Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Transportation technology: Earth-to-orbit propulsion

The topics presented are covered in viewgraph form and include the following: (1) sensor autodiagnosis and autocalibration; (2) autodiagnostic and autocalibration program; (3) plume diagnostics; (4) plume diagnostics program; (5) failure modeling; (6) mass data storage and retrieval; (7) fiber optic instrumentation bus; (8) model based diagnostics; (9) safety monitoring system (SMS); (10) control and real time diagnostics; (11) current intelligent controls program; (12) augumented intelligent controls program; (13) current real time diagnostics program; (14) augumented RT diagnostics program; and (15) control and diagnostic system hardware.

Gorland, S.↗

Improved Transient Stability Analysis of Multi-loop Droop-Controlled Grid Forming Inverters with Current Reference Limiter

Grid-forming control is regarded as a promising technology for achieving high levels of renewable energy integration in future power grids. To fulfill this role, grid-forming devices is expected to possess fault ride through capability. This paper focuses on the transient stability of a droop control-based grid-forming inverter that utilizes current reference saturation as a current limiting strategy. The objective of this work is to investigate the fault recovery process of the grid-forming inverter and analyze the criterion for transitioning the inverter out of the current limiting mode. The theoretical analysis in this study is validated through time-domain simulations, which compare the results obtained using the circuit current limiting method and the d-axis priority-based current limiting method. Various operational conditions are considered to comprehensively evaluate the performance of the grid-forming inverter during a three-phase short circuit scenario. The simulation results confirm the effectiveness of the proposed theoretical approach.

Lyu, Xue↗

Current limiting remote power control module

The power source for the Space Station Freedom will be fully utilized nearly all of the time. As such, any loads on the system will need to operate within expected limits. Should any load draw an inordinate amount of power, the bus voltage for the system may sag and disrupt the operation of other loads. To protect the bus and loads some type of power interface between the bus and each load must be provided. This interface is most crucial when load faults occur. A possible system configuration is presented. The proposed interface is the Current Limiting Remote Power Controller (CL-RPC). Such an interface should provide the following power functions: limit overloading and resulting undervoltage; prevent catastrophic failure and still provide for redundancy management within the load; minimize cable heating; and provide accurate current measurement. A functional block diagram of the power processing stage of a CL-RPC is included. There are four functions that drive the circuit design: rate control of current; current sensing; the variable conductance switch (VCS) technology; and the algorithm used for current limiting. Each function is discussed separately.

Hopkins, Douglas C.↗

Development of Electronic Load Controllers for Free-Piston Stirling Convertors Aided by Stirling Simulation Model

The free-piston Stirling convertor end-to-end modeling effort at the NASA Glenn Research Center has produced a software-based test bed in which free-piston Stirling convertors can be simulated and evaluated. The simulation model includes all the components of the convertor: the Stirling cycle engine, heat source, linear alternator, controller, and load. So far, it has been used in evaluating the performance of electronic controller designs. Three different controller design concepts were simulated using the model: 1) Controllers with parasitic direct current loading. 2) Controllers with parasitic alternating current loading. 3) Controllers that maintain a reference current. The free-piston Stirling convertor is an electromechanical device that operates at resonance. It is the function of the electronic load controller to ensure that the electrical load seen by the machine is always great enough to keep the amplitude of the piston and alternator oscillation at the rated value. This is done by regulating the load on the output bus. The controller monitors the instantaneous voltage, regulating it by switching loads called parasitic loads onto the bus whenever the bus voltage is too high and removing them whenever the voltage is too low. In the first type of controller, the monitor-ing and switching are done on the direct-current (dc) bus. In the second type, the alternating current bus is used. The model allows designers to test a controller concept before investing time in hardware. The simulation code used to develop the model also offers detailed models of digital and analog electronic components so that the resulting designs are realistic enough to translate directly into hardware circuits.

Regan, Timothy F.↗

Space station contamination control study: Internal combustion, phase 1

Contamination inside Space Station modules was studied to determine the best methods of controlling contamination. The work was conducted in five tasks that identified existing contamination control requirements, analyzed contamination levels, developed outgassing specification for materials, wrote a contamination control plan, and evaluated current materials of offgassing tests used by NASA. It is concluded that current contamination control methods can be made to function on the Space Station for up to 1000 days, but that current methods are deficient for periods longer than about 1000 days.

Ruggeri, Robert T.↗

Distributed control for COFS 1

An overview is given of the work being done at NASA LaRC on developing the Control of Flexible Structures (COFS) 1 Flight Experiment Baseline Control Law. This control law currently evolving to a generic control system software package designed to supply many, but not all, guest investigators. A system simulator is also described. It is currently being developed for COFS-1 and will be used to develop the Baseline Control Law and to evaluate guest investigator control schemes. It will be available for use whether or not control schemes fall into the category of the Baseline Control Law. First, the hardware configuration for control experiments is described. This is followed by a description of the simulation software. Open-loop sinusoid excitation time histories are next presented both with and without a local controller for the Linear DC Motor (LDCM) actuators currently planned for the flight. The generic control law follows and algorithm processing requirements are cited for a nominal case of interest. Finally, a closed-loop simulation study is presented, and the state of the work is summarized in the concluding remarks.

Montgomery, R. C.↗

Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

Soltis, James V.↗

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters↗

Hepatitis C virus NS3/4A inhibitors and other drug-like compounds as covalent binders of SARS-CoV-2 main protease

Severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2), which causes coronavirus disease 2019 (COVID-19), threatens global public health. The world needs rapid development of new antivirals and vaccines to control the current pandemic and to control the spread of the variants. Among the proteins synthesized by the SARS-CoV-2 genome, main protease (M pro also known as 3CL pro ) is a primary drug target, due to its essential role in maturation of the viral polyproteins. In this study, we provide crystallographic evidence, along with some binding assay data, that three clinically approved anti hepatitis C virus drugs and two other drug-like compounds covalently bind to the M pro Cys145 catalytic residue in the active site. Also, molecular docking studies can provide additional insight for the design of new antiviral inhibitors for SARS-CoV-2 using these drugs as lead compounds. One might consider derivatives of these lead compounds with higher affinity to the M pro as potential COVID-19 therapeutics for further testing and possibly clinical trials.

36 MATERIALS SCIENCE↗

Technologies for providing secure emergency power control of high voltage direct current transmission system

Technologies for providing secure emergency power control of a high voltage direct current transmission (HVDC) system include a controller. The controller includes circuitry configured to receive status data indicative of a present physical status of a power system. The circuitry is also configured to obtain an emergency power control command triggered by a remote source. The emergency power control command is to be executed by an HVDC transmission system of the power system. Further, the circuitry is configured to determine, as a function of the status data, whether the emergency power control command is consistent with the present physical status of the power system and block, in response to a determination that the emergency power control command is not consistent with the present physical status of the power system, execution of the emergency power control command by the HVDC transmission system.

Pan, Jiuping↗

Enabling Grid-Forming Control Under Unbalanced Conditions

Standalone microgrids often experience unbalanced loading and faults, which can cause grid-forming control designed for balanced conditions to produce oscillatory responses. To address this issue, a compact time-domain transformation appropriate for inverter control is proposed, allowing the conversion of unbalanced three-phase signals to positive and negative synchronous reference frames. This transformation supports the development of a grid-forming control with fault ride-through, featuring frequency and voltage droop controllers and nested current and voltage control loops that seamlessly integrate an enhanced current limiter. The effectiveness of the proposed control and transformation is demonstrated through analytical results and electromagnetic transient simulation.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Actuation of Deformable Mirrors Using Laser Controlled Pistons

Current deformable mirrors used for adaptive optics employ many actuators to adjust the mirror in order to compensate for optical irregularities. These mechanical actuators, which can number in the hundreds for a given mirror, require a significant amount of electrical wires in order to be controlled. The objective of this research is to implement a different type of actuator that can be controlled without the use of wires. The actuator developed employs a laser to quickly heat and expand the air in a closed "cell." When the air expands, it pushes a membrane that causes the mirror to move. Creating an array of these cells, and scanning them with a laser can control a deformable mirror. Testing showed that a single cell with a 5-mm diameter and 10-mm length can deflect a membrane of aluminized mylar in excess of our minimum requirement of 20 microns. These cells can now be assembled in a 5x5 matrix and attached to many small Mirrors. An electro-mechanical scanning assembly can be used to aim the laser directly onto individual cells causing the mirror at that location to move.

Scott, Charles E.↗

Actuation of Deformable Mirrors Using Laser Controlled Pistons

Current deformable mirrors used for adaptive optics employ many actuators to adjust the mirror in order to compensate for optical irregularities. These mechanical actuators, which can number in the hundreds for a given mirror, require a significant amount of electrical wires in order to be controlled. The objective of this research is to implement a different type of actuator that can be controlled without the use of wires. The actuator developed employs a laser to quickly heat and expand the air in a closed 'cell'. When the air expands, it pushes a membrane that causes the mirror to move. Creating an array of these cells, and scanning them with a laser can control a deformable mirror. Testing showed that a single cell with a 5 mm diameter and 10 mm in length can deflect a membrane of aluminized Mylar in excess of our minimum requirement of 20 microns. These cells can now be assembled in a 5 x 5 matrix and attached to many small mirrors. An electro-mechanical scanning assembly can be used to aim the laser directly onto individual cells causing the mirror at that location to move.

deformable mirrors↗

Supercritical CO2 Cleaning System for Planetary Protection and Contamination Control Applications

Current spacecraft-compatible cleaning protocols involve a vapor degreaser, liquid sonication, and alcohol wiping. These methods are not very effective in removing live and dead microbes from spacecraft piece parts of slightly complicated geometry, such as tubing and loosely fitted nuts and bolts. Contamination control practices are traditionally focused on cleaning and monitoring of particulate and oily residual. Vapor degreaser and outgassing bakeout have not been proven to be effective in removing some less volatile, hydrophilic biomolecules of significant relevance to life detection. A precision cleaning technology was developed using supercritical CO2 (SCC). SCC is used as both solvent and carrier for removing organic and particulate contaminants. Supercritical fluid, like SCC, is characterized by physical and thermal properties that are between those of the pure liquid and gas phases. The fluid density is a function of the temperature and pressure. Its solvating power can be adjusted by changing the pressure or temperature, or adding a secondary solvent such as alcohol or water. Unlike a regular organic solvent, SCC has higher diffusivities, lower viscosity, and lower surface tension. It readily penetrates porous and fibrous solids and can reach hard-to-reach surfaces of the parts with complex geometry. Importantly, the CO2 solvent does not leave any residue. The results using this new cleaning device demonstrated that both supercritical CO2 with 5% water as a co-solvent can achieve cleanliness levels of 0.01 mg/cm2 or less for contaminants of a wide range of hydrophobicities. Experiments under the same conditions using compressed Martian air mix, which consists of 95% CO2, produced similar cleaning effectiveness on the hydrophobic compounds. The main components of the SCC cleaning system are a high-pressure cleaning vessel, a boil-off vessel located downstream from the cleaning vessel, a syringe-type high-pressure pump, a heat exchanger, and a back pressure regulator (BPR). After soaking the parts to be cleaned in the clean vessel for a period, the CO2 with contaminants is flushed out of the cleaning vessel using fresh CO2 in a first-in-first-out (FIFO) method. The contaminants are either precipitating out in the boil-off container or being trapped in a filter subsystem. The parts to be cleaned are secured in a basket inside and can be rotated up to 1,400 rpm by a magnetic drive. The fluid flows within the vessel generate tangential forces on the parts surfaces, enhancing the cleaning effectiveness and shortening the soaking time. During the FIFO flushing, the pump subsystem pushes fresh CO2 into the cleaning vessel at a constant flow rate between 0.01 and 200 mL/min, while the BPR regulates the pressure in the cleaning vessel to within 0.1 bar by controlling the needle position in an outlet valve. The fresh CO2 gas flows through the heat exchanger at a given temperature before entering the cleaning vessel. A platinum resistance thermometer (PRT) reads the cleaning vessel interior temperature that can be controlled to within 0.1 K. As a result, cleaning vessel temperature remains constant during the FIFO flushing. There is no change in solvent power during FIFO flushing since both temperature and pressure inside the cleaning vessel remain unchanged, thus minimizing contaminants left behind. During decompression, both temperature and pressure are strictly controlled to prevent bubbles from generating in the cleaning vessel that could stir up the contaminants that sank to the bottom by gravity.

Lin, Ying↗

Frequency Response Improvement in a Standalone Small Hydropower Plant Using Battery Storage

This paper proposes a control architecture for frequency, current, and voltage control that facilitates using battery storage to improve the response of standalone small hydropower plants. The frequency controller uses rate-of-change of frequency and frequency-Watt-based generations to produce active power commands. The distinctive feature of the controller design is that it nicely integrates response to frequency change with constraints on frequency and state of battery to enable power injections. The current and voltage control scheme allows incorporating the frequency controller. The distinctive feature of this controller is that it incorporates a bounded integral control strategy that guarantees stability. Results on the stability of the hydropower plant with proposed scheme are presented and robust ways to choose the controller gains are investigated via root locus analysis. In conclusion, simulations performed show that: the hydropower plant response is significantly improved with battery storage using the proposed scheme; the load carrying capability of the hydropower plant is significantly improved with battery storage; the proposed scheme has the capability to recharge the battery; and the proposed control scheme gives improved performance.

13 HYDRO ENERGY↗

Current Level of Mission Control Automation at NASA/Goddard Space Flight Center

NASA is particularly concerned with reducing mission operations costs through increased automation. This paper examines the operations procedures within NASA Mission Control Centers in order to uncover the level of automation that currently exists within them. Based on an assessment of mission operations procedures within three representative control centers, this paper recommends specific areas where there is potential for mission cost reduction through increased automation.

Maks, Lori↗