Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

SU-G-IeP4-03: Cone Beam X-Ray Luminescence Computed Tomography Based On Generalized Gaussian Markov Random Field

Purpose: Cone beam X-ray luminescence computed tomography (CB-XLCT), which aims to achieve molecular and functional imaging by X-rays, has recently been proposed as a new imaging modality. However, the inverse problem of CB-XLCT is seriously ill-conditioned, hindering us to achieve good image quality. In this work, a novel reconstruction method based on Bayesian theory is proposed to tackle this problem Methods: Bayesian theory provides a natural framework for utilizing various kinds of available prior information to improve the reconstruction image quality. A generalized Gaussian Markov random field (GGMRF) model is proposed here to construct the prior model of the Bayesian theory. The most important feature of GGMRF model is the adjustable shape parameter p, which can be continuously adjusted from 1 to 2. The reconstruction image tends to have more edge-preserving property when p is slide to 1, while having more noise tolerance property when p is slide to 2, just like the behavior of L1 and L2 regularization methods, respectively. The proposed method provides a flexible regularization framework to adapt to a wide range of applications. Results: Numerical simulations were implemented to test the performance of the proposed method. The Digimouse atlas were employed to construct a three-dimensional mouse model, and two small cylinders were placed inside to serve as the targets. Reconstruction results show that the proposed method tends to obtain better spatial resolution with a smaller shape parameter, while better signal-to-noise image with a larger shape parameter. Quantitative indexes, contrast-to-noise ratio (CNR) and full-width at half-maximum (FWHM), were used to assess the performance of the proposed method, and confirmed its effectiveness in CB-XLCT reconstruction. Conclusion: A novel reconstruction method for CB-XLCT is proposed based on GGMRF model, which enables an adjustable performance tradeoff between L1 and L2 regularization methods. Numerical simulations were conducted to demonstrate its performance.

60 APPLIED LIFE SCIENCES↗

Digital Radiography and Computed Tomography Project -- Fully Integrated Linear Detector ArrayStatus Report

The field-portable Digital Radiography and Computed Tomography (DRCT) x-ray inspection systems developed for the Project Manager for NonStockpile Chemical Materiel (PMNSCM) over the past 13 years have used linear diode detector arrays from two manufacturers; Thomson and Thales. These two manufacturers no longer produce this type of detector. In the interest of insuring the long term viability of the portable DRCT single munitions inspection systems and to improve the imaging capabilities, this project has been investigating improved, commercially available detectors. During FY-10, detectors were evaluated and one in particular, manufactured by Detection Technologies (DT), Inc, was acquired for possible integration into the DRCT systems. The remainder of this report describes the work performed in FY-11 to complete evaluations and fully integrate the detector onto a representative DRCT platform.

47 OTHER INSTRUMENTATION↗

Demonstration of Emitted-Neutron Computed Tomography to Quantify Nuclear Materials

In this document, we report demonstration of emitted-neutron computed tomography using fast fission neutrons to infer the geometry of sources of special nuclear material (SNM). The imaging system employed in the demonstration is based on a newly constructed array of pixelated neutron detectors that are suitable for arrangement in a close-packed imaging array and whose active volume consists of liquid scintillator EJ-309 which allows neutron-gamma discrimination via pulse shape to enable essentially pure fast-neutron imaging. The system is capable of high quality fast-neutron imaging where tomographic reconstruction of slices through an object resolves neutron sources similar in dimension to a fuel pellet, or about 1 cm. During measurements of Pu MOX fuel rodlet arrays in soup cans at the INL ZPPR facility, the position of a partial defect of a single rodlet containing Pu replaced by one containing depleted uranium (DU) was detected.

Hausladen, Paul A.↗

Computed Tomography Scanning and Geophysical Measurements of the Rogersville Shale from the Smith #1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize a core from the Rogersville Shale. This sample was taken from a vertical well, the Jay P. Smith #1 well (47-099-1572), drilled in Wayne County, West Virginia by the Exxon Company in the Elmwood Prospect. The core is comprised primarily of the Rogersville Shale from depths of 11,135 to 11,200.5 ft. This unit is a potential Cambrian oil/gas target, making it of recent interest to multiple groups. The core was provided by the West Virginia Geologic and Economic Survey (WVGES). The primary impetus of this work is a collaboration between WVGES and NETL to characterize core from multiple wells to better understand the structure and variation of key formations in West Virginia (e.g. Crandall et al., 2018a,b). As part of this effort, bulk scans of core were obtained from the Smith #1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/roger-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provides both a macro and micro description of the core that is relevant for many subsurface energy-related examinations that have traditionally been performed at NETL.

04 OIL SHALES AND TAR SANDS↗

Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Armstrong #1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from the Marcellus Formation. The core is from a vertical well (Armstrong #1) drilled in Taylor County, West Virginia by the Petroleum Development Corporation (7,545 to 7,783.4 ft). Core was provided by Phillip Dinterman, West Virginia Geologic and Economical Survey (WVGES) and Tim Carr and Keithan Martin, West Virginia University (WVU). The primary impetus of this work is a collaboration between NETL, WVGES, and WVU to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica Shale formations. As part of this effort, bulk scans of core were obtained from the Armstrong #1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/armstrong-well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of the Salina Formation from the #36 Brine Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core of the Salina Formation from a vertical well (Brine Well #36) from Marshall County, West Virginia at a depth of 6,555.6 to 6,719.5 ft. The primary impetus of this work is a collaboration between West Virginia Geological and Economic Survey (WVGES) and NETL to characterize core from multiple wells to better understand the key formations in West Virginia. As part of this effort, bulk scans of core were obtained from the Brine Well #36, provided by the WVGES. This report, and the associated scans generated, provide detailed datasets not typically available for researchers to analyze.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Enhanced Geothermal Systems (EGS) Collab SURF Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from 8 wells from the Enhanced Geothermal Systems (EGS) Collab project located in the Sanford Underground Research Facility’s (SURF) 4850 level. The work in this report falls in Experiment 1 in a three-phase experiment, with the primary purpose to increase understanding of hydraulic fracturing. The primary impetus of this work is a collaboration between U.S. Department of Energy (DOE) and the EGS Collab. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/surf-collab-core. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in the core, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of State 16-2 Well in the Paradox Basin

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Paradox Basin core from Grand County, Utah. The primary impetus of this work is a collaboration between the U.S. Department of Energy (DOE), the Utah Geological Survey, the University of Utah, and Zephyr Energy to characterize and make publicly available core information from the Cane Creek interval of the Paradox Basin. This stratigraphic well and the core data produced in this report will aid in understanding the structural complexities of the Cane Creek interval and its production potential.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Patterson #5-25 Well in Western Kansas

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) site in Morgantown, West Virginia, were used to characterize core from the Patterson Field site. This core came from a vertical well (Patterson #5-25 well) that was obtained as part of the U.S. Department of Energy (DOE) sponsored Integrated Midcontinental Stacked Carbon Storage Hub. The primary impetus of this work is a collaboration between NETL and the Kansas Geological Survey to characterize core from the Patterson Field site. The 625 ft of whole core from the Atoka Formation to Precambrian Basement was characterized at NETL. As part of this effort, bulk scans of core were obtained. This report, and the associated scans, provide detailed datasets not typically made publicly available for carbon capture utilization and storage analysis. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/patterson-5-25-well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL are useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize core from two wells that represent coal resources across North Dakota. These include the MC23080C Well in Mercer County and the 23-B001 Well in Oliver County. The primary impetus of this work was to capture a detailed digital representation of the core from the MC23080C and 23-B001 Wells. The collaboration between the NETL and the Energy and Environment Research Center (EERC) enables other research entities to access information about this potential carbon ore, rare earth, and critical mineral resource plays in the Williston Basin. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core, with the resulting macro- and micro-descriptions relevant to many subsurface energy-related examinations traditionally performed at NETL.

01 COAL, LIGNITE, AND PEAT↗

Model studies of laser absorption computed tomography for remote air pollution measurement

Model studies of the potential of laser absorption-computed tomography are presented which demonstrate the possibility of sensitive remote atmospheric pollutant measurements, over kilometer-sized areas, with two-dimensional resolution, at modest laser source powers. An analysis of this tomographic reconstruction process as a function of measurement SNR, laser power, range, and system geometry, shows that the system is able to yield two-dimensional maps of pollutant concentrations at ranges and resolutions superior to those attainable with existing, direct-detection laser radars.

Wolfe, D. C., Jr.↗

Assessment of Localized Deformations in Sand Using X-Ray Computed Tomography

The internal fabric and localized deformation patterns of triaxial sand specimens were investigated using Computed Tomography (CT). Three displacement-controlled, conventional, drained axisymmetric (triaxial) experiments were conducted on dry Ottawa sand specimens at very low effective confining stresses (0.05, 0.52, and 1.30 kPa) in a microgravity environment aboard the Space Shuttle during the NASA STS-79 mission. CT scanning was p'erformed on these flight specimens, as well as on an uncompressed specimen and a specimen tested in a terrestrial laboratory at 1.30 kPa effective confining stress. CT demonstrated high accuracy in detecting specimen inhomogeneity and localization patterns. Formation of deformation patterns is dependent on the effective confining stress and gravity. Multiple symmetrical radial shear bands were observed in the specimens tested in a microgravity environment. In the axial direction, two major conical surfaces were developed. Nonsymmetrical spatial deformation was observed in the 1-G specimen. Analysis tools were developed to quantify the spatial density change. Void ratio variation within and outside the shear bands was calculated and discussed.

Alshibli, Khalid A↗

Demonstration of Emitted-Neutron Computed Tomography to Count Fuel Pins

In this paper, we report demonstration of emitted-neutron computed tomography using fast fission neutrons to infer the geometry of sources of special nuclear material (SNM) such as fuel pins. In a proof-of-concept measurement at the Idaho National Laboratory’s (INL’s) Zero Power Physics Reactor (ZPPR) facility, an array of unirradiated Pu MOX fuel rodlets in a soup can were imaged, and a bias defect consisting of a single rodlet containing Pu replaced by one containing depleted uranium (DU) was detected. The imaging system employed in the demonstration is based on a newly constructed array of pixelated neutron detectors that are suitable for arrangement in a close-packed imaging array and whose active volume consists of liquid scintillator EJ-309 which allows neutron-gamma discrimination via pulse shape to enable pure fast-neutron imaging. The imaging array was used along with a radial collimator aperture in order to perform high quality fast-neutron imaging where tomographic reconstruction of slices through an object resolve neutron sources similar in dimension to a fuel pellet, or about 1 cm. Measurements were performed at Oak Ridge National Laboratory (ORNL) with neutron sources in addition to those performed at the INL’s ZPPR facility with Pu MOX fuel rodlets. An analogous capability to detect single-pin defects in spent fuel assemblies would be desirable, such as for safeguards verification measurements of spent fuel assemblies just prior to transferring them from the spent fuel cooling pool to long term dry cask storage. This paper describes the design and construction of the present imager, characterization measurements with neutron sources at ORNL, measurements with SNM at INL’s ZPPR facility, and feasibility of building an analogous imager for spent fuel measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of Emitted-Neutron Computed Tomography to Count Fuel Pins

In this paper, we report demonstration of emitted-neutron computed tomography using fast fission neutrons to infer the geometry of sources of special nuclear material (SNM) such as fuel pins. In a proof-of-concept measurement at the Idaho National Laboratory s (INL s) Zero Power Physics Reactor (ZPPR) facility, an array of unirradiated Pu MOX fuel rodlets in a soup can were imaged, and a bias defect consisting of a single rodlet containing Pu replaced by one containing depleted uranium (DU) was detected. The imaging system employed in the demonstration is based on a newly constructed array of pixelated neutron detectors that are suitable for arrangement in a close-packed imaging array and whose active volume consists of liquid scintillator EJ-309 which allows neutron-gamma discrimination via pulse shape to enable pure fast-neutron imaging. The imaging array was used along with a radial collimator aperture in order to perform high quality fast-neutron imaging where tomographic reconstruction of slices through an object resolve neutron sources similar in dimension to a fuel pellet, or about 1 cm. Measurements were performed at Oak Ridge National Laboratory (ORNL) with neutron sources in addition to those performed at the INL s ZPPR facility with Pu MOX fuel rodlets. An analogous capability to detect single-pin defects in spent fuel assemblies would be desirable, such as for safeguards verification measurements of spent fuel assemblies just prior to transferring them from the spent fuel cooling pool to long term dry cask storage. This paper describes the design and construction of the present imager, characterization measurements with neutron sources at ORNL, measurements with SNM at INL s ZPPR facility, and feasibility of building an analogous imager for spent fuel measurements.

Hausladen, Paul↗

Inside marginal adaptation of crowns by X-ray micro-computed tomography

The objective of this work was to access dental arcade by using X-ray micro-computed tomography. For this purpose high resolution system was used and three groups were studied: Zirkonzahn CAD-CAM system, IPS e.max Press, and metal ceramic. The three systems assessed in this study showed results of marginal and discrepancy gaps clinically accepted. The great result of 2D and 3D evaluations showed that the used technique is a powerful method to investigate quantitative characteristics of dental arcade. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase distribution in Fischer-Tropsch mimicked slurry bubble column via computed tomography

This study aims to investigate the phases distribution and hydrodynamics in an air-Therminol LT-glass beads slurry bubble column reactor in bubbly and churn-turbulent flow regimes by implementing a gamma-ray computed tomography. It is found that gas holdup increases with increasing superficial gas velocity and operating pressure while increasing solids loading has an opposite effect on gas holdup measurements. It is noticed that the pressure effect is more significant at high solids loading and the solids loading is relatively more substantial at lower pressure. Solids loading has the most significant a stronger effect on the solids holdup profile than on the gas holdup profile. Current results were compared with the Sedimentation-Dispersion Model (SDM) predictions. Overall, the findings of this study advance the knowledge of the true behavior of phases distribution in FT mimicked slurry bubble columns which are pertinent in designing such reactors.

42 ENGINEERING↗

SU-G-IeP4-04: DD-Neutron Source Collimation for Neutron Stimulated Emission Computed Tomography: A Monte Carlo Simulation Study

Purpose: To optimize collimation and shielding for a deuterium-deuterium (DD) neutron generator for an inexpensive and compact clinical neutron imaging system. The envisioned application is cancer diagnosis through Neutron Stimulated Emission Computed Tomography (NSECT). Methods: Collimator designs were tested with an isotropic 2.5 MeV neutron source through GEANT4 simulations. The collimator is a 52×52×52 cm{sup 3} polyethylene block coupled with a 1 cm lead sheet in sequence. Composite opening was modeled into the collimator to permit passage of neutrons. The opening varied in shape (cylindrical vs. tapered), size (1–5 cm source-side and target-side openings) and aperture placements (13–39 cm from source-side). Spatial and energy distribution of neutrons and gammas were tracked from each collimator design. Parameters analyzed were primary beam width (FWHM), divergence, and efficiency (percent transmission) for different configurations of the collimator. Select resultant outputs were then used for simulated NSECT imaging of a virtual breast phantom containing a 2.5 cm diameter tumor to assess the effect of the collimator on spatial resolution, noise, and scan time. Finally, composite shielding enclosure made of polyethylene and lead was designed and evaluated to block 99.99% of neutron and gamma radiation generated in the system. Results: Analysis of primary beam indicated the beam-width is linear to the aperture size. Increasing source-side opening allowed at least 20% more neutron throughput for all designs relative to the cylindrical openings. Maximum throughput for all designs was 364% relative to cylindrical openings. Conclusion: The work indicates potential for collimating and shielding a DD neutron generator for use in a clinical NSECT system. The proposed collimator designs produced a well-defined collimated neutron beam that can be used to image samples of interest with millimeter resolution. Balance in output efficiency, noise reduction, and scan time should be considered to determine the optimal design for specific NSECT applications.

60 APPLIED LIFE SCIENCES↗