Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Identification of Leakage Spectra from Neutron Activation in Glass/Cherenkov Detectors - Paper 96

Oak Ridge National Laboratory has developed a new detector system concept that can be deployed in major US cities to identify the leakage spectrum of a nuclear weapon detonation. The detector is based on a small piece of glass that has been doped with an element that has a high activation cross section and creates a radioactive activation product with a reasonable length half-life. The decay of the activation product(s) after exposure creates Cherenkov light which can propagate to a photomultiplier and can be turned into a count-rate signal. The signal from each glass in each detector in a city can be individually analyzed to determine the amount of activation products produced in the initial exposure. Several activation products can be determined in a single glass if the half-lives are not the same. With a known source location and a detailed 3D model of a city, neutron transport simulations can be made by using a library of known sources to predict the activation amounts each source would have made in the glass detectors. A simple comparison of the measured activation amounts and the predicted activation amounts can identify the source spectrum contained in the library that is the best match. Choosing dopants with a large range in the threshold energy for the activation reactions can help to differentiate the spectra in the library. The method of matching the measured activation amounts to the predicted activation amounts to identify the source spectrum is similar to the analysis used for the passive Activation Foil Integrated Detector System (AFIDS), also developed at Oak Ridge National Laboratory. In AFIDS, wires or foils of known mass and isotopic composition are deployed before and then collected after exposure. Counting gammas in a nearby laboratory determines the activation amounts. The glass/Cherenkov system is active - it uses a battery-powered detector to count flashes of Cherenkov light and to communicate its count rates to a remote location for further analysis. Work has been performed in several areas, including glass making, automated detection and communication systems and software tools for analysis of the signal and source spectrum identification. Bell and Boatner have developed phosphate glasses that incorporate elements with high capture cross sections, and Hayward has simulated the response with Geant4 and measured the response with isotopic gamma sources. This paper will focus on the software tools for determining the activation amounts from the Cherenkov count-rate signal and finding the best matching source spectrum. A test problem in an urban environment is used to demonstrate the potential of a spectrum identification system using neutron activation. The analysis methods developed to identify the neutron leakage spectra from Cherenkov light given off by neutron activation in doped glasses work well. The calculation used to unfold the count-rate information into the number of actual activation products uses robust algorithms that can also compute associated uncertainties. These uncertainties and the known uncertainties of the glass tube material compositions are incorporated into the matching analysis to determine which of the source spectra in the library best matches the measured activation data. Any measurement method used to identify a neutron source spectrum relies at some point on a comparison against known sources; no identification method is definitive. Detection systems measure some physical aspect of the source, not its serial number. Many systems measure the physical aspect to determine that the source has some property, and then leave it to experts to determine which potential sources share that property. The analysis system presented here incorporates the comparison into the analysis itself. The statistical tests show which of the known library sources match the measured data the best and whether that match is a good match. If the best match still does not fit the measured data well (a very high χ{sup 2} value), that indicates the true source is not one of the sources in the library. This is still valuable information for decision makers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing ICARUS and REDTOP Software and Hardware: Event Generator Interface Development and Calorimeter Tile Prototype

ICARUS (Imaging Cosmic And Rare Underground Signals) is a liquid argon time projection chamber (LArTPC) detector that pursues the sterile neutrino, which relies on accurate simulations of neutrino-argon interactions. REDTOP (Rare Eta Decays To Observe new Physics) is a proposed low-energy, high-intensity meson factory designed to explore rare $\eta$/$\eta'$ meson decays and probe physics beyond the Standard Model. As a next-generation experiment, this requires both accurate simulations and innovative detector technologies. This project contributes to both ICARUS, from a simulation perspective, and REDTOP, from both a simulation and detection perspective, through the event generation of lepton-nucleon interactions and the physical enhancement of the calorimeter technology within the REDTOP detector. We developed an interface between ACHILLES (A CHIcago Land Lepton Event Simulator), a theory-driven lepton-level event generator, and GENIE, a robust event generator framework used for neutrino physics. By incorporating the precise theoretical cross-section calculations of ACHILLES into the experimental realism of GENIE, the interface allows for improved accuracy of neutrino-nucleon simulations, which can be adapted for the proton beam specifications of the REDTOP meson factory as well as for the ICARUS experiment. In parallel, we developed an improved prototype for the ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) dual-readout calorimeter tiles for the REDTOP detector. To improve the efficiency of the lead-glass tiles trapping Cherenkov light for energy reconstruction and particle identification, we optimized the application of a highly reflective coating. Through viscosity and thickness control, masking, and a custom spray technique, we refined the coating process to reduce surface defects and improve light yield. Together, these efforts strengthen the ICARUS neutrino program and REDTOP's capability of detecting rare decay events.

Visser, Erin [Michigan State U.] (ORCID:0009000184↗

Hammerhead, an ultrahigh resolution ePix camera for wavelength-dispersive spectrometers

Wavelength-dispersive spectrometers (WDS) are often used in synchrotron and FEL applications where high energy resolution (in the order of eV) is important. Increasing WDS energy resolution requires increasing spatial resolution of the detectors in the dispersion direction. The common approaches are not ideal: using strip detectors loses the 2D position sensitivity (important for, e.g., background estimation) and the high counting rate; using pixel detectors with a small pitch results in complex charge sharing behaviour and typically have a small size. Developing pixel detectors with high aspect ratio and a small pitch in the wavelength dispersive direction would be ideal, however, it would require a substantial ASIC development. We present a new approach, with a novel sensor design using rectangular pixels with a high aspect ratio (between strips and pixels, further called “strixels”), and strixel redistribution to match the square pixel arrays of typical ASICs. This results in a sensor area of 17.4 mm × 77 mm, with a fine pitch of 25 µm in the horizontal direction resulting in 3072 columns and 176 rows. The sensors use ePix100 readout ASICs, leveraging their low noise (43 e - , or 180 eV rms). We present results obtained with a Hammerhead ePix100 camera, showing that the small pitch (25 µm) in the dispersion direction maximizes performance for both high and low photon occupancies, resulting in optimal WDS energy resolution. The low noise level at high photon occupancy allows precise photon counting, while at low occupancy, both the energy and the subpixel position can be reconstructed for every photon, allowing an ultrahigh resolution (in the order of 1 µm) in the dispersion direction and rejection of scattered beam and harmonics. Using strixel sensors with redistribution and flip-chip bonding to standard ePix readout ASICs results in ultrahigh position resolution (~1 µm) and low noise in WDS applications, leveraging the advantages of hybrid pixel detectors (high production yield, good availability, relatively inexpensive) while minimizing development complexity through sharing the ASIC, hardware, software and DAQ development with other versions of ePix cameras.

47 OTHER INSTRUMENTATION↗

A Comparison Framework for Reactor Anti-Neutrino Detectors in Near-Field Nuclear Safeguards Applications

Electron anti-neutrino ( e) detectors can support nuclear safeguards, from reactor monitoring to spent fuel characterization. In recent years, the scientific community has developed multiple detector concepts, many of which have been prototyped or deployed for specific measurements by their respective collaborations. However, the diversity of technical approaches, deployment conditions, and analysis techniques complicates direct performance comparison between designs. We have begun development of a simulation framework to compare and evaluate existing and proposed detector designs for nonproliferation applications in a uniform manner. This report demonstrates the intent and capabilities of the framework by evaluating four detector design concepts, calculating generic reactor antineutrino counting sensitivity, and capabilities in a plutonium disposition application example.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation hardness of the low gain avalanche diodes developed by NDL and IHEP in China

This paper presents a study on the radiation hardness of low gain avalanche detector (LGAD) developed by the Novel Device Laboratory (NDL) in Beijing and the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences, in the context of an upgrade project of the ATLAS detector for the high luminosity phase of LHC. NDL LGAD sensors with different layouts, epitaxial resistivity and doping profile were irradiated up to 1.02 × 10 15 n eq /cm 2 by 70 MeV protons at Cyclotron and Radioisotope Center (CYRIC). The timing resolution of NDL LGAD sensors reached 50 ps and the collected charge reached 3 - 4 fC after irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Short-Baseline Near Detector at Fermilab: Input to the European Strategy for Particle Physics 2026 Update

SBND is a 112 ton liquid argon time projection chamber (LArTPC) neutrino detector located 110 meters from the Booster Neutrino Beam (BNB) target at Fermilab. Its main goals include searches for eV-scale sterile neutrinos as part of the Short-Baseline Neutrino (SBN) program, other searches for physics beyond the Standard Model, and precision studies of neutrino-argon interactions. In addition, SBND is providing a platform for LArTPC neutrino detector technology development and is an excellent training ground for the international group of scientists and engineers working towards the upcoming flagship Deep Underground Neutrino Experiment (DUNE). SBND began operation in July 2024, and started collecting stable neutrino beam data in December 2024 with an unprecedented rate of ~7,000 neutrino events per day. During its currently approved operation plans (2024-2027), SBND is expected to accumulate nearly 10 million neutrino interactions. The near detector dataset will be instrumental in testing the sterile neutrino hypothesis with unprecedented sensitivity in SBN and in probing signals of beyond the Standard Model physics. It will also be used to significantly advance our understanding of the physics of neutrino-argon interactions ahead of DUNE. After the planned accelerator restart at Fermilab (2029+), opportunities are being explored to operate SBND in antineutrino mode in order to address the scarcity of antineutrino-argon scattering data, or in a dedicated beam-dump mode to significantly enhance sensitivity to searches for new physics. SBND is an international effort, with approximately 40% of institutions from Europe, contributing to detector construction, commissioning, software development, and data analysis. Continued European involvement and leadership are essential during SBND's operations and analysis phase for both the success of SBND, SBN and its role leading up to DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a fast framing detector for electron microscopy

A high frame rate detector system is described that enables fast real-time data analysis of scanning diffraction experiments in scanning transmission electron microscopy (STEM). This is an end-to-end development that encompasses the data producing detector, data transportation, and real-time processing of data. The detector will consist of a central pixel sensor that is surrounded by annular silicon diodes. Both components of the detector system will synchronously capture data at almost 100 kHz frame rate, which produces an approximately 400 Gb/s data stream. Low-level preprocessing will be implemented in firmware before the data is streamed from the National Center for Electron Microscopy (NCEM) to the National Energy Research Scientific Computing Center (NERSC). Live data processing, before it lands on disk, will happen on the Cori supercomputer and aims to present scientists with prompt experimental feedback. This online analysis will provide rough information of the sample that can be utilized for sample alignment, sample monitoring and verification that the experiment is set up correctly. Only a compressed version of the relevant data is then selected for more in-depth processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

Development of a Faraday cup fast ion loss detector for keV beam ions

The development and testing of a Faraday cup fast-ion loss detector capable of measuring sub 100 keV particles is documented. Such measurement capabilities play an important role in the assessment of particle confinement of nuclear fusion experiments. The detector is manufactured using thin-film deposition techniques, building upon previous work using discrete foils. This new manufacturing method allows the form factor of the sensor to become that of essentially a microchip. Analysis of the diagnostic response is performed using Monte-Carlo particle simulations. These simulations show peaks in the detector response at 40 and 70 keV. The sensor is then tested in a tunable linear accelerator capable of accelerating protons from 20 to 120 keV. Finally, the detector response was found to be well matched to simulations. Improvements to the design to facilitate robustness are discussed.

47 OTHER INSTRUMENTATION↗

The BiPo detector for ultralow radioactivity measurements

The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in {sup 208}Tl and {sup 214}Bi for the SuperNEMO double beta decay source foils. A modular prototype called BiPo-1 with 0.8 m{sup 2} of sensitive surface area has been running in the Modane Underground Laboratory since February 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in {sup 208}Tl. After more than one year of background measurement a surface activity of the scintillators of A({sup 208}Tl) = 1.5 {mu}Bq/m{sup 2} is reported here.Given this level of background, a larger BiPo3 detector having 3.25 m{sup 2} of active surface area, will able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of A({sup 208}Tl)<3-4 {mu}Bq/kg(90% C.L.) with a six month measurement. This detector is actually under construction and will be installed in the Canfranc Underground Laboratory mid 2011.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic bubble chambers and sub-GeV dark matter direct detection

We propose a new application of single molecule magnet crystals: their use as “magnetic bubble chambers” for the direct detection of sub-GeV dark matter. The spins in these macroscopic crystals effectively act as independent nanoscale magnets. When antialigned with an external magnetic field they form metastable states with a relaxation time that can be very long at sufficiently low temperatures. The Zeeman energy stored in this system can be released through localized heating, caused for example by the scattering or absorption of dark matter, resulting in a spin avalanche (or “magnetic deflagration”) that amplifies the effects of the initial heat deposit, enabling detection. Much like the temperature and pressure in a conventional bubble chamber, the temperature and external magnetic field set the detection threshold for a single molecule magnet crystal. Here, we discuss this detector concept for dark matter detection and propose ways to ameliorate backgrounds. If successfully developed, this detector concept can search for hidden photon dark matter in the meV–eV mass range with sensitivities exceeding current bounds by several orders of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large area neutron detector based on Li 6 ionization chamber with integrated body-moderator of high density polyethylene

A detector was developed and funded by DHS to be a lower cost alternative to 3 He detectors. A 6 Li foil-lined ionization chamber was prepared with fill gas at one atmosphere and pulse mode operation. The high-density polyethylene (HOPE) body serves also as a neutron moderator. All electrodes, including high voltage bias supply, are hermetically sealed within the plastic slabs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNM Movement Detection/Radiation Sensors and Advanced Materials Portfolio Review, CdMnTe (CMT) Gamma Ray Detectors

The project goals are: (1) Develop CMT radiation detectors - Demonstrate feasibility (Phase 1 is complete) and Improve material properties and device performance; (2) This project will lead to novel radiation detectors - high detection efficiency, high energy-resolution, ambient-temperature operation, and low production cost; and (3) Such detectors are needed in areas of nonproliferation and national security for detection of SNM. Research highlights are: (1) We achieved our Phase-I goal - Demonstration of CMT detector performance approaching that of CZT detectors; (2) Demonstrated that In-doped CMT is much closer to its anticipated performance as radiation detectors than other alternative materials, TlBr and HgI{sub 2} - Large crystal volumes, 10{sup 10}{Omega}{center_dot}cm, 3 x 10{sup -3}cm{sup 2}/V, and stable response; and (3) Conducted material and device characterization experiments - Detectors: I-V, {mu}{sub e}, ({mu}{tau}){sub e}, internal E fields, energy spectra, and high-resolution x-ray response mapping data and Materials - DLTS, TCT, PL, EPDs, XRD, PCD and IR transmission.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Development of an integrated four-channel fast avalanche-photodiode detector system with nanosecond time resolution

In this paper, a four-channel nanosecond time-resolved avalanche-photodiode (APD) detector system is developed at Beijing Synchrotron Radiation. It uses a single module for signal processing and readout. This integrated system provides better reliability and flexibility for custom improvement. The detector system consists of three parts: (i) four APD sensors, (ii) four fast preamplifiers and (iii) a time-digital-converter (TDC) readout electronics. The C30703FH silicon APD chips fabricated by Excelitas are used as the sensors of the detectors. It has an effective light-sensitive area of 10 × 10 mm 2 and an absorption layer thickness of 110 μ m. A fast preamplifier with a gain of 59 dB and bandwidth of 2 GHz is designed to readout of the weak signal from the C30703FH APD. The TDC is realized by a Spartan-6 field-programmable-gate-array (FPGA) with multiphase method in a resolution of 1ns. The arrival time of all scattering events between two start triggers can be recorded by the TDC. The detector has been used for nuclear resonant scattering study at both Advanced Photon Source and also at Beijing Synchrotron Radiation Facility. Finally, for the X-ray energy of 14.4 keV, the time resolution, the full width of half maximum (FWHM) of the detector (APD sensor + fast amplifier) is 0.86 ns, and the whole detector system (APD sensors + fast amplifiers + TDC readout electronics) achieves a time resolution of 1.4 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Large Area µRWELL Detectors for CLAS12 High Luminosity Upgrade at Jefferson Lab

The high-luminosity upgrade of the CEBAF Large Acceptance Spectrometer (CLAS12) will significantly enhance the physics reach of experiments in Hall B at JLab. However, at the current luminosity of L = 1 × 1035 cm-2 s-1, the reconstruction efficiency of charged particles in the forward region of the CEBAF Large Acceptance Spectrometer (CLAS12) is at the level of 85% and limited in part by the drift chambers inability to handle high occupancy, in the first tracking region (DC-R1) of the Forward Detector. The reconstruction efficiency is expected to drop even lower at higher luminosities with the current tracking technology. Various options under consideration to achieve the desired performance at a higher luminosity of L = 2 × 1035 cm-2 s-1 include the addition of fast tracking layers to complement DC-R1 or the replacement of DC-R1 with a different tracking detector technology altogether. In either case, a novel generation of compact, simple and robust Micro-Pattern Gaseous Detector (MPGD) known as the Resistive Micro-Well detector (µRWELL) is the ideal candidate to satisfy the requirements in terms of timing O (10 ns) and position O (100 µm) resolutions. A large µRWELL prototype, combined with a two-dimensional U-V strip readout layer based on the novel concept of capacitive-sharing approach has been developed as a proof of principle for fast tracking capabilities in the forward region of CLAS12 high-luminosity upgrade. In this talk, we will present the technical aspects of the design choices of the large µRWELL prototype under development and report on the detector assembly process and preliminary performance characteristic tests. We will also discuss the plans for the test and characterization of the prototype in beam during spring 2023 CEBAF run. Finally, we will report on ongoing R&D efforts on small prototypes with the goal to improve rate capability, spatial resolution performance and minimize material thickness.

Gnanvo, Kondo↗

MO-F-CAMPUS-J-03: Development of a Human Brain PET for On-Line Proton Beam-Range Verification

Purpose: To develop a prototype PET for verifying proton beam-range before each fractionated therapy that will enable on-line re-planning proton therapy. Methods: Latest “edge-less” silicon photomultiplier arrays and customized ASIC readout electronics were used to develop PET detectors with depth-of-interaction (DOI) measurement capability. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together to form a large detector panel. Detectors with 1.5×1.5 and 2.0×2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables or PCB board to dedicated ASIC front-end electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition of coincidence events and data transfer. The modular detector and scalable electronics/data acquisition will enable flexible PET system configuration for different imaging geometry. Results: Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ∼18% and 2.8 ns energy and timing resolutions, and around 2–3 mm DOI resolution. A small prototype PET scanner with one detector ring has been built and evaluated, validating the technology and design. A large size detector panel has been fabricated by scaling up from modular detectors. Different designs of resistor and capacitor based signal multiplexing boards were tested and selected based on optimal crystal identification and timing performance. Stackable readout electronics boards and FPGA-based data acquisition boards were developed and tested. A brain PET is under construction. Conclusion: Technology of large-size DOI detector based on SiPM array and advanced readout has been developed. PET imaging performance and initial phantom studies of on-line proton beam-range measurement will be conducted and reported. NIH grant R21CA187717; Cancer Prevention and Research Institute of Texas grant RP120326.

60 APPLIED LIFE SCIENCES↗

Energy calibration of the ProtoDUNE-SP TPC

The single-phase liquid argon prototype at CERN (ProtoDUNE-SP) acts as a validation of the design for the DUNE single-phase far detector. With a total mass of 770 tons, it is the largest monolithic liquid argon single-phase time projection chamber in the world. ProtoDUNE-SP collected test-beam in autumn of 2018 and has been collecting cosmic and special calibration data since the end of 2018. To analyze data from the test-beam, a calibration plan using cosmic muons passing through the detector was developed. An outline of this plan and its impact on the calorimetric measurements of the detector will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗