Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Thermographic monitoring of materials under simulated reentry conditions

Thermography can be used to measure surface temperature gradients graphically, and can be used under conditions where the direct measurement of temperature at all desired points, using thermocouples or resistance temperature detectors (RTDs), is either difficult or impossible. The use of thermographic monitoring during a series of arc-jet tests is described. Described in this work are the issues that influence interpretation of the thermographic measurements under these conditions, including the calculation of effective emittance and window transmittance from the spectral properties of the materials in order to calculate the temperature distribution of a surface directly from the measured radiance. Comparison of the surface temperatures measured using thermocouples and the temperatures derived from thermographic measurements show good agreement. The data gathered will be used to evaluate important test parameters such as the heating distribution across the surface of a heat shield test model and at steps on the model surface.

White, Susan M.↗

Assimilation of TES Water Vapor Observations

The Thermal Emission Spectrometer (TES) on the Mars Global Surveyor has made extensive observations of the Martian atmospheric water vapor column since the beginning of its mapping mission in early 1999. The results show broad agreement with the earlier Viking Mars Atmospheric Water Detector (MAWD) results (though column amounts in southern summer are higher, perhaps due to dust obscuration during the Viking mission). General circulation model (GCM) simulations of the annual Martian water cycle also show broad agreement with the TES observations. Details of the simulations depend on cloud and boundary layer parameterizations and on the adsorbing properties of the regolith. In order to make quantitative assessments of this agreement and to obtain observational values for the required physical parameters, a tracer transport data assimilation model has been developed. Model winds are derived from both tracer measurements and retrieved atmospheric temperature structures, providing a useful check of the underlying dynamical core of the GCM. By allowing detailed intercomparison between spacecraft and ground-based observations of Martian water vapor, the model should also contribute significantly to our understanding of the diurnal water cycle.

Houben, Howard↗

Simulation of Energy Response of the ATIC Calorimeter

ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CR particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2001. The ATIC flight collected approximately 25 million events. For reconstruction of primary spectra from spectra of energy deposits measured in the experiment, correlations between kinetic energy of a primary particle E(sub kin) and energy deposit in the calorimeter E(sub d) should be known. For this purpose, simulations of energy response of the calorimeter on energy spectra of different nuclei were done. The simulations were performed by GEANT-3.21 code with QGSM generator for nucleus - nucleus interactions. The incident flux was taken as isotropic in the ATIC aperture. Primary spectra power-law by momentum were used as inputs according to standard models of cosmic ray acceleration. These spectra become power-law by kinetic energy at E(sub kin) higher than approx.20Mc(sup 2), where M is primary nucleus mass. It should be noted that energy deposit spectra measured by ATIC illustrate similar behavior. Distributions of ratio E(sub kin)/E(sub d) are presented for different energy deposits and for a set of primaries. For power-law regions of energy spectra at E(sub d)> or equal to 20Mc(sup 2) the obtained mean value of E(sub kin)/E(sub d) increases from approx.2.4 for protons to approx.3.1 for iron, while rms/ decreases from 50% for protons to about 15% for iron. These values were obtained for the spectral index gamma=1.6

Batkov, K. E.↗

Geostationary Imaging FTS (GIFTS) Data Processing: Measurement Simulation and Compression

GIFTS (Geostationary Imaging Fourier Transform Spectrometer), a forerunner of next generation geostationary satellite weather observing systems, will be built to fly on the NASA EO-3 geostationary orbit mission in 2004 to demonstrate the use of large area detector arrays and readouts. Timely high spatial resolution images and quantitative soundings of clouds, water vapor, temperature, and pollutants of the atmosphere for weather prediction and air quality monitoring will be achieved. GIFTS is novel in terms of providing many scientific returns that traditionally can only be achieved by separate advanced imaging and sounding systems. GIFTS' ability to obtain half-hourly high vertical density wind over the full earth disk is revolutionary. However, these new technologies bring forth many challenges for data transmission, archiving, and geophysical data processing. In this paper, we will focus on the aspect of data volume and downlink issues by conducting a GIFTS data compression experiment. We will discuss the scenario of using principal component analysis as a foundation for atmospheric data retrieval and compression of uncalibrated and un-normalized interferograms. The effects of compression on the degradation of the signal and noise reduction in interferogram and spectral domains will be highlighted. A simulation system developed to model the GIFTS instrument measurements is described in detail.

Huang, Hung-Lung↗

Laser altimetry simulator. Version 3.0: User's guide

A numerical simulator of a pulsed, direct detection laser altimeter has been developed to investigate the performance of space-based laser altimeters operating over surfaces with various height profiles. The simulator calculates the laser's optical intensity waveform as it propagates to and is reflected from the terrain surface and is collected by the receiver telescope. It also calculates the signal and noise waveforms output from the receiver's optical detector and waveform digitizer. Both avalanche photodiode and photomultiplier detectors may be selected. Parameters of the detected signal, including energy, the 50 percent rise-time point, the mean timing point, and the centroid, can be collected into histograms and statistics calculated after a number of laser firings. The laser altimeter can be selected to be fixed over the terrain at any altitude. Alternatively, it can move between laser shots to simulate the terrain profile measured with the laser altimeter.

Abshire, James B.↗

Evaluation of a 256 x 256 Si:As IBC detector array for astronomy

256 x 256-element IBC Si:As arrays have been evaluated for applications in IR astronomy from space-borne platforms. Basic figures of merit were measured at IR flux levels simulating those expected in space-based astronomical observations. Results include dark current less than 20 e(-)/s, G-eta as high as 3.8, eta/beta of 20%, and read noise below 100 rms(e(-)).

Mckelvey, M. E.↗

Dust environment of Comet Halley

Advances in the understanding of comet Halley's dust environment are highlighted. Spacecraft results on the dust composition, the detection of subfemtogram grains, and the particle-mass distribution; jets and the dust-emission pattern; the existence of discrete sources on the nucleus surface and the determination of their locations from day-to-day motions of coma features; CN jets; large-scale phenomena, including an antitail, streamers, and a sunward spike; infrared observations, such as the 3.4 microns emission feature, applications of array detectors, and rare far-infrared data; the chemical modification of low-temperature ices by UV and cosmic-ray irradiation processes, their laboratory simulations, and applications to the evolution of comets; the interstellar-connection models of comet origin; and the formation of a mantle made of refractory organic material on the nucleus surface.

Sekanina, Z.↗

Nature's crucible: Manufacturing optical nonlinearities for high resolution, high sensitivity encoding in the compound eye of the fly, Musca domestica

The number of pixels per unit area sampling an image determines Nyquist resolution. Therefore, the highest pixel density is the goal. Unfortunately, as reduction in pixel size approaches the wavelength of light, sensitivity is lost and noise increases. Animals face the same problems and have achieved novel solutions. Emulating these solutions offers potentially unlimited sensitivity with detector size approaching the diffraction limit. Once an image is 'captured', cellular preprocessing of information allows extraction of high resolution information from the scene. Computer simulation of this system promises hyperacuity for machine vision.

Wilcox, Mike↗

Hires and beyond

The High-Resolution image construction program (HiRes) used at IPAC is based on the Maximum Correlation Method. After HiRes intensity images are constructed from IRAS data, additional images are needed to aid in scientific interpretation. Some of the images that are available for this purpose show the fitting noise, estimates of the achieved resolution, and detector track maps. Two methods have been developed for creating color maps without discarding any more spatial information than absolutely necessary: the 'cross-band simulation' and 'prior-knowledge' methods. These maps are demonstrated using the survey observations of a 2 x 2 degree field centered on M31. Prior knowledge may also be used to achieve super-resolution and to suppress ringing around bright point sources observed against background emission. Tools to suppress noise spikes and for accelerating convergence are also described.

Fowler, John W.↗

Swift Burst Alert Telescope (BAT) Instrument Response

The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. In this talk, we describe the BAT instrument response as determined to an accuracy suitable for gamma-ray burst studies. We will also discuss the public data analysis tools developed to calculate the BAT response to sources at different energies and locations in the FOV. The level of accuracy required for the BAT instrument response used for the hard x-ray survey is significantly higher because this response must be used in the iterative clean algorithm for finding fainter sources. Because the bright sources add a lot of coding noise to the BAT sky image, fainter sources can be seen only after the counts due to the bright sources are removed. The better we know the BAT response, the lower the noise in the cleaned spectrum and thus the more sensitive the survey. Since the BAT detector plane consists of 32768 individual, 4 mm square CZT gamma-ray detectors, the most accurate BAT response would include 32768 individual detector response functions to separate mask modulation effects from differences in detector efficiencies! We describe OUT continuing work to improve the accuracy of the BAT instrument response and will present the current results of Monte Carlo simulations as well as BAT ground calibration data.

Parsons, A.↗

Comparisons of Integrated Radiation Transport Models with Microdosimetry Data in Spaceflight

Astronauts are exposed to galactic cosmic rays (GCR), trapped protons, and possible solar particle events (SPE) during spaceflight. For such complicated mixtures of radiation types and kinetic energies, tissue equivalent proportional counters (TEPC's) represent a simple time-dependent approach for radiation monitoring. Of interest in radiation protection is the average quality factor of a radiation field defined as a function of linear energy transfer, LET, Q(sub ave)(LET). However TEPC's measure the average quality factors as a function of lineal energy (y), Q(sub ave)(y) defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector. Using integrated space radiation models that includes the transport code HZETRN/BRYNTRN, the quantum nuclear interaction model, QMSFRG, and results from Monte-Carlo track simulations of TEPC's response to ions, we consider comparisons of model calculations to TEPC results from NASA missions in low Earth orbit and make predictions for lunar and Mars missions. Good agreement between the model and measured spectra from past NASA missions is found. A finding of this work is that TEPC's values for trapped or solar protons of Q(sub ave)(y) range from 1.9-2.5, overestimating Q(sub ave)(LET), which ranges from 1.4-1.6 with both quantities increasing with shielding depth due to nuclear secondaries Comparisons for the complete GCR spectra show that Q(sub ave)(LET) for GCR is approximately 3.5-4.5, while TEPC's measure 2.9-3.4 for Q(sub ave)(y) with the GCR values decreasing with depth as heavy ions are absorbed in shielding material. Our results support the use of TEPC's for space radiation environmental monitoring when computational analysis is used for proper data interpretation.

Cucinotta, Francis A.↗

Extended HXR Sources - Albedo Patches or Coronal Sources

Extended HXR sources in the presence of compact footpoints have been reported based on visibility amplitudes from different detectors. Attempts have been made to determine the location and extent of these sources through direct imaging. Results of this work will be described for simulated sources and for specific flares at different solar longitudes, with a discussion of the possible nature of the extended sources as either albedo patches or coronal sources or a combination of the two.

Dennis, Brian R.↗

Thermal Impact of Cosmic Ray Interaction with an XRay Microcalorimeter Array

The X-ray Integral Field Unit (X-IFU) instrument on the Athena mission will be positioned at the Lagrangian point L2 and be subject to cosmic rays generated by astrophysics sources, primarily relativistic protons. Previous simulations have shown that particles of energy higher than 150 MeV will make it through the outer layers of the satellite. They will reach the detector wafer with a rate of 3 cts/sq. cm/s and a most probable energy deposited in the Si frame supporting the array at 150 keV. These events can affect the energy resolution of the detectors through the thermal fluctuations that they produce. This study assesses this potential problem and discusses two suggested design approaches to decrease the impact of cosmic ray in order to limit their effect to their allocation of 0.2 eV within the Athena/X-IFU energy-resolution budget. The first is the addition of a coating layer of high heat capacity material (e.g., Pd) and the second is the splitting of this coating into two thermal regions near the TES array to keep the heat away from the array. Implementing these two features is predicted to cause a decrease in the number of events above 1 μK by more than a factor 10 to ~ 1.5 cps when compared to an equivalent design without these features.

Antoine R. Miniussi↗

JWST/MIRI Coronagraphic Performances as Measured on-Sky

Context . Characterization of directly imaged exoplanets is one of the most eagerly anticipated science functions of the James Webb Space Telescope . MIRI, the mid-IR instrument, has the capability to provide unique spatially resolved photometric data points in a spectral range never before achieved for such objects. Aims . We aim to present the very first on-sky contrast measurements of the MIRI coronagraphs. In addition to a classical Lyot coronagraph at the longest wavelength, this observing mode implements the concept of the four-quadrant phase mask for the very first time in a space telescope. Methods . We observed single stars together with a series of reference stars to measure raw contrasts as they are delivered on the detector, as well as reference-subtracted contrasts. Results . The MIRI coronagraphs achieve raw contrasts better than 10 −3 at the smallest angular separations (within 1″) and about 10 −5 farther out (beyond 5 ~ 6″). Subtracting the residual diffracted light left behind the coronagraph has the potential to bring the final contrast down to the background- and detector-limited noise floor at most angular separations (a few times 10 −5 at less than 1″). Conclusions . The MIRI coronagraphs behave as expected from simulations. In particular, the raw contrasts for all four coronagraphs are fully consistent with the diffractive model. Contrasts obtained by subtracting reference stars also meet expectations and are fully demonstrated for two four-quadrant phase masks (F1065C and F1140C). The worst contrast, measured at F1550C, is very likely due to a variation in the phase aberrations at the primary mirror during the observations, and not an issue with the coronagraph itself. We did not perform reference star subtraction with the Lyot mask at F2300C, but we anticipate that it would bring the contrast down to the noise floor.

High angular resolution instrumentation↗

X-ray Polarimetry with a Micro-Pattern Gas Detector

Topics covered include: Science drivers for X-ray polarimetry; Previous X-ray polarimetry designs; The photoelectric effect and imaging tracks; Micro-pattern gas polarimeter design concept. Further work includes: Verify results against simulator; Optimize pressure and characterize different gases for a given energy band; Optimize voltages for resolution and sensitivity; Test meshes with 80 micron pitch; Characterize ASIC operation; and Quantify quantum efficiency for optimum polarization sensitivity.

Hill, Joe↗

Laboratory evaluation of Fecker and Loral optical IR PWI systems

A previous flight test of two electro-optical pilot warning indicators, using a flashing xenon strobe and silicon detectors as cooperative elements, pointed out several design deficiencies. The present laboratory evaluation program corrected these faults and calibrated the sensitivity of both systems in azimuth elevation and range. The laboratory tests were performed on an optical bench and consisted of three basic components: (1) a xenon strobe lamp whose output is monitored at the indicator detector to give pulse to pulse information on energy content at the receiver; (2) a strobe light attenuating optical system which is calibrated photometrically to provide simulated range; and (3) a positioning table on which the indicator system under study is mounted and which provides spatial location coordinates for all data points. The test results for both systems are tabulated.

Gorstein, M.↗

Investigation of electrical noise in selenium-immersed thermistor bolometers

The selenium immersed, thermistor bolometer, IR detector failed due to spurious and escalating electrical noise outburst as a function of time at elevated temperatures during routine ground based testing in a space simulated environment. Spectrographic analysis of failed bolometers revealed selenium pure zones in the insulating selenium arsenic (Se-As) glass film which surrounds the active sintered Mn, Ni, Co oxide flake. The selenium pure film was identified as a potentially serious failure mechanism. Significant changes were instituted in the manufacturing techniques along with more stringent process controls which eliminated the selenium pure film and successfully produced 22study bolometers.

Tarpley, J. L.↗

Experimental flaw detection by scattering of plate waves

The surface displacements of elastic waves scattered from a surface-breaking crack are measured with a capacitive transducer on a 2D plate, and comparisons with theoretical predictions are reported. The noncontacting detector has a wide and flat frequency response which measures the response of a glass plate to the propagation of Rayleigh-Lamb waves. A theoretical simulation of the surface displacements is generated by multiplying experimental traces with a cosine window, and Green's function is used to compute the source function. Power spectra are also recorded from the experiment to compare the results with a finite-element model of the crack, and good agreement is reported for results in both the time and frequency domains. The crack can be detected in the far field when the spacing of the receiver locations is small, and the transducer/probe appears to be a practical flaw-detection instrument.

Spetzler, Hartmut↗