Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid

The development of a wholly superconducting turboelectric distributed propulsion system presents unique opportunities for the aerospace industry. However, this transition from normally conducting systems to superconducting systems significantly increases the equipment complexity necessary to manage the electrical power systems. Due to the low technology readiness level (TRL) nature of all components and systems, current Turboelectric Distributed Propulsion (TeDP) technology developments are driven by an ambiguous set of system-level electrical integration standards for an airborne microgrid system (Figure 1). While multiple decades' worth of advancements are still required for concept realization, current system-level studies are necessary to focus the technology development, target specific technological shortcomings, and enable accurate prediction of concept feasibility and viability. An understanding of the performance sensitivity to operating voltages and an early definition of advantageous voltage regulation standards for unconventional airborne microgrids will allow for more accurate targeting of technology development. Propulsive power-rated microgrid systems necessitate the introduction of new aircraft distribution system voltage standards. All protection, distribution, control, power conversion, generation, and cryocooling equipment are affected by voltage regulation standards. Information on the desired operating voltage and voltage regulation is required to determine nominal and maximum currents for sizing distribution and fault isolation equipment, developing machine topologies and machine controls, and the physical attributes of all component shielding and insulation. Voltage impacts many components and system performance.

electric faults↗

A Hybrid Data-Driven and Model-Based Anomaly Detection Scheme for DER Operation

This paper proposes a hybrid data and model-based anomaly detection scheme to secure the operation of distributed energy resources (DERs) in distribution grids. Data-driven autoencoders are set up at the edge device level and they use local DER operational data as inputs. The abnormal statuses are detected by analyzing reconstruction errors. In parallel, modelbased state estimation (SE) is set up at the central level and it uses system-wide models and measurements as data inputs. The anomalies are identified by analyzing measurement residuals. The hybrid scheme preserves the benefits of both data-driven and model-based analyses and thus improves the robustness and the accuracy of anomaly detection. Numerical tests based on the model of a real distribution feeder in Southern California highlight the proposed scheme's effectiveness and benefits.

anomaly detection↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) – Performance Characterization

Design and performance of a digital signal processing platform for enhancing off-the-shelf voltage and current sensors are presented. The platform was developed for enabling advanced distribution grid applications with existing low-cost sensors. This digital sensor system leverages a variety of off-the-shelf voltage and current sensing technologies, analog-to-digital conversion, and sensor correction algorithms to yield more accurate and reliable digital measurements that support a multitude of applications and use cases. Sample performance and accuracy results are provided, including measurements at power frequency and higher harmonics. The system extends the native performance of the medium voltage sensors used in the system, for example, broadening measurement bandwidth beyond a few kHz, appropriate for measuring switching surges and harmonics on medium voltage distribution systems. The digital sensor system is installed and characterized in the field with a high-bandwidth optical calibration system to determine site-dependent calibration and performance issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decentralized Distribution System Restoration with Grid-Forming/Following Inverter-Based Resources

The high penetration of distributed energy resources (DERs) in active distribution systems has posed challenges to the centralized distribution system restoration (DSR) strategies in current practice. On the other hand, the advancement in smart inverter technologies enables the bottom-up restoration capability. This paper is motivated to develop a 3-layered hierarchical framework for decentralized DSR, based on the grid-forming (GFM) and grid-following (GFL) grid-edge inverters. The first layer presents the tertiary control, which determines the load pickup schedule and generation dispatch of DERs, using the alternating direction method of the multipliers algorithm. The second layer consists of two control functions: GFM control, which regulates voltage and frequency, establishing a stable grid for GFL inverters to follow; and GFL control, which regulates the real and reactive power. In the third layer, the primary control is proposed to regulate the inverter voltage and current, which is developed based on the virtual oscillator control (VOC). Furthermore, the developed framework is tested in the modified IEEE 13-node test feeder. Two scenarios of grid-connected and islanded operating modes are designed, and simulation results demonstrate the effectiveness of decentralized DSR strategies for controlling grid-edge inverters to enhance the distribution system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of TRMM Satellite Rainfall Products Over Oklahoma for a Three Year Period (1998-2000)

This study evaluates the level 2 and level 3 rainfall products from the Tropical Rainfall Measuring Mission gridded distribution of 118 high resolution tipping buckets from the Oklahoma Mesonet. The Tropical Rainfall Measuring Mission, a joint satellite mission between NASA and the National Space Development Agency (NASDA) of Japan, was designed to estimate global precipitation between 40 S and 40 N latitude. The TRMM satellite, consisting of two main precipitation sensors, a passive microwave (TMI) and precipitation radar (PR) sensors, was launched in 1997. Although the great advantage of TRMM has been its ability to sample precipitation globally over the tropical oceans in places where ground sensors do not exist, regional points over land still offer the best opportunity for validating these rain estimates. For this study, the gauge data was gridded at I x I degree resolution between 34 and 36 N and -95 and -100 W. The location of Oklahoma is somewhat unique, in that, it is located near the turning point for the satellite. This study investigates effects of temporal sampling on the satellite measurements and the resulting rainfall bias observed between space and ground based sensors. The first part of the study analyzes the monthly rainfall statistics of the 3AI2 (TMI), the 3A25 (PR) and the 31142 (combined sensors) with the rain gauges. It uses regression techniques and a computation of the probability density function (PDF) and cumulative probability density function (CDF) for each sensor to evaluate the effects of temporal sampling on the satellite products and the sufficiency of using two overpasses a day to estimate rainfall on a monthly scale. In further probing this issue, the study also looked at the direct coincidence of ground and satellite measurements by comparing instantaneous comparisons obtained from the level 2 orbital track data, e.g. 2A12, 2A25. Lastly, the effects of temporal sampling were further studied by sub-sampling the gauge data only at overpass times. This methodology provides a quantitative way of separately inferring the fraction of bias due to temporal sampling and the rainfall algorithm. In addition to showing the salient effects of temporal sampling, the study also revisits the historical problem of correlating point gauge estimates with area estimates, though, the problem is ameliorated by averaging and gridding the data to the area resolution scale of the satellite.

Fisher, Brad↗

An Information Theoretic Approach to Identify Dominant Voltage Influencers for Unbalanced Distribution Systems

Smart distribution grid with multiple renewable energy sources can experience random voltage fluctuations due to variable generation, which may result in voltage violations. Traditional voltage control algorithms are inadequate to handle fast voltage variations. Therefore, new dynamic control methods are being developed that can significantly benefit from the knowledge of dominant voltage influencer (DVI) nodes. DVI nodes for a particular node of interest refer to nodes that have a relatively high impact on the voltage fluctuations at that node. Conventional power flow-based algorithms to identify DVI nodes are computationally complex, which limits their use in real-time applications. This paper proposes a novel information theoretic voltage influencing score (VIS) that quantifies the voltage influencing capacity of nodes with DERs/active loads in a three phase unbalanced distribution system. VIS is then employed to rank the nodes and identify the DVI set. VIS is derived analytically in a computationally efficient manner and its efficacy to identify DVI nodes is validated using the IEEE 37-node test system. It is shown through experiments that KL divergence and Bhattacharyya distance are effective indicators of DVI nodes with an identifying accuracy of more than 90%. Additionally, the computation burden is also reduced by an order of 5, thus providing the foundation for efficient voltage control.

42 ENGINEERING↗

Islanding Detection in Rural Distribution Systems

This paper summarizes the literature on detection of islanding resulting from distributed generating capabilities in a power distribution system, with emphasis on the rural distribution systems. It is important to understand the legacy technology and equipment in the rural distribution electrical environment due to the growth of power electronics and the potential for adding the new generations of intelligent sensors. The survey identified four areas needing further research: 1. Robustness in the presence of distribution grid disturbances; 2. the future role of artificial intelligence in the islanding application; 3. more realistic standard tests for the emerging electrical environment; 4. smarter sensors. In addition, this paper presents a synchro-phasor-based islanding detection approach based on a wireless sensor network developed by the University of Texas at Austin. Initial test results in a control hardware-in-the-loop (CHIL) simulation environment suggest the effectiveness of the developed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Regulation Through Legislation: A Cautionary Tale for Legislators, Regulators, Stakeholders, and Utilities

State legislatures in the U.S. are becoming increasingly involved in utility regulation. While state utility legislation can expand regulator authority, for example in the case of renewable energy or energy efficiency standard administration, it can also reduce it. Given the challenging nature of for-profit monopoly regulation, state utility legislation often reduces regulator authority unintentionally. This editorial begins with an examination of the outcomes of state legislation related to baseload generation in the U.S. and the resulting impacts to customers, shareholders, and state economies. The record indicates that utility regulation through state legislation has caused significant economic harm, generally by encouraging for-profit utilities to make riskier investments. A description of more recent state legislation involving distribution grids is presented, along with evidence that increases in grid investment encouraged by state legislation has not improved the reliability of U.S. for-profit utilities. The authors claim that features common to state utility legislation, particularly the requirement that utilities provide investment plans to regulators in advance, practically eliminates cost disallowance risk. This, in turn, reduces regulator authority despite legislative provisions intended to protect consumers. The authors hypothesize that the practical elimination of cost disallowance risk, combined with information and expertise asymmetry among regulators and stakeholders, encourages for-profit monopoly utilities to make grid investments that are not cost effective. The editorial concludes that legislators should avoid utility regulation through legislation, thereby preserving regulator authority, whenever possible. The authors also present their fifth annual Customer Value Ranking of U.S. investor-owned electric utilities. The ranking represents a comparison of the benefits utilities deliver to customers (measured by reliability performance and customer satisfaction) to the costs customers pay (measured by O&M and capital spending per customer).

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Highly Available Nuclear Power for Mission-Critical Applications

Some energy consumers require power on an anytime, all-year-round basis with a high level of certainty, including defense installations, isolated communities, and some industrial processes. For these customers, interruptions in electricity or heat can mean substantial financial loss or even loss of life. In the absence of grid-scale energy storage, a high level of power availability can be accomplished only through the robustness and redundancy of power generators. The NuScale small modular reactor design is well suited to provide highly available power because of several features related to both the nuclear steam supply system and the overall plant design. In analogy to Redundant Array of Independent Disks (RAID) systems used to provide highly reliable data storage, a NuScale plant can assure sustained power generation by virtue of its Redundant Array of Integral Reactors (RAIR).This paper describes the NuScale RAIR plant features and summarizes the results of a rigorous analysis of RAIR availability as a function of power or, conversely, the RAIR plant output power as a function of power availability. The analysis utilized the Matrix Laboratory code (MATLAB) and included probability distributions for the frequency and duration of module outages due to planned and unplanned events. Further, the study evaluated the impact of implementing turbine bypass rather than module shutdown and using one or more modules to supply house loads in the case of loss of off-site power (LOOP). Availability results are presented for a 12-module RAIR plant with and without turbine bypass enabled during a LOOP and for different possible connections to the off-site power distribution grid and dedicated service loads. Results indicate that a very high level of availability can be achieved at relatively high power output levels, regardless of turbine bypass and dedicated load connection, compared to the operating fleet.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Extracting Resilience Metrics From Distribution Utility Data Using Outage and Restore Process Statistics

Resilience curves track the accumulation and restoration of outages during an event on an electric distribution grid. We show that a resilience curve generated from utility data can always be decomposed into an outage process and a restore process and that these processes generally overlap in time. We use many events in real utility data to characterize the statistics of these processes, and derive formulas based on these statistics for resilience metrics such as restore duration, customer hours not served, and outage and restore rates. The formulas express the mean value of these metrics as a function of the number of outages in the event. We also give a formula for the variability of restore duration, which allows us to predict a maximum restore duration with 95% confidence. Overall, we give a simple and general way to decompose resilience curves into outage and restore processes and then show how to use these processes to extract resilience metrics from standard distribution system data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

A Hybrid Optimization and Deep Learning Algorithm for Cyber-Resilient DER Control

With the proliferation of distributed energy resources (DERs) in the distribution grid, it is a challenge to effectively control a large number of DERs resilient to the communication and security disruptions, as well as to provide the online grid services, such as voltage regulation and virtual power plant (VPP) dispatch. To this end, a hybrid feedback-based optimization algorithm along with deep learning forecasting technique is proposed to specifically address the cyber-related issues. The online decentralized feedback-based DER optimization control requires timely, accurate voltage measurement from the grid. However, in practice such information may not be received by the control center or even be corrupted. Therefore, the long short-term memory (LSTM) deep learning algorithm is employed to forecast delayed/missed/attacked messages with high accuracy. The IEEE 37-node feeder with high penetration of PV systems is used to validate the efficiency of the proposed hybrid algorithm. The results show that 1) the LSTM-forecasted lost voltage can effectively improve the performance of the DER control algorithm in the practical cyber-physical architecture; and 2) the LSTM forecasting strategy outperforms other strategies of using previous message and skipping dual parameter update.

cyber-resilient algorithm↗

GA-Based Voltage Optimization of Distribution Feeder with High-Penetration of DERs Using Megawatt-Scale Units

In this paper, genetic algorithm (GA)-based voltage optimization of a modified IEEE-34 node distribution feeder with high penetration of distributed energy resources (DERs) is proposed using two megawatt-scale reactive power sources. Traditional voltage support units present in distribution grids are not suitable for DER-rich feeders, while voltage support using small-scale DERs present in the feeder requires considerable communication effort to reach a global solution. In this work, two megawatt-scale units are placed to improve the voltage profile across the IEEE 34-node feeder, which has been modified to include several PV units and an energy storage unit. The megawatt-scale units are optimized using GA for fast and accurate operation. The performance of the proposed scheme is verified using simulation results with a multi-platform setup where the modified IEEE-34 node feeder is modeled in OpenDSS while the GA optimization scheme is programmed in MATLAB.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Background Information on the Power Quality Requirements in IEEE Std 1547-2018

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547-2018, Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces, was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, and energy storage systems with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects that are important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concepts and requires appropriate information to calculate relevant settings and configurations. This document provides informative material on the requirements related to electrical power quality in IEEE Std 1547-2018, with the intent to equip the reader with basic knowledge and background information to improve understanding and use of the requirements specified.

14 SOLAR ENERGY↗

Minnesota Solar Pathways: Illuminating Pathways to 10% Solar (Final Technical Report)

The Minnesota Solar Pathways project, funded in part by the Department of Energy’s Solar Energy Technologies Office, was a three-year project designed to explore least-risk, best-value strategies for meeting the State of Minnesota’s solar goals. As part of this aim, the Pathways Team modeled renewable generation costs, examined ways to streamline interconnection, and evaluated technologies that can increase solar hosting capacity on the distribution grid. Midway through the project period, the Pathways Team expanded the scope of study using the same modeling framework from the Minnesota Solar Potential Analysis to estimate and compare generation costs for high renewables penetration scenarios across the Midcontinent Independent System Operator (MISO) region. The analysis concludes that it can be cheaper to overbuild solar + wind and curtail surplus than to store all generation. In addition, the analysis of individual MISO subregions compared with the whole region highlights the opportunities of enabling market potential compared with impact of ongoing transmission constraints. Beyond the analysis of future scenarios, the partnerships initiated and supported through this project underscored the ongoing need for work with stakeholders to address key issues, particularly around siting, and leverage symbiotic strategies to meet state goals.

14 SOLAR ENERGY↗

Constraints on OPF Surrogates for Learning Stable Local Volt/Var Controllers

We consider the problem of learning local Volt/Var controllers in distribution grids (DGs). Our approach starts from learning separable surrogates that take both local voltages and reactive powers as arguments and predict the reactive power setpoints that approximate optimal power flow (OPF) solutions. We propose an incremental control algorithm and identify two different sets of slope conditions on the local surrogates such that the network is collectively steered toward desired configurations asymptotically. Our results reveal the trade-offs between each set of conditions, with coupled voltage-power slope constraints allowing an arbitrary shape of surrogate functions but risking limitations on exploiting generation capabilities, and reactive power slope constraints taking full advantage of generation capabilities but constraining the shape of surrogate functions. AC power flow simulations on the IEEE 37-bus feeder illustrate their guaranteed stability properties and respective advantages in two DG scenarios.

asymptotic stability↗

An Overview of Issues Related to IEEE Std 1547-2018 Requirements Regarding Voltage and Reactive Power Control

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547 Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces (IEEE Std 1547-2018) was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concept and requires the appropriate information required to calculate relevant settings and configurations. Various stakeholders have different roles in implementing the standard, and portions of the standard are directed toward a specific audience who must possess specialized information and technical training to use and apply the requirements. This document aims to (1) summarize a specific portion of the standard as concisely as possible and (2) provide the reader with introductory knowledge and information to support the utilization of the requirements.

14 SOLAR ENERGY↗