Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “depth data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Analysis of breathing cracks using vibrations

The influence of half-ellipse-shaped fatigue cracks and machined through-thickness cuts on the impact response of cantilever beam samples were analysed using the Finite Element Method and compared to experimental data for different crack depths. The effect of sample width was analysed for geometries with fatigue cracks (aspect ratio a/c = 0.45) and through-thickness cuts (rectangular cracks). The differences between both types of damage were analysed numerically and experimentally. The effect of sample width was studied and it was found that the behaviour of the cantilever with a fatigue-crack approaches that of the saw cut sample when the fatigue crack reaches the edges of the test piece. Acceleration data were analysed using the Fast Fourier Transform algorithm and Power Density Spectra (PSD) were obtained. For fatigue-cracked samples, harmonics of the frequencies of natural modes of oscillation were found. Analytical modelling was done using a mass-spring-damper system for studying the bilinear behaviour of the stiffness element. Harmonics found were assigned to the breathing behaviour of the crack. The detection threshold using frequency shifts inspection was twice as high as using spectral analysis. This would allow crack detection at half of the fatigue life of the specimen.

42 ENGINEERING↗

Disentangling the Impacts of Microtopography and Shrub Distribution on Snow Depth in a Subarctic Watershed: Toward a Predictive Understanding of Snow Spatial Variability

Snow plays a critical role in carbon cycling, vegetation dynamics, and permafrost hydrology at high latitudes by influencing surface energy exchange. Predicting snow distribution patterns is essential for understanding the evolution of Arctic ecosystems, yet scaling process-level knowledge to landscape predictions remains challenging. Here, we analyze snow depth (2019 and 2022), terrain elevation, and vegetation height from a watershed on the Seward Peninsula, Alaska, to examine how topography and shrubs shape snow redistribution across spatial scales. We find that snow depth is strongly coupled to terrain at scales below ∼60 m but becomes increasingly decoupled at larger scales. The topographic model of snow depth variation, which transforms terrain data to align with these scale-dependent snow patterns, is well correlated with local snow depth variations (linear fit R 2 > 0.5 for 85% of 100-m patches). A machine learning reconstruction of shrub canopy snow trapping reveals a simple exponential relationship between canopy structure and snow accumulation ( R 2 = 0.59), highlighting the combined influence of topography and vegetation on snow distribution. Together, these empirical relationships capture much of the observed snow variability in the watershed ( R 2 = 0.49, root mean square error (RMSE) = 30 cm), though systematic limitations persist in areas of strong scour and at coarser scales where wind-terrain interactions are more complex. These findings provide a framework for more efficient snow depth prediction and offer insights to improve snow-vegetation feedback representation in Earth System Models.

54 ENVIRONMENTAL SCIENCES↗

The Gran Sasso muon puzzle

We carry out a time-series analysis of the combined data from three experiments measuring the cosmic muon flux at the Gran Sasso laboratory, at a depth of 3800 m.w.e. These data, taken by the MACRO, LVD and Borexino experiments, span a period of over 20 years, and correspond to muons with a threshold energy, at sea level, of around 1.3 TeV. We compare the best-fit period and phase of the full muon data set with the combined DAMA/NaI and DAMA/LIBRA data, which spans the same time period, as a test of the hypothesis that the cosmic ray muon flux is responsible for the annual modulation detected by DAMA. We find in the muon data a large-amplitude fluctuation with a period of around one year, and a phase that is incompatible with that of the DAMA modulation at 5.2σ. Aside from this annual variation, the muon data also contains a further significant modulation with a period between 10 and 11 years and a power well above the 99.9% C.L threshold for noise, whose phase corresponds well with the solar cycle: a surprising observation for such high energy muons. We do not see this same period in the stratospheric temperature data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comment on power-law inflation with a dark radiation component

Tram et al. 2016 recently pointed out in [1] that power-law inflation in presence of a dark radiation component may relieve the 3.3 σ tension which exists within standard ΛCDM between the determination of the local value of the Hubble constant by Riess et al. (2016) [2] and the value derived from CMB anisotropy data [3] by the Planck collaboration. In this comment, we simply point out that this interesting proposal does not help in solving the σ{sub 8} tension between the Planck data and, e.g., the weak lensing measurements. Moreover, when the latest constraints on the reionization optical depth obtained from Planck HFI data [4] are included in the analysis, the H {sub 0} tension reappears and this scenario looses appeal.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Energy Survey Year 1 Results: Photometric Data Set for Cosmology

Here, we describe the creation, content, and validation of the Dark Energy Survey (DES) internal year-one cosmology data set, Y1A1 GOLD, in support of upcoming cosmological analyses. The Y1A1 GOLD data set is assembled from multiple epochs of DES imaging and consists of calibrated photometric zeropoints, object catalogs, and ancillary data products -e.g., maps of survey depth and observing conditions, star-galaxy classification, and photometric redshift estimates|that are necessary for accurate cosmological analyses. The Y1A1 GOLD wide-area object catalog consists of 137 million objects detected in coadded images covering 1800 deg 2 in the DES grizY filters. The 10 limiting magnitude for galaxies is g = 23.4, r = 23.2, i = 22.5, z = 21.8, and Y = 20.1. We also performed photometric calibration of Y1A1 GOLD by combining nightly zeropoint solutions with stellar-locus regression, and the absolute calibration accuracy is better than 2% over the survey area. DES Y1A1 GOLD is the largest photometric data set at the achieved depth to date, enabling precise measurements of cosmic acceleration at z ≲1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-cellular force microscopy in single normal and cancer cells

This work investigates the biomechanical properties of sub-cellular structures of breast cells using atomic force microscopy (AFM). The cells are modeled as a triple-layered structure where the Generalized Maxwell model is applied to experimental data from AFM stress-relaxation tests to extract the elastic modulus, the apparent viscosity, and the relaxation time of sub-cellular structures. The triple-layered modeling results allow for determination and comparison of the biomechanical properties of the three major sub-cellular structures between normal and cancerous cells: the up plasma membrane/actin cortex, the mid cytoplasm/nucleus, and the low nuclear/integrin sub-domains. The results reveal that the sub-domains become stiffer and significantly more viscous with depth, regardless of cell type. In addition, there is a decreasing trend in the average elastic modulus and apparent viscosity of the all corresponding sub-cellular structures from normal to cancerous cells, which becomes most remarkable in the deeper sub-domain. The presented modeling in this work constitutes a unique AFM-based experimental framework to study the biomechanics of sub-cellular structures. - Highlights: • The cells are modeled as a triple-layered structure using Generalized Maxwell model. • The sub-domains include membrane/cortex, cytoplasm/nucleus, and nuclear/integrin. • Biomechanics of corresponding sub-domains are compared among normal and cancer cells. • Viscoelasticity of sub-domains show a decreasing trend from normal to cancer cells. • The decreasing trend becomes most significant in the deeper sub-domain.

60 APPLIED LIFE SCIENCES↗

The effect of spiral arms on the Sérsic photometry of galaxies

The Sérsic profile is a widely used model for describing the surface brightness distribution of galaxies. Spiral galaxies, however, are qualitatively different from a Sérsic model. Aims. The goal of this study is to assess how accurately the total flux and half-light radius of a galaxy with spiral arms can be recovered when fitted with a Sérsic profile. Methods. I selected a sample of bulge-dominated galaxies with spiral arms. Using photometric data from the Hyper Suprime-Cam survey, I estimated the contribution of the spiral arms to their total flux. Then I generated simulated images of galaxies with similar characteristics, fitted them with a Sérsic model, and quantified the error on the determination of the total flux and half-light radius. Results. Spiral arms can introduce biases on the photometry of galaxies in a way that depends on the underlying smooth surface brightness profile, the location of the arms, and the depth of the photometric data. A set of spiral arms accounting for 10% of the flux of a bulge-dominated galaxy typically causes the total flux and the half-light radius to be overestimated by 15% and 30%, respectively. This bias, however, is much smaller if the galaxy is disk-dominated. Conclusions. Galaxies with a prominent bulge and a non-zero contribution from spiral arms are the most susceptible to biases in the total flux and half-light radius when fitted with a Sérsic profile. If photometric measurements with high accuracy are required, then measurements over finite apertures are to be preferred over global estimates of the flux.

79 ASTRONOMY AND ASTROPHYSICS↗

Utah FORGE: Phase 3 Ground Water Level Monitoring Data

Groundwater data around the Utah FORGE site has been collected to determine the piezometric levels and compositional variability. Field measurements in 2020 are designed to obtain and survey new groundwater wells that have been drilled on the distal periphery of the Utah FORGE project area. The spreadsheet included in this submission contains ground water level data from the Utah FORGE site as monitored from wells WOW-2 and WOW-3. The well locations are also provided as UTM, Zone 12, NAD83 coordinates.

15 GEOTHERMAL ENERGY↗

SU-D-207-07: Implementation of Full/half Bowtie Filter Model in a Commercial Treatment Planning System for Kilovoltage X-Ray Imaging Dose Estimation

Purpose: To implement full/half bowtie filter models in a commercial treatment planning system (TPS) to calculate kilovoltage (kV) x-ray imaging dose of Varian On-Board Imager (OBI) cone beam CT (CBCT) system. Methods: Full/half bowtie filters of Varian OBI were created as compensator models in Pinnacle TPS (version 9.6) using Matlab software (version 2011a). The profiles of both bowtie filters were acquired from the manufacturer, imported into the Matlab system and hard coded in binary file format. A Pinnacle script was written to import each bowtie filter data into a Pinnacle treatment plan as a compensator. A kV x-ray beam model without including the compensator model was commissioned per each bowtie filter setting based on percent depth dose and lateral profile data acquired from Monte Carlo simulations. To validate the bowtie filter models, a rectangular water phantom was generated in the planning system and an anterior/posterior beam with each bowtie filter was created. Using the Pinnacle script, each bowtie filter compensator was added to the treatment plan. Lateral profile at the depth of 3cm and percent depth dose were measured using an ion chamber and compared with the data extracted from the treatment plans. Results: The kV x-ray beams for both full and half bowtie filter have been modeled in a commercial TPS. The difference of lateral and depth dose profiles between dose calculations and ion chamber measurements were within 6%. Conclusion: Both full/half bowtie filter models provide reasonable results in kV x-ray dose calculations in the water phantom. This study demonstrates the possibility of using a model-based treatment planning system to calculate the kV imaging dose for both full and half bowtie filter modes. Further study is to be performed to evaluate the models in clinical situations.

60 APPLIED LIFE SCIENCES↗

Three-dimensional induced polarization data inversion for complex resistivity

The conductive and capacitive material properties of the subsurface can be quantified through the frequency-dependent complex resistivity. However, the routine three-dimensional (3D) interpretation of voluminous induced polarization (IP) data sets still poses a challenge due to large computational demands and solution nonuniqueness. We have developed a flexible methodology for 3D (spectral) IP data inversion. Our inversion algorithm is adapted from a frequency-domain electromagnetic (EM) inversion method primarily developed for large-scale hydrocarbon and geothermal energy exploration purposes. The method has proven to be efficient by implementing the nonlinear conjugate gradient method with hierarchical parallelism and by using an optimal finite-difference forward modeling mesh design scheme. The method allows for a large range of survey scales, providing a tool for both exploration and environmental applications. We experimented with an image focusing technique to improve the poor depth resolution of surface data sets with small survey spreads. The algorithm's underlying forward modeling operator properly accounts for EM coupling effects; thus, traditionally used EM coupling correction procedures are not needed. The methodology was applied to both synthetic and field data. We tested the benefit of directly inverting EM coupling contaminated data using a synthetic large-scale exploration data set. Afterward, we further tested the monitoring capability of our method by inverting time-lapse data from an environmental remediation experiment near Rifle, Colorado. Similar trends observed in both our solution and another 2D inversion were in accordance with previous findings about the IP effects due to subsurface microbial activity.

15 GEOTHERMAL ENERGY↗

iButton snow-ground interface temperature measurements in Los Alamos, New Mexico from 2023-2024

Snow/ground interface temperature measurements were collected at two sites in Los Alamos, New Mexico. Data were collected from November 29, 2023 to April 8, 2024 using iButton Link DS1921G-F5# Thermochron miniature temperature sensors (https://www.ibuttonlink.com/products/ds1921g). These sensors are a cost-efficient way to collect snowpack temperatures at a higher spatial resolution than what is normally achieved. iButton data were collected every 3 hours from a total of 19 iButtons. iButtons were placed in pairs, with one iButton placed at the ground surface and another buried 1 - 5 cm below the ground surface. One buried iButton did not successfully collect data, and therefore was excluded from this dataset. Data were collected throughout the snow cover season so that snowpack characteristics could be derived using the temperature data. Specifically, this dataset was used as a validation source for a novel machine learning approach to estimating snow depth (see related publication). Sensors were placed in areas with bare ground or minimal grass coverage, located away from any large vegetation. At Site A (TA51), manual snow depths were collected as validation data. These measurements were taken next to iButtons periodically throughout the winter, and notes on other precipitation types were also recorded. At Site B (TA6 Meteorological Station), a nearby sensor collected snow depths throughout the winter. This dataset contains one *.csv file of snow/ground interface temperatures at two sites, one *.csv file of manually collected snow depths, and one *.kml file of sensor locations. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic) was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy’s Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy’s Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Deep Bed Iodine Sorbent Testing FY 2011 Report

Nuclear fission results in the production of fission products (FPs) and activation products that increasingly interfere with the fission process as their concentrations increase. Some of these fission and activation products tend to evolve in gaseous species during used nuclear fuel reprocessing. Analyses have shown that I129, due to its radioactivity, high potential mobility in the environment, and high longevity (half life of 15.7 million years), can require control efficiencies of up to 1,000x or higher to meet regulatory emission limits. Deep-bed iodine sorption testing has been done to evaluate the performance of solid sorbents for capturing iodine in off-gas streams from nuclear fuel reprocessing plants. The objectives of the FY 2011 deep bed iodine sorbent testing are: (1) Evaluate sorbents for iodine capture under various conditions of gas compositions and operating temperature (determine sorption efficiencies, capacities, and mass transfer zone depths); and (2) Generate data for dynamic iodine sorption modeling. Three tests performed this fiscal year on silver zeolite light phase (AgZ-LP) sorbent are reported here. Additional tests are still in progress and can be reported in a revision of this report or a future report. Testing was somewhat delayed and limited this year due to initial activities to address some questions of prior testing, and due to a period of maintenance for the on-line GC. Each test consisted of (a) flowing a synthetic blend of gases designed to be similar to an aqueous dissolver off-gas stream over the sorbent contained in three separate bed segments in series, (b) measuring each bed inlet and outlet gas concentrations of iodine and methyl iodide (the two surrogates of iodine gas species considered most representative of iodine species expected in dissolver off-gas), (c) operating for a long enough time to achieve breakthrough of the iodine species from at least one (preferably the first two) bed segments, and (d) post-test purging with pure N 2 to drive loosely or physisorbed iodine species off of the sorbent. Post-test calculations determine the control efficiencies for each bed, iodine loadings on the sorbent, and mass transfer zone depths. Portions of the iodine-laden sorbent from the first bed of two of the tests have been shipped to SNL for waste form studies. Over the past three years, we have explored a full range of inlet iodine and methyl iodide concentrations ranging from ~100 ppb to ~100 ppm levels, and shown adequate control efficiencies within a bed depth as shallow as 2 inches for lower concentrations and 4 inches for higher concentrations, for the AgZ-type sorbents. We are now performing a limited number of tests in the NC-77 sorbent from SNL. Then we plan to continue to (a) fill in data gaps needed for isotherms and dynamic sorbent modeling, and (b) test the performance of additional sorbents under development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-T-21: A Novel Beam-Light View, Collimating Applicator for HDR Ocular Conjunctiva Brachytherapy-Treatments

Purpose: We propose the use of a HDR X-ray source collimator to apply a conformal, relatively small, radiation suitable for a single fraction with short delivery time. In addition, this technique can be applied using a radioactive source. Methods: We have built a stainless steel 1.5 mm thick applicator, to accommodate the needle applicator of the Intra-Beam X-ray source. Additional cavity is created in the applicator to allow the hosting/nesting/positioning of a LED diode. This LED is allowing a pre-irradiation beam marking on the tissue. The visible light emitted from the opening of the collimated applicator will delineate/verify the aperture of the kV beam to be applied, as well as serve as distance indicator and will assist in the determination of dose to be delivered. For the evaluation of the collimated spatial dose distribution we have performed water tank measurements using (IBA Dosimetry) with a 0.4 cc ion chamber (IBA Dosimetry). We have scanned a two dimensional array with 1mm pitch in depth and 0.3 mm step size laterally. Additional verifications were conducted using Gaf-Chromic film for PDD measurements and Optical Stimulated Luminescence Dosimetry (OSLD, Landauer inc.) for absolute dosimetry. Results: The collimated applicator enables a conformal irradiated cross-section of about 3 mm square at the applicator surface was used in this study. A 180 seconds of 50 kVp delivery yielded 29 Gy, 20.6 Gy and 14.5 Gy at 5, 10 and 15 mm depths respectively. These results are in good agreement with the needle applicator depth dose curve published data. Conclusion: We have demonstrated the feasibility of focal HDR brachytherapy for conjunctival and ocular tumors, using the Intra-Beam needle applicator with in-house developed collimator. The delivery time was found to be several minutes- suitable for an intra-operative procedure and will allow dose fractionation deliveries.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

X-ray phase imaging with a paper analyzer

We present a simple x-ray phase imaging method that utilizes the sample-induced distortion of a high contrast random intensity pattern to quantitatively retrieve the two-dimensional phase map at the exit surface of a coherently illuminated sample. This reference pattern is created by placing a sheet of sandpaper in the x-ray beam, with the sample-induced distortion observed after propagation to the detector, a meter downstream. Correlation analysis comparing a single ''sample and sandpaper'' image to a reference ''sandpaper only'' image produces two sensitive differential phase contrast images, giving the sample phase gradient in vertical and horizontal directions. These images are then integrated to recover the projected phase depth of the sample. The simple experimental set-up, retention of flux, and the need for only a single sample image per reconstruction suggest that this method is of value in imaging a range of dynamic processes at both synchrotron and laboratory x-ray sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-service Inspection of Radioactive Waste Tanks at the Savannah River Site – 15410

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is approximately 1.70 millimeter deep (i.e., less than 10% through-wall). Improvements to the inspection program were recently instituted to provide additional confidence in the degradation rates. Thickness measurements from a single vertical strip along the accessible height of the primary tank have been used as a baseline to compare historical measurements. Changes in wall thickness and pit depths along this vertical strip are utilized to estimate the rate of corrosion degradation. An independent review of the ISI program methodology, results, and path forward was held in August 2009. The review recommended statistical sampling of the tanks to improve the confidence of the single strip inspection program. The statistical sampling plan required that SRS increase the amount of area scanned per tank. Therefore, in addition to the baseline vertical strip that is obtained for historical comparisons, four additional randomly selected vertical strips are inspected. To date, a total of 104 independent vertical strips along the height of the primary tank have been completed. A statistical analysis of the data indicates that at this coverage level there is a 99.5% confidence level that one of the worst 5% of all the vertical strips was inspected. That is, there is a relatively high likelihood that the SRS inspection program has covered one of the most corroded areas of any of the Type III/IIIA waste tanks. These data further support the conclusion that there are no significant indications of wall thinning or pitting. Random sampling will continue to increase the confidence that one of the worst 5% has been inspected. In order to obtain the additional vertical strips, and minimize budget and schedule impacts, data collection speed for the UT system was optimized. Prior to 2009, the system collected data at a rate of 32 square centimeters per minute. The scan rate was increased to 129 - 160 square centimeters per minute by increasing the scanner step and pixel sizes in the data acquisition set-up. Laboratory testing was utilized to optimize the scan index/pixel size such that the requirements for wall thinning and pit detection were still maintained. SRS continues to evaluate improvements to ultrasonic equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A quantitative method to determine the region not influenced by injected interstitial and surface effects during void swelling in ion-irradiated metals

We propose and demonstrate a microstructurally-based experimental method to quantitively determine the depth regions in self-ion-irradiated metals that are affected by the injected interstitial effect and various surface effects, focusing on the choice of safe analysis zones to minimize the impact of these phenomena. The goal is to define the depth ranges where extracted data can be confidently applied to ion-neutron correlations for reactor application. Since ion energies in the range of 1–5 MeV are most frequently employed by the radiation effects community, irradiations were conducted at four energies in this range, all proceeding at 475 °C. The experiment was conducted on relatively pure single crystal iron to focus only on physical phenomena, avoiding the influence of possibly confounding chemical or segregation processes. Care was also taken to minimize the influence of other physical factors such as crystalline orientation. It was shown that, at 475 °C, ion energies of ≤1 MeV were too shallow in penetration and did not yield a safe depth range, but irradiations at 2.5 MeV and above yielded useful safe zones with predicted swelling behavior becoming independent of ion energy. The surface-affected zone width was found to be roughly twice that of the void-denuded zone width and to be independent of accumulated displacement dose. The largest injected-interstitial effect arises from the injected interstitial depression of void nucleation and growth. The interstitial-affected region starts at about one half of the projected range and does not show any “spreading” of its influence in depth as the peak damage level increases from 50 to 100 dpa. This study provides some confidence that enhances the credibility of ion simulation when applied to prediction of void swelling in neutron environments.

36 MATERIALS SCIENCE↗