Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Multipass Simulations of Space Charge Compensation using Electron Columns at IOTA

Defocusing repulsive forces due to self space charge fields lead to degradation of high-intensity particle beams. Being of particular concern for low- and medium-energy proton beams, they result in emittance growth, beam halo formation, and beam loss. They set stringent limits on the intensity of frontier accelerators; therefore, the mitigation of space charge effects is a crucial challenge to improve proton beam intensity. The space charge effects in a positively charged proton beam can be effectively compensated using negatively charged electron columns. In this paper, we present the results of simulations using Synergia of the Electron Column lattice for IOTA. Beam loss due to space charge effects and aperture restrictions have been studied, as well as bunch formation and matching using an adiabatic ramp of the RF cavity. The results show the need for space charge compensation, and provide the basis for integration of the Synergia and Warp codes in order to form a complete simulation of space charge compensation using an Electron Column in IOTA.

43 PARTICLE ACCELERATORS↗

Investigation of uranium attenuation and release at column and pore scales in response to advective geochemical gradients

Column experiments were devised to investigate the role of changing fluid composition on mobility of uranium through a sequence of geologic media. Fluids and media were chosen to be relevant to the ground water plume emanating from the former S-3 ponds at the Oak Ridge Integrated Field Research Challenge (ORIFC) site. Synthetic ground waters were pumped upwards at 0.05 mL/minute for 21 days through layers of quartz sand alternating with layers of uncontaminated soil, quartz sand mixed with illite, quartz sand coated with iron oxides, and another soil layer. Increases in pH or concentration of phosphate, bicarbonate, or acetate were imposed on the influent solutions after each 7 pore volumes while uranium (as uranyl) remained constant at 0.1mM. A control column maintained the original synthetic groundwater composition with 0.1mM U. Pore water solutions were extracted to assess U retention and release in relation to the advective ligand or pH gradients. Following the column experiments, subsamples from each layer were characterized using microbeam X-ray absorption spectroscopy (XANES) in conjunction with X-ray fluorescence mapping and compared to sediment core samples from the ORIFC, at SSRL Beam Line 2-3.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensitivity Analysis for Saltstone Disposal Unit Column Degradation Analyses

PORFLOW related analyses supporting a Sensitivity Analysis for Saltstone Disposal Unit (SDU) column degradation were performed. Previous analyses, Flach and Taylor 2014, used a model in which the SDU columns degraded in a piecewise manner from the top and bottom simultaneously. The current analyses employs a model in which all pieces of the column degrade at the same time. Information was extracted from the analyses which may be useful in determining the distribution of Tc-99 in the various SDUs throughout time and in determining flow balances for the SDUs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two-Column Aerosol Project (TCAP): Ground-Based Radiation and Aerosol Validation Using the NOAA Mobile SURFRAD Station Field Campaign Report

The National Oceanic and Atmospheric Administration (NOAA) is preparing for the launch of the Geostationary Operational Environmental Satellite R-Series (GOES-R) satellite in 2015. This satellite will feature higher time (5-minute versus 30-minute sampling) and spatial resolution (0.5 km vs 1 km in the visible channel) than current GOES instruments provide. NOAA’s National Environmental Satellite Data and Information Service has funded the Global Monitoring Division at the Earth System Research Laboratory to provide ground-based validation data for many of the new and old products the new GOES instruments will retrieve specifically related to radiation at the surface and aerosol and its extensive and intensive properties in the column. The Two-Column Aerosol Project (TCAP) had an emphasis on aerosol; therefore, we asked to be involved in this campaign to de-bug our new instrumentation and to provide a new capability that the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Mobile Facilities (AMF) did not possess, namely surface albedo measurement out to 1625 nm. This gave us a chance to test remote operation of our new multi-filter rotating shadowband radiometer/multi-filter radiometer (MFRSR/MFR) combination. We did not deploy standard broadband shortwave and longwave radiation instrumentation because ARM does this as part of every AMF deployment. As it turned out, the ARM standard MFRSR had issues, and we were able to provide the aerosol column data for the first 2 months of the campaign covering the summer flight phase of the deployment. Using these data, we were able to work with personnel at Pacific Northwest National Laboratory (PNNL) to retrieve not only aerosol optical depth (AOD), but single scattering albedo and asymmetry parameter, as well.

54 ENVIRONMENTAL SCIENCES↗

Direct Down-scale Experiments of Concentration Column Designs for SHINE Process

Argonne is assisting SHINE Medical Technologies in their efforts to become a domestic Mo-99 producer. The SHINE accelerator-driven process uses a uranyl-sulfate target solution for the production of fission-product Mo-99. Argonne has developed a molybdenum recovery and purification process for this target solution. The process includes an initial Mo recovery column followed by a concentration column to reduce the product volume from 15-25 L to < 1 L prior to entry into the LEU Modified Cintichem (LMC) process for purification.1 This report discusses direct down-scale experiments of the plant-scale concentration column design, where the effects of loading velocity and temperature were investigated.

42 ENGINEERING↗

PNNL Report on the Development of Bench-scale CFD Simulations for Gas Absorption across a Wetted Wall Column

This report is prepared for the demonstration of hierarchical prediction of carbon capture efficiency of a solvent-based absorption column. A computational fluid dynamics (CFD) model is first developed to simulate the core phenomena of solvent-based carbon capture, i.e., the CO 2 physical absorption and chemical reaction, on a simplified geometry of wetted wall column (WWC) at bench scale. Aqueous solutions of ethanolamine (MEA) are commonly selected as a CO 2 stream scrubbing liquid. CO 2 is captured by both physical and chemical absorption using highly CO 2 soluble and reactive solvent, MEA, during the scrubbing process. In order to provide confidence bound on the computational predictions of this complex engineering system, a hierarchical calibration and validation framework is proposed. The overall goal of this effort is to provide a mechanism-based predictive framework with confidence bound for overall mass transfer coefficient of the wetted wall column (WWC) with statistical analyses of the corresponding WWC experiments with increasing physical complexity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Process with Decoupled Absorber Kinetics and Solvent Regeneration through Membrane Dewatering and In-Column Heat Transfer (Final Report)

This report summarizes the work conducted on project DE-FE0031604 where University of Kentucky Center for Applied Energy (UK CAER) has validated its intensified CO 2 capture process through substantial enhancements to the kinetics of the absorption process and energy reductions by absorber temperature profile modification, dewatering and heat integration technologies for achieving significant capital and operating cost reductions. To address DOE’s objective of improving post-combustion CO 2 capture technology and reducing associated cost, UK CAER employed an intensified process which combined three key aspects targeted at overcoming inherent limitations or barriers in the conventional CO 2 capture and desorption process. The process designed to be independent of the type of solvent used, included (1) the use of 3-D printed two-channel structured packing material to control the temperature profile and increase the CO 2 absorption rate in the absorber, (2) a zeolite membrane dewatering unit for dewatering of the carbon-rich solvent to decouple solvent concentration needs for CO 2 absorption and desorption, and (3) a rich-split feed with two-phase flow heat transfer prior to the stripper that provided a secondary point of vapor generation to provide energy savings in steam extraction and solvent regeneration. The project was executed over two budget periods. This involved testing of individual process components which included the advanced heat transfer packing and the dewatering membrane on UK CAER’s 30 liter per minute (L/min) CO 2 (3” Column) capture bench unit with simulated flue gas in the first budget period. Subsequent scaled-up testing of these components together with the split-feed configuration were also tested in UK CAER’s 0.1 MWth CO 2 capture unit with coal-derived flue gas in the second-budget period. Long term studies were done during this period to assess process and solvent performance over extended duration. Project partners Lawrence Livermore National Laboratory (LLNL) and Media & Process Technology (MPT) led the development efforts for the advanced packing material and dewatering membrane respectively. Data from the long term testing was used as input for an environmental, health and safety (EH&S) assessment for the process and scaled technology performed by ALL4 LLC. Trimeric Corporation also completed a techno-economic analysis (TEA) for the UK CAER technology which was compared to the DOE reference Case B12B. Tests on the 3” column capture unit showed that the advanced heat transfer packing could be used to lower the bulge temperature in the absorber, and this was also proven in the scaled testing in the 0.1 MWth CO 2 capture unit. The bulge temperature could be lowered by >10 °C, changing the temperature profile in the absorber, and showed potential to enhance absorption with the ability to tailor the profile to provide conditions suitable for a solvent’s properties and kinetics. Conditions for short term evaluation of a 19” zeolite dewatering membrane on the 3” column capture unit yielded desirable fluxes and sustained rejection rates of >80%. However, for the scaled testing of six membrane modules consisting of 21 parts of 31-inch-long membrane tubes in each bundle (surface area 0.3 m 2 ), over a more extended duration, similar rejection rates could not be achieved. With the split-feed of the rich stream to the stripper, improved heat recovery minimized waste heat exiting the top of the stripper. The stripper exhaust temperatures could be reduced by >10 °C; reducing the amount of water vaporization contributed to lowering the regeneration energy by ~ 15%. The energy benefit could be sustained from the long term monitoring of the solvent performance. The solvent properties were not significantly impacted over the long-term operations. The benefits of the UK CAER process demonstrated experimentally were mostly validated from the TEA comparing a commercial scale application of the technology to DOE reference Case B12B. The cost of CO 2 capture for the UK CAER technology was estimated to be ~$34.97/tonne of CO 2 captured; a reduction of 23% compared to Case B12B. The increase in cost of electricity was also shown to be 16% lower than that of Case B12B. The total parasitic demand was also shown to be 11% lower. The key drivers for the benefits are a result of the process intensification approaches employed in the UK CAER technology for enhanced solvent performance, effective heat recovery and improved energy performance. The EH&S assessment did not find any major environmental concerns or barriers to the full scale implementation of the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Integration of the fundamental knowledge on solvent-packing interactions into the multiscale framework for column scale design and optimization

The interfacial area, also known as the effective mass transfer area, is a key factor for determining the mass transfer for carbon dioxide (CO 2 ) capture via the chemical absorption process in a packed column, and thus the overall capture efficiency of the packed column. Most of the widely used empirical and semi-empirical models for interfacial area were derived indirectly through absorption mass transfer with simplifications based on fast chemical kinetics. This report presents the comprehensive unique multiscale approach to develop a surrogate model for effective mass transfer area in structured packed columns that accounts local hydrodynamics as well as variation in physical properties, and changes in solid surface characteristics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mitigation of space charge effects using electron column at IOTA ring

We investigate a novel method to mitigate space charge effects of high intensity proton beams propagating in circular accelerators by means of trapping and controlling electrons generated from beam-induced residual gas ionization. This compensation method uses Coulomb repulsion force between a proton beam and electrons to mitigate self-space charge effects of the beam if it passes through a plasma column. The transverse electron-proton (e-p) instability in the plasma column is well controlled by the longitudinal magnetic field of a solenoid magnet and the bias voltages on electrodes. In this report, we will show simulation results how to control distributions of electrons and ions as well as that of the proton beam inside the column.

43 PARTICLE ACCELERATORS↗

Study of Bubble Size, Void Fraction, and Mass Transport in a Bubble Column under High Amplitude Vibration

Vertical vibration is known to cause bubble breakup, clustering and retardation in gas-liquid systems. In a bubble column, vibration increases the mass transfer ratio by increasing the residence time and phase interfacial area through introducing kinetic buoyancy force (Bjerknes effect) and bubble breakup. Previous studies have explored the effect of vibration frequency (f), but minimal effort has focused on the effect of amplitude (A) on mass transfer intensification. Thus, the current work experimentally examines bubble size, void fraction, and mass transfer in a bubble column under relatively high amplitude vibration (1.5 mm < A <9.5 mm) over a frequency range of 7.5–22.5 Hz. Results of the present work were compared with past studies. The maximum stable bubble size under vibration was scaled using Hinze theory for breakage. Results of this work indicate that vibration frequency exhibits local maxima in both mass transfer and void fraction. Moreover, an optimum amplitude that is independent of vibration frequency was found for mass transfer enhancements. Finally, this work suggests physics-based models to predict void fraction and mass transfer in a vibrating bubble column.

Mohagheghian, Shahrouz↗

Smooth H i Low Column Density Outskirts in Nearby Galaxies

The low column density gas at the outskirts of galaxies as traced by the 21 cm hydrogen line emission (H i) represents the interface between galaxies and the intergalactic medium, i.e., where galaxies are believed to get their supply of gas to fuel future episodes of star formation. Photoionization models predict a break in the radial profiles of H i at a column density of ∼5 × 10{sup 19} cm{sup −2} due to the lack of self-shielding against extragalactic ionizing photons. To investigate the prevalence of such breaks in galactic disks and to characterize what determines the potential edge of the H i disks, we study the azimuthally averaged H i column density profiles of 17 nearby galaxies from the H i Nearby Galaxy Survey and supplemented in two cases with published Hydrogen Accretion in LOcal GAlaxieS data. To detect potential faint H i emission that would otherwise be undetected using conventional moment map analysis, we line up individual profiles to the same reference velocity and average them azimuthally to derive stacked radial profiles. To do so, we use model velocity fields created from a simple extrapolation of the rotation curves to align the profiles in velocity at radii beyond the extent probed with the sensitivity of traditional integrated H i maps. With this method, we improve our sensitivity to outer-disk H i emission by up to an order of magnitude. Except for a few disturbed galaxies, none show evidence of a sudden change in the slope of the H i radial profiles: the alleged signature of ionization by the extragalactic background.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of column-averaged methane in models and TCCON with a focus on the stratosphere

The distribution of methane (CH 4 ) in the stratosphere can be a major driver of spatial variability in the dry-air column-averaged CH 4 mixing ratio (XCH 4 ), which is being measured increasingly for the assessment of CH 4 surface emissions. Chemistry-transport models (CTMs) therefore need to simulate the tropospheric and stratospheric fractional columns of XCH 4 accurately for estimating surface emissions from XCH 4 . Simulations from three CTMs are tested against XCH 4 observations from the Total Carbon Column Network (TCCON). We analyze how the model–TCCON agreement in XCH 4 depends on the model representation of stratospheric CH 4 distributions. Model equivalents of TCCON XCH 4 are computed with stratospheric CH 4 fields from both the model simulations and from satellite-based CH 4 distributions from MIPAS (Michelson Interferometer for Passive Atmospheric Sounding) and MIPAS CH 4 fields adjusted to ACE-FTS (Atmospheric Chemistry Experiment Fourier Transform Spectrometer) observations. Using MIPAS-based stratospheric CH 4 fields in place of model simulations improves the model–TCCON XCH 4 agreement for all models. For the Atmospheric Chemistry Transport Model (ACTM) the average XCH 4 bias is significantly reduced from 38.1 to 13.7 ppb, whereas small improvements are found for the models TM5 (Transport Model, version 5; from 8.7 to 4.3 ppb) and LMDz (Laboratoire de Météorologie Dynamique model with zooming capability; from 6.8 to 4.3 ppb). Replacing model simulations with MIPAS stratospheric CH 4 fields adjusted to ACE-FTS reduces the average XCH 4 bias for ACTM (3.3 ppb), but increases the average XCH 4 bias for TM5 (10.8 ppb) and LMDz (20.0 ppb). These findings imply that model errors in simulating stratospheric CH 4 contribute to model biases. Current satellite instruments cannot definitively measure stratospheric CH 4 to sufficient accuracy to eliminate these biases. Applying transport diagnostics to the models indicates that model-to-model differences in the simulation of stratospheric transport, notably the age of stratospheric air, can largely explain the inter-model spread in stratospheric CH 4 and, hence, its contribution to XCH 4 . Furthermore, it would be worthwhile to analyze how individual model components (e.g., physical parameterization, meteorological data sets, model horizontal/vertical resolution) impact the simulation of stratospheric CH 4 and XCH 4 .

54 ENVIRONMENTAL SCIENCES↗

Water Column Respiration in the Yakima River Basin is Explained by Temperature, Nutrients and Suspended Solids

Understanding aquatic ecosystem metabolism involves the study of two key processes: carbon fixation via primary production and organic C mineralization as total ecosystem respiration (ERtot). In streams and rivers, ERtot includes respiration in the water column (ERwc) and in the sediments (ERsed). While literature surveys suggest that ERsed is often a dominant contributor to ERtot, recent studies indicate that the relative influence of sediment-associated processes versus water column processes can fluctuate along the river continuum. Still, a comprehensive understanding of the factors contributing to these shifts within basins and across stream orders is needed. Here we contribute to this need by measuring ERwc and collecting water samples across 47 sites in the Yakima River basin, Washington, USA. We found that ERwc rates varied throughout the basin during baseflow conditions, ranging from –7.38 to 0.36 g O2 m?3 d?1, and encompassed the range of ERwc literature values. Additionally, by comparing to ERtot estimates for rivers across the contiguous United States, we suggest that the contribution of ERwc rates to reach-scale ERtot rates across the Yakima River was likely highly variable, but we did not test this directly. We observed that temperature, nutrient concentrations (dissolved organic carbon, total dissolved nitrogen), and total suspended solids explained 41% of ERwc variability across the basin. Our findings highlight the potential relevance of water column processes in aquatic ecosystem metabolism, with the Yakima River basin serving as an environmentally diverse river network representative of the larger Columbia River basin that spans much of the Pacific Northwest region of the United States. Our results are generally congruent with previous work, suggesting that the observed variability and suite of associated environmental factors influencing ERwc are potentially transferable across basins.

Laan, Maggi M.↗

Transient flow and heating characteristics in a pinched plasma column.

The generation of axial flow and heating of an argon plasma in a pinched plasma column of a pulsed, linear z-pinch device was examined experimentally and analytically. Transient (about 5 microsec) axial pressure profiles identify three characteristic periods in the column history. These include (1) strong axial pressure asymmetry indicative of plasma streaming, (2) isotropic, rapidly rising plasma pressure indicative of plasma heating, and (3) column breakup. An efficient conversion of radial collapse to axial streaming velocity is identified. Mechanisms for such an effect and subsequent heating are evaluated; significance to transients in pulsed plasma accelerators is identified.

York, T. M.↗

Column densities resulting from shuttle sublimator/evaporator operation

The proposed disposal of H2O from the shuttle fuel cell operation by ejecting it in vapor form through a supersonic nozzle at the rate of 100 lb/day has been investigated from the point of view of the possible interference to astronomical experiments. If the nozzle is located at the tail and directed along the shuttle longitudinal axis, the resulting column density will be less than 10 to th 12th power molecules/sq cm at viewing angles larger than 48 deg above the longitudinal axis. The molecules in the trail will diffuse rapidly. The column density contribution from molecules expelled on the previous orbit is 1.3 x 10 to the 8th power molecules/sq cm. This contribution diminishes by the inverse square root of the number of orbits since the molecules were expelled. The molecular backscatter from atmospheric molecules is also calculated. If the plume is directed into the flight path, the column density along a perpendicular is found to be 1.5 x 10 to the 11th power molecules/sq cm. The return flux is estimated to be of the order of 10 to the 12th power molecules/sq cm/sec at the stagnation point. With reasonable care in design of experiments to protect them from the backscatter flux of water molecules, the expulsion of 100 lb/day does not appear to create an insurmountable difficulty for the shuttle experiments.

Naumann, R. J.↗

Molecular column densities in selected model atmospheres

From an examination of predicted column densities, the following conclusions were drawn: (1) The SiO ought to be visible in carbon stars which were generated from triple alpha burning, but absent from carbon stars generated from the CNO bi-cycle. (2) Variation in the observed relative strengths of TiO and ZrO is indicative of real differences in the ratio Ti/Zr. (3) The TiO/ZrO ratio shows a small variation as C/O and effective temperature is changed. (4) Column density of silicon dicarbide (SiC2) is sensitive to abundance, temperature, and gravity; hence all relationships between the strength of SiC2 and other stellar parameters will show appreciable scatter. There is however, a substantial luminosity effect present in the SiC2 column densities. (5) Unexpectedly, SiC2 is anti-correlated with C2. (6) The presence of SiC2 in a carbon star eliminates the possibility of these stars having temperatures greater than or equal to 3000 K, or being produced through the CNO bi-cycle.

Johnson, H. R.↗

Preparative liquid column electrophoresis of T and B lymphocytes at gravity = 1

Vertical liquid columns containing low-molecular-weight dextran density gradients can be used for preparative lymphocyte electrophoresis on earth, in simulation of zero gravity conditions. Another method that has been tested at 1 g, is the electrophoresis of lymphocytes in an upward direction in vertical columns. By both methods up to 100 million lymphocytes can be separated at one time in a 30-cm glass column of 8-mm inside diameter, at 12 V/cm, in two hours. Due to convection and sedimentation problems, the separation at 1 g is less than ideal, but it is expected that at zero gravity electrophoresis will probe to be a uniquely powerful cell separation tool.

Van Oss, C. J.↗

Experimental study of the stability and flow characteristics of floating liquid columns confined between rotating disks

A low Bond number simulation technique was used to establish the stability limits of cylindrical and conical floating liquid columns under conditions of isorotation, equal counter rotation, rotation of one end only, and parallel axis offset. The conditions for resonance in cylindrical liquid columns perturbed by axial, sinusoidal vibration of one end face are also reported. All tests were carried out under isothermal conditions with water and silicone fluids of various viscosities. A technique for the quantitative measurement of stream velocity within a floating, isothermal, liquid column confined between rotatable disks was developed. In the measurement, small, light scattering particles were used as streamline markers in common arrangement, but the capability of the measurement was extended by use of stereopair photography system to provide quantitative data. Results of velocity measurements made under a few selected conditions, which established the precision and accuracy of the technique, are given. The general qualitative features of the isothermal flow patterns under various conditions of end face rotation resulting from both still photography and motion pictures are presented.

Fowle, A. A.↗