Melt Blending: A Tool to Simplify Plastic Scintillator Synthesis

Plastic scintillators are widely used as radiation detection media in homeland security and nuclear physics applications. Their attributes include low cost, scalability to large detector volumes, and additive compounding to enable additional material and detection features, such as pulse shape discrimination (PSD), gamma-ray spectroscopy, aging resistance, and coincidence timing. However, traditional chemically cured plastic scintillators (CCS) require long reaction times, and hazardous wet chemical procedures performed by specially trained personnel, and can leave residual monomer, resulting in deleterious optical and material properties. Here, we synthesize melt blended scintillators (MBSs) in 2.5 days using easily accessible solid-state compounding of commercially-available poly(styrene) with 30–60 wt% fluorene-based compound “P2” to create monolithic detectors with < 100 ppm residual monomer, in several form factors. Further, the best scintillation performance was recorded for 60 wt% P2 in Styron 665, including gamma-ray light yield 139% of EJ- 200 commercial scintillator and PSD figure of merit (FOM) value of 2.65 at 478 keVee, approaching P2 organic glass scintillator (OGS). The capability of MBS to generate fog-resistant scintillators and poly(methyl methacrylate) (PMMA)-based scintillators for use in challenging environments is also demonstrated.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Elliptically-Contoured Tensor-variate Distributions with Application to Image Learning

Statistical analysis of tensor-valued data has largely used the tensor-variate normal (TVN) distribution that may be inadequate for data arising from distributions with heavier or lighter tails. We study a general family of elliptically contoured (EC) TV distributions and derive its characterizations, moments, marginal, and conditional distributions. We describe procedures for maximum likelihood estimation from data that are (1) uncorrelated draws from an EC distribution, (2) from a scale mixture of the TVN distribution, and (3) from an underlying but unknown EC distribution, for which we extend Tyler’s robust estimator. A detailed simulation study highlights the benefits of choosing an EC distribution over the TVN for heavier-tailed data. We develop TV classification rules using discriminant analysis and EC errors and show that they better predict cats and dogs from images in the Animal Faces-HQ dataset than the TVN-based rules. A novel tensor-on-tensor regression and TV analysis of variance (TANOVA) framework under EC errors is also demonstrated to better characterize gender, age, and ethnic origin than the usual TVN-based TANOVA in the celebrated labeled faces of the wild dataset.

97 MATHEMATICS AND COMPUTING↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural Polymorphism of Chitin and Chitosan in Fungal Cell Walls From Solid-State NMR and Principal Component Analysis

Chitin is a major carbohydrate component of the fungal cell wall and a promising target for novel antifungal agents. However, it is technically challenging to characterize the structure of this polymer in native cell walls. Here, we recorded and compared 13 C chemical shifts of chitin using isotopically enriched cells of six Aspergillus, Rhizopus, and Candida strains, with data interpretation assisted by principal component analysis (PCA) and linear discriminant analysis (LDA) methods. The structure of chitin is found to be intrinsically heterogeneous, with peak multiplicity detected in each sample and distinct fingerprints observed across fungal species. Fungal chitin exhibits partial similarity to the model structures of α- and γ-allomorphs; therefore, chitin structure is not significantly affected by interactions with other cell wall components. Addition of antifungal drugs and salts did not significantly perturb the chemical shifts, revealing the structural resistance of chitin to external stress. In addition, the structure of the deacetylated form, chitosan, was found to resemble a relaxed two-fold helix conformation. This study provides high-resolution information on the structure of chitin and chitosan in their cellular contexts. The method is applicable to the analysis of other complex carbohydrates and polymer composites.

59 BASIC BIOLOGICAL SCIENCES↗

Utilizing a Database of Simulated Geometric Albedo Spectra for Photometric Characterization of Rocky Exoplanet Atmospheres

In anticipation of future flagship missions focused on the goal of achieving direct imaging of rocky exoplanets, we have developed a database of models to help the community examine the potential spectral characteristics of a broad range of rocky planet atmospheres. Using the publicly available Planetary Spectrum Generator, we have computed a grid of 141,600 rocky exoplanet geometric albedo spectra across a seven-dimensional parameter space. Using this grid, we have performed a color–color analysis seeking to identify the most useful near-UV and red or near-infrared photometric follow-up channels to combine with a green-optical (discovery) spectral channel. We found that a combination of filters at 0.4, 0.58, and ∼0.8 μm were able to distinguish between atmospheres with moderate-to-high concentrations of four different dominant absorbing constituents, given at least 10 hr of observation on a star at 10 parsec with a 15 m class space telescope; however, more moderate abundances similar to those of solar system rocky bodies would be more challenging to detect. We recommend that future missions seeking to characterize directly imaged rocky exoplanets by colors alone further consider multiband photometry as a first discriminator for planetary characteristics.

79 ASTRONOMY AND ASTROPHYSICS↗

Criticality Consideration for Geologic Disposal of DOE-Owned Spent Nuclear Fuels - 20255

Decisions must be made relative to packaging spent nuclear fuel (SNF) for storage, transportation, and eventual disposal. This paper evaluates potential criticality-related loading and packaging considerations for Department of Energy (DOE)-owned SNF that could be impacted favorably or unfavorably by disposal uncertainties and proposes approaches to minimize such impacts. Using Al-Based SNF as an example and drawing on analyses performed in support of the Yucca Mountain Repository License Application (LA), this paper explores the role of natural barriers, engineered barriers, and waste form characteristics relative to reducing the potential for postclosure criticality. Several parameters important to postclosure criticality are considered in order to determine which are useful discriminators to support packaging decisions. Using these parameters, a qualitative assessment is performed relative to three options for managing DOE-owned SNFs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tailored Graphene Micropatterns by Wafer-Scale Direct Transfer for Flexible Chemical Sensor Platform

2D materials, such as graphene, exhibit great potential as functional materials for numerous novel applications due to their excellent properties. The grafting of conventional micropatterning techniques on new types of electronic devices is required to fully utilize the unique nature of graphene. However, the conventional lithography and polymer-supported transfer methods often induce the contamination and damage of the graphene surface due to polymer residues and harsh wet-transfer conditions. In this work, a novel strategy to obtain micropatterned graphene on polymer substrates using a direct curing process is demonstrated. Employing this method, entirely flexible, transparent, well-defined self-activated graphene sensor arrays, capable of gas discrimination without external heating, are fabricated on 4 in. wafer-scale substrates. Finite element method simulations show the potential of this patterning technique to maximize the performance of the sensor devices when the active channels of the 2D material are suspended and nanoscaled. This study contributes considerably to the development of flexible functional electronic devices based on 2D materials.

2D materials, Graphene, Microscale patterning, Che↗

Molecularly Imprinted Polymer Sensor Empowered by Bound States in the Continuum for Selective Trace-Detection of TGF-beta

The integration of advanced materials and photonic nanostructures can lead to enhanced biodetection capabilities, crucial in clinical scenarios and point-of-care diagnostics, where simplified strategies are essential. Herein, a molecularly imprinted polymer (MIP) photonic nanostructure is demonstrated, which selectively binding to transforming growth factor-beta (TGF-β), in which the sensing transduction is enhanced by bound states in the continuum (BICs). The MIP operating as a synthetic antibody matrix and coupled with BIC resonance, enhances the optical response to TGF-β at imprinted sites, leading to an augmented detection capability, thoroughly evaluated through spectral shift and optical lever analogue readout. The validation underscores the MIP-BIC sensor capability to detect TGF-β in spiked saliva, achieving a limit of detection of 10 fM and a resolution of 0.5 pM at physiological concentrations, with a precision of two orders of magnitude above discrimination threshold in patients. The MIP tailored selectivity is highlighted by an imprinting factor of 52, showcasing the sensor resistance to interference from other analytes. The MIP-BIC sensor architecture streamlines the detection process eliminating the need for complex sandwich immunoassays and demonstrates the potential for high-precision quantification. This positions the system as a robust tool for biomarker detection, especially in real-world diagnostic scenarios.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Spatially Resolved Performance Analysis for Perovskite Solar Cells

This review explores the current state of the art in spatially resolved characterization of mixed-halide perovskite solar cells. As the size of perovskite cells and modules continues to grow, quantification of the spatial distribution of key cell parameters will become increasingly valuable in predicting ultimate cell-level performance and tracking process homogeneity. Here, both high resolution microscopic approaches using scanning techniques and camera-based methods for full-area cell and/or module analysis are discussed. The value of this local data in predicting performance losses at the cell level is particularly emphasized. Measurable physical parameters sensitive to losses of voltage, current, fill factor, and efficiency are discussed together with selected experimental results. It is demonstrated that a combination of spatially resolved cell parameter mapping/imaging can be used to quantitatively discriminate various loss contributions at high resolution. The impact and control of inhomogeneities become particularly important when upscaling from small devices to large formats compatible with industrial mass production.

14 SOLAR ENERGY↗

Deterministic symbolic regression with derivative information: General methodology and application to equations of state

Symbolic regression methods simultaneously determine the model functional form and the regression parameter values by generating expression trees. Symbolic regression can capture the complexity of real–world phenomena but the use of deterministic optimization for symbolic regression has been limited due to the complexity of the search space of existing formulations. Herein we present a novel deterministic mixed–integer nonlinear programming formulation for symbolic regression that incorporates derivative constraints through auxiliary expression trees. By applying the chain rule to mathematical operations, binary expression trees are capable of representing the calculation of first and second derivatives. We apply this formulation to illustrative examples using derivative information to show increased model discrimination capability. In addition, we perform a case study of a thermodynamic equation of state to gain insight on valid functional forms with thermodynamics–based constraints on the first and second derivatives.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multimodal Imaging of Autofluorescent Sites Reveals Varied Chemical Speciation in SSZ-13 Crystals

Here, a multimodal imaging study of chabazite is used to show the distribution of and discriminate between different emissive deposits arising as a result of the detemplation process. 3D confocal imaging, fluorescence lifetime imaging, spectral imaging, and Raman mapping are used to show three different types of emissive behaviours each characterised by different spatial distributions, trends in lifetime, spectral signals, and Raman signatures. A notable difference is seen in the morphology of agglomerated surface deposits and larger subsurface deposits, which experience lifetime augmentation due to spatial confinement. The distribution of organic residue throughout the crystal volume is comparable to XRF mapping that shows Si enrichment on the outer edges and higher Al content through the centre, demonstrating that a fluorescence-based technique can also be used to indirectly comment on the compositional chemistry of the inorganic framework.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature‐Programmed Separation of Hexane Isomers by a Porous Calcium Chloranilate Metal‐Organic Framework

Abstract The full separation of alkane isomers as a function of different degrees of branching remains a daunting challenge due to its stringent requirement with respect to pore dimensions of the adsorbents. In this work, we report a novel microporous coordination network built on calcium (II) and chloranilate. The compound has a flexible framework and exhibits temperature‐dependent adsorption behavior toward hexane isomers. At 30 °C, it accommodates substantial amounts of linear and monobranched hexanes but fully excludes their dibranched isomer, and at elevated temperatures such as 150 °C, it acts as a splitter for linear and branched alkanes. Its capability of efficient discrimination of hexane isomers as a function of branching is verified by experimental breakthrough measurements. Ab initio calculations have uncovered the underlying selective size‐exclusion separation mechanism.

Lin, Yuhan↗

Multimodal Imaging of Autofluorescent Sites Reveals Varied Chemical Speciation in SSZ-13 Crystals

In this report a multimodal imaging study of chabazite is used to analyse emissive deposits. A notable difference is seen in the morphology of agglomerated surface deposits and larger subsurface deposits. Comparison of the distribution of organic residue throughout the crystal volume and XRF mapping is demonstrating that a fluorescence-based technique can also be used to indirectly comment on the compositional chemistry of the inorganic framework. A multimodal imaging study of chabazite is used to show the distribution of and discriminate between different emissive deposits arising as a result of the detemplation process. Confocal imaging, 3D fluorescence lifetime imaging, 3D multispectral fluorescence imaging, and Raman mapping are used to show three different types of emissive behaviours each characterised by different spatial distributions, trends in lifetime, spectral signals, and Raman signatures. A notable difference is seen in the morphology of agglomerated surface deposits and larger subsurface deposits, which experience lifetime augmentation due to spatial confinement. The distribution of organic residue throughout the crystal volume is comparable to XRF mapping that shows Si enrichment on the outer edges and higher Al content through the centre, demonstrating that a fluorescence-based technique can also be used to indirectly comment on the compositional chemistry of the inorganic framework.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature–Programmed Separation of Hexane Isomers by a Porous Calcium Chloranilate Metal–Organic Framework

The full separation of alkane isomers as a function of different degrees of branching remains a daunting challenge due to its stringent requirement with respect to pore dimensions of the adsorbents. In this work, we report a novel microporous coordination network built on calcium (II) and chloranilate. The compound has a flexible framework and exhibits temperature-dependent adsorption behavior toward hexane isomers. At 30 °C, it accommodates substantial amounts of linear and monobranched hexanes but fully excludes their dibranched isomer, and at elevated temperatures such as 150 °C, it acts as a splitter for linear and branched alkanes. Its capability of efficient discrimination of hexane isomers as a function of branching is verified by experimental breakthrough measurements. Furthermore, ab initio calculations have uncovered the underlying selective size-exclusion separation mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linker Vacancy Engineering of a Robust ftw–type Zr–MOF for Hexane Isomers Separation

Discrimination of physically similar molecules by porous solids represents an important yet challenging task in industrially relevant chemical separations. Precisely controlled pore dimension and/or tailored pore surface functionality are crucial to achieve high-efficiency separation. Metal-organic frameworks (MOFs) are promising candidates for these challenging separations in light of their structural diversity as well as highly adjustable pore dimension/functionality. We report here a microporous, ftw-type Zr-based MOF structure, HIAM-410 (HIAM=Hoffmann Institute of Advanced Materials), built on hexanuclear Zr 6 cluster and pyrene-1,3,6,8-tetracarboxylate (ptc 4– ). Its crystallographic structure has been determined using continuous rotation electron diffraction (cRED) technique combined with Rietveld refinement against powder X-ray diffraction data, aided by low-dose high-resolution transmission electron microscopy (HRTEM) imaging. The compound features exceptional framework stability that is comparable to the prototype MOF UiO-66. Interestingly, the linker vacancies in the pristine MOF structure could be partially restored by post-synthetic linker insertion. Its separation capability of hexane isomers is enhanced substantially upon the linker vacancy engineering. As a result, the restored structure exhibits efficient splitting of monobranched and dibranched hexane isomers at both room temperature and industrially relevant temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Super resolution for root imaging

Premise High‐resolution cameras are very helpful for plant phenotyping as their images enable tasks such as target vs. background discrimination and the measurement and analysis of fine above‐ground plant attributes. However, the acquisition of high‐resolution images of plant roots is more challenging than above‐ground data collection. An effective super‐resolution (SR) algorithm is therefore needed for overcoming the resolution limitations of sensors, reducing storage space requirements, and boosting the performance of subsequent analyses. Methods We propose an SR framework for enhancing images of plant roots using convolutional neural networks. We compare three alternatives for training the SR model: (i) training with non‐plant‐root images, (ii) training with plant‐root images, and (iii) pretraining the model with non‐plant‐root images and fine‐tuning with plant‐root images. The architectures of the SR models were based on two state‐of‐the‐art deep learning approaches: a fast SR convolutional neural network and an SR generative adversarial network. Results In our experiments, we observed that the SR models improved the quality of low‐resolution images of plant roots in an unseen data set in terms of the signal‐to‐noise ratio. We used a collection of publicly available data sets to demonstrate that the SR models outperform the basic bicubic interpolation, even when trained with non‐root data sets. Discussion The incorporation of a deep learning–based SR model in the imaging process enhances the quality of low‐resolution images of plant roots. We demonstrate that SR preprocessing boosts the performance of a machine learning system trained to separate plant roots from their background. Our segmentation experiments also show that high performance on this task can be achieved independently of the signal‐to‐noise ratio. We therefore conclude that the quality of the image enhancement depends on the desired application.

Ruiz‐Munoz, Jose F.↗

A nomogram for prediction of stage III/IV gastric cancer outcome after surgery: A multicenter population‐based study

Abstract Most patients with gastric cancer (GC) are first diagnosed at stage III‐IV and surgery resection remains the primary therapeutic modality for these patients. However, clinical staging used for prediction of those patients provides limited information. We collected clinicopathological data and disease‐progression information from 508 patients with stage III‐IV GC at three Chinese hospitals and 1298 patients from the Surveillance, Epidemiology, and End Results database. Based on the stepwise multivariate regression model, we constructed a novel nomogram to predict overall survival (OS). The performance of discrimination for this model was measured using Harrell's concordance index (C‐index) and receiver‐operating characteristic curve (ROC), and was validated using calibration plots. Multivariate Cox regression analyses showed that tumor size, age at diagnosis, N stage, tumor grade, and distant metastases were outstanding independent prognostic factors of stage III‐IV GC. We developed a nomogram based on these five prognostic predictors. In the training set, the C‐index of the nomogram was 0.645 (95% CI: 0.611‐0.679), which was higher than that of the American Joint Committee on Cancer TNM system alone (sixth TNM: 0.544; seventh TNM: 0.575; eighth TNM: 0.568). Similar results were observed in validation cohort. Moreover, calibration blots demonstrated good consistency between the actual and predicted OS probabilities. According to the nomogram, GC individuals could be classified into three groups (low‐, middle‐, and high‐risk) ( P < .001). Our nomogram complements the current staging system for prediction of individual prognosis with stage III‐IV GC, and may be helpful for making individualized treatment decisions.