Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Fixed Source Sensitivity Calculations for Inertial Confinement Fusion Applications

A numerical code library was developed for the radiation transport code MCNP6.3 to calculate generalized response sensitivity coefficients for fixed source neutron transport problems with applications to inertial confinement fusion (ICF) experiments. The new MCNP6.3 dependency is used to generate a novel time convolution response that represents a neutron time-of-flight (nToF) signal. The traditional suite of macroscopic cross-section sensitivities and constrained fixed source probability distribution sensitivities are available for both the standard and the new response tallies in this library. However, novel sensitivity coefficients for the constrained hyperparameters of analytic fixed source probability distributions are emphasized in this work for their connection to ICF neutron transport models. Particularly, advanced Monte Carlo methods are developed for calculating the sensitivity of a nToF signal to perturbations in an ICF plasma’s ion temperature and burn history as well as perturbations in the target liner mass density and the shape parameters of the nToF detector’s impulse response function. Together, these capabilities form an advanced suite of computational tools that can be used to analyze and extract information from any ICF experimental platform.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization and description of a spectrum unfolding method for the $\mathrm{CATRiNA}$ neutron detector array

We report the CATRiNA deuterated neutron detector array at Florida State University consists of 16 2" x 2" and 16 $" x 2" EJ-315 detectors with characteristic light output and pulse-shape discrimination capabilities. The unique properties of the detectors, in part due to the anisotropic nature of (d,n) scattering, are used to extract the energy of neutrons via pulse-height spectrum unfolding. The unfolding method uses the light output and response matrix of the detectors to extract neutron energies, independent of the traditional time-of-flight (ToF) technique. Detailed response matrices of the CATRiNA detectors were measured at the Edwards Accelerator Laboratory at Ohio University via the 9 Be(d,n) and 27 Al(d,n) reactions. Full characterization of the detectors using digital electronics, as well as a description of the unfolding method are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

Excitation spectral microscopy for highly multiplexed fluorescence imaging and quantitative biosensing

The multiplexing capability of fluorescence microscopy is severely limited by the broad fluorescence spectral width. Spectral imaging offers potential solutions, yet typical approaches to disperse the local emission spectra notably impede the attainable throughput. Here we show that using a single, fixed fluorescence emission detection band, through frame-synchronized fast scanning of the excitation wavelength from a white lamp via an acousto-optic tunable filter, up to six subcellular targets, labeled by common fluorophores of substantial spectral overlap, can be simultaneously imaged in live cells with low (~1%) crosstalks and high temporal resolutions (down to ~10 ms). The demonstrated capability to quantify the abundances of different fluorophores in the same sample through unmixing the excitation spectra next enables us to devise novel, quantitative imaging schemes for both bi-state and Förster resonance energy transfer fluorescent biosensors in live cells. We thus achieve high sensitivities and spatiotemporal resolutions in quantifying the mitochondrial matrix pH and intracellular macromolecular crowding, and further demonstrate, for the first time, the multiplexing of absolute pH imaging with three additional target organelles/proteins to elucidate the complex, Parkin-mediated mitophagy pathway. Together, excitation spectral microscopy provides exceptional opportunities for highly multiplexed fluorescence imaging. The prospect of acquiring fast spectral images without the need for fluorescence dispersion or care for the spectral response of the detector offers tremendous potential.

59 BASIC BIOLOGICAL SCIENCES↗

Nucleation-controlled growth of superior lead-free perovskite Cs 3 Bi 2 I 9 single-crystals for high-performance X-ray detection

The organic-inorganic hybrid lead halide perovskites have emerged as a series of star materials for solar cells, lasers and detectors. However, the issues raised by the toxic lead element and marginal stability due to the volatile organic components have severely limited their potential applications. In this work, we develop a nucleation-controlled solution method to grow large size high-quality Cs 3 Bi 2 I 9 perovskite single crystals (PSCs). Using the technique, we harvest some centimeter-sized single crystals and achieved high device performance. We find that X-ray detectors based on PSCs exhibit high sensitivity of 1652.3 μC Gy air -1 cm -2 and very low detectable dose rate of 130 nGy air s -1 , both desired in medical diagnostics. In addition, its outstanding thermal stability inspires us to develop a high temperature X-ray detector with stable response at up to 100 °C. Furthermore, PSCs exhibit high X-ray imaging capability thanks to its negligible signal drifting and extremely high stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements of electron temperature in high-energy-density plasmas using gated x-ray pinhole imaging

We present measurements of spatially and temporally resolved electron temperature in high-energy-density plasmas using gated x-ray pinhole imagers. A 2D image of bremsstrahlung x-ray self-emission from laser-driven plasma plumes is detected at the same time through two pinholes covered with different filter materials. By comparing the attenuated signal through each filter, a spatially resolved electron temperature as low as 0.1 keV can be estimated. Measurements of the plasma plume taken from different directions indicate that imaging through extended plasmas has a negligible effect on the temperature estimates. Methods for estimating the expected signal, selecting filters, and incorporating the response of the detector are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of the CMS Zero Degree Calorimeters in pPb collisions at the LHC

The two Zero Degree Calorimeters (ZDCs) of the CMS experiment are located at ± 140 m from the collision point and detect neutral particles in the |η| > 8.3 pseudorapidity region. This paper presents a study on the performance of the ZDC in the 2016 pPb run. The response of the detectors to ultrarelativistic neutrons is studied using in-depth Monte Carlo simulations. A method of signal extraction based on template fits is presented, along with a dedicated calibration procedure. A deconvolution technique for the correction of overlapping collision events is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance study of a 3×1×1 m 3 dual phase liquid Argon Time Projection Chamber exposed to cosmic rays

We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3×1×1 m 3 ) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of the TPC's response, its main detector parameters and performance. The results are important for the understanding and further developments of the dual-phase technology, thanks to the verification of key aspects, such as the extraction of electrons from liquid to gas and their amplification through the entire one square metre readout plain, gain stability, purity and charge sharing between readout views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generative adversarial networks for scintillation signal simulation in EXO-200

Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network — a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. Furthermore, the network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.

47 OTHER INSTRUMENTATION↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Learning broken symmetries with approximate invariance

Recognizing symmetries in data allows for significant boosts in neural network training, which is especially important where training data are limited. In many cases, however, the exact underlying symmetry is present only in an idealized dataset, and is broken in actual data, due to asymmetries in the detector, or varying response resolution as a function of particle momentum. Standard approaches, such as data augmentation or equivariant networks fail to represent the nature of the full, broken symmetry, effectively overconstraining the response of the neural network. We propose a learning model which balances the generality and asymptotic performance of unconstrained networks with the rapid learning of constrained networks. This is achieved through a dual-subnet structure, where one network is constrained by the symmetry and the other is not, along with a learned symmetry factor. In a simplified toy example that demonstrates violation of Lorentz invariance, our model learns as rapidly as symmetry constrained networks but escapes its performance limitations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Forward Modeling of Gamma Reaction History Signatures From Anticipated Deuterium-Tritium Filled MagLIF Implosions on Sandia’s Z-Machine

Nuclear reaction history measurements provide a bang time and burn width of Inertial Confinement Fusion (ICF) implosions and are essential for understanding implosion performance to constrain ICF capsule design. When fusion fuel contains Deuterium (D) and Tritium (T) gas, reaction history is informed by measuring the 16.75 MeV gamma rays generated from the D(T,γ) 5 He reaction. Such DT based reaction history measurements have not been made on the Magnetized Laser Inertial Fusion (MagLIF) platform on Sandia’s Z-Machine due to the lack of Tritium being used. The recent development of ICF implosions with tritiated fuel will open the possibility of measuring the gamma reaction history on the Z-Machine. A forward model of the Gamma Reaction History diagnostic on Z (GRH-Z) has been developed using the MCNP6.3 (Monte-Carlo N-Particle) radiation transport code. The model included the Z-Machine geometry of interest to characterize the impact of neutron induced gamma rays on the DT reaction history measurements. In addition, the impulse response functions of the GRH-Z diagnostic to understand the temporal response of the detector, and the minimum yields required to make a reaction history measurement were calculated. This approach also predicted that with T 2 gas doping of MagLIF implosions a reaction history may be made for high performance shots >8e12-2.4e13 depending on the chosen threshold for the detector, with a maximum signal to background ratio of 25%. It was found that for long duration ICF implosions that additional collimation will be needed to prevent the neutron induced gamma rays from modifying the shape of the measured DT reaction history curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

Full event particle-level unfolding with variable-length latent variational diffusion

The measurements performed by particle physics experiments must account for the imperfect response of the detectors used to observe the interactions. One approach, unfolding, statistically adjusts the experimental data for detector effects. Recently, generative machine learning models have shown promise for performing unbinned unfolding in a high number of dimensions. However, all current generative approaches are limited to unfolding a fixed set of observables, making them unable to perform full-event unfolding in the variable dimensional environment of collider data. A novel modification to the variational latent diffusion model (VLD) approach to generative unfolding is presented, which allows for unfolding of high- and variable-dimensional feature spaces. The performance of this method is evaluated in the context of semi-leptonic t\bar{t} t t ‾ production at the Large Hadron Collider.

Shmakov, Alexander↗

Time Shifted Transport Tallies

When modeling experiments on platforms such as the National Ignition Facility (NIF), several different calculations are strung together to calculate the final diagnostic response of the detectors on the machine. For example, a highly detailed simulation may be performed of capsule implosion on NIF, where one of the key diagnostics is the history of the thermal radiation emission from the capsule. This simulation domain can be a few centimeters in size. The NIF target chamber is much larger, so a second calculation can be done to transport the energy from the capsule out to the diagnostics. Typically, the results from the first calculation are used as a point source in the second, since all the fine detail is not needed.

97 MATHEMATICS AND COMPUTING↗

Gamma-ray Spectroscopy in Low-Power Nuclear Research Reactors

Gamma-ray spectroscopy is an effective technique for radioactive material characterization, routine inventory verification, nuclear safeguards, health physics, and source search scenarios. Gamma-ray spectrometers typically cannot be operated in the immediate vicinity of nuclear reactors due to their high flux fields and their resulting inability to resolve individual pulses. Low-power reactor facilities offer the possibility to study reactor gamma-ray fields, a domain of experiments hitherto poorly explored. In this work, we present gamma-ray spectroscopy experiments performed with various detectors in two reactors: The EPFL zero-power research reactor CROCUS, and the neutron beam facility at the Ohio State University Research Reactor (OSURR). We employed inorganic scintillators (CeBr3), organic scintillators (trans-stilbene and organic glass), and high-purity germanium semiconductors (HPGe) to cover a range of typical—and new—instruments used in gamma-ray spectroscopy. The aim of this study is to provide a guideline for reactor users regarding detector performance, observed responses, and therefore available information in the reactor photon fields up to 2 MeV. The results indicate several future prospects, such as the online (at criticality) monitoring of fission products (like Xe, I, and La), dual-particle sensitive experiments, and code validation opportunities.

Pakari, Oskari V. (ORCID:0000000337048190)↗

Peak Prediction Using Multi Layer Perceptron (MLP) for Edge Computing ASICs Targeting Scientific Applications

High data rate detectors play an integral part in scientific research and their development is actively pursued at High Energy Physics (HEP) facilities around the world. Edge Machine Learning (ML) offers the ability to reduce data rates by integrating ML algorithms into Application Specific Integrated Circuits (ASICs) on the front end electronics. In this work, we explore a set of neural network architectures for predicting the peak amplitudes in the detector's sensor response. We have designed and synthesized several MLP based neural networks comparing their inference accuracy, power consumption, and area targeting for minimal latency. The neural networks are synthesized in a commercial 65nm process. The effect of quantizing the network's weights and biases on hardware performance and area is reported. We also conduct design space exploration to compare between design alternatives

47 OTHER INSTRUMENTATION↗

A new generation of direct X-ray detectors for medical and synchrotron imaging applications

Abstract Large-area X-ray imaging is one of the most widely used imaging modalities that spans several scientific and technological fields. Currently, the direct X-ray conversion materials that are being commercially used for large-area (> 8 cm × 4 cm without tiling) flat panel applications, such as amorphous selenium (a-Se), have usable sensitivities of up to only 30 keV. Although there have been many promising candidates (such as polycrystalline HgI 2 and CdTe), none of the semiconductors were able to assuage the requirement for high energy (> 40 keV) large-area X-ray imaging applications due to inadequate cost, manufacturability, and long-term performance metrics. In this study, we successfully demonstrate the potential of the hybrid Methylammonium lead iodide (MAPbI 3 ) perovskite-based semiconductor detectors in satisfying all the requirements for its successful commercialization in synchrotron and medical imaging. This new generation of hybrid detectors demonstrates low dark current under electric fields needed for high sensitivity X-ray imaging applications. The detectors have a linear response to X-ray energy and applied bias, no polarization effects at a moderate bias, and signal stability over long usage durations. Also, these detectors have demonstrated a stable detection response under BNL’s National Synchrotron Light Source II (NSLS-II) 70 keV monochromatic synchrotron beamline.

47 OTHER INSTRUMENTATION↗