Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dual imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

High-Spatial-Resolution OH and CH2O PLIF Visualization in a Dual-Mode Scramjet Combustor

A high-spatial-resolution planar laser-induced fluorescence (PLIF) imaging system was constructed and used to image a cavity-stabilized, premixed ethylene-air flame. The flame was created within a continuous flow, electrically-heated supersonic combustion facility consisting of a Mach 2 nozzle, an isolator with flush-wall fuel injectors, a combustor with a cavity flameholder of height 9 mm and optical access, and an extender. Tests were conducted at total temperature 1200 K, total pressure 300 kPa, equivalence ratio near 0.4 in the combustor, and Mach number near 0.6 in the combustor. A frequency-doubled Nd:YAG laser pumped a dye laser, which produced light at 283.55 nm. The beam was shaped into a light sheet with full width half-maximum 25 microns, which illuminated a streamwise plane that bisected the cavity. An intensified camera system imaged OH in this plane with a square 6.67 mm field of view and in-plane resolution 39 microns. Images were taken between the backward-facing step and 120 mm downstream of the step. OH structures as small as 110 microns were observed. CH2O was excited using 352.48 nm light; the smallest observed CH2O structures were approximately 200 microns wide. Approximately 15,000 images per species were processed and used to compute composite images.

Geipel, Clayton M.↗

Physics‐based iterative reconstruction for dual‐source and flying focal spot computed tomography

Purpose For single‐source helical Computed Tomography (CT), both Filtered‐Back Projection (FBP) and statistical iterative reconstruction have been investigated. However, for dual‐source CT with flying focal spot (DS‐FFS CT), a statistical iterative reconstruction that accurately models the scanner geometry and acquisition physics remains unknown to researchers. Therefore, our purpose is to present a novel physics‐based iterative reconstruction method for DS‐FFS CT and assess its image quality. Methods Our algorithm uses precise physics models to reconstruct from the native cone‐beam geometry and interleaved dual‐source helical trajectory of a DS‐FFS CT. To do so, we construct a noise physics model to represent data acquisition noise and a prior image model to represent image noise and texture. In addition, we design forward system models to compute the locations of deflected focal spots, the dimension, and sensitivity of voxels and detector units, as well as the length of intersection between x‐rays and voxels. The forward system models further represent the coordinated movement between the dual sources by computing their x‐ray coverage gaps and overlaps at an arbitrary helical pitch. With the above models, we reconstruct images by an advanced Consensus Equilibrium (CE) numerical method to compute the maximum a posteriori estimate to a joint optimization problem that simultaneously fits all models. Results We compared our reconstruction with Siemens ADMIRE, which is the clinical standard hybrid iterative reconstruction (IR) method for DS‐FFS CT, in terms of spatial resolution, noise profile, and image artifacts through both phantoms and clinical scan datasets. Experiments show that our reconstruction has a higher spatial resolution, with a Task‐Based Modulation Transfer Function (MTF task ) consistently higher than the clinical standard hybrid IR. In addition, our reconstruction shows a reduced magnitude of image undersampling artifacts than the clinical standard. Conclusions By modeling a precise geometry and avoiding data rebinning or interpolation, our physics‐based reconstruction achieves a higher spatial resolution and fewer image artifacts with smaller magnitude than the clinical standard hybrid IR.

Wang, Xiao↗

Imaging Asteroid 4 Vesta Using the Framing Camera

The Framing Camera (FC) onboard the Dawn spacecraft serves a dual purpose. Next to its central role as a prime science instrument it is also used for the complex navigation of the ion drive spacecraft. The CCD detector with 1024 by 1024 pixels provides the stability for a multiyear mission and its high requirements of photometric accuracy over the wavelength band from 400 to 1000 nm covered by 7 band-pass filters. Vesta will be observed from 3 orbit stages with image scales of 227, 63, and 17 m/px, respectively. The mapping of Vesta s surface with medium resolution will be only completed during the exit phase when the north pole will be illuminated. A detailed pointing strategy will cover the surface at least twice at similar phase angles to provide stereo views for reconstruction of the topography. During approach the phase function of Vesta was determined over a range of angles not accessible from earth. This is the first step in deriving the photometric function of the surface. Combining the topography based on stereo tie points with the photometry in an iterative procedure will disclose details of the surface morphology at considerably smaller scales than the pixel scale. The 7 color filters are well positioned to provide information on the spectral slope in the visible, the depth of the strong pyroxene absorption band, and their variability over the surface. Cross calibration with the VIR spectrometer that extends into the near IR will provide detailed maps of Vesta s surface mineralogy and physical properties. Georeferencing all these observation will result in a coherent and unique data set. During Dawn s approach and capture FC has already demonstrated its performance. The strong variation observed by the Hubble Space Telescope can now be correlated with surface units and features. We will report on results obtained from images taken during survey mode covering the whole illuminated surface. Vesta is a planet-like differentiated body, but its surface gravity and escape velocity are comparable to those of other asteroids and hence much smaller than those of the inner planets or

Keller, H. Uwe↗

Technology Development for 3-D Wide Swath Imaging Supporting ACE

The National Academy of Sciences Decadal Survey (DS) Aerosol-Cloud-Ecosystems Mission (ACE) aims to advance our ability to observe and predict changes to the Earth's hydrological cycle and energy balance in response to climate forcing, especially those changes associated with the effects of aerosol on clouds and precipitation. ACE is focused on obtaining measurements to reduce the uncertainties in current climate models arising from the lack in understanding of aerosol-cloud interactions. As part of the mission instrument suite, a dual-frequency radar comprised of a fixed-beam 94 gigahertz (W-band) radar and a wide-swath 35 gigahertz (Ka-band) imaging radar has been recommended by the ACE Science Working Group.In our 2010 Instrument Incubator Program project, we've developed a radar architecture that addresses the challenge associated with achieving the measurement objectives through an innovative, shared aperture antenna that allows dual-frequency radar operation while achieving wide-swath (100 kilometers) imaging at Ka-band. The antenna system incorporates 2 key technologies; a) a novel dual-band reflectorreflectarray and b) a Ka-band Active Electronically Scanned Array (AESA) feed module. The dual-band antenna is comprised of a primary cylindrical reflectorreflectarray surface illuminated by a point-focus W-band feed (compatible with a quasi-optical beam waveguide feed, such as that employed on CloudSat); the Ka-band AESA line feed provides wide-swath across-track scanning. The benefits of this shared-aperture approach include significant reductions in ACE satellite payload size, weight, and cost, as compared to a two aperture approach. Four objectives were addressed in our project. The first entailed developing the tools for the analysis and design of reflectarray antennas, assessment of candidate reflectarray elements, and validation using test coupons. The second objective was to develop a full-scale aperture design utilizing the reflectarray surface and to detail specific requirements and trades for the Ka-band AESA line feed. As part of the third objective a subscale antenna, similar to the full-scale aperture design, was developed, integrated, and flown with the Cloud Radar System during the 2014 Integrated Precipitation and Hydrology Experiment. The fourth and ongoing objective entails developing a GaN MMIC (Gallium Nitride Monolithic Microwave Integrated Circuits) power amplifier for use in the Ka-band AESA. An overview of the progress made on this project and a look ahead at the 2013 IIP (Instrument Incubator Program) award selection will be presented.

Antenna↗

An extension of the dual magnetometer method for use on a dual spinning spacecraft

A method of estimating and correcting for the magnetic field of a dual spinning spacecraft has been developed by employing an extension of the dual magnetometer technique of Ness et al. (1971). This new method is useful for those situations in which a magnetometer boom of modest length (7-10 m) is attached to the spinning part of a large spacecraft (800-1000 kg). The purpose of using a dual spinning spacecraft is to accommodate two types of instruments: (1) imaging and similar 'pointed' remote sensing systems on the stationary platform and (2) fields, particles, and other in situ measuring instruments on the spinning portion. Present-day imaging systems are well known to exhibit large magnetic moments, sometimes displaced from the spacecraft center by a significant amount. The new method assumes that the stationary part of the spacecraft possesses a magnetic field which is represented by a combination of a dipole and a quadrupole field.

Lepping, R. P.↗

Data compression techniques for astronomy

The photometric and astrometric accuracy of the Minnesota automated dual-plate scanner is summarized. The relation between magnitude and isophotometric image diameter is linear on Schmidt plates over a large useful range. Results of a study of centroid measurement accuracy and image classification ability of parameters derived from both densitometric and isophotometric scanning techniques are presented. The data analyzed for this purpose are synthesized ideal star and galaxy brightness distributions with appropriate random noise added to simulate plate grain and sky background effects. A preliminary study of image classification using real plates and single isophote data finds that a parameter describing the raggedness of the isophote may be useful in distinguising stars from galaxies.

Landau, R.↗

NGST/XRCF Design and Build Wavescope System Pallet

Based on the successful Wavescope demonstration at MSFC at the end of March, the decision was made by the optical testing team to purchase an upgraded Wavescope from AOA. The MSFC version would include: a higher resolution camera (1000 x 1000 pixels); a higher density lenslet array (150 x 150); updated software; and longer cables (to accommodate the remote operation of the Wavescope optical head which was resident in the Beam Guide Tube). The AOA proposal for the new instrument was received in mid-April, and delivered to MSFC in mid-July. A considerable amount of effort was expended to provide the infrastructure needed for Wavescope operation, and to incorporate it into the overall test system. This was provided by the Wavescope System Pallet (WSP) built by UAH. The WSP is illustrated. Several instruments are incorporated on this pallet. These include the: Wavescope optical head; a PDI wavefront sensor; a point spread function sensor; a Leica light-based distance measuring sensor. In addition there is a single mode fiber point source (fed from a separate source pallet) which serves both as a reference for the Wavescope and as a source point for the test mirror. There is a dual function lens which both collimates the beam from the test image point, and images the test mirror onto the lenslet array. There is a high quality Collimator which can provide a flat input wavefront directly into the Wavescope. There are also various aids such as an alignment laser, an alignment telescope, alignment sticks and apertures. The WSP was delivered to MSFC on 7/28/99. An picture shows the WSP installed in the Guide Tube at the X-Ray Calibration Facility (XRCF).

Geary, Joe↗

Characterization of Three-Stream Jet Flow Fields

Flow-field measurements were conducted on single-, dual- and three-stream jets using two-component and stereo Particle Image Velocimetry (PIV). The flow-field measurements complimented previous acoustic measurements. The exhaust system consisted of externally-plugged, externally-mixed, convergent nozzles. The study used bypass-to-core area ratios equal to 1.0 and 2.5 and tertiary-to-core area ratios equal to 0.6 and 1.0. Axisymmetric and offset tertiary nozzles were investigated for heated and unheated high-subsonic conditions. Centerline velocity decay rates for the single-, dual- and three-stream axisymmetric jets compared well when axial distance was normalized by an equivalent diameter based on the nozzle system total exit area. The tertiary stream had a greater impact on the mean axial velocity for the small bypass-to-core area ratio nozzles than for large bypass-to-core area ratio nozzles. Normalized turbulence intensities were similar for the single-, dual-, and three-stream unheated jets due to the small difference (10%) in the core and bypass velocities for the dual-stream jets and the low tertiary velocity (50% of the core stream) for the three-stream jets. For heated jet conditions where the bypass velocity was 65% of the core velocity, additional regions of high turbulence intensity occurred near the plug tip which were not present for the unheated jets. Offsetting the tertiary stream moved the peak turbulence intensity levels upstream relative to those for all axisymmetric jets investigated.

Noise↗

Characterization of Three-Stream Jet Flow Fields

Flow-field measurements were conducted on single-, dual- and three-stream jets using two-component and stereo Particle Image Velocimetry (PIV). The flow-field measurements complimented previous acoustic measurements. The exhaust system consisted of externally-plugged, externally-mixed, convergent nozzles. The study used bypass-to-core area ratios equal to 1.0 and 2.5 and tertiary-to-core area ratios equal to 0.6 and 1.0. Axisymmetric and offset tertiary nozzles were investigated for heated and unheated high-subsonic conditions. Centerline velocity decay rates for the single-, dual- and three-stream axisymmetric jets compared well when axial distance was normalized by an equivalent diameter based on the nozzle system total exit area. The tertiary stream had a greater impact on the mean axial velocity for the small bypass-to-core area ratio nozzles than for large bypass-to-core area ratio nozzles. Normalized turbulence intensities were similar for the single-, dual-, and three-stream unheated jets due to the small difference (10 percent) in the core and bypass velocities for the dual-stream jets and the low tertiary velocity (50 percent of the core stream) for the three-stream jets. For heated jet conditions where the bypass velocity was 65 percent of the core velocity, additional regions of high turbulence intensity occurred near the plug tip which were not present for the unheated jets. Offsetting the tertiary stream moved the peak turbulence intensity levels upstream relative to those for all axisymmetric jets investigated.

Noise↗

Microcomputed X-Ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives

Microstructural characterization of composite high explosives (HEs) has become increasingly important over the last several decades in association with the development of high fidelity mesoscale modeling and an improved understanding of ignition and detonation processes. HE microstructure influences not only typical material properties (e.g., thermal, mechanical) but also reactive behavior (e.g., shock sensitivity, detonation wave shape). A detailed nondestructive 3D examination of the microstructure has generally been limited to custom-engineered samples or surrogates due to poor contrast between the composite constituents. Highly loaded (>90 wt%) HE composites such as plastic-bonded explosives (PBX) are especially difficult. Here, we present efforts to improve measurement quality by using single and dual-energy microcomputed X-ray tomography and state-of-the-art image processing techniques to study a broad set of HE materials. Some materials, such as PBX 9502, exhibit suitable contrast and resolution for an automatic segmentation of the HE from the polymer binder and the voids. Other composite HEs had varying levels of success in segmentation. Post-processing techniques that used commercially available algorithms to improve the segmentation quality of PBX 9501 as well as zero-density defects such as cracks and voids could be easily segmented for all samples. Aspects of the materials that lend themselves well to this type of measurement are discussed.

36 MATERIALS SCIENCE↗

ML-based Micro-CT SOFC Microstructure Models (from Kent 2026 Microstructural Augmentation paper)

Overview -------------------------- This repository contains datasets from the manuscript **"Enhanced Generalizability to Deep-Learning Quantification of 3D Microstructural Characteristics through Microstructurally Aware Augmentation of Scarce Data"** (*William F. Kent, Rochan Bajpai, Rachel C. Kurchin, William K. Epting, Harry W. Abernathy, Paul A. Salvador. Submitted 2026*). The methods are also described in the dissertation **Data Intensive Analysis of Solid Oxide Cell Microstructures** (*Doctoral dissertation, Carnegie Mellon University, 2025*). The datasets here are trained convolutional neural network (CNN) models for predicting key microstructural properties of solid oxide cell (SOC) electrodes from low-res, 2-channel 3D images, as well as some helpful code. The parameters for input images are provided in the paper. Sample data is provided in the file `Combined_anode_aug_dual_1k_examples` - that particular data was used to train `anode_all_aug.pth` and will work most accurately with that model. Please familiarize yourself with all caveats on accuracy and applicability, as detailed in the associated paper. Usage -------------------------- The basic usage is as follows, assuming `model_fn` is the path to the .pth file, and `X` is 2-channel input image(s) of the proper dimensions (either one image of shape `[2,12,24,24]`, or a batch of N input images of shape `[N,2,12,24,24]`): from CNN_inferencer import load_model_for_inference model = load_model_for_inference(model_fn) y_predicted = model(X) The model object automatically handles input scaling and output de-scaling based on the way the models were trained - in other words, pass in a 2-channel micro-CT image, and it will output microstructural property values in real units. ## Other model object attributes Note that model has useful attributes other than its forward pass model(X). * `model.output_descaler` - returns the output descaler object. Model does the de-scaling when generating inferences, but you may want to re-use this de-scaler on other values to e.g. compare predictions to ground truth from already-scaled training data. * `model.prop_names` - Gives the property names of the predicted y values, in order. Only exists if there's an output scaler as part of the model object, which there will be in the models provided here. ## Usage with sample data Here is a short script to use with the included sample data. from CNN_inferencer import display_predictions, load_model_for_inference, calculate_mape, parity_plot import h5py import numpy as np model_fn = 'anode_all_aug.pth' data_fn = 'Combined_anode_aug_dual_1k_examples.h5' N_samples = 200 figure_outdir = '.' model = load_model_for_inference(model_fn) with h5py.File(data_fn,'r') as f: XX = f['X'] #These are the 2-channel 3D images yy = f['y'] #These are the ground-truth microstructural properties, but they have been scaled for training - need to de-scale below N = XX.shape[0] #How many images total in the input data file #Run inferences on N_samples random samples from XX. #Run in a batch, much more efficient than one at a time. ii = np.random.choice(N,N_samples,replace=False) ii.sort() y_pred = model(XX[ii]) #Get the original/true (but normalized/scaled) values from the training dataset... #Because they were normalized, they are not in real units yet. So let's also de-scale them using model.output_scaler. y_true = model.output_scaler.transform(yy[ii]) #Let's display actual values for just 5 random ones for i in np.random.choice(N_samples,5,replace=False): display_predictions(y_true[i], y_pred[i], model.prop_names) #Make parity plots for each property (ground truth vs predicted values) #Also label each plot with the mean abs. percent error (MAPE) of the predicted values for i,key in enumerate(model.prop_names): mape = calculate_mape(y_true[:,i], y_pred[:,i]) parity_plot(y_true[:,i], y_pred[:,i], figure_outdir, key, extra_title=f' ({mape:.2f}% MAPE)')

3D microstructure↗

High-pressure phase transition in 3-D printed nanolamellar high-entropy alloy by imaging and simulation insights

Abstract We report on the high-resolution imaging and molecular dynamics simulations of a 3D-printed eutectic high-entropy alloy (EHEA) Ni 40 Co 20 Fe 10 Cr 10 Al 18 W 2 consisting of nanolamellar BCC and FCC phases. The direct lattice imaging of 3D-printed samples shows the Kurdjumov–Sachs (K–S) orientation relation {111} FCC parallel to {110} BCC planes in the dual-phase lamellae. Unlike traditional iron and steels, this alloy shows an irreversible BCC-to-FCC phase transformation under high pressures. The nanolamellar morphology is maintained after pressure cycling to 30 GPa, and nano-diffraction studies show both layers to be in the FCC phase. The chemical compositions of the dual-phase lamellae after pressure recovery remain unchanged, suggesting a diffusion-less BCC–FCC transformation in this EHEA. The lattice imaging of the pressure-recovered sample does not show any specific orientation relation between the two resulting FCC phases, indicating that many grain orientations are produced during the BCC–FCC phase transformation. Molecular dynamics simulations on phase transformation in a nanolamellar BCC/FCC in K–S orientation show that phase transformation from BCC to FCC is completed under high pressures, and the FCC phase is retained on decompression aided by the stable interfaces. Our work elucidates the irreversible phase transformation under static compression, providing an understanding of the orientation relationships in 3-D printed EHEA under high pressures.

3-D Printing↗

AFM Microcantilever With a Collocated AlN Sensor-Actuator Pair: Enabling Efficient Q-Control for Dynamic Imaging

This manuscript presents a novel microcantilever with an embedded piezoelectric sensor-actuator pair for dynamic atomic force microscopy (AFM). The transducer pair is constructed from a two-layered AlN stack. Stacking the piezoelectric transducers in this manner leads to a minimal feedthrough from actuation to sense electrode, granting a high dynamic range frequency response for dynamic mode AFM. The cantilever's design allows for dual mode operation at 1 st and 2 nd resonance modes. High resolution tapping mode imaging results are reported, while the cantilever is operated at these modes. A feedback control loop is used to modify quality factor of the 1 st mode of the cantilever, using a positive position feedback (PPF) controller. Here, a faster response time is achieved by reducing the Q-factor, enabling the cantilever to track the topography at a higher scan rate. Results of bimodal AFM imaging are reported, using amplitude changes of the 1 st mode for surface topography, while material properties are encoded in phase changes of the 2 nd mode.

47 OTHER INSTRUMENTATION↗

A compact furnace to support in situ neutron imaging of hydrogen dynamics in yttrium hydride moderators

A compact, nuclear microreactor that utilizes low-enriched uranium fuel is a promising solution to meet U.S. energy demands in nonconventional nuclear markets such as remote and decentralized energy grids. Yttrium hydride (YHx) is a potential moderator material for a microreactor design that reduces the amount of required fuel and provides superior retention of hydrogen at high reactor operating temperatures. Hydrogen diffusion properties in YHx are highly sought after for computer model validation and reactor prototyping. To characterize hydrogen diffusion, a compact dual-zone furnace was developed at Los Alamos National Laboratory and analyzed via neutron imaging at the Los Alamos Neutron Science Center (LANSCE). The goal of these measurements is to assess hydrogen diffusion in YHx samples as a function of applied temperature gradients. Included herein is recent progress in technique and furnace developments as well as initial results from concentration- and temperature-gradient measurements at LANSCE.

Torres, James↗

Design and Functional Validation of a Mechanism for Dual-Spinning CubeSats

The mission of the Micro-sized Microwave Atmospheric Satellite (MicroMAS) is to collect useful atmospheric images using a miniature passive microwave radiometer payload hosted on a low-cost CubeSat platform. In order to collect this data, the microwave radiometer payload must rotate to scan the ground-track perpendicular to the satellite's direction of travel. A custom motor assembly was developed to facilitate the rotation of the payload while allowing the spacecraft bus to remained fixed in the local-vertical, local-horizontal (LVLH) frame for increased pointing accuracy. This paper describes the mechanism used to enable this dual-spinning operation for CubeSats, and the lessons learned during the design, fabrication, integration, and testing phases of the mechanism's development lifecycle.

Peters, Eric↗

Investigation of the Internal Electric Field in Cadmium Zinc Telluride Detectors Using the Pockels Effect and the Analysis of Charge Transients

The Pockels electro-optic effect can be used to investigate the internal electric field in cadmium zinc telluride (CZT) single crystals that are used to fabricate room temperature x and gamma radiation detectors. An agreement is found between the electric field mapping obtained from Pockels effect images and the measurements of charge transients generated by alpha particles. The Pockels effect images of a CZT detector along two mutually perpendicular directions are used to optimize the detector response in a dual anode configuration, a device in which the symmetry of the internal electric field with respect to the anode strips is of critical importance. The Pockels effect is also used to map the electric field in a CZT detector with dual anodes and an attempt is made to find a correlation with the simulated electric potential in such detectors. Finally, the stress-induced birefringence effects seen in the Pockels images are presented and discussed.

Groza, Michael↗

Covalent Surface Modification Effects on Single‐Walled Carbon Nanotubes for Targeted Sensing and Optical Imaging

Abstract Optical nanoscale technologies often implement covalent or noncovalent strategies for the modification of nanoparticles, whereby both functionalizations are leveraged for multimodal applications but can affect the intrinsic fluorescence of nanoparticles. Specifically, single‐walled carbon nanotubes (SWCNTs) can enable real‐time imaging and cellular delivery; however, the introduction of covalent SWCNT sidewall functionalizations often attenuates SWCNT fluorescence. Recent advances in SWCNT covalent functionalization chemistries preserve the SWCNT's pristine graphitic lattice and intrinsic fluorescence, and here, such covalently functionalized SWCNTs maintain intrinsic fluorescence‐based molecular recognition of neurotransmitter and protein analytes. The covalently modified SWCNT nanosensor preserves its fluorescence response towards its analyte for certain nanosensors, presumably dependent on the intermolecular interactions between SWCNTs or the steric hindrance introduced by the covalent functionalization that hinders noncovalent interactions with the SWCNT surface. These SWCNT nanosensors are further functionalized via their covalent handles with a targeting ligand, biotin, to self‐assemble on passivated microscopy slides, and these dual‐functionalized SWCNT materials are explored for future use in multiplexed sensing and imaging applications.

Chio, Linda↗

Compositional and textural information from the dual inversion of visible, near and thermal infrared remotely sensed data

A technique is presented that allows extraction of compositional and textural information from visible, near and thermal infrared remotely sensed data. Using a library of both emissivity and reflectance spectra, endmember abundances and endmember thermal inertias are extracted from AVIRIS (Airborne Visible and Infrared Imaging Spectrometer) and TIMS (Thermal Infrared Mapping Spectrometer) data over Lunar Crater Volcanic Field, Nevada, using a dual inversion. The inversion technique is motivated by upcoming Mars Observer data and the need for separation of composition and texture parameters from sub pixel mixtures of bedrock and dust. The model employed offers the opportunity to extract compositional and textural information for a variety of endmembers within a given pixel. Geologic inferences concerning grain size, abundance, and source of endmembers can be made directly from the inverted data. These parameters are of direct relevance to Mars exploration, both for Mars Observer and for follow-on missions.

Brackett, Robert A.↗