Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coding standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Review and Gap Analysis of Heliostat Components and Controls

This investigation provides a comprehensive literature review pertaining to heliostat components and controls as part of the U.S. Department of Energy (DOE), Heliostat Consortium (Heliocon) program. Here, this work presents a detailed assessment of subcomponents, controls and wireless communications elements that comprise various designs of helisotats within concentrating solar power (CSP) installations. Additionally, this work also provides the results of an industry survey, intended to compliment the literature discussion, to provide a gap analysis of the primary technology and cost areas that need to be addressed to help improved to spur concentrating solar power (CSP) bankability. Although the results of the study determined several key areas for development, three strategic areas identified were: (1) the use of advanced composite materials to replace a need for expensive steel within the structure and mirror substrate, (2) employment of closed-loop controls for automated calibration, reduction of commissioning time and O&M hours, reduction of drive requirements, as well as overall cost reduction, and (3) the need for more Heliostat-centric codes and standards to facilitate engineering confidence in the development of new features, cost reductions, or other design iterations to be seamlessly introduced without optical performance problems.

14 SOLAR ENERGY↗

QCOR

The QCOR compiler provides a mechanism for the expression and compilation of quantum code alongside standard, modern C++. It does so through integration with Clang and its robust abstract syntax tree analysis tools, as well as integration with the XACC infrastructure.

Maccaskey, AlexanderJ↗

GridSTIX

SF-25-112 Grid-STIX is a comprehensive extension of the STIX (Structured Threat Information Expression) 2.1 ontology specifically designed for electrical grid cybersecurity applications. This ontology provides a standardized, machine-readable framework for modeling grid assets, operational technology devices, threats, vulnerabilities, supply chain risks, and security relationships in electrical power systems. ## Key Features - **Comprehensive Grid Coverage**: Physical assets, OT devices, grid components, sensors, and energy storage systems - **Zero Trust Architecture**: Policy decision points, enforcement points, trust brokers, and continuous monitoring - **AMI Infrastructure**: Advanced metering networks, head-end systems, mesh gateways, and MDM systems - **Advanced Security Modeling**: Attack patterns, vulnerabilities, mitigations, and supply chain risks - **Critical Grid Relationships**: Power flow, protection, control, and synchronization relationships - **Supply Chain Security**: Supplier modeling, country of origin tracking, and risk assessment - **Protocol Support**: DNP3, Modbus, IEC 61850, IEC 60870-5-104, OPC-UA, and IEEE standards - **Python Code Generation**: Automated STIX-compliant Python class generation from ontologies - **Interactive Visualization**: Enhanced HTML network graphs with grid-specific categorization - **STIX 2.1 Compliance**: Full compatibility with STIX threat intelligence ecosystem

Blakely, Benjamin [Argonne National Laboratory (AN↗

Digital-Twin-Enabling Technologies for Online Condition Monitoring of Nuclear Power Plant Components

Online condition monitoring is an area of active research that may enable optimized scheduling, maintenance, and safety of nuclear power plant components, reducing unnecessary derates while simultaneously improving operational capacity. Digital twins (DTs) are one avenue to conduct online condition monitoring and are currently being explored by national laboratories and universities alike. DTs for online condition monitoring are, in essence, state concurrent models that emulate a physical process which predicts a parameter and compares it against a measured value. A DT’s goal is to provide additional insights by combining and interpreting various sources of information for preventative maintenance scheduling optimization or early fault detection. DTs for condition monitoring are projected to be valuable for meeting requirements under 10 CFR 50.55a, “Codes and Standards,” and 10 CFR 50.65, “Requirements for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants”. However, DT technologies are still under significant development, and the process for developing a DT for condition monitoring has not been formalized. Therefore, in this work, we present an initial framework for developing a DT, discuss and review the various challenges and considerations for DT deployment, and identify the opportunities that a DT can improve. The presented framework is intended to help developers formulate a strategy when approaching DT development for condition monitoring. In conclusion, a DT use case for a reactor coolant pump is presented to demonstrate the proposed framework.

advanced sensor instrumentation↗

The Energy Transition: Advanced Nuclear Needed but Address Climate Vulnerabilities Now

The term “Energy Transition” is an attempt to capture an elaborate set of activities related to the modernization and decarbonization of energy grids. Performed concurrently and often in an ad hoc manner across local, state, regional and national boundaries, it is bringing chaos to what should arguably be one of the most conservatively managed of all critical infrastructure sectors. What’s more, with climate change producing an increasing tempo of extreme events, confidence in the intended resilient and redundant structure of the electric grids is likely to ebb. Even without these climate induced stressors, the nation’s electric grid was built for an earlier century. In addition to a drive towards greater efficiency via digitization and a continuing price decline in distributed energy resources (DERs), one could argue that climate change concerns are the primary driver of the energy transition. Non-CO2 emitting generation sources like wind and solar have become an important part of the overall generation fleet, albeit ones that cannot be counted upon to provide dispatchable power. Current projections indicate deployment of even larger percentages of DERs in coming years. Until far better storage capabilities arrive, the variability of wind and solar, inconsistent performance of traditional thermal generation plants, and energy delivery failures associated with natural gas pipelines will reinforce mounting reliability concerns. This pertains to both electric transmission and distribution. The recent shuttering of nuclear power plants in Germany, Japan, the US and elsewhere are also putting more downward pressure on dispatchable generation. Russia’s attack on Ukraine has roiled energy markets worldwide and forced some countries to return to coal as a primary fuel. In view circumstances such as these, it is essential that significant changes be made to policies and planning criteria, and to the standards and code on which they are based. Given the accelerating pace of extreme weather events, this needs to occur as soon as possible.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building a Solar Powered Home in a Historic Neighborhood. A Case Study with CVF Homes, the City of San Antonio Office of Historic Preservation and the Lavaca Neighborhood Association

A Texas collaboration is working to streamline and enable an increase in photovoltaic capacity. The City of San Antonio has made tremendous progress in recent years in the area of solar energy installations on residences. These projects have been great successes, though not without the usual challenges associated with solar energy installations. The City has also seen an increased interest in solar energy systems in official “historic” neighborhoods. These installations have a potential for added challenges, as neighborhoods designated “historic” have additional restrictions, aside from standard building codes, about what changes and upgrades can be done to the exterior. This is in an effort to maintain the historic qualities of the homes and preserve the historical nature of the neighborhoods in which they are present. The purpose of this case study was to examine the construction of a new, single family home, with an included solar energy system, in an official historic neighborhood in San Antonio. Build San Antonio Green hoped to uncover what specific additional challenges the builder faced when working in a historic neighborhood and how those challenges were overcome, to serve as a model for other builders wishing to install solar energy systems in historic neighborhoods. This is of particular importance, as the City of San Antonio has more than 20 officially designated historic neighborhoods, and without proper knowledge of how to comply with the additional regulations, contractors, builders, and solar installers could potentially miss out on tremendous opportunities.

14 SOLAR ENERGY↗

Hydrogen quantitative risk assessment workshop proceedings.

The Quantitative Risk Assessment (QRA) Toolkit Introduction Workshop was held at Energetics on June 11-12. The workshop was co-hosted by Sandia National Laboratories (Sandia) and HySafe, the International Association for Hydrogen Safety. The objective of the workshop was twofold: (1) Present a hydrogen-specific methodology and toolkit (currently under development) for conducting QRA to support the development of codes and standards and safety assessments of hydrogen-fueled vehicles and fueling stations, and (2) Obtain feedback on the needs of early-stage users (hydrogen as well as potential leveraging for Compressed Natural Gas [CNG], and Liquefied Natural Gas [LNG]) and set priorities for %E2%80%9CVersion 1%E2%80%9D of the toolkit in the context of the commercial evolution of hydrogen fuel cell electric vehicles (FCEV). The workshop consisted of an introduction and three technical sessions: Risk Informed Development and Approach; CNG/LNG Applications; and Introduction of a Hydrogen Specific QRA Toolkit.

97 MATHEMATICS AND COMPUTING↗

Measure Guideline: Selecting Ventilation Systems for Existing Homes

This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electronic Safety Resource Tools -- Supporting Hydrogen and Fuel Cell Commercialization

The Pacific Northwest National Laboratory (PNNL) Hydrogen Safety Program conducted a planning session in Los Angeles, CA on April 1, 2014 to consider what electronic safety tools would benefit the next phase of hydrogen and fuel cell commercialization. A diverse, 20-person team led by an experienced facilitator considered the question as it applied to the eight most relevant user groups. The results and subsequent evaluation activities revealed several possible resource tools that could greatly benefit users. The tool identified as having the greatest potential for impact is a hydrogen safety portal, which can be the central location for integrating and disseminating safety information (including most of the tools identified in this report). Such a tool can provide credible and reliable information from a trustworthy source. Other impactful tools identified include a codes and standards wizard to guide users through a series of questions relating to application and specific features of the requirements; a scenario-based virtual reality training for first responders; peer networking tools to bring users from focused groups together to discuss and collaborate on hydrogen safety issues; and a focused tool for training inspectors. Table ES.1 provides results of the planning session, including proposed new tools and changes to existing tools.

08 HYDROGEN↗

Energy Implications of In-Line Filtration in California

Occupant concern about indoor air quality (IAQ) issues has led to the increased use of more effective air filters in residential heating and cooling systems. This study performed measurements in ten California houses to determine the effects of changing filter performance and related characteristics on the energy use of the heating and cooling systems. Multiple filters were evaluated covering a wide range of filter effectiveness from simple low filtration fiberglass filters up to high efficiency filters that might be used by occupants concerned about IAQ. Sophisticated analysis and simulation tools used the field-testing results to determine filter impacts for a wide range of parameters and California climates. The results indicate that for MERV 10/11/13 filters the effects on energy use are moderate (<5%) over a wide range of performance conditions and climates. Using higher MERV 16 filters can lead to significantly increased energy use (>5%). The high airflow resistance of MERV 16 filters led to excess noise in some test houses from air bypassing the filter and the blower motor. Filter loading rates varied more from house to house than by MERV rating and overall were quite low in many of the homes. Filter related energy use does not need to be addressed for filters of MERV 10/11/13 and MERV 16 filters should only be used with low leakage tested ducts unless the filter is mounted at the blower compartment. MERV 16 filters should only be used if the filter area is sufficient to prevent noise issues and if the duct system has low air flow resistance and low leakage. Filters should be labeled for their air flow resistance, or static pressure at a particular flow rate, that would allow codes and standards to reference a particular performance specification and allow contractors and homeowners to make informed purchases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comparison of Simulation Capabilities for Ducts

Typically, the cheapest way to install a central air conditioning system in residential buildings is to place the ductwork in the attic. Energy losses due to duct-attic interactions can be great, but current whole-house models are unable to capture the dynamic multi-mode physics of the interactions. The building industry is notoriously fragmented and unable to devote adequate research resources to solve this problem. Builders are going to continue to put ducts in the attic because floor space is too expensive to closet them within living space, and there are both construction and aesthetic issues with other approaches such as dropped ceilings. Thus, there is a substantial need to publicly document duct losses and the cost of energy used by ducts in attics so that practitioners, builders, homeowners and state and federal code officials can make informed decisions leading to changes in new construction and additional retrofit actions. Thus, the goal of this study is to conduct a comparison of AtticSim and EnergyPlus simulation algorithms to identify specific features for potential inclusion in EnergyPlus that would allow higher-fidelity modeling of HVAC operation and duct transport of conditioned air. It is anticipated that the resulting analysis from these simulation tools will inform energy decisions relating to the role of ducts in future building energy codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of the Cryogenic Hydrogen Release Laboratory

A cooperative research and development agreement was made between Linde, LLC and Sandia to develop a plan for modifying the Turbulent Combustion Laboratory (TCL) with the necessary infrastructure to produce a cold (near liquid temperature) hydrogen jet. A three-stage heat exchanger will be used to cool gaseous hydrogen using liquid nitrogen, gaseous helium, and liquid helium. A cryogenic line from the heat exchanger into the lab will allow high-fidelity diagnostics already in place in the lab to be applied to cold hydrogen jets. Data from these experiments will be used to develop and validate models that inform codes and standards which specify protection criteria for unintended releases from liquid hydrogen storage, transport, and delivery infrastructure.

08 HYDROGEN↗

Duct Leakage Repeatability Testing

The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Selecting Ventilation Systems for Existing Homes

This report, developed by Building America research team CARB, addresses adding or improving mechanical ventilation systems to existing homes. The goal of this report is to assist decision makers and contractors in making informed decisions when selecting ventilation systems for homes. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including examination of relevant codes and standards. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industry Perspectives on Advanced Inverters for U.S. Solar Photovoltaic Systems. Grid Benefits, Deployment Challenges, and Emerging Solutions

To clarify current utility strategies and other considerations related to advanced inverter deployment, we interviewed 20 representatives from 11 leading organizations closely involved with advanced inverter pilot testing, protocols, and implementation. Included were representatives from seven utilities, a regional transmission operator, an inverter manufacturer, a leading solar developer, and a consortium for grid codes and standards. Interview data represent geographically the advanced inverter activities identified in SEPA's prior survey results--most interviewed utilities serve California, Arizona, and Hawaii, though we also interviewed others from the Northeast, Mid-Atlantic, and Southeast.

14 SOLAR ENERGY↗

2014 DOE Hydrogen and Fuel Cells Program Annual Merit Review and Peer Evaluation Report

This report summarizes comments from the Peer Review Panel at the 2014 DOE Hydrogen and Fuel Cells Program Annual Merit Review, held on June 16-20, 2014, in Washington, DC. It covers the program areas of hydrogen production and delivery; hydrogen storage; fuel cells; manufacturing R&D; technology validation; safety, codes, and standards; market transformation; and systems analysis.

amr↗

2014 Annual Progress Report: DOE Hydrogen and Fuel Cells Program

The 2014 Annual Progress Report summarizes fiscal year 2014 activities and accomplishments by projects funded by the DOE Hydrogen Program. It covers the program areas of hydrogen production and delivery; hydrogen storage; fuel cells; manufacturing; technology validation; safety, codes and standards; market transformation; and systems analysis.

apr↗