Algorithm For Detecting dc Series Arcs

Algorithm developed for use in automatic detection of dc series arcs in power cables, cable terminations, and junction boxes. (Sometimes detects arcs inside electrical loads.) System in which algorithm utilized is one receiving power from microprocessor-based remote power controller that includes load-current sensor. Algorithm analyzes digitized load-current readings for fluctuations characteristic of dc series arcs.

Moores, Greg L.↗

Railroad block/grade crossing warning system

A train safety system comprises a cable connected to at least two conducting contacts, an electrical load between said two conducting magnetic contacts, and a DC track circuit associated with railroad tracks wherein the at least two conducting plates can be connected to each of the railroad rails in order to shunt the DC track circuit and alert oncoming trains of fouling of the tracks or crossing ahead.

42 ENGINEERING↗

A turnkey gaseous helium-cooled superconducting CORC ® dc power cable with integrated current leads

Abstract High-temperature superconducting (HTS) direct current (dc) power cable systems, capable of delivering power exceeding 10 MW while being cooled with cryogenic helium gas, have been developed for applications on naval electric ships, electric aircraft and in data centers. Current injection from room temperature into the superconducting power cable causes by far the greatest heat load to the cryogenic system. Efficient current leads with integrated helium gas heat exchangers were developed to inject a current exceeding 1 kA from room temperature into a superconducting Conductor on Round Core (CORC ® ) power cable, without the need for liquid nitrogen pre-cooling. A 2 m long single-pole CORC ® power cable system that included current leads was cooled using a Stirling cryocooler with a closed-loop helium gas circulation system. The turnkey power cable system allowed cool down from room temperature to its operating temperature of 60 K–70 K within 5 h, after which continuous operation at 1.2 kA was demonstrated. The successful development and demonstration of a CORC ® power cable with current leads containing integrated helium gas heat exchangers enables widespread implementation of HTS MW-class, high current density superconducting dc power cables in many applications with constrained space that require a power dense solution.

Physics↗

Fiber optic multiplex optical transmission system

A multiplex optical transmission system which minimizes external interference while simultaneously receiving and transmitting video, digital data, and audio signals is described. Signals are received into subgroup mixers for blocking into respective frequency ranges. The outputs of these mixers are in turn fed to a master mixer which produces a composite electrical signal. An optical transmitter connected to the master mixer converts the composite signal into an optical signal and transmits it over a fiber optic cable to an optical receiver which receives the signal and converts it back to a composite electrical signal. A de-multiplexer is coupled to the output of the receiver for separating the composite signal back into composite video, digital data, and audio signals. A programmable optic patch board is interposed in the fiber optic cables for selectively connecting the optical signals to various receivers and transmitters.

Bell, C. H.↗

Low-Heat-Leak Electrical Leads For Cryogenic Systems

Electrical leads offering high electrical conductivity and low thermal conductivity developed for use in connecting electronic devices inside cryogenic systems to power supplies, signal-processing circuits, and other circuitry located in nearby warmer surroundings. Strip of superconductive leads on ceramic substrate, similar to ribbon cable, connects infrared detectors at temperature of liquid helium with warmer circuitry. Electrical leads bridging thermal gradient at boundary of cryogenic system designed both to minimize conduction of heat from surroundings through leads into system and to minimize resistive heating caused by electrical currents flowing in leads.

Wise, Stephanie A.↗

Novel Processing, Testing and Characterization of Copper/Carbon Nanotube (Cu/CNT) Yarn Composite Conductor

Sustainable electrified aircraft propulsion (EAP) is likely to lead to an increase in the electrical wiring contained within a single aircraft. Since the electrical resistance and mass of copper (Cu) conductors are associated with power losses, it is desirable to design high-conductivity lightweight conductor materials, thus reducing the mass of components like motor windings, low-voltage signal cables, and transmission cables for data and power to improve the overall energy efficiency. This paper describes a unique framework for manufacturing metalized carbon nanotube (CNT) composite conductors, measuring their electrical conductivity and strength, and modeling the overall conductivity and current sharing within such composites. Tensile testing was conducted on the processed composite conductor cables with the use of acoustic emission and electrical resistivity to determine stress-dependent-failure mechanisms while monitoring the electrical conductivity. The average of measured electrical conductivities of annealed Cu/CNT samples from batch 5 was greater than theoretical predictions by 9.8 percent and was also greater than the conductivity of pure annealed Cu by 4.8 percent and had comparable ultimate tensile strengths. Additionally, those Cu/CNT samples provide a 13.5% weight saving over current state of the art copper wires. Theories explaining improved intrinsic conductivity are discussed.

Metalized CNT↗

Installation and Assembly, Electrical Ground Support Equipment (GSE), Specification for

This specification covers the general workmanship requirements and procedures for the complete installation and assembly of electrical ground support equipment (EGSE) such as terminal distributors, junction boxes, conduit and fittings, cable trays and accessories, interconnecting cables (including routing requirements), motor-control equipment, and necessary hardware as specified by the applicable contract and drawings.

Electrical and Electronics↗

Report on High Energy Arcing Fault Experiments

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for medium voltage electrical switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers four of the fourteen planned medium voltage electrical enclosure experiments. Subsequent reports will document the additional experiments performed in the future. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the United States Nuclear Regulatory Commission (NRC), the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setups and execution. The HEAF experiments were performed on four near-identical units of General Electric metal-clad medium voltage switchgear. The three-phase arcing fault was initiated on the primary cable connection bus. All four experiments used the same system voltage (6.9 kV) but varied the current and duration. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers and slug calorimeters at various locations around the electrical enclosures. Internal enclosure pressures were measured during the experiments. The experiments were documented with normal and high-speed videography, infrared imaging, and photography. Insights from the experimental series included timing information related to enclosure breach, event progression, mass loss measurements for electrodes and steel enclosures, peak pressure rise, particle analysis, along with visual and thermal imaging data to better understand and characterize the hazard. These results will be used in subsequent efforts to advance the state of knowledge related to HEAF.

42 ENGINEERING↗

Cable coupling lightning transient qualification

Simulated lightning strike testing of instrumentation cabling on the redesigned solid rocket motor was performed. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of instrumentation cable transients on cables within the system tunnel. The maximum short-circuit current induced onto a United Space Boosters, Inc., operational flight cable within the systems tunnel was 92 A, and the maximum induced open-circuit voltage was 316 V. These levels were extrapolated to the worst-case (200 kA) condition of NASA specification NSTS 07636 and were also scaled to full-scale redesigned solid rocket motor dimensions. Testing showed that voltage coupling to cables within the systems tunnel can be reduced 40 to 90 dB and that current coupling to cables within the systems tunnel can be reduced 30 to 70 dB with the use of braided metallic sock shields around cables that are external to the systems tunnel. Testing also showed that current and voltage levels induced onto cables within the systems tunnel are partially dependant on the cables' relative locations within the systems tunnel. Results of current injections to the systems tunnel indicate that the dominant coupling mode on cables within the systems tunnel is not from instrumentation cables but from coupling through the systems tunnel cover seam apertures. It is recommended that methods of improving the electrical bonding between individual sections of the systems tunnel covers be evaluated. Further testing to better characterize redesigned solid rocket motor cable coupling effects as an aid in developing methods to reduce coupling levels, particularly with respect to cable placement within the systems tunnel, is also recommended.

Cook, M.↗

Assessment of Regional Interconnections to Meet Southeast Asia's Renewable Energy Targets: Phase I of the Singapore – U.S. Collaboration

This report summarizes the results of a study of long-distance subsea electrical interconnections in Southeast Asia, conducted under the first phase of the Singapore-U.S. collaboration under the Net Zero World Initiative. In Phase 1, the Net Zero World team evaluated the current state of the renewable energy landscape in Southeast Asia; developed an open-source capacity expansion model using GridPath and evaluated several future scenarios including changes in interregional transmission; explored the technical feasibility of regional subsea interconnectors; and estimated socio-economic benefits of expanded regional transmission.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Rectangular configuration improves superconducting cable

Superconducting cable for a cryogenic electromagnet with improved mechanical and thermal properties consists of a rectangular cross-sectioned combination of superconductor and normal conductor. The conductor cable has superconductors embedded in a metallic coating with high electrical and mechanical conductivity at liquid helium temperatures.

Foss, M.↗

Current waveforms analyses of lightning flashes triggered by the rocket and wire technique

Presented in this paper are the main results of the 1987 Rocket Triggered Lightning Program (RTLP) in Florida: I greater than 60 kA, DI/DT greater than 400 kA/micro-S. Optical and electrical observations from flashes triggered by grounded wire or insulating cable (200 m) rocket technique are presented. Correlation between I and DI/DT measurements are presented and discussed. These measurements were carried out with the same grounded wire rocket technique in Florida in 1985, 1987, and in France in 1986.

Eybert-Berard, A.↗

Cascaded resonant bridge converters

A converter for converting a low voltage direct current power source to a higher voltage, high frequency alternating current output for use in an electrical system where it is desired to use low weight cables and other circuit elements. The converter has a first stage series resonant (Schwarz) converter which converts the direct current power source to an alternating current by means of switching elements that are operated by a variable frequency voltage regulator, a transformer to step up the voltage of the alternating current, and a rectifier bridge to convert the alternating current to a direct current first stage output. The converter further has a second stage series resonant (Schwarz) converter which is connected in series to the first stage converter to receive its direct current output and convert it to a second stage high frequency alternating current output by means of switching elements that are operated by a fixed frequency oscillator. The voltage of the second stage output is controlled at a relatively constant value by controlling the first stage output voltage, which is accomplished by controlling the frequency of the first stage variable frequency voltage controller in response to second stage voltage. Fault tolerance in the event of a load short circuit is provided by making the operation of the first stage variable frequency voltage controller responsive to first and second stage current limiting devices. The second stage output is connected to a rectifier bridge whose output is connected to the input of the second stage to provide good regulation of output voltage wave form at low system loads.

Stuart, Thomas A.↗

Simulation for the fault current limiting operation of REBCO CORC superconducting cables with different core materials

With high power density and low loss, CORC superconducting cables composed of RE- Ba 2 Cu 3 O 7–δ (REBCO) coated conductors are of great interest for power transmission applications. They can also effectively be designed to serve as fault current limiters, thanks to their sharp superconducting-to-normal transition. Coupled electromagnetic-thermal finite element (FE) simulations implemented in COMSOL Multiphysics were developed and validated against the published results for the fault current limiting performance of two CORC cables of REBCO coasted conductors wound on either copper or stainless steel cores. For improved accuracy, temperature dependencies of electrical and thermal properties of all component materials were considered in the simulations. The simulations were performed in the cross-sections of the cables for every individual layer of each REBCO tape to deliver comprehensive understanding of evolution of the current distribution and temperature rise in those layers. Furthermore, the studies can suggest approaches to optimize cable design for fault current limiting (FCL) applications by assessing the role of individual components. In the paper, possible computational errors, challenges and improvements are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SpaceWire Cable and Connector Variations. Session: SpaceWire Components

This viewgraph presentation reviews issues about SpaceWire cable and connectors. Discussion in the talk concerned connector specifications and cable specifications. The Connector Specification issues are: (1) Not impedance matched to the cable (2) Handling (Mechanical) issues (3) Need space-qualified matched impedance connector (4) alternative space-qualified connector and Electrical Issues (5) Only a single ground pin which does not pass through (6) Near-end Crosstalk (NEXT) at the SpaceWire connector Cable Specification issue concerns the use of larger gauge cable in non-standard applications or to meet tight specifications

Allen, Shaune S.↗

Intramuscular Contact Lead Filled With Conductive Solution

Proposed sheath for braided-wire intramuscular conductor preserves electrical continuity even if wire breaks. Plastic sheath surrounds conductive solution in which braided wire immersed. At end of cable, wire and sheath crimped together and press-fit in porous titanium electrode. Implanted surgically with aid of device resembling catheter. Used to deliver electrical stimuli to muscles in biomedical research on human and animal physiology, development of prostheses, regeneration of nerves and muscles, and artificial implants.