations for a cryogenic environment were also taken into account. The noise terms from source, background, detector electronics and charged particle radiation were quantitatively evaluated. It appears that noise equivalent spectral radiance less than 10 to the -11th W/sq cm per sr per kayser can be achieved between 2.5 and 20 microns.

Mcguirk, M.↗

Fidelity Analysis of Sampled Imaging Systems

Many modeling, simulation and performance analysis studies of sampled imaging systems are inherently incomplete because they are conditioned on a discrete-input, discrete-output model that only accounts for blurring during image acquisition and additive noise. For those sampled imaging systems where the effects of digital image acquisition, digital filtering and reconstruction are significant, the modeling, simulation and performance analysis should be based on a more comprehensive continuous-input, discrete-processing, continuous-output end-to-end model. This more comprehensive model should properly account for the low-pass filtering effects of image acquisition prior to sampling, the potentially important noiselike effects of the aliasing caused by sampling, additive noise due to device electronics and quantization, the generally high-boost filtering effects of digital processing, and the low-pass filtering effects of image reconstruction. This model should not, however, be so complex as to preclude significant mathematical analysis, particularly the mean-square (fidelity) type of analysis so common in linear system theory. We demonstrate that, although the mathematics of such a model is more complex, the increase in complexity is not so great as to prevent a complete fidelity-metric analysis at both the component level and at the end-to-end system level: that is, computable mean-square-based fidelity metrics are developed by which both component-level and system-level performance can be quantified. In addition, we demonstrate that system performance can be assessed qualitatively by visualizing the output image as the sum of three component images, each of which relates to a corresponding fidelity metric. The cascaded, or filtered, component accounts for the end-to-end system filtering of image acquisition, digital processing, and image reconstruction; the random noise component accounts for additive random noise, modulated by digital processing and image reconstruction filtering; and the aliased noise component accounts for the frequency folding effect of sampling, modulated by digital processing and image reconstruction filtering.

Park, Stephen K.↗

EMITTANCE GROWTH DUE TO RF PHASE NOISE IN CRAB CAVITIES

The Electron-Ion Collider (EIC) incorporates beam crabbing to recover geometric luminosity loss from the nonzero crossing angle at the interaction point (IP). It is well-known that crab cavity imperfections can cause growth of colliding beam emittances, thus degrading collider performance. Here we report a particle tracking study to quantify these effects. Presently the study is focused on crab cavity RF phase noise. Simulations were carried out using Bmad. Dependence of emittance growth on phase noise level was obtained which could be used for developing crab cavity phase control specifications. We also benchmarked these simulations with theory.

Huang, H.↗

Development of Submillimeter SIS Mixers and Broadband HEMT Amplifiers

This is the final technical report for NASA grant NAG5-9493. entitled "Development of Submillimeter SIS Mixers and Broadband HEMT Amplifiers". The goal of this project was to develop and demonstrate a new generation of superconducting tunnel junction (SIS) receivers with extremely wide instantaneous (intermediate-frequency, or IF) bandwidths. of order 12 GHz. along with the wideband low-noise microwave HEMT (high electron mobility transistor) amplifiers which follow the SIS mixer. These wideband SIS/HEMT receivers would allow rapid submillimeter wavelength spectral line surveys to be carried out, for instance with the NASA airborne observatory SOFIA. and could potentially be useful for future submillimeter space missions such as SAFIR. In addition, there are potential NASA earth science applications. such as the monitoring of the distribution of chemical species in the stratosphere and troposphere using the limb-sounding technique. The overall goals of this project have been achieved: a broadband 200-300 SIS receiver was designed and constructed, and was demonstrated in the field through a test run at the Caltech Submillimeter Observatory on Mauna Kea. HI. The technical details are described in the appendices. which are primarily conference publications. but Appendix A also includes an unpublished summary of the latest results. The work on the SIS mixer design are described in the conference publications (appendices B and C). The "Supermix" software package that was developed at Caltech and used for the SIS design is also described in two conference papers, but has been substantially revised, debugged. and extended as part of the work completed for this grant. The Supermix package is made available to the community at no charge. The electromagnetic design of a radial waveguide probe similar to the one used in this work is described in a journal publication. Details of the novel fabrication procedure used for producing the SIS devices at JPL are also given in an upcoming journal article. Finally, details on the wideband HEMT amplifier design and noise characterization techniques are described in two publications.

Zmuidzinas, J.↗

Studies to Improve the Sensitivity to Low Energy Interactions in Dual-Phase Xenon Dark Matter Detectors. Department of Energy Office of Science Graduate Student Research (SCGSR) Program, Final project report

Noble liquid time projection chambers (TPCs) are some of the most sensitive particle detectors ever developed. They see use in searches for new physics with neutrinos, or for new particles like dark matter. They work by sensing light and charge signals left behind by particle interactions in a volume of liquified xenon or argon. TPCs are so sensitive that even a single electron liberated in an interaction can be readily detected. However this sensitivity to signals comes with a sensitivity to background noise, with one example being single electrons that arrive long after the signals from a true particle interaction. This type of noise has been the subject of multiple studies, which have concluded that single electron backgrounds are well correlated with prior events in the TPC, as well as impurities in the detection medium. At Lawrence Livermore National Laboratory (LLNL), the XeNu TPC is a testbed for a novel study of these backgrounds by generating data with new components made of aluminum and Shapal--the latter being an exotic ceramic which can be machined using standard tools. These materials were selected to replace plastic components which introduce impurities in the TPC during operation. Without plastic, the hope is that electron backgrounds will be reduced, leaving new opportunities for studying their origins and dependence on impurities. The SCGSR fellowship served as a springboard to help meet these objectives. Over the course of a year, the new components were designed, fabricated, and installed in XeNu. Following their installation, data was taken for use in a future study that will enable the electron background contributions from plastic components to be studied directly. In the interim, preliminary analysis results indicate that electron backgrounds with the new components are roughly 50% lower. This has established the efficacy of Shapal as a low-background replacement for plastic components where electrical and thermal stability are needed

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronic thermal transport measurement in low-dimensional materials with graphene non-local noise thermometry

In low-dimensional systems, the combination of reduced dimensionality, strong interactions and topology has led to a growing number of many-body quantum phenomena. Thermal transport, which is sensitive to all energy-carrying degrees of freedom, provides a discriminating probe of emergent excitations in quantum materials and devices. However, thermal transport measurements in low dimensions are dominated by the phonon contribution of the lattice, requiring an experimental approach to isolate the electronic thermal conductance. In this work we measured non-local voltage fluctuations in a multi-terminal device to reveal the electronic heat transported across a mesoscopic bridge made of low-dimensional materials. Using two-dimensional graphene as a noise thermometer, we measured the quantitative electronic thermal conductance of graphene and carbon nanotubes up to 70 K, achieving a precision of ~1% of the thermal conductance quantum at 5 K. Employing linear and nonlinear thermal transport, we observed signatures of energy transport mediated by long-range interactions in one-dimensional electron systems, in agreement with a theoretical model.

36 MATERIALS SCIENCE↗

Cryogenic Front-End ASICs for Low-Noise Readout of Charge Signals

This paper presents design details and measurement results of LArASIC, a front-end application specific integrated circuit (ASIC) designed for low-noise readout of charge signals generated in neutrino study experiments within liquid argon time projection chambers. LArASIC comprises of 16-channels of programmable charge amplification and pulse shaping stages that provide a voltage readout proportional to the input charge and was optimized for operation at liquid argon temperature, i.e., 89 K. The chip was fabricated in a 180 nm CMOS process. Measurements at liquid nitrogen temperature, i.e., 77 K, indicate that the channel outputs have high linearity (INL < 0.1%) within the operating range, an equivalent noise charge of 534 electrons for a peaking time of 1 µs and a detector capacitance of 150 pF, and a worst-case inter-channel cross-talk of 0.35%. The paper also presents design choices made in the process of migrating LArASIC to CHARMS, an ASIC to be fabricated in a 65 nm process that includes all features provided by LArASIC, along with additional digital programmability for improved robustness and flexibility. CHARMS is intended for use in future high-energy physics experiments that require high-resolution charge or light readout with shorter pulse peaking times.

47 OTHER INSTRUMENTATION↗

Radiation noise in a high sensitivity star sensor

An extremely accurate attitude determination was developed for space applications. This system uses a high sensitivity star sensor in which the photomultiplier tube is subject to noise generated by space radiations. The space radiation induced noise arises from trapped electrons, solar protons and other ionizing radiations, as well as from dim star background. The solar activity and hence the electron and proton environments are predicted through the end of the twentieth century. The available data for the response of the phototube to proton, electron, gamma ray, and bremsstrahlung radiations are reviewed and new experimental data is presented. A simulation was developed which represents the characteristics of the effect of radiations on the star sensor, including the non-stationarity of the backgrounds.

Parkinson, J. B.↗