Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic conductivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Improved Anode for a Direct Methanol Fuel Cell

A modified chemical composition has been devised to improve the performance of the anode of a direct methanol fuel cell. The main feature of the modified composition is the incorporation of hydrous ruthenium oxide into the anode structure. This modification can reduce the internal electrical resistance of the cell and increase the degree of utilization of the anode catalyst. As a result, a higher anode current density can be sustained with a smaller amount of anode catalyst. These improvements can translate into a smaller fuel-cell system and higher efficiency of conversion. Some background information is helpful for understanding the benefit afforded by the addition of hydrous ruthenium oxide. The anode of a direct methanol fuel cell sustains the electro-oxidation of methanol to carbon dioxide in the reaction CH3OH + H2O--->CO2 + 6H(+) + 6e(-). An electrocatalyst is needed to enable this reaction to occur. The catalyst that offers the highest activity is an alloy of approximately equal numbers of atoms of the noble metals platinum and ruthenium. The anode is made of a composite material that includes high-surface-area Pt/Ru alloy particles and a proton-conducting ionomeric material. This composite is usually deposited onto a polymer-electrolyte (proton-conducting) membrane and onto an anode gas-diffusion/current-collector sheet that is subsequently bonded to the proton-conducting membrane by hot pressing. Heretofore, the areal density of noble-metal catalyst typically needed for high performance has been about 8 mg/cm2. However, not all of the catalyst has been utilized in the catalyzed electro-oxidation reaction. Increasing the degree of utilization of the catalyst would make it possible to improve the performance of the cell for a given catalyst loading and/or reduce the catalyst loading (thereby reducing the cost of the cell). The use of carbon and possibly other electronic conductors in the catalyst layer has been proposed for increasing the utilization of the catalyst by increasing electrical connectivity between catalyst particles. However, the relatively low density of carbon results in thick catalyst layers that impede the mass transport of methanol to the catalytic sites. Also, the electrical conductivity of carbon is less than 1/300th of typical metals. Furthermore, the polymer-electrolyte membrane material is acidic and most metals are not chemically stable in contact with it. Finally, a material that conducts electrons (but not protons) does not contribute to the needed transport of protons produced in the electro-oxidation reaction.

Valdez, Thomas↗

Image Processing

Electronic Imagery, Inc.'s ImageScale Plus software, developed through a Small Business Innovation Research (SBIR) contract with Kennedy Space Flight Center for use on space shuttle Orbiter in 1991, enables astronauts to conduct image processing, prepare electronic still camera images in orbit, display them and downlink images to ground based scientists for evaluation. Electronic Imagery, Inc.'s ImageCount, a spin-off product of ImageScale Plus, is used to count trees in Florida orange groves. Other applications include x-ray and MRI imagery, textile designs and special effects for movies. As of 1/28/98, company could not be located, therefore contact/product information is no longer valid.

Source record↗

Thermal response of the F region ionosphere in artificial modification experiments by HF radio waves

The thermal response of the nighttime F region ionosphere to local heating by HF radio waves has been observed with the incoherent scatter radar at Arecibo, Puerto Rico. The observations consist of high-resolution space and time variation of the electron temperature as a high-power HF transmitter is switched on and off with a period 240 s. As soon as the HF transmitter is turned on, the electron temperature begins to rise rapidly in a narrow altitude region near 300 km, below the F2 layer peak. The electron temperature perturbation subsequently spreads over a broader altitude region. The observations are compared with the anticipated thermal response of the ionosphere based on numerical solutions of the coupled time-dependent heat conduction equations for the electron and composite ion gases and are found to be in good agreement over the entire altitude region covered by the observations.

Mantas, G. P.↗

Adhesion and friction of transition metals in contact with nonmetallic hard materials

Sliding friction experiments were conducted with the metals yttrium, titanium, tantalum, zirconium, vanadium, neodymium, iron, cobalt, nickel, tungsten, platinum, rhenium, ruthenium, and rhodium in sliding contact with single crystal diamond, silicon carbide, pyrolytic boron nitride, and ferrite. Auger electron spectroscopy analysis was conducted with the metals and nonmetals to determine the surface chemistry and the degree of surface cleanliness. The results of the investigation indicate the adhesion and friction of the transition metals in contact with diamond, silicon carbide, boron nitride, and ferrite are related to the relative chemical activity of the metals. The more chemically active the metal, the higher the coefficient of friction and the greater amount of transfer to the nonmetals.

Miyoshi, K.↗

Suprathermal electrons produced by beam-plasma-discharge

Experiments conducted with a low energy plasma lens, HARP, in the electron beam of the large vacuum chamber at Johnson Space Center indicate that an enhanced population of 50 to 300 volt electrons appear when the beam goes into the Beam-Plasma Discharge (BPD) mode. Below the BPD instability the electron distribution appears to be characterized as non-energized single particle scattering and energy loss. At 100 cm from the beam core in the BPD mode the fluxes parallel to the beam are reduced by a factor of 20 with respect to the fluxes at 25 cm. Some evidence for isotropy near the beam core is presented.

Sharp, W. E.↗

Conductive Tether Coating for Electrodynamic Tethers

The Propulsive Small Expendable Deployer System (ProSEDS), which is an on-orbit demonstration of the propulsion capabilities of electrodynamic tethers in space, is a secondary payload on a Delta 11 unmanned expendable booster. The ProSEDS tether consists of a 5 km bare electrodynamic tether and a 1 0-km non-conductive leader tether. Near the Delta 11, 160 m of the conductive tether is insulated to prevent plasma electron collection from the plasma contactor and for other science requirements. The remainder of the 5-km conductive tether is coated with a new conductive coating to collect plasma electrons. A bare metal tether easily collects electrons from the plasma, but thermal concerns preclude this design. A highly emissive conductive polymer developed by Triton Systems, Inc. has been optimized for both conductivity and thermo-optical properties. The current design for the ProSEDS conductive tether is seven individually coated strands of 28 AWG aluminum wire, coated with an atomic oxygen-resistant conductive polymer composed of a mixture of COR (Colorless Oxygen Resistant) and polyanaline (PANI) known as C-COR (Conductive-Colorless Oxygen Resistant). The conductive-coated wire strands are cold-welded to individually coated strands of the insulated tether. The insulated tether is coated with 1 mil of polyimide and an atomic oxygen resistant polymer TOR-BP. The insulated tether must stand off the entire voltage of the tether (1 200 V) at various times during the mission. All seven wires are twisted around a Kevlar-29 core using the Hi-wire design. Extensive testing has been performed at the Marshall Space Flight Center to qualify both the conductive coating and insulating coating for use on the ProSEDS tether. The conductive coating has been exposed to a plasma to verify the coatings ability to collect electrons from the space plasma from 0 to 1500 V, and to verify the coatings ability to collect electrons after atomic oxygen exposure. The insulated coating has been tested to verify its dielectric strength both in a vacuum and air. Thermal optical properties on both coatings have been measured before and after atomic oxygen testing. The results of these tests will be presented.

Jason A Vaughn↗

Ogo 6 measurements of supercooled plasma in the equatorial exosphere.

Plasma measurements performed on Ogo 6 reveal electron and ion temperature values that on occasion appear to be well below the expected neutral gas temperature. The phenomenon is observed only at night above 500 km near the magnetic equator. It is suggested that the expansion cooling of the plasma is accomplished by downward motions of the F region plasma induced by winds or diffusion, by outward E x B drift, or more probably by the upward flow of plasma during interhemisphere transport along magnetic field lines. It is also suggested that preferential cooling of electrons because of their greater thermal conductivity should tend to give ion temperatures greater than electron temperatures during the postsunset cooling of the plasmasphere when photoelectrons are absent.

Hanson, W. B.↗

Low-Noise Wide Bandwith, Hot Electron Bolometer Mixers for Submillimeter Wavelengths

Recently a novel superconductive hot-electron micro-bolometer has been proposed which is both fast and sensitive (D. E. Prober, Appl. Phys. Lett. 62, 2119, 1993). This device has several important properties which make it useful as a heterodyne sensor for radioastronomy applications at frequencies above 1 THz. The thermal response time of the device is fast enough, several 10's of picoseconds, to allow for IF's of several GHz. This bolometer mixer should operate well up to at least 10 THz. There is no energy gap limitation as in an SIS mixer, since the mixing process relies on heating of the electron gas. In fact, rf power is absorbed more uniformly above the gap frequency. The mixer noise should be near quantum-limited, and the local oscillator (LO) power requirement is very low: / 10 nW for a Nb device. One of the unique features of this device is that it employs rapid electron diffusion into a normal metal, rather than phonon emission, as the thermal conductance that cools the heated electrons. In order for diffusion to dominate over phonon emission, the device must be short, less than 0.5.

Bolometer Mixers↗

The multiple applications of electrons in space

An electron source such as a simple cathode is a cheap and light device which can serve several technological and scientific purposes in space: (1) electrostatic charging of a spacecraft can be limited by releasing electrons accumulated on the conductive elements of their surface; (2) the erosion of conductive coatings and the ability of conductive paints to withstand the space environment can be evaluated by monitoring the flow of charged particles impinging on their surface; (3) measuring the current collected by the spacecraft surface as a function of its potential with respect to an emitter is a very sensitive diagnostic technique which can yield a number of plasma parameters, such as density and temperature; (4) it is possible to convert the thermal motion of space plasmas into electrical energy by collecting energetic electrons and returning them to the medium as cold particles; (5) a wave in a plasma is characterized by a conduction current density which gives rise to fluctuations of the current flowing to the surface.

Grard, R. J. L.↗

Dynamic SEM wear studies of tungsten carbide cermets

Dynamic friction and wear experiments were conducted in a scanning electron microscope. The wear behavior of pure tungsten carbide and composite with 6 and 15 weight percent cobalt binder was examined. Etching of the binder was done to selectively determine the role of the binder in the wear process. Dynamic experiments were conducted as the WC and bonded WC cermet surfaces were transversed by a 50 micron radiused diamond stylus. These studies show that the predominant wear process in WC is fracture initiated by plastic deformation. The wear of the etched cermets is similar to pure WC. The presence of the cobalt binder reduces both friction and wear. The cementing action of the cobalt reduces granular separation and promotes a dense polished layer because of its low shear strength film-forming properties. The wear debris generated from unetched surface is approximately the same composition as the bulk.

Brainard, W. A.↗

Dynamic SEM wear studies of tungsten carbide cermets

Dynamic friction and wear experiments were conducted in a scanning electron microscope. The wear behavior of pure tungsten carbide and composite with 6 and 15 weight percent cobalt binder was examined, and etching of the binder was done to selectively determine the role of the binder in the wear process. Dynamic experiments were conducted as the tungsten carbide (WC) and bonded WC cermet surfaces were transversed by a 50 micron radiused diamond stylus. These studies show that the predominant wear process in WC is fracture initiated by plastic deformation, and the wear of the etched cermets is similar to pure WC. The presence of the cobalt binder reduces both friction and wear. The cementing action of the cobalt reduces granular separation, and promotes a dense polished layer because of its low shear strength film-forming properties. The wear debris generated from unetched surface is approximately the same composition as the bulk.

Brainard, W. A.↗

NASA-DoD Lead-Free Electronics Project: Vibration Test

Vibration testing was conducted by Boeing Research and Technology (Seattle) for the NASA-DoD Lead-Free Electronics Solder Project. This project is a follow-on to the Joint Council on Aging Aircraft/Joint Group on Pollution Prevention (JCAA/JG-PP) Lead-Free Solder Project which was the first group to test the reliability of lead-free solder joints against the requirements of the aerospace/miLItary community. Twenty seven test vehicles were subjected to the vibration test conditions (in two batches). The random vibration Power Spectral Density (PSD) input was increased during the test every 60 minutes in an effort to fail as many components as possible within the time allotted for the test. The solder joints on the components were electrically monitored using event detectors and any solder joint failures were recorded on a Labview-based data collection system. The number of test minutes required to fail a given component attached with SnPb solder was then compared to the number of test minutes required to fail the same component attached with lead-free solder. A complete modal analysis was conducted on one test vehicle using a laser vibrometer system which measured velocities, accelerations, and displacements at one . hundred points. The laser vibrometer data was used to determine the frequencies of the major modes of the test vehicle and the shapes of the modes. In addition, laser vibrometer data collected during the vibration test was used to calculate the strains generated by the first mode (using custom software). After completion of the testing, all of the test vehicles were visually inspected and cross sections were made. Broken component leads and other unwanted failure modes were documented.

Woodrow, Thomas A.↗

A two-fluid model for solar wind fluid with higher order moments

A spherically symmetric two-fluid model for the solar wind with higher-order moments is presented. In this model, continuity, momentum, temperature and heat flux equations for two components (electrons and protrons) in steady solar wind states are simultaneously solved by using a time-dependent method. This work is used to compare solutions of the steady-state solar wind with and without higher order moments, and to study the effects of thermal conduction. The coupling between electrons and protrons is also given special attention. The numerical solutions of the steady-state solar wind in both subsonic and supersonic regions between the Sun and 1 AU are obtained and graphically illustrated.

Wang, Jingfang↗

Measurement of volt/meter vertical electric fields in the middle atmosphere

A test flight for a series of middle atmosphere electrodynamics rockets was launched from Wallops Island, Virginia, at 7:18 EST on July 31, 1980. The mother-daughter configuration contained a three axis symmetric double probe electric field instrument and a blunt probe on the daughter payload, and a Gerdien condenser and a single axis (vertical) asymmetric double probe electric field instrument on the mother payload. The payloads reached an apogee of 111 km, and data were gathered from all instruments on the downleg. A downward vertical electric field with a maximum amplitude of about 4 V/m was observed in a layer between about 57 and 67 km. The integrated potential across this layer was approximately 20 kV. Conductivity measurements indicated that free electrons were absent from the region of large electric fields; however, the decrease in conductivity was insufficient to maintain vertical current continuity through the layer. These results establish the existence of large mesospheric electric fields, supporting previous results from single axis measurements.

Maynard, N. C.↗

Studies of beam plasma interactions in a space simulation chamber using prototype Space Shuttle instruments

In March, 1981, electron beam experiments were conducted in a large space simulation chamber using equipment destined to be flown aboard NASA's Office of Space Science-1 pallet (OSS-1). Two major flight experiments were involved. They include the Vehicle Charging and Potential (VCAP) experiment and the Plasma Diagnostics Package (PDP). Apparatus connected with VCAP included a Fast Pulse Electron Gun (FPEG), and a Charge and Current Probe (CCP). A preliminary view is provided of the results obtained when the electron emissions were held steady over relatively long periods of time such that steady state conditions could be obtained with respect to the electron beam interaction with the neutral gases and plasma of the vacuum chamber. Of particular interest was the plasma instability feature known as the Beam Plasma Discharge. For the present experiments the FPEG was used in a dc mode with a range of currents of 2 to 80 mA at a beam energy of 970 eV. Attention is given to the emissions of VLF and HF noise associated with the dc beam.

Banks, P. M.↗