Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Calibration and performance of the Viking lander cameras

The paper discusses Viking lander cameras which have an angular resolution of 0.12 deg, and (for broadband imaging) a resolution of 0.04 deg, used for the acquisition of data in six spectral bands for color and near-infrared imaging. Attention is given to photogrammetric calibration techniques used in the determination of spatial and spectral brightness variations from image data. The effects of sampling on the achievable photogrammetric precision are described along with techniques for preflight spectral calibrations and the corrections required for degradation in the infrared response of the detectors. The effects of the known internal reflections on the qualitative images (such as the appearance of artifact clouds) are presented, noting their effects on skyline radiometry. The qualitative and quantitative effects of the signal quantization are briefly reviewed.

Patterson, W. R., III↗

Radiometric correction of LANDSAT data

The author has identified the following significant results. The six independent sensors of the multispectral band scanner are supposed to be identical; however, in actual practice, they may have different gain settings and offset factors, which result in the effect known as stripping (black lines at regular intervals) of the imagery. A simple two parameter method to correct the gain settings and offset factors of each of the sensors with respect to one sensor, taken as reference, was developed. This method assumes: (1) the response of a detector varies linearly with the radiance of radiation received, and (2) the means, as well as the standard deviations, of a reasonably large number of pixels, in a given wavelength band, are equal for each of the detectors for the radiometrically corrected data.

Dejesusparada, N.↗

Performance evaluation and calibration of a modular multiband radiometer for remote sensing field research

A multiband radiometer suitable for operation from helicopter, small plane, truck, or tripod platforms was developed. The standard unit is equipped with the seven thematic mapper spectral bands with an added band from 1.5 to 1.30 microns; however, up to eight user specified bands from 0.4 to 15 microns may be installed under clean field conditions. Results of prototype tests of the spectral responsivity of the detectors, the transmittance of the optical filters as a function of wavelength, the fields of view, and the system linearity, temperature stability, noise performance, and dynamic range were evaluated. Minor modifications were made to the instrument and the results of final testing are reported.

Robinson, B. F.↗

Limits to the burster repetition rate as deduced from the 2nd catalog of the interplanetary network

The burster repetition rate is an important parameter in many gamma ray burst models. The localizations of the interplanetary network, which have a relatively small combined surface area, may be used to estimate the average repetition rate. The method consists of (1) estimating the number of random overlaps between error boxes expected in the catalog and comparing this number to that actually observed; (2) modeling the response of the detectors in the network, so that the probability of detecting a burst can be estimated; and (3) simulating the arrival of bursts at the network assuming that burster repetition is governed by a Poisson process. The application of this method for many different burster luminosity functions shows that (1) the lower limit to the burster repetition rate depends strongly upon the assumed luminosity function; (2) the best lower limit to the repetition period obtainable from the data of the network is about 100 months; and (3) that a luminosity function for all bursters similar to that of the 1979 Mar 5 burster is inconsistent with the data.

Atteia, J. L.↗

Structure of the Uranian rings. I - Square-well model and particle-size constraints

A least squares fitting is added to the diffraction model for the Uranian rings and the model is then used to determine the relative optical depths of the rings at visible and near-IR wavelengths. Light transmission is assumed constant on a scale of a few radial km in the rings. The amount of starlight passing through the rings is calculated from occultations with account taken of a monolayer ring, diffraction effects, and multiple ring layers. A diffracted occultation profile is generated with consideration given to the angular diameter of the star, the impulse response of the detector, and atmospheric aberrations. Calculation procedures which remove noise are outlined and results are compared with the observational data base. The wavelength dependence of optical depth is formulated. It is shown that occultation data do not support the presence of a large fraction of submicron particles. No optical depth variations are projected for 0.88-2.2 microns wavelengths. Unchopped data are needed to verify the model predictions.

Elliot, J. L.↗

Photometry of Phoebe

The nonsynchronous rotational period and light curve for Phoebe are analyzed. The variations in CCD chip pixel response, the intensity of the images, the sky background level, and the atmospheric effects and color response of the detector are examined. Consideration is also given to brightness variations and the solar phase function at small phase angles (0.2-1.2 deg) of the light curve. The Phoebe surface is compared with asteroid surfaces by fitting the data to a linear phase function. It is determined that the Phoebe's sidereal rotational period is refined to 9.282 + or - 0.015 hr, the light curve in V filter exhibits 20 percent brightness variations with weaker higher-order harmonics, and the solar phase coefficient at angles less than 1.2 deg is 0.180 + or 0.035 mag/deg. The Phoebe data at small phase angles correlated well with a phase function for C-type asteroids.

Kruse, S.↗

Performance of the large-area detectors for the Burst and Transient Source Experiment (BATSE) on the Gamma Ray Observatory

BATSE, one of four experiments on the Gamma Ray Observatory (GRO), is expected to provide the most sensitive observations of gamma-ray bursts yet obtained, as well as to provide long-term monitoring of hard X-ray and low-energy gamma-ray emission from bright pulsating sources, transients, and solar flares. Eight uncollimated modules, positioned at the corners of the spacecraft to provide an unobstructed view of the sky, detect sources by various techniques based on time variability. Use of detectors with anisotropic response allows location of gamma-ray bursts to be determined to an accuracy of about 1 deg using BATSE data alone. The completed BATSE underwent intensive testing and calibration prior to its delivery in October 1988.

Paciesas, W. S.↗

The Near-Earth Asteroid Rendezvous (NEAR) Mission, the Mars Surveyor 2001 (MS01) Mission, and the Planetary Instrument Definition and Development Program (PIDDP)

The NEAR Mission was launched on February 17, 1996 for a three year cruise to the asteroid 433 Eros. During October, November, and December 1998 cruise measurements with the gamma-ray spectrometer were made at three different escape-window-width settings. These were done in order to understand how the count rate and peak width change as the window width settings change. Analysis of these spectra was completed using the latest version of the spectral analysis program, RobWin. Results as a function of energy were combined with the results from the Schlumberger-Doll Research experiments (described below). Laboratory measurements were needed to confirm efficiency calculations above 6 MeV and to understand the relationship between the full energy peak areas and the areas of the first and second escape peaks as a function of the escape peak widths. A week of measurements was made at Schlumberger-Doll Research using their 14-MeV pulsed neutron generator and large soil samples. Data were collected after adding iron and nickel to the sample to increase the emission of high-energy lines. Approximately 24 hours of data were accumulated at each of three escape peak window widths. These data were analyzed with RobWin. Combining results from the cruise measurements and the laboratory measurements indicated that both data sets had similar energy dependence and that this energy dependence was different from that obtained using standard Monte Carlo calculations. Alternate methods of simulating the response of the detector to changes in the escape window widths are being investigated.

Source record↗

Absolute Effective Area of the Chandra High-Resolution Mirror Assembly

The Chandra X-ray Observatory was launched in July 1999, and is returning exquisite sub-arcsecond x-ray images of star groups, supernova remnants, galaxies, quasars, and clusters of galaxies. In addition to being the premier X-ray observatory in terms of angular and spectral resolution, Chandra is the best calibrated X-ray facility ever flown. We discuss here the calibration of the effective area of the High Resolution Mirror Assembly. Because we do not know the absolute X-ray flux density of any celestial source, this must be based primarily on ground measurements and on modeling. In particular, we must remove the calibrated modeled responses of the detectors and gratings to obtain the mirror area. For celestial sources which may be assumed to have smoothly varying spectra, such as the Crab Nebula, we may verify the continuity of the area calibration as a function of energy. This is of significance in energy regions such as the Ir M-edges, or near the critical grazing angle cutoff of the various mirror shells.

Schwartz, D. A.↗

Relative Efficiency of TLD-100 to High Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to 137Cs) dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, G. D.↗

Relative Efficiency of TLD-100 to Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to (137)Cs dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, Gautam D.↗

Calibration of the NEAR XRS Solar Monitor

The NEAR-Shoemaker X-ray spectrometer measured elemental abundance ratios for six elements (Mg, Al, Si, S, Ca, Fe) on the surface of 433 Eros by remote-sensing x-ray fluorescence spectroscopy (1,2). The fluorescent x-rays are excited by x-rays from the solar corona. Therefore, accurate knowledge of the incident solar spectrum was critically important to interpreting the fluorescence spectra received by the NEAR detectors in terms of elemental ratios on the asteroid's surface. NEAR, therefore, carried two additional X-ray spectrometers dedicated to monitoring the solar spectrum between 1 and 10 keV. One of these, a Si PIN photodiode, failed prior to orbit insertion. The second consisted of a gas-filled proportional counter similar to the asteroid-pointing detectors, but covered by a graded filter (3) intended to attenuate the incoming solar flux and increase the dynamic range of the detector. Unfortunately, the response of this filter as a function of solar incidence angle was not adequately determined in the laboratory prior to launch. The response function had to be calculated from the assumed properties of the graded filter.

Lim, L. F.↗

SRAM Detector Calibration

Custom proton sensitive SRAM chips are being flown on the BMDO Clementine missions and Space Technology Research Vehicle experiments. This paper describes the calibration procedure for the SRAM proton detectors and their response to the space environment.

SRAM BMDO Clementine↗

Interpretation of TEPC Measurements in Space Flights for Radiation Monitoring

For the proper interpretation of radiation data measured in space, the results of integrated radiation transport models were compared with the tissue equivalent proportional counter (TEPC) measurements. TEPC is a simple, time-dependent approach to radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Qave(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Qave(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. The deviation of y from LET is caused by energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. The response distribution functions of the wall-less and walled TEPCs were calculated from Monte-Carlo track simulations. Using an integrated space radiation model (which includes the transport codes HZETRN and BRYNTRN, and the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions from Monte-Carlo track simulations, we compared model calculations with the walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. Good agreement was found for Qave(y) between the model and measured spectra from past NASA missions. The Qave(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Qave(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Qave(y). The GCR values are decreasing with the shield thickness. Our analysis of the measurements of TEPCs can be used for a proper interpretation of observed data of monitoring the space radiation environment.

Kim, Myung-Hee Y.↗

Multi-Band Large Format Infrared Imaging Arrays

Large-format and multi-band focal plane arrays (FPA) based on quantum well and quantum dot infrared photodetectors have been developed for various instruments such as imaging interferometers and hyperspectral imagers. The spectral response of these detectors are tailorable within the mid- and long-wavelength infrared bands.

infrared↗

Theoretical Noise Analysis on a Position-sensitive Metallic Magnetic Calorimeter

We report on the theoretical noise analysis for a position-sensitive Metallic Magnetic Calorimeter (MMC), consisting of MMC read-out at both ends of a large X-ray absorber. Such devices are under consideration as alternatives to other cryogenic technologies for future X-ray astronomy missions. We use a finite-element model (FEM) to numerically calculate the signal and noise response at the detector outputs and investigate the correlations between the noise measured at each MMC coupled by the absorber. We then calculate, using the optimal filter concept, the theoretical energy and position resolution across the detector and discuss the trade-offs involved in optimizing the detector design for energy resolution, position resolution and count rate. The results show, theoretically, the position-sensitive MMC concept offers impressive spectral and spatial resolving capabilities compared to pixel arrays and similar position-sensitive cryogenic technologies using Transition Edge Sensor (TES) read-out.

Smith, Stephen J.↗

Initial On-Orbit Radiometric Calibration of the Suomi NPP VIIRS Reflective Solar Bands

The on-orbit radiometric response calibration of the VISible/Near InfraRed (VISNIR) and the Short-Wave InfraRed (SWIR) bands of the Visible/Infrared Imager/Radiometer Suite (VIIRS) aboard the Suomi National Polar-orbiting Partnership (NPP) satellite is carried out through a Solar Diffuser (SD). The transmittance of the SD screen and the SD's Bidirectional Reflectance Distribution Function (BRDF) are measured before launch and tabulated, allowing the VIIRS sensor aperture spectral radiance to be accurately determined. The radiometric response of a detector is described by a quadratic polynomial of the detector?s digital number (dn). The coefficients were determined before launch. Once on orbit, the coefficients are assumed to change by a common factor: the F-factor. The radiance scattered from the SD allows the determination of the F-factor. In this Proceeding, we describe the methodology and the associated algorithms in the determination of the F-factors and discuss the results.

Lei, Ning↗

Organism/Organic Exposure to Orbital Stresses (OOREOS) Satellite: Radiation Exposure in LEO and Supporting Laboratory Studies

We will present the results from the exposure of the metalloporphyrin iron tetraphenylporphyrin chloride (FeTPPCI), anthraufin (C(sub 14)H(sub 8)(O sub 4) (Anth) and Isoviolanthrene (C(sub 34H sub 18) (IVA) to the outher space environment, measured in situ aboard the Organism/Organic Exposure to Orbital Stresses nanosatellite. The compounds were exposed for a period of 17 months (3700 hours of direct solar exposure) including broad-spectrum solar radiation (approx. 122 nm to the near infrared). The organic films are enclosed in hermetically sealed sample cells that contain one of four astrobiologically relevant microenvironments. Transmission spectra (200-1000 nm) were recorded for each film, at first daily and subsequently every 15 days, along with a solar spectrum and the dark response of the detector array. In addition to analysis via UV-Vis spectroscopy, the laboratory controls were also monitored via infrared and far-UV spectroscopy. The results presented will include the finding that the FeTPPCI and IVA organic films in contact with a humid headspace gas (0.8-2.3%) exhibit faster degradation times, upon irradiation, in comparison with identical films under dry headspaces gases, whereas the Anth thin film exhibited a higher degree of photostability. In the companion laboratory experiments, simulated solar exposure of FeTPI films in contact with either Ar or CO(sub -2):O(sub -2):Ar (10:0.01:1000) headspace gas results in growth of a band in the films infrared spectra at 1961 cm(sup 1). Our assignment of this new spectral feature and the corresponding rational will be presented. The relevance of O/OREOS findings to planetary science, biomarker research, and the photostability of organic materials in astrobiologically relevant environments will also be discussed.

Radiation Exposure↗