Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Equidistant optimization of elliptical superconducting rf standing wave cavities

A record accelerating rate was achieved earlier in standing wave (SW) SRF cavities when their shape was optimized for a lower peak surface magnetic field sacrificing the peak surface electric field. In view of new materials with higher limiting magnetic fields, expected for SRF cavities, in the first line of the Nb 3 Sn, the approach to optimization of cavity shape should be revised. A method of equidistant optimization, offered earlier for traveling wave (TW) cavities is applied to SW cavities. It is shown here that without limitation by magnetic field, the maximal accelerating rate is defined not only by limitations of the electric field but to a significant degree by the cavity shape. For example, for a cavity with the aperture radius of $R$ $a$ = 35 mm, the minimal ratio of the peak surface electric field to the accelerating rate is about $E$ pk / $E$ acc = 1.54. So, with the maximal surface field experimentally achieved $E$ pk ~ 125 MV / m, the maximal achievable accelerating rate is about 80 MeV / m even if there are no restrictions by the magnetic field. Optimized cavity shapes with and without limitations by a magnetic field are presented. Another opportunity—optimization for a low magnetic field, is opening for the same material, Nb 3 Sn, with the purpose of having a high-quality factor and increased accelerating rate that can be used for industrial linacs with cryocooler-based cooling scheme.

43 PARTICLE ACCELERATORS↗

Variational Self-Consistent Theory for Beam-Loaded Cavities

A new variational theory is presented for beam loading in microwave cavities. The beam{field interaction is formulated as a dynamical interaction whose stationarity according to Hamilton’s principle will naturally lead to steady-state solutions that indicate how a cavity’s resonant frequency, Q and optimal coupling coefficient will detune as a result of the beam loading. A driven cavity Lagrangian is derived from first principles, including the effects of cavity wall losses, input power and beam interaction. The general formulation is applied to a typical klystron input cavity to predict the appropriate detuning parameters required to maximize the gain (or modulation depth) in the average Lorentz factor boost, (Δ γ). Numerical examples are presented, showing agreement with the general detuning trends previously observed in the literature. The developed formulation carries several advantages for beam-loaded cavity structures. It provides a self-consistent model for the dynamical (nonlinear) beam{field interaction, a procedure for maximizing gain under beam-loading conditions, and a useful set of parameters to guide cavity-shape optimization during the design of beam-loaded systems. Enhanced clarity of the physical picture underlying the problem seems to be gained using this approach, allowing straightforward inclusion or exclusion of different field configurations in the calculation and expressing the final results in terms of measurable quantities. Two field configurations are discussed for the klystron input cavity, using finite magnetic confinement or no confinement at all. Formulating the problem in a language that is directly accessible to the powerful techniques found in Hamiltonian dynamics and canonical transformations may potentially carry an additional advantage in terms of analytical computational gains, under suitable conditions

43 PARTICLE ACCELERATORS↗

Seamless High-Q Microwave Cavities for Multimode Circuit Quantum Electrodynamics

Multimode cavity quantum electrodynamics ---where a two-level system interacts simultaneously with many cavity modes---provides a versatile framework for quantum information processing and quantum optics. Due to the combination of long coherence times and large interaction strengths, one of the leading experimental platforms for cavity QED involves coupling a superconducting circuit to a 3D microwave cavity. In this work, we realize a 3D multimode circuit QED system with single photon lifetimes of $2$ ms and cooperativities of $0.5-1.5\times10^9$ across 9 modes of a novel seamless cavity. We demonstrate a variety of protocols for universal single-mode quantum control applicable across all cavity modes, using only a single drive line. We achieve this by developing a straightforward flute method for creating monolithic superconducting microwave cavities that reduces loss while simultaneously allowing control of the mode spectrum and mode-qubit interaction. We highlight the flexibility and ease of implementation of this technique by using it to fabricate a variety of 3D cavity geometries, providing a template for engineering multimode quantum systems with exceptionally low dissipation. This work is an important step towards realizing hardware efficient random access quantum memories and processors, and for exploring quantum many-body physics with photons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-93: Creation of Standardized APBI SAVI Cavities Using CT Registration

Purpose: Develop a consistent and rapid method of generating the initial cavity structure for Accelerated Partial Breast Irradiation (APBI) using the SAVI applicator. Methods: Four SAVI (Cianna Medical) applicators (6-1 Mini, 6-1, 8-1, and 10-1) were scanned on a CT simulator. The applicators were scanned in air with the CT slices (0.625mm axial thickness) perpendicular to the long axis of the applicator. Following scanning the CT images were transferred to Eclipse (Varian Medical Systems) and contours of the cavity were drawn. The cavity proximal and distal locations were defined according to MD specification. The scans and contours were then re-imported into the CT virtual simulation workstation.At the time of patient planning the appropriate applicator scan is anonymized and imported into Eclipse. In Brachytherapy Planning two Marker points are placed, one at the distal band location (cavity start) and the second at a defined distance along the applicator (cavity end). The actual patient scan is then registered to the applicator scan. A three point match is used to quickly get the two scans in approximate alignment. Manually matching is then used to fine tune the alignment of the cavity contour and Marker points. Results: The standard applicator scans have shown to agree well with the applicators in the patient scans. The time taken to register the scans has shown to be less than generating the cavities using the standard methods of contouring on the axial slices or using the dose shaper with sources in the central channel. Conclusion: The registration of a standard applicator scan and contour has improved the consistency in the generation of the initial cavity (SAVI) structure. Planning structures used for dose calculation are created with that structure as a starting point so accuracy and consistency are important for dose evaluation and plan comparison.

60 APPLIED LIFE SCIENCES↗

SU-F-T-43: Prediction of Dose Increments by Brain Metastases Resection Cavity Shrinkage Model with I-125 and Cs-131 LDR Seed Implantations

Purpose: This work aims to determine dose variability via a brain metastases resection cavity shrinkage model (RC-SM) with I-125 or Cs-131 LDR seed implantations. Methods: The RC-SM was developed to represent sequential volume changes of 95 consecutive brain metastases patients. All patients underwent serial surveillance MR and change in cavity volume was recorded for each patient. For the initial resection cavity, a prolate-ellipsoid cavity model was suggested and applied volume shrinkage rates to correspond to 1.7, 3.6, 5.9, 11.7, and 20.5 months after craniotomy. Extra-ring structure (6mm) was added on a surface of the resection volume and the same shrinkage rates were applied. Total 31 LDR seeds were evenly distributed on the surface of the resection cavity. The Amersham 6711 I-125 seed model (Oncura, Arlington Heights, IL) and the Model Cs-1 Rev2 Cs-131 seed model (IsoRay, Richland, WA) were used for TG-43U1 dose calculation and in-house-programed 3D-volumetric dose calculation system was used for resection cavity rigid model (RC-RM) and the RC-SM dose calculation. Results: The initial resection cavity volume shrunk to 25±6%, 35±6.8%, 42±7.7%, 47±9.5%, and 60±11.6%, with respect to sequential MR images post craniotomy, and the shrinkage rate (SR) was calculated as SR=56.41Xexp(−0.2024Xt)+33.99 and R-square value was 0.98. The normal brain dose as assessed via the dose to the ring structure with the RC-SM showed 29.34% and 27.95% higher than the RC-RM, I-125 and Cs-131, respectively. The dose differences between I-125 and Cs-131 seeds within the same models, I-125 cases were 9.17% and 10.35% higher than Cs-131 cases, the RC-RM and the RC-SM, respectively. Conclusion: A realistic RC-SM should be considered during LDR brain seed implementation and post-implement planning to prevent potential overdose. The RC-SM calculation shows that Cs-131 is more advantageous in sparing normal brain as the resection cavity volume changes with the LDR seeds implementation.

60 APPLIED LIFE SCIENCES↗

Nb3Sn Thin Films for the Production of Higher Gradient SRF Cavities at Reduced Cost

High gradient superconducting cavities (SRF) will be needed for future accelerators. The higher gradient can achieve the high energy with fewer cavities. However the accelerating field of niobium cavities is limited by the peak magnetic field on the cavity surface. Cavities coated with Nb3Sn have a significantly larger Hc2 allowing the cavity to achieve a larger gradient. Measurements of Nb3Sn coated cavities have achieved about half the theoretical predicted gradient. It is possible to improve Nb3Sn plated cavity performance.

43 PARTICLE ACCELERATORS↗

Modified Slow Tuner Design for Cavity 1 Inside LCLS II Cryomodules

Initial LCLS-II cryomodule testing at Fermilab showed microphonics on the furthest upstream cavity (number 1) at least factor 2 larger than on the rest of the cavities. Testing indicated that this was a difference in the mechanical support of cavity 1, not a local acoustic source. Further investigation pointed to the upstream beam-pipe of the cavity 1. The upstream cavity flange has a solid spool piece connection to the beamline gate valve unlike the other cavities, which all connect through bellows. The gate valve's weight is supported by sliding system (free in z-axis) connected to large diameter Helium gas return pipe. The tuner design was modified to transform interface between cavity#1 and gate valve. Arms of the tuner for cavity 1 were extended and became the support structure for gate valve, eliminating the connection to the helium return pipe. Modification of the tuner design and results in microphonics mitigations will be presented.

43 PARTICLE ACCELERATORS↗

Status of PIP-II 650 MHz Prototype Dressed Cavity Qualification

Low-beta and high-beta sections of PIP-II linac will use nine low-beta cryomodules with four cavities each and four high-beta cryomodules with six cavities each. These cavities will be produced and qualified in collaboration between Fermilab and the international partner labs. Prior to their installation into prototype cryomodules, several dressed cavities, which include jacketed cavities, high power couplers, and tuners, will be qualified in STC horizontal test bed at Fermilab. After qualification of bare β = 0.9 cavities at Fermilab, several pre-production β = 0.92 and β = 0.61 cavities have been and are being fabricated and qualified. Procurements have also been started for high power couplers and tuners. In this contribution we present the current status of prototype dressed cavity qualification for PIP-II.

43 PARTICLE ACCELERATORS↗

Cavity Qualification and Production Update for SNS-PPU Cryomodules at Jefferson Lab

The Proton Power Upgrade (PPU) project at Oak Ridge National Lab’s Spallation Neutron Source (SNS) currently being constructed will double the proton beam power capability from 1.4 to 2.8 MW by adding seven cryomodules, each containing four six-cell high-beta (β = 0.81) superconducting radio frequency cavities. Research Instruments, located in Germany, built and processed the cavities at the vendor site, including electropolishing as the final active chemistry step. Twenty-eight cavities for seven cryomodules and an additional four cavities for a spare cryomodules were delivered to Jefferson Lab and first qualification tests were completed on all cavities as received from the vendor. The performance largely exceeded the requirements on quality factor and accelerating gradient. Here we present the status of initial cavity qualification tests, rework on unqualified cavities and final cavity qualification with helium vessel prior to installation in cryomodules. In addition, an update on cryomodule production is presented.

Dhakal, P.↗

Test Result of 650 MHz, Beta 0.61 Single Cell Niobium Cavity

VECC has been involved in the design, analysis and development of 650 MHz, beta 0.61 (LB650), elliptical Superconducting RF linac cavity, as part of research and development activities on SRF cavities and associated technologies under Indian Institutions Fermilab Collaboration (IIFC). A single-cell niobium cavity has been indigenously designed and developed at VECC, with the help of Electron Beam Welding (EBW) facility at IUAC, New Delhi. Various measurements, processing and testing at 2K in Vertical Test Stand (VTS) of the single-cell cavity was carried out at ANL and Fermilab, USA, with active participation of VECC engineers. It achieved a maximum accelerating gradient(Eacc) of 34.5 MV/m with Quality Factor of 2·10⁹ and 30 MV/m with Quality Factor of 1.5·10¹⁰. This is probably the highest accelerating gradient achieved so far in the world for LB650 cavities. This paper describes the design, fabrication and measurement of the single cell niobium cavity. Cavity processing and test results of Vertical Test of the single-cell niobium cavity are also presented.

43 PARTICLE ACCELERATORS↗

RECENT RESULTS FROM Nb3Sn SINGLE CELL CAVITIES COATED AT JLAB

Because of superior superconducting properties (Tc ~ 18.3K, Hs h ~ 425 mT and ? ~ 3.1 meV) compared to niobium, Nb3Sn promise better RF performance (Q0 and Eacc) and/or higher operating temperature (2 K Vs 4.2 K) for SRF cavities. Nb3Sn-coated SRF cavities are produced routinely by depositing a few micron-thick Nb3Sn films inside of Nb cavities via tin vapor diffu-sion technique. Early results from Nb3Sn cavities coat-ed with this technique exhibited precipitous low field Q-slope, also known as Wuppertal slope. Several Nb3Sn single cell cavities coated at JLab appeared to exhibit similar Q-slope. RF testing of cavities and ma-terials study of witness samples were continuously used to modify the coating protocol. At best condition, we were able to produce Nb3Sn cavity with Q0 in ex-cess of ? 5×1010 at 2 K and ? 2×1010 at 4 K up the ac-celerating gradient of ~15 MV/m, without any signifi-cant Q-slope. In this presentation, we will discuss re-cent results from several Nb3Sn coated single-cell cavities linked with material studies of witness sam-ples, coating process modifications and the possible causative factors to Wuppertal slope.

Pudasaini, U.↗

New Design of SSR2 Spoke Cavity for PIP II SRF Linac

Superconducting SSR2 spoke cavities provide acceleration of the H- in PIP II SRF linac from 35 to 185 MeV. The RF and mechanical design of the SSR2 cavities has been completed and satisfies the technical requirements. However, our resent results of the high RF power tests of fully dressed SSR1 cavities show considerably strong multipacting (MP), which took significant time to process. On the other hand, the new results of the tests of balloon cavity showed significant mitigation of MP. In this paper we present the results of the improved design of the SSR2 cavity, based on the balloon cavity concept. The electromagnetic design is presented, including RF parameter optimization, MP simulations, field asymmetry analysis, High Order Mode (HOM) calculations. Mechanical analysis of the dressed cavity is presented also, which includes Lorentz Force Detuning (LFD) optimization, and reduction of the cavity resonance frequency sensitivity versus He pressure fluctuations. The design completely satisfies the PIP II technical requirements.

43 PARTICLE ACCELERATORS↗

Comparing the Effectiveness of Low Temperature Bake in EP and BCP Cavities

Electropolishing (EP) and buffered chemical polishing (BCP) are conventional surface preparation techniques for superconducting radiofrequency (SRF) cavities. Both EP and BCP treated SRF cavities display high field Q-slope (HFQS) which degrades performance at high gradients. While high gradient performance in EP cavities can be improved by introducing oxygen via a low temperature bake (LTB) of 120^{°}C by 48 hours, LTB does not consistently remove HFQS in BCP cavities. There is no consensus as to why LTB is not effective on BCP prepared cavities. We examine quench in EP, BCP, EP+LTB, and BCP+LTB treated 1.3 GHz single-cell Nb cavities by studying the heating behavior with field using a temperature mapping system. Cavity performance is correlated to characterizations of surface impurity profile obtained via time of flight secondary ion mass spectrometry studies. We observe a difference in near surface hydrogen concentration following BCP compared to EP that may suggest that the causes of quench in EP and BCP cavities are different.

43 PARTICLE ACCELERATORS↗

Higher order model power calculation of the 56 MHz SRF cavity

A 56 MHz superconducting RF cavity (SRF) is going to be installed in Relativistic Heavy Ion Collider (RHIC) ring for the luminosity upgrade of the RHIC operation. Currently, it is being designed and prototype-tested as an Accelerator Improvement Project (AIP). The 56 MHz SRF cavity will be turned on at store of the RHIC operation. When the beam frequencies overlap or come close to the cavity HOM frequencies, the HOMs are excited in the cavity, which may lead to beam instability. Since the shunt impedance of the superconducting cavity tends to be higher than that of the copper cavity, the voltage developed in the cavity due to the HOM excitation can in principle be large. Therefore, suppressing the HOMs is an important task for the 56 MHz SRF cavity. To pursue the task, understanding the frequencies, Q factors and shunt impedances for the HOMs is prerequisite. Based on the given HOM characteristic, the HOM power can be calculated. The simulation results from the available programs as well as the prototype measurement results are used for the analysis.

43 PARTICLE ACCELERATORS↗

Geometric Optimization of the 56MHz SRF Cavity and its Frequency Table

It is essential to know the frequency of a Superconducting Radio Frequency (SRF) cavity at its “just being fabricated” stage because frequency is the key parameter in constructing the cavity. In this paper, we report our work on assessing it. We can estimate the frequency change from stage to stage theoretically and/or by simulation. At the operating stage, the frequency can be calculated accurately, and, from this value, we obtain the frequencies at other stages. They are listed in a table that serves to check the processes from stage to stage. Equally important is optimizing the geometric shape of the SRF cavity so that the peak electric-field and peak magnetic-field are as low as possible. It is particularly desirable in the 56MHz SRF cavity of RHIC to maximize the frequency sensitivity of the slow tuner. After undertaking such optimization, our resultant peak electric-field is only 35.3MV/m, and the peak magnetic-field is 840G at 2MV of voltage across the cavity gap. To quench superconductivity in an SRF cavity, it is reported that the limit of the peak magnetic-field is 1800G [1], and that of the peak electric-field is more than 100MV/m for a SRF cavity [2]. Naturally, for the complex geometry of this cavity (including numerous electron beam welds) and 4.2K operations we do not expect record field performance, but a useful 2 MV gap voltage is reasonable to expect. Our simulations employed the codes Superfish and Microwave Studio.

43 PARTICLE ACCELERATORS↗

Conduction Cooling of a Niobium SRF Cavity Using a Cryocooler

Superconducting Radio Frequency (SRF) cavities are the primary choice for accelerating charged particles in high-energy research accelerators. Institutions like Fermilab use SRF cavities because they enable significantly higher gradients and quality factors than normal-conducting RF cavities and DC voltage cavities. To cool the SRF cavities to low temperatures (typically around 2 K), liquid helium refrigerators are used. Producing and maintaining the necessary liquid helium requires large, elaborate cryogenic plants involving dewars, compressors, expansion engines, and recyclers. The cost, complexity, and space required for such plants is part of the reason that industry has not yet adopted SRF-based accelerators. At the Illinois Accelerator Research Center (IARC) at Fermilab, our team seeks to make SRF technology accessible not only to large research accelerators, but to industry as well. If we eliminate the complexity associated with liquid helium plants, SRF-based industrial accelerators may finally become a reality. One way to do this is to eliminate the use of liquid helium baths altogether and develop a brand-new cooling technique for SRF cavities: conduction cooling using a cryocooler. Recent advances in SRF technology have made it possible to operate SRF cavities at 4 K, a temperature easily achievable using commercial cryocoolers. Our IARC team is taking advantage of this technology to cool SRF cavities.

43 PARTICLE ACCELERATORS↗

Crab cavity requirements for the Jefferson Lab Electron-Ion Collider

An Electron-Ion Collider (EIC) has been proposed to be the next large facility to explore the dynamics of quarks and gluons inside nuclei. A conceptual design for a Jefferson Lab Electron-Ion Collider (JLEIC) is being developed. It is based on the CEBAF 12 GeV machine as a full energy electron beam injector. Two crucial requirements of JLEIC are high luminosity in the 10 34 cm -2 s -1 range, and full acceptance detection of particles. The full acceptance requirement relies on having the beams collide at a relatively large crossing angle of 50 mrad. Such a large crossing angle, however, can reduce the luminosity by as much as an order of magnitude. One way to compensate for geometric luminosity loss due to the beam crossing angle is using crab cavities. Crab cavities are superconducting radio-frequency structures optimized to produce a transverse force that 'tilts' the beam bunches in such a way that a head-on collision is restored at the collision point, thus restoring the luminosity. A second set of crab cavities is placed downstream of the collision point and is used to cancel the initial bunch tilt, ideally suppressing any crab-induced effects anywhere else in the rings. In this dissertation, we study the dynamics of JLEIC beams with a bunch crabbing scheme using particle tracking simulations. We first evaluate the beam stability when crab cavities are included in the collider rings and then use this stable model to study effects of crab cavity multipoles and RF noise. We also study the role of crab cavity higher-order modes (HOM) in driving coupled-bunch instability and identify dangerous HOM which need to be damped. A specific crab cavity for JLEIC has not yet been selected. It is the purpose of this dissertation to provide general requirements and tolerances to make future crab cavity designs compatible with JLEIC.

Sosa Guitron, Salvador↗

AASC Coated Cavities

The price of niobium is a significant part of the cost of superconducting RF cavity production. One route to significant cost reduction is to use cavities that have a thin layer of niobium deposited on a less expensive substrate. However, to date, all attempts to use thin films of niobium in superconducting RF cavities have resulted in cavity performance that does not meet the requirements for modern linear accelerators. Fermilab will provide two (2) cavities to AASC. AASC will coat the two (2) cavities with niobium using its high-purity deposition method. AASC will return the coated cavities to Fermilab for Quality Assurance (QA) testing. If the coatings pass preliminary QA tests performed at Fermilab, they will be subjected to RF testing at Fermilab and their performance will be evaluated relative to solid niobium cavities.

43 PARTICLE ACCELERATORS↗